DIXIELAND HEAT

Built
1974
Last inspected
13 August 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 August 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK2143
Flag
UNITED STATES
Maury page id
psix-48201

Documentation record

Registered dimensions (L × B × D)29.5 ft × 12.5 ft × 4.1 ft
Registered tonnagegross 14 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 30 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

13 August 2025 Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8209019
26 July 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7947097
30 January 2023 Deficiency Check · COI Inspection · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7628830
10 March 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7394886
28 February 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7845802
8 February 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7137348
6 January 2020 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6872603
9 December 2019 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6862161
29 July 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6767218
2 May 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6675535
1 February 2019 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6618589
9 March 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6365983
18 August 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6437271
9 March 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6100941
18 February 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5813483
7 January 2016 Administrative Inspection · Examination of Repairs · In-Service Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5793264

Deficiency record · 11

03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 September 2025 Resolved
A hatch exposed to the weather must be watertight. Engine hatch gasket material was missing. Replace gasket material around hatch to the of the attending MI. 46 CFR 179.360(a)(New T)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 September 2025
Resolution: Vessel rep provided video proof of newly installed gasket material on engine room hatch.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 January 2023 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. It was reported to DMI that the vessel experienced a fire on the tire fendering system in the vicinity of the engine exhaust outlet. No further details as to why the fires origination were provided. The vessel is restricted from movement at its current location, Crescent Ship Service, Ama until the DMI can asses the vessel. 46CFR185.100 60c.
Action required: 60 - Rectify deficiencies prior to movement
Due 30 January 2023
Resolved 9 October 2023
Resolution: Vessel conducted necessary repairs at DD. All Sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 January 2023 Resolved
An inspection for renewal of a certificate of inspection shall include an inspection of the structure, machinery and equipment. The inspection shall be such as to insure that the vessel, as regards the structure, piping, main and auxiliary machinery, electrical installations. lifesaving appliances, fire extinguishing equipment, pollution prevention equipment and other equipment, is in satisfactory condition and fit for the service for which it is intended and that it complies with the regulations in this subchapter to the extent that such regulations are applicable to the vessel being inspected. Upon post fire damage survey MI found the vessel out of compliance with subchapter T regulations. Vessel is prohibited from movement until a complete inspection for certification is conducted. Should vessel need to be moved from its current location, it only may do so after an approved transit plan is submitted and approved by the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 January 2023
Resolved 9 October 2023
Resolution: Vessel assessed and transitted to DD.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 March 2022 Resolved
Electrical equipment must be maintained to protect passengers, crew, and other persons and vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine Inspector found excessive dust and oil on the generators' windings. Clear and identify cause to the satisfaction of the attending Marine Inspector. 46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 11 March 2022
Resolved 11 March 2022
Resolution: Vessel provided pictures of clean winding and replacement of rear seal. all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 March 2022 Resolved
Each hatch cover must have securing devices. The Marine Inspector found the fwd and aft hatches do not have operational securing mechanism. Repair or replace to the satisfaction of the attending Marine Inspector. 46 CFR 171.124(b)(1) (old S)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2022
Resolved 11 March 2022
Resolution: Old hatch covers were replaced with new functional covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 March 2022 Resolved
Generators and motors designed for 40 degrees Celsius may be unused in the 50 degree ambient locations provided the machines are derated to 80% of full load rating, and the rating or setting of the over-current devices is reduced accordingly. An additional nameplate specifying the derated capacity shall be provided for each such motor and generator. The Marine Inspector observed a generator rated for 40 degrees Celcuis, but does not have a nameplate specifying the derated capacity. 46 CFR 183.10-5 (old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2022
Resolved 20 March 2022
Resolution: Provided load test data for generator as was done for other vessels in the fleet.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 10 March 2022 Resolved
The master or person in charge of a ship to which this section applies, shall ensure that one or more placards meeting the requirements of this section are displayed in a prominent location and in sufficient numbers. Marine Inspector observed the old version of the garbage placard displayed. Replace with new color coded version of the garbage placard. 33 CFR 151.59(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2022
Resolved 11 March 2022
Resolution: Provided proof of order of new placard. Mounted a laminated copy of the new placard until it is delivered.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 10 March 2022 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast procedures, specific to the individual vessel. The Marine Inspector observed that there were no emergency broadcast instruction placards posted. Refer to 46 CFR 184.510 for an example. 46 CFR 184.25-1 and 46 CFR 184.506
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2022
Resolved 11 March 2022
Resolution: Vessel posted proper emergency broadcast instructions.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 March 2022 Resolved
The shutoff valve at each tank shall be operable from outside of the tank compartment, preferably from an accessible position on the weather deck. Marine Inspector observed that the weather deck mounted remote fuel shutoff was disconnected from the valve adjacent to the fuel tank. The remote fuel shutoff was reconnected and tested in the presence of Marine Inspector. 46 CFR 182.20-40(b)(3)(old T)
Action required: 10 - Deficiency Rectified
Due 10 March 2022
Resolved 10 March 2022
Resolution: The remote fuel shutoff was reconnected and tested in the presence of Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2022 Resolved
All wiring shall be run as high as practicable above bilges. Marine Inspector observed wiring for bilge alarm laying in bilge. Extra wiring was secured as high as practicable above the bilge. 46 CFR 183.05-50 (a)(a) (old T)
Action required: 10 - Deficiency Rectified
Due 10 March 2022
Resolved 10 March 2022
Resolution: Extra wiring was secured as high as practicable above the bilge in the presence of the Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 March 2022 Resolved
All machinery essential to the routine operation of the vessel be checked. Marine Inspector observed loose packing in the rudder posts during the steering system test. Rudder posts were repacked and tested in the presence of the Marine Inspector. 46 CFR 176.25-10(a)(4)
Action required: 10 - Deficiency Rectified
Due 10 March 2022
Resolved 10 March 2022
Resolution: Rudder posts were repacked and tested in the presence of the Marine Inspector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.