← All vessels
DIXIELAND HEAT
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named DIXIELAND HEAT
DIXIELAND HEAT is a 1974 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 1980, most recently in August 2025, along with 18 deficiencies and 1 casualty investigation in 2022.
Records from 1980 to 2025. Most recent: inspection, 13 August 2025.
- Built
- 1974
- Last inspected
- 13 August 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2022
Identity
561221
WDK2143
48201
Flag
UNITED STATES
368032780
Maury page id
psix-48201
Inspections, by type
…with no type recorded5
Years with a record
23 calendar years (1980–2025)
The 34 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)29.5 ft × 12.5 ft × 4.1 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 30 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK2143MMSI 368032780 · active · compulsorily equipped · granted 14 April 2018, expires 14 April 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 34
13 August 2025
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8209019
26 July 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7947097
30 January 2023
Deficiency Check · COI Inspection · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7628830
10 March 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7394886
28 February 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7845802
8 February 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7137348
6 January 2020
Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6872603
9 December 2019
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6862161
29 July 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6767218
2 May 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6675535
1 February 2019
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6618589
9 March 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6365983
18 August 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6437271
9 March 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6100941
18 February 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5813483
7 January 2016
Administrative Inspection · Examination of Repairs · In-Service Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5793264
22 May 2008
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3213365
4 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087447
23 February 1995
Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 853801
24 August 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 961638
12 August 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1157290
9 February 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1455049
30 January 1992
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011700
31 January 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901500
15 November 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1216075
26 January 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1206377
19 April 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1341139
23 February 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332444
11 December 1986
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009650
17 December 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985433
19 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285917
15 December 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283322
16 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965512
16 December 1980
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966516
Deficiency record · 18
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 September 2025
Resolved
A hatch exposed to the weather must be watertight. Engine hatch gasket material was missing.
Replace gasket material around hatch to the of the attending MI.
46 CFR 179.360(a)(New T)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 January 2023
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. It was reported to DMI that the vessel experienced a fire on the tire fendering system in the vicinity of the engine exhaust outlet. No further details as to why the fires origination were provided. The vessel is restricted from movement at its current location, Crescent Ship Service, Ama until the DMI can asses the vessel.
46CFR185.100
60c.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 January 2023
Resolved
An inspection for renewal of a certificate of inspection shall include an inspection of the structure, machinery and equipment. The inspection shall be such as to insure that the vessel, as regards the structure, piping, main and auxiliary machinery, electrical installations. lifesaving appliances, fire extinguishing equipment, pollution prevention equipment and other equipment, is in satisfactory condition and fit for the service for which it is intended and that it complies with the regulations in this subchapter to the extent that such regulations are applicable to the vessel being inspected. Upon post fire damage survey MI found the
vessel out of compliance with subchapter T regulations. Vessel is prohibited from movement until a complete inspection for certification is conducted. Should vessel need to be moved from its current location, it only may do so after an approved transit plan is submitted and approved by the attending MI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 March 2022
Resolved
Electrical equipment must be maintained to protect passengers, crew, and other persons and vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine Inspector found excessive dust and oil on the generators' windings. Clear and identify cause to the satisfaction of the attending Marine Inspector.
46 CFR 183.200(b)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 March 2022
Resolved
Each hatch cover must have securing devices. The Marine Inspector found the fwd and aft hatches do not have operational securing mechanism. Repair or replace to the satisfaction of the attending Marine Inspector.
46 CFR 171.124(b)(1) (old S)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 March 2022
Resolved
Generators and motors designed for 40 degrees Celsius may be unused in the 50 degree ambient locations provided the machines are derated to 80% of full load rating, and the rating or setting of the over-current devices is reduced accordingly. An additional nameplate specifying the derated capacity shall be provided for each such motor and generator. The Marine Inspector observed a generator rated for 40 degrees Celcuis, but does not have a nameplate specifying the derated capacity.
46 CFR 183.10-5 (old T)
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 10 March 2022
Resolved
The master or person in charge of a ship to which this section applies, shall ensure that one or more placards meeting the requirements of this section are displayed in a prominent location and in sufficient numbers. Marine Inspector observed the old version of the garbage placard displayed. Replace with new color coded version of the garbage placard.
33 CFR 151.59(a)
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 10 March 2022
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast procedures, specific to the individual vessel. The Marine Inspector observed that there were no emergency broadcast instruction placards posted. Refer to 46 CFR 184.510 for an example.
46 CFR 184.25-1 and 46 CFR 184.506
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 March 2022
Resolved
The shutoff valve at each tank shall be operable from outside of the tank compartment, preferably from an accessible position on the weather deck. Marine Inspector observed that the weather deck mounted remote fuel shutoff was disconnected from the valve adjacent to the fuel tank. The remote fuel shutoff was reconnected and tested in the presence of Marine Inspector.
46 CFR 182.20-40(b)(3)(old T)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2022
Resolved
All wiring shall be run as high as practicable above bilges. Marine Inspector observed wiring for bilge alarm laying in bilge. Extra wiring was secured as high as practicable above the bilge.
46 CFR 183.05-50 (a)(a) (old T)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 March 2022
Resolved
All machinery essential to the routine operation of the vessel be checked. Marine Inspector observed loose packing in the rudder posts during the steering system test. Rudder posts were repacked and tested in the presence of the Marine Inspector.
46 CFR 176.25-10(a)(4)
Documentation
Issued 9 February 1993
Resolved
PERFORM STABILITY TEST IN ACCORDANCE WITH 46CFR171.020.
Construction/Loadline
Issued 9 February 1993
Resolved
EFFECT PERMANENT REPAIRS TO APPROX 12" FRACTURE AT TRANSOM TOP/GUNWALE AND FRACTURE IN STEERING COMPARTMENT STBD STERN CORNER AT APPROX 2 FT DRAFT._x001C_ DEWATER BILGES IN STEERING COMPARTMENT.
Electrical
Issued 9 February 1993
Resolved
RENEW LEAD LINING IN BATTERY BOX.
Engineering
Issued 9 February 1993
Resolved
PROVIDE GUARDS ON ALL V-BELT PULLYS BOTH MAIN ENGINES.
Engineering
Issued 9 February 1993
Resolved
EFFECT REPAIRS AND PROVE OPERATION OF STBD ENGINE KILL SWITCH.
Lifesaving
Issued 23 February 1988
Resolved
PROPERLY AFFIX RETRREFLECTIVE MATERIAL TO THE VESSEL'S LIFE PRESERVERS, ON THE REVERSIBLE SIDES, IN ACCORDANCE WITH 46 CFR 180.25-25.
Lifesaving
Issued 23 February 1988
Resolved
PROPERLY POST THE EMERGENCY INSTRUCTIONS IN ACCORDANCE WITH 46 CFR 185.25.
Casualty record · 1
28 February 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7845802
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.