Records from 2001 to 2025. Most recent: inspection, 11 December 2025.
Inspection history · 17
11 December 2025
COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8300922
12 March 2025
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8092516
11 April 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8064050
15 February 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7637074
11 April 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7428911
13 April 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7175148
21 January 2021
Initial Certification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7128578
13 January 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7123883
11 August 2017
Type not recorded
No type recorded · USCGC SAILFISH (WPB 87356) · USCG Northeast District (CGD-NE) · Activity 6243175
10 August 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6030174
18 February 2016
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5818667
7 January 2011
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3921200
27 May 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3749367
11 March 2010
Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3693946
11 April 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2906145
25 July 2006
Uninspected Other
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2724257
6 July 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 183378
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 April 2022
Resolved
Vessels display lights and day shapes IAW 33CFR83&84. Vessel is missing day shapes. Install dayshapes IAW COLREGS.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2022
Resolution: MI attended vessel and verified presence of appropriate day shapes on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2022
Resolved
Stowage positions for life jackets must be marked with quantity, identity, and size IAW 46CFR141.340. Markings were missing. Mark appropriately.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2022
Resolution: Vsl had satisfactory markings installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 April 2022
Resolved
Alarms from the engine room must be visible and audible at the operating station. The alarms were not visible. Install light for each alarm or make it a summary alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2022
Resolution: Conducted satisfactory testing for visual & audible alarms of bilge and hydraulic low-level at operating station.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 11 April 2022
Resolved
All exposed hazard such as gears and rotating machinery, must be protected by a cover, guard, or rail. All 3 shafts were unprotected and exposed. Install guards.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 April 2022
Resolution: Verified satisfactory installation of machinery guards/covers over all three shafts.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 January 2021
Resolved
Vessel does not have a rigid buoyant apparatus required for intended route.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2021
Resolved 26 January 2021
Resolution: New Life float installed and labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 January 2021
Resolved
Forward and aft void gaskets must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2021
Resolved 26 January 2021
Resolution: New rubber watertight gasket installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 January 2021
Resolved
Vessel does not have log book, drill documentation, or documentation of conducted tests as per Subchapter M
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 18 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 January 2021
Resolved
Vessel does not have evidence of company drug testing program on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 18 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 January 2021
Resolved
Alcohol test strips are expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 26 January 2021
Resolution: New test strips installed onboard.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 January 2021
Resolved
Safety orientation for crew must be conducted on board and documented.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 18 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 January 2021
Resolved
One life ring must be without a line attached.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 26 January 2021
Resolution: The line was remoaved and both ring buoys are in compliance.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 January 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 26 January 2021
Resolution: New FCC license issued.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 21 January 2021
Resolved
Ship station bill is not applicable to the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 26 January 2021
Resolution: The station Bill matches the vessel and crew specifics.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 21 January 2021
Resolved
Piping and machinery components that exceed 220 C, including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Vessels exhaust manifold was not properly insulated. Vessel must install protective insulation around exposed areas of the exhaust manifold.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 18 May 2022
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 21 January 2021
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or essential system develops problems that require attention. Vessel did not have a low level alarm for hydraulic steering fluid installed. Vessel must install alarm to provide notification when there is a low level of hydraulic fluid.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 26 January 2021
Resolution: New low level alarm installed and tested.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 January 2021
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions. Vessels emergency lighting in engine did not work.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 26 January 2021
Resolution: A socket style battle lantern was installed and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 21 January 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Guards around moving parts in the engine room need to be installed.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 26 January 2021
Resolution: Guards installed properly.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 January 2021
Resolved
Portable watertight containers for pyrotechnic distress signals must be of a bright color. Vessel’s pyrotechnic container was painted dark green.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 26 January 2021
Resolution: Distress signals are now in a water tight high visible container with proper markings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 January 2021
Resolved
Vessel must provide closure devices for hull penetrations, which open to the exterior of the vessel and may allow water to enter the vessel. Keel cooler does not have a closure valve.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 26 January 2021
Resolution: The valve is not required due to the keel cooler is of the integral type. This def was issued in error.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 21 January 2021
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency, the operator must secure each type I or type II device in a manner which prevents discharge of treated or untreated sewage. Vessel did not have a means of securing marine sanitation device.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 18 May 2022
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 21 January 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Zip ties holding electrical cables in the engine room need replaced. Light covers in the engine room are missing. General alarm light in the engine room is not properly secured. Battery box in the engine room is not properly secured. Outlet covers in the engine room are missing. Electrical panel in the engine room has foam filling in blanks. Vessel utilized power strips on the bridge. Wiring below operating station has ends open to environment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2021
Resolved 18 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 January 2021
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. Pressure vessel does not have MAWP indicated.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2021
Resolved 18 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 January 2021
Resolved
Vessel given 90 days to complete initial COI inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 April 2021
Resolved 6 April 2021
Resolution: COI issued
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 25 July 2006
Resolved
Panel broken
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2006
Fire Fighting › Fire Pumps › Pressure
Issued 25 July 2006
Resolved
Vessel did not have required fire pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2006
Fire Fighting › Semiportable CO2 Fire Extinguishers › Condition
Issued 25 July 2006
Resolved
Vessel did not have required B-V ext
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2006
Personnel › Training › Fire Fighting Basic
Issued 25 July 2006
Resolved
Vessel failed to complete required fire drills
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2006