MAURY USCG vessel records Sign in
← All vessels

SEA RUNNER

SEA RUNNER is a 1974 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 1982, most recently in May 2012, along with 22 deficiencies.

Records from 1982 to 2012. Most recent: inspection, 25 May 2012.

Built
1974
Last inspected
25 May 2012
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC8871
Flag
UNITED STATES
366927590, 367094330 (licence lapsed)
Maury page id
psix-48222

Inspections, by type

…with no type recorded5
Years with a record 29 calendar years (1982–2012)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.1 ft × 15.0 ft × 6.1 ft
Registered tonnagegross 29 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC8871MMSI 367094330 · expired · compulsorily equipped · granted 23 February 2016, cancelled 25 April 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDB6621MMSI 366927590 · expired · compulsorily equipped · granted 26 February 2004, cancelled 3 May 2014 · licensed under a name not among this hull’s recorded names (not shown)
WCZ4527MMSI not assigned · expired · voluntarily equipped · granted 12 August 1999, cancelled 17 October 2009 · licensed under a name not among this hull’s recorded names (not shown)
WCX9301MMSI not assigned · expired · compulsorily equipped · granted 23 January 1998, cancelled 29 March 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 38

25 May 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4333505
6 December 2011 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4202707
23 April 2009 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3458563
25 July 2008 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3278745
24 April 2008 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3191495
26 June 2007 MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2974777
13 April 2006 Internal Structural Exam · Hull Examination · MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2624021
26 April 2004 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2052701
7 April 2004 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2039422
4 December 2003 Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1958659
5 November 2003 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1810074
7 October 2002 Re-Inspection · Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1686631
25 March 2002 Hull Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1597367
6 June 2001 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1471620
24 May 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1384774
12 April 2000 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 821057
10 August 1999 Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1423286
14 December 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808023
6 October 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465419
16 October 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398786
18 October 1996 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1164850
18 October 1996 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461742
30 October 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396402
22 October 1994 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363137
19 October 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469409
19 October 1992 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444686
28 October 1991 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 942396
22 October 1990 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1220983
24 October 1989 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 897927
17 October 1988 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888340
20 October 1987 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1323411
15 October 1986 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017089
12 November 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996607
26 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292206
4 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283535
15 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972190
17 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277187
7 July 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967331

Deficiency record · 22

Documentation › Certificates/Documents › Stability Letter
Issued 6 December 2011 Resolved
Owner/Operator failed to submit stability certification compliance by 01DEC11. Issued CG-835 reducing maximum persons allowed to 42 based on the assumed average weight per person of 185 pounds and in accordance with 46 CFR 178.320 amended by FR vol. 75, No. 239, USCG-2007-0030. Reduction will remain in effect until Owner/Operator submits stability certification compliance to Coast Guard.
Action required: 705 - Other - as specified
Resolved 26 March 2012
Resolution: Received compliance letter.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 25 July 2008 Resolved
Provide NOAA Registration Form for EPIRB to Marine Inspector.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 25 July 2008
Resolution: Owner faxed copy of EPIRB registration to MI.
Lifesaving › Lifefloat › Serviceable
Issued 26 June 2007 Resolved
Make repairs to all lifefloats with manufacturers approved repair kit.
Action required: 705 - Other - as specified
Due 26 July 2007
Resolved 27 July 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 26 June 2007 Resolved
Replace retroreflective tape in way of all lifefloats.
Action required: 705 - Other - as specified
Due 26 July 2007
Resolved 27 July 2007
Engineering › Bilge Water Management System › Piping
Issued 26 June 2007 Resolved
Replace leaking elbow in way of engine room bilge piping prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2007
Engineering › Bilge Water Management System › Hose
Issued 26 June 2007 Resolved
Replace flexible hose section in way of bilge piping.
Action required: 705 - Other - as specified
Due 26 July 2007
Resolved 27 July 2007
Construction/Loadline › Hull › Sheerstrake
Issued 26 June 2007 Resolved
Repair fractured weld in stern plating at sheer strake prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Resolved 27 July 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 April 2006 Resolved
Provide machinery guard around two pulleys IWO stbd engine fwd.
Due 20 May 2006
Resolved 24 April 2006
Resolution: Transferred to def check case.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 20 April 2006 Resolved
Provide rescue platform for vessel.
Due 20 May 2006
Resolved 24 April 2006
Resolution: Transferred to def check case.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 26 April 2004 Resolved
Install 30x30 mesh screen for fuel vent screen. LEGACY COMPONENT DESC: Vent Pipe
Due 15 May 2004
Resolved 26 May 2004
Resolution: Sent photo of installed vent.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 26 April 2004 Resolved
Properly label life float paddles with vessel name.
Due 15 May 2004
Resolved 26 May 2004
Resolution: Sent photo of properly labelled paddels .
Documentation › Logs/Records
Issued 26 April 2004 Resolved
Provide drug and alcohol program information for crew. Including contract, testing, supervisor training, and properly post hotline number. LEGACY COMPONENT DESC: Drug Test Records
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2004
Resolved 26 May 2004
Lifesaving › Rigid Liferafts
Issued 5 November 2003 Resolved
ATTACH WEAK LINK FOR THE LIFE FLOATS TO THE VESSEL. LEGACY COMPONENT DESC: Weak Link
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2003
Resolved 4 December 2003
Resolution: WEAK LINKS INSTALLED CORRECTLY.
Lifesaving › Rigid Liferafts
Issued 5 November 2003 Resolved
REPLACE ALL PENDANT LINES AS REQUIRED ON ALL LIFE FLOATS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2003
Resolved 4 December 2003
Resolution: ALL PENDANTS REPLACED AS NEEDED.
Lifesaving › Rigid Liferafts
Issued 5 November 2003 Resolved
INSTALL SPACERS BETWEEN ALL LIFE FLOATS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2003
Resolved 4 December 2003
Resolution: SPACERS INSTALLED.
Communications › Alarms/Indicators
Issued 5 November 2003 Resolved
REPAIR BILGE ALARM SWITCH FOR THE RUDDER ROOM. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2003
Resolved 4 December 2003
Resolution: BILGE ALARM REPAIRED.
Engineering › Sea-water System (primary cooling)
Issued 5 November 2003 Resolved
DOUBLE CLAMP THE BLACK HOSES ON THE SUCTION SIDE OF THE STARBOARD SIDE MAIN ENGINE RAW WATER PUMP. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 December 2003
Resolved 4 December 2003
Resolution: HOSE CLAMPS INSTALLED.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 5 November 2003 Resolved
FABRICATE AND INSTALL GUARD FOR THE STARBOARD SIDE MAIN ENGINE ALTERNATOR AND JABSCO PUMP.
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 4 December 2003
Resolution: GUARD INSTALLED.
Electrical › Electrical Distribution System (service)
Issued 5 November 2003 Resolved
REMOVE HOSEHOLD PLUG AND MAKE PERMANENT ELECTRICAL CONNECTION INSIDE THE BOX FOR THE 12 VOLT POWER SUPPLY TO THE HEAD. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 5 December 2003
Resolved 4 December 2003
Resolution: WIRING CORRECTED.
Communications › Radio Communications
Issued 7 October 2002 Resolved
REPLACE EPIRB ANTENNA DUE TO OUTER HOUSING CRACKING. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 November 2002
Resolved 17 October 2002
Resolution: ANTENNA REPLACED.
Lifesaving › Hand Flares
Issued 7 October 2002 Resolved
REPLACE ALL OUTDATED ORANGE SMOKE AND RED FLARES. LEGACY COMPONENT DESC: Condition
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 November 2002
Resolved 17 October 2002
Resolution: FLARES REPLACED.
Construction/Loadline
Issued 6 October 1998 Resolved
Install check valves on all bilge suction lines to the satisfaction of the attending Marine Inspector by 06NOV98.
Condition: Unknown
Due 6 October 1998
Resolved 6 October 1998

Ownership record