SUBSEA RESPONDER

SUBSEA RESPONDER is a 1998 offshore supply vessel. The Coast Guard has recorded 56 inspections since 1998, most recently in April 2026, along with 123 deficiencies — 3 with no resolution recorded —, 2 operational controls and 2 casualty investigations between 2012 and 2014.

Records from 1998 to 2026. Most recent: inspection, 10 April 2026.

Built
1998
Last inspected
10 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9201645 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A5816
482259
Flag
MARSHALL ISLANDS
369363000
Maury page id
psix-482259

Inspections, by type

…with no type recorded11
…past their stated due date3
Years with a record 22 calendar years (1998–2026)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it2217 - Convention (Subpart B), Gross Ton
665 - Convention (Subpart B), Net Ton
1982 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KRSIMMSI 369363000 · active · compulsorily equipped · granted 14 September 2018, expires 14 September 2028
KSUJMMSI 303318000 · cancelled · compulsorily equipped · granted 17 July 2018, cancelled 13 September 2018
WDG3574MMSI 367566000 · expired · compulsorily equipped · granted 26 April 2012, cancelled 2 July 2022
WDF5273MMSI 338621000 · expired · compulsorily equipped · granted 20 July 2010, cancelled 19 September 2020 · licensed under a name not among this hull’s recorded names (not shown)
WDE3039MMSI 366633000 · expired · compulsorily equipped · granted 24 January 2008, cancelled 31 March 2018 · licensed under a name not among this hull’s recorded names (not shown)
WCZ7062MMSI 366633000 · expired · compulsorily equipped · granted 13 March 2000, cancelled 15 May 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 56

10 April 2026 PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8344617
5 November 2025 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8264889
14 May 2025 PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8133556
20 November 2023 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7827299
7 November 2023 PSC B · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7821339
6 November 2023 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7822266
16 August 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7769036
3 February 2023 PSC A
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7633905
17 September 2022 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7562057
23 August 2022 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7549132
26 July 2022 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7517706
23 June 2022 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7485271
4 March 2022 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7405893
8 February 2022 ACP COI Oversight · COI Inspection · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7392573
21 October 2020 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7081897
17 September 2020 ACP Handover Survey · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7034228
12 February 2020 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6909414
6 January 2020 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6883230
4 November 2018 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6576922
2 October 2018 Deficiency Check · MTSA/ISPS Verification · Commercial Dive Inspection · COI Inspection · Construction Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6553274
15 November 2017 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6304038
12 January 2016 Deficiency Check · ISM Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5796259
22 October 2015 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5748971
18 October 2015 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5745975
14 August 2015 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5219239
29 July 2015 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5199791
13 July 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5183213
16 June 2014 Annual Inspection · MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex VI Survey · Deficiency Check · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4890099
10 February 2012 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4241985
20 December 2011 Plan Review (Other than "T") · Drydock Exam · COI Inspection · Administrative Inspection · MTSA/ISPS Verification · Construction Oversight · Inclining Experiment · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4211518
23 February 2011 MTSA/ISPS Verification · Periodic Inspection · DAPI Audit · Inclining Experiment · MARPOL Annex I Examination · Examination of Repairs
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3950423
10 November 2008 MTSA/ISPS Verification · Ballast Water Examination · Administrative Inspection · Hull Examination · COI Inspection · Commercial Dive Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3360439
11 June 2008 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3233963
19 May 2008 Plan Review (Other than "T") · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3210903
14 January 2008 Re-Inspection · Commercial Dive Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3130389
17 October 2006 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2810074
15 February 2006 Plan Review (Other than "T")
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2585852
9 February 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2582252
14 January 2005 Annual Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2266676
14 January 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2274885
23 June 2004 MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2066432
5 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2060611
30 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997315
16 September 2003 Cargo Tank Internal · Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1906042
10 December 2002 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1716959
16 August 2002 Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1662241
9 November 2001 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1433916
7 October 2000 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1361757
11 May 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 817790
23 December 1999 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1049039
24 November 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1429330
30 March 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 655858
24 November 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 766760
25 October 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 195244
25 October 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 197433
7 October 1998 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1365145

Deficiency record · 123

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 April 2026 No resolution recorded
Maintenance, testing and inspections shall be carried out based on the guidlines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. Vessel's fixed CO2 system for engine room not hydro not conducted within 10 years; last hydro completed March 2014. SOLAS II-2/14.2.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 April 2026 No resolution recorded
Exhaust ducts from galley ranges shall be fitted with a grease trap readily removable for cleaning unless an alternative approved removal system is fitted. Vent duct cased/caked with grease. SOLAS II-2/9.7.5.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 10 April 2026 No resolution recorded
Fire Control Plans*;Plans and booklets shall be kept up to date. Door to galley incorrect or labled incorrectly on Fire Control Plan. Should be A-0 or B-15. SOLAS II-2/15.2.4.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2026 — due date passed with no resolution recorded
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 7 November 2023 Resolved
THE TRANSFER PROCEDURES REQUIRED BY 33 CFR 155.720 MUST BE AVAILABLE FOR INSPECTION BY THE COTP OR [name withheld] THE VESSEL IS IN OPERATION. VESSEL WAS UNABLE TO PRODUCE TRANSFER PROCEDURES TO PSCO. 33 CFR 155.740(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 20 November 2023
Resolution: Vessel provided transfer procedures upon request and made availble for inspection.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 7 November 2023 Resolved
THE OPERATION OF A VESSEL WITH A CAPACITY OF 250 OR MORE BARRELS OF OIL, HAZARDOUS MATERIAL, OR LIQUIFIED GAS AS REGULATED IN TABLE 4 OF 46CFR PART 154 SHALL PROVIDE TRANSFER PROCEDURES THAT MEET THE REQUIREMENTS OF THIS PART AND PART 156 OF THIS CHAPTER FOR TRANSFERRING FROM TANK TO TANK WITHIN THE VESSEL. VESSEL WAS UNABLE TO PROVIDE TRANSFER PROCEDURES TO VESSEL PERSONNEL. 33 CFR 155.720(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 28 November 2023
Resolution: Received updated transfer procedures.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 7 November 2023 Resolved
THE VESSEL OPERATOR OF EACH VESSEL REQUIRED BY 33 CFR 155.720 TO HAVE TRANSFER PROCEDURES SHALL MAINTAIN THEM CURRENT AND SHALL REQUIRE VESSEL PERSONNEL TO USE THE TRANSFER PROCEDURES FOR EACH TRANSFER OPERATION. VESSEL PIC WAS FOUND NOT USING TRANSFER PROCEDURES DURING TRANSFER. 33 CFR 155.730
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 November 2023
Resolved 29 February 2024
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 7 November 2023 Resolved
NO PERSON MAY TRANSFER OIL OR HAZARDOUS MATERIAL TO OR FROM A VESSEL UNLESS EACH PERSON IN CHARGE IS IN THE IMMEDIATE VICINITY AND IMMEDIATELY AVAILABLE TO THE TRANSFER PERSONNEL. PIC WAS FOUND TO NOT IN IMMEDIATE VICINITY OF TRANSFER. 33 CFR 156.160(c)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 November 2023
Resolved 29 February 2024
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 7 November 2023 Resolved
EACH PERSON IN CHARGE REQUIRED BY PARAGRAPH (5) OF THIS SECTION IS AT THE SITE OF THE TRANSFER OPERATION AND IMMEDIATELY AVAILABLE TO THE TRANSFER PERSONNEL. PIC WAS FOUND NOT IMMEDIATELY AVAILABLE OR ON SITE DURING PART OF THE TRANSFER. DIRECTLY RESULTING IN TANK OVERFILL. 33 CFR 156.120(t)(1)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 November 2023
Resolved 29 February 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 7 November 2023 Resolved
THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL SAFETY MANAGEMENT CODE. FOR THE PURPOSE OF THIS REGULATION THE REQUIREMENTS OF THE CODE SHALL BE TREATED AS MANDATORY. THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT NEW PERSONNEL TRANSFERRED TO NEW ASSIGNMENTS RELATED TO SAFETY AND PROTECTION OF THE ENVIRONMENT ARE GIVEN PROPER FAMILIARIZATION WITH THEIR DUTIES. IN ORDER TO PROPERLY MANAGE EFFICIENTLY A TOP PRIORITY IS TO IDENTIFY TRAINING NEEDS AMONGST VESSEL PERSONNEL. VESSEL BASED STAFF IS TO HAVE IN HOUSE TRAINING THAT WILL BE CONDUCTED ON BOARD THE VESSEL USING THE SMS. PSCO IDENTIFIED A LACK OF TRAINING RESOURCES IN RELATION TO TRANSFER PROCEDURES AND PIC DUTIES. INTERNAL ISM SMS AUDIT REQUIRED. SOLAS 74 (2020) IX/3.1 ISM CODE 6.3 SMS/6.5
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 December 2023
Resolved 29 February 2024
Resolution: Received and accepted internal audit of shipboard SMS.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 September 2020 Resolved
Each liferaft or group of liferafts shall be stowed witha float-free arrangement so that each floats free and if inflatable, automatically inflates when the ship sinks. Six life rafts were installed without painters attached to the weak link. 74SOLAS(14) Ch. III Reg 13.4.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2020
Resolved 17 September 2020
Resolution: 10c
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 September 2020 Resolved
The fire resistance of doors shall, as far as practicable, be equivalent to that of the division to which they are fitted. EDG/CO2 space door to AC room was wasted at bottom and had no gasket/seal between the spaces. 74 SOLAS (97) Ch. II-2 Reg 47.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2020
Resolved 21 October 2020
Resolution: Recevied ABS Survey Report number 4396049 from ABS Senior Surveyor which captured the deficiency as a condition of class. Cleared def iaw ACP TTP.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 September 2020 Resolved
Machinery space openings in position shall be properly framed and efficiently enclosed by steel casings of ample strength, and where the casings are not protected by other structures, their strength shall be specially considered. Access openings in such casings shall be fitted with doors complying with the requirements of regulation 12(1). WTD into E/R gasket was found to not seal and port Z-drive WTD was missing dog and did not seal properly. ICLL Ch. I Reg 17(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2020
Resolved 17 September 2020
Resolution: 10c
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 17 September 2020 Resolved
Ships shall follow the basic principles underlined in the 74SOLAS(97) Ch. II-2 having regard to the potential fire hazard involved: restricted use of combustible mate Aux. machinery space bilges had excessive amounts of oil soaked absorbent mats, the E/R bilges were found to be soaked with oil-residue. Remove excessive oil. 74 SOLAS(97) Ch. II-2 Reg 2.2.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2020
Resolved 17 September 2020
Resolution: 10c
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 17 September 2020 Resolved
Ladders shall be arranged to provide ready means of escape. The escape hatch from the E/R on the main deck was not labeled & not readily identifiable for immediate use. 74SOLAS(97) Ch. II-2 Reg 28.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2020
Resolved 17 September 2020
Resolution: 10c
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 September 2020 Resolved
Fire-fighting systems & appliances shall be kept in good working order & readily available for immediate use. The remote fuel shut off valves on the main deck weren't labeled & the "T" rod for actuating the valves was not immediately available. 74SOLAS(14) Ch. II-2 Reg 14
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2020
Resolved 17 September 2020
Resolution: 10c
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 17 September 2020 Resolved
Ships of 300 GT & greater must have a fixed containment under each fuel or oil tank vent. 3S fuel oil tank and waste oil tank vent containments were missing mechanical plugs. 33CFR155.320
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 17 September 2020
Resolved 17 September 2020
Resolution: 10c
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 17 September 2020 Resolved
A clear view through at least two of the navigation bridge windows shall be provided at all times, regardless of weather conditions. All Pilot house window wipers were in poor condition & were in need of maintenance/replacement. 74SOLAS(14) Ch. V Reg 22.9.9.4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: 10c
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 September 2020 Resolved
Maintenance, testing & inspection of lifesaving appliances shall be carried out in a manner having due regard to ensure reliability. 4 ring lifebuoys' light's batteries were 2 years past expiration the date. 74SOLAS(14) Ch. III Reg 20.3.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: 10c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 September 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Emergency bilge suction strainer wasted away. 74 SOLAS (14) Ch. I Reg 11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: Deficiency rectified to the satisfaction of the attending Coast Guard inspectors and ABS surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Port potable water tank sight glass located in bow thruster room needs to be a flat glass style since this tank shares a boundary with the shell plating below the waterline. Flat gauge glasses are to be fitted with a self-closing valve at each end and to be adequately protected from mechanical damage. 74 SOLAS (14) Ch.I Reg 11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 21 October 2020
Resolution: Recevied ABS Survey Report number 4396049 from ABS Senior Surveyor which captured the deficiency as a condition of class. Cleared def iaw ACP TTP.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Pre-lube oil pump for stbd engine was not isolated when emergency shutdown device was activated. Cooling water expansion tanks for port/stbd z-drives, fwd/aft bow thrusters, SSDG's 1-3, and the crane generator were found missing mechanical damage protective devices and valve wheels. Stbd tailshaft in the Z-drive room was found to have gease seal on the aft line shaft bearing loose and making improper noise when in operation. 74SOLAS(14) Ch. 1 Reg 11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 21 October 2020
Resolution: Recevied ABS Survey Report number 4396049 from ABS Senior Surveyor which captured the deficiency as a condition of class. Cleared def iaw ACP TTP.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2020 Resolved
Electrical installations shall be such that the the crew and ship shall be protected against electrical hazards. Electrical components, wiring and penetrations found in disrepair in following locations: stbd Z-drive room doors, overhead of the upper stairwell landing for entry into E/R from main deck, cable gland at bottom of hydraulic motor controller located above shore connection box stbd side of E/R, emergency steering station had exposed electrical components, shore power box on stbd side of E/R cover was missing and improper wire connections, stbd main pyrometer junction box was missing covering, knife switches for the battery banks A and B, located on the port side of the aux. machinery space were tied closed, and both the SSDG's and crane generator battery boxes had damaged ventilation tubes so as to allow ingress of water/fluids. 74SOLAS(04) Ch. II-1 Reg 40.1.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: 10c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2020 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. Main switchboard ground detection indicated large ground. 74SOLAS(04) Ch. II-1 Reg 45.1.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: 10c
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 September 2020 Resolved
Plans/booklets shall be kept up to date, any alterations being recorded thereon as soon as practicable. Main deck door to E/R, bow thruster room and port/stbd z-drive class A doors were missing self-closing devices. Multiple general alarm lights in E/R out. 74SOLAS(97) Ch. II-2 Reg 20.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 21 October 2020
Resolution: Recevied ABS Survey Report number 4396049 from ABS Senior Surveyor which captured the deficiency as a condition of class. Cleared def iaw ACP TTP.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 September 2020 Resolved
Fire-fighting systems & appliances shall be kept in good working order & readily available for immediate use. Fire-main developed hairline crack at immediate fire pump discharge piping. 74SOLAS(14) Ch. II-2 Reg 14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 17 September 2020
Resolution: 10c
14 - Pollution Prevention › 141 - MARPOL Annex I › Accidental oil outflow performance
Issued 17 September 2020 Resolved
The termination of sounding pipes are to be fitted with self-closing blanking devices and with self-closing control cock located below the blanking device for the purpose of ascertaining before the blanking device is opened so that oil fuel is not present. Provisions shall be made so as to ensure that any spillage of oil fuel through the control cock involves no ignition hazard. Sounding tubes, located in the engine room just fwd of the SSDG's, were found to have their self-closing devices tied open and missing plugs.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 17 September 2020
Resolved 17 September 2020
Resolution: 10c
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 September 2020 Resolved
The company must establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations with any additional requirements which may be established by the company. In meeting these requirements, the company must ensure that inspections are held at appropriate intervals, any non-conformity is reported, with its possible cause, appropriate corrective action is taken, and records of these activities are maintained. The inspections must be integrated into the ship's operational maintenance routine. The company shall conduct an internal audit of the ship's Safety Management System to ensure that the requirements of the ISM Code Clause 10 are properly implemented & shall provide a report to Marine Safety Unit Port [name withheld] Vessel Inspection Division and the responsible Recognized Organization issuing the vessel's Safety Management Certificate on behalf of the Coast Guard. ISM Code Clause 10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 21 October 2020
Resolution: Recevied ABS Survey Report number 4396049 from ABS Senior Surveyor which captured the deficiency as a condition of class. Cleared def iaw ACP TTP.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 January 2020 Resolved
No general alarm verbiage “when alarm sounds go to your station”
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2020
Resolved 9 September 2020
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 6 January 2020 Resolved
Main deck forward found base of superstructure to deck rusted threw.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2020
Resolved 9 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2020 Resolved
Machinery guards missing on several pieces of rotating machinery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 January 2020
Resolved 9 September 2020
Engineering › Thrusters › Motor
Issued 26 February 2016 Resolved
Make repairs to DP system & conduct satisfactory FMEA tests.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 1 November 2018
Resolution: Corrected.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 26 February 2016 Resolved
Make repairs to 40 ton deck crane & perform satisfactory tests prior to operation of crane.
Condition: Design Flaw
Due 26 April 2016
Resolved 1 November 2018
Resolution: Verified weight test of crane via ABS records.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 12 January 2016 Resolved
SMC in invalid
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2016
Resolution: Attended satisfactory audit for reissuance of SMC.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 October 2015 Resolved
Renew silencers in the exhaust system for both bow thrusters to the satisfaction of an attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 November 2018
Resolution: Vessel has chosen not to have DP notation until dive equipment is approved, and verifed by CG inspectors. At that time Class will conducte DP trials and when sat will request DP notation from Class.
Construction/Loadline › Structures › Ventilators
Issued 18 June 2014 Resolved
Make permanent repairs to the following vents: 3P Fuel, Bilge, BT FO Day Tank, and the 2C Fuel.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 27 June 2014
Resolution: Permanent repairs were made to the following vents: 3P Fuel, Bilge, BT FO Day Tank, and the 2C Fuel, all were satisfactory.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 18 June 2014 Resolved
Prove that the cable transit between the accomodation and machinery bulkehead is packed with fire retardent material.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 27 June 2014
Resolution: Rox-Blox was used for the cable transit between the accomodation and machinery bulkehead , and was found to be satisfactory.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 June 2014 Resolved
Provide a blank in the opening on the LDB 1 Panel in the engine room.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 23 June 2014
Resolution: A blanmk was provided in the opening on the LDB 1 Panel in the engine room.
Electrical › Electrical Distribution System (service) › Switch
Issued 18 June 2014 Resolved
Make repairs/replace the controller for the Z Drive Pump in the escape hatch.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 23 June 2014
Resolution: Proper repairs were made to the controller for the Z Drive Pump in the escape hatch.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2014 Resolved
Remove the extension cord in the medical room.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 18 June 2014
Resolution: The extension cord was removed from teh medical room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2014 Resolved
Remove the dead end wires in the following locations: in front of Pilot House, aft bulkhead inthe engine room, and under the generator in the tank farm.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 23 June 2014
Resolution: Dead end wires were removed in the following locations: in front of Pilot House, aft bulkhead inthe engine room, and under the generator in the tank farm
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 18 June 2014 Resolved
Provide an international shore connection.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 23 June 2014
Resolution: An international shore connection was provided.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 June 2014 Resolved
Secure the door for the PDB #4 panel.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 23 June 2014
Resolution: The door for the PDB #4 panel was secured.
Engineering › Generator (propulsion-electric) › Indicator Circuitry
Issued 18 June 2014 Resolved
Provide an RPM guage for the #1 generator.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 23 June 2014
Resolution: An RPM guage for the #1 generator was provided.
Engineering › Fuel Oil Service System › Valve, Control
Issued 18 June 2014 Resolved
Repair/replace the #2 F/O suction pump valve.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 23 June 2014
Resolution: The #2 F/O suction pump valve was repaired satisfactorily.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 June 2014 Resolved
Remove oil and clean the screen for the supply vent in the bow thruster room.
Action required: 705 - Other - as specified
Due 18 June 2014
Resolved 23 June 2014
Resolution: All oil was removed and the screen for the supply vent in the bow thruster room was cleaned satisfactorily.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 June 2014 Resolved
Replace the dryer vent hose on the dryer near the aft bulkhead.
Action required: 705 - Other - as specified
Due 18 July 2014
Resolved 23 June 2014
Resolution: The dryer vent hose on the dryer near the aft bulkhead was replaced with a servicable hose.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 June 2014 Resolved
Conduct fire, abandonship, and rescue boat drills.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2014
Resolved 23 June 2014
Resolution: Fire, abandon ship, and rescue boat drills were satisfactorily witnessed.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 30 May 2012 Resolved
Provide proof that the installed crane is certified for its intended use. Until such time, use of the crane is prohibited, IAW 46 CFR 126.130(b).
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2012
Resolved 13 September 2012
Resolution: Company provided a Register of Lifting Appliance and a Crane Annual Inspection Certificate from ABS, which verified the installation and testing of the crane, IAW 46 CFR 126.130(b).
Engineering › Steering Gear System › Power Unit
Issued 30 May 2012 Resolved
Repair/replace teh Z drive control panel on the engine room control station, IAW 46 CFR 127.120.
Action required: 705 - Other - as specified
Due 30 August 2012
Resolved 23 August 2012
Resolution: The z-drive control station in the E/R was replaced and tested satisfactory, IAW 46 CFR 127.120.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 30 May 2012 Resolved
Provide a list of all drawings submitted to MSC for all modifications from 2011 to present, IAW 46 CFR 127.120.
Action required: 705 - Other - as specified
Due 30 August 2012
Resolved 19 October 2012
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 30 May 2012 Resolved
Prove all outstanding comments on the MSC approval letters have been addressed from the modifications that have been completed from 2011 to present, IAW 46 CFR 127.120.
Action required: 705 - Other - as specified
Due 30 August 2012
Resolved 19 October 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 30 May 2012 Resolved
Replace the 1" pipe with 1.25" piping going from the last cylinder to the first nozzle in the newly installed CO2 system, IAW 46 CFR 128.110.
Action required: 705 - Other - as specified
Due 30 August 2012
Resolved 22 August 2012
Resolution: The 1" pipe for the newly installed CO2 system was replaced with the required 1.25" pipe going from the last cylinder to the first nozzle. System was tested and found to be in satisfactory condition.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 13 October 2011 Resolved
PROVIDE AN AUTOMATIC DOOR CLOSURE FOR THE FORWARD WTD LEAVING THE E/R. THE SPACE IS PROTECTED BY A FIXED CO2 SYSTEM.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 10 February 2012
Resolution: Sector Mobile has determined IAW subchapter L that this requirement is not a deficiency. Solas requires a automatic door closure on a passenger ship only. Subchapter L does not have any requirements for door closures.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 October 2011 Resolved
PROVE PROPER OPERATION OF THE O.W.S. ALL OILY WASTES TO BE MAINTAINED ONBOARD UNTIL REPAIR/REPLACEMENT IS MADE. OIL CONTENT METER IS UNRELIABLE.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 14 May 2012
Resolution: Proper testing/operation of a newly installed ODME and OWS were verified.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 13 October 2011 Resolved
PROVIDE R.P.M. GAUGES FOR #1,#2,#3 SSDGs.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 30 April 2012
Resolution: Witnessed proper operation on all 3 installed gauges.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 13 October 2011 Resolved
PROPERLY LABEL ALL MOTOR/CONTROLLERS IN E/R.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 14 May 2012
Resolution: All motor controlers were properly labeled in the engine room.
Construction/Loadline › Penetrations › Valve Flange
Issued 13 October 2011 Resolved
PERMANATELY BLANK OFF THE VENT OPENINGS IN ENGINE ROOM / THRUSTER SPACE WATER TIGHT BULKHEAD. PORT AND STARBOARD SIDES.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2011
Resolution: OPENNINGS WERE BLANKED OFF PRIOR TO DEPARTURE. OPENNINGS ARE TO BE PERMANATELY CLOSED DURING NEXT DRYDOCK.
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 13 October 2011 Resolved
PROVIDE ELECTRICAL MATTING IN FRONT OF EDG SWITCHBOARD.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 14 October 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 13 October 2011 Resolved
PROVIDE UPDATED CO2 PLACARDING, AND LEGIBLE OPERATING INSTRUCTIONS FOR THE FIXED FIREFIGHTING RELEASE STATION.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 30 March 2012
Resolution: Witnessed proper CO2 placards installed.
Engineering › Thrusters › Motor
Issued 13 October 2011 Resolved
PROVE PROPER OPERATION OF EMERGENCY STEERING FROM THE E/R CONTROL STATION.
Action required: 705 - Other - as specified
Due 13 December 2011
Resolved 5 July 2012
Resolution: Tested
Engineering › Steering Gear System › Power Unit
Issued 13 October 2011 Resolved
PROPERLY REPAIR & LABEL ALL BUTTONS & SWITCHES ON THE E/R CONTROL STATION PANEL.
Action required: 705 - Other - as specified
Due 30 August 2012
Resolved 23 August 2012
Resolution: All buttons and switches on the E/R control sttion panel for the azipods were labeled and installed correctly.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 October 2011 Resolved
HAVE AN APPROVED FCC RADIO TECHNICIAN ATTENDED THE VESSEL.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 30 April 2012
Resolution: Verified FCC radio technician report.
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 13 October 2011 Resolved
REPAIR OIL LEAKS ON #1 & #2 SSDG.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 14 May 2012
Resolution: The oil leaks on the #1 and #2 SSDG were reapired and the SSDG''s were operating satisfactorily.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 13 October 2011 Resolved
PROVIDE APPROVED TEST KITS ONBOARD FOR SERIOUS MARINE INCIDENT TESTING.
Action required: 705 - Other - as specified
Resolved 24 October 2011
Resolution: Rcvd documentation from vsl rep that the testing device had been placed onboard.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 13 October 2011 Resolved
PROVIDE AN APPROVED MARINE SANITATION DEVICE THAT WILL SERVICE THE NUMBER OF PEOPLE STATED ON THE VESSELS COI-(57).
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 30 April 2012
Resolution: Witnessed installation/operation and verified CG approved MSD onboard
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 October 2011 Resolved
PROVIDE DOCUMENTATION THAT THE VESSEL IS ENROLLED IN AN APPROVED DRUG AND ALCOHOL PROGRAM (DAPI).
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 30 April 2012
Resolution: Verified vessel is enrolled in DAPI
Documentation › Logs/Records › Oil Record Book
Issued 13 October 2011 Resolved
MAINTAIN THE NEWEST ADDITION OF THE OIL RECORD BOOK ONBOARD.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 10 February 2012
Resolution: Inspected and verified an approved Oil Record Book with a print date of January 2011
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 13 October 2011 Resolved
PROVIDE PROOF OF A GMDSS SHORE BASED RADIO MAINTENACE PROGRAM.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 30 April 2012
Resolution: Verified GMDSS shore based maintenance program is in place and being used.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 February 2011 Resolved
PROVIDE MISSING ROTATING GUARD FOR THE LOWER AIR COMPRESSOR UNIT IN THE E/R.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 30 April 2012
Resolution: Witnessed installed guard.
Engineering › Diesel Engine (auxiliary) › Waste Heat Recovery
Issued 23 February 2011 Resolved
PROVE PROPER OPERATION OF #3 SSDG.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 14 May 2012
Resolution: Proper operation of the #3 SSDG was proven satisfactorily.
Documentation › Logs/Records › Logbook (official)
Issued 23 February 2011 Resolved
MAINTAIN A CG OFFICIAL LOG BOOK ONBOARD.
Action required: 705 - Other - as specified
Due 31 December 2011
Resolved 30 April 2012
Resolution: Verified CG official log book is onboard and being used
Stability › Watertight Integrity › General
Issued 30 December 2008 Resolved
Adjust WTD's to maximize watertightness.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2008
Resolution: Doors adjusted properly.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 December 2008 Resolved
Lighting fixtures under the portable quarters were attached with rope. Attach fixtures correctly.
Due 30 January 2009
Resolved 31 December 2008
Resolution: Fixtures attached satisfactorily.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 30 December 2008 Resolved
Renew batteries in lanterns.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2008
Resolution: Batteries renewed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 30 December 2008 Resolved
Panel fwd of E/R was disassembled. Reassemble as necessary.
Due 30 January 2009
Resolved 31 January 2009
Resolution: Panel put back together.
Engineering › Fuel Oil Service System › Filter
Issued 30 December 2008 Resolved
All the filter bowls were full of fuel oil. Clean out all filter bowls.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 December 2008
Resolution: Filter bowls cleaned
Stability › Intact Stability (when using lifting gear) › General
Issued 19 May 2008 Resolved
Demonstrate satisfactory stability for the vessel with full outfit of Dive Gear, Support Equipment and maximum lifting and lufting constraints for the Crane.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2008
Resolved 5 June 2008
Resolution: Stability proved.
Documentation › Certificates/Documents › Diving System Safety Certificate
Issued 19 May 2008 Resolved
Provide all PVHO U-1-A's with specific information on all Pressure Vessel's to include the Closed Diving Bell, this will be (6) Pressure Vessel's.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2008
Resolved 31 December 2008
Resolution: U1-A''s provided.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 19 May 2008 Resolved
Provide CG approval for MSD on main deck port side, serving the portable quarters.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2008
Resolved 11 June 2008
Construction/Loadline › Structures › Deck Plating
Issued 19 May 2008 Resolved
Provide necessary documentation to clear all isues that remain outstanding with ABS and to re-issue documents. This is to include issuing all documents for the New Vessel name, Stability Manual updates, and Load-line survey.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2008
Resolved 11 June 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 January 2008 Resolved
Vessel has not received COI from Houston-Galveston. Temp COI due to expire on 22 FEB 2008.
Due 22 February 2008
Resolved 21 February 2008
Lifesaving › Rescue Boat › Markings
Issued 14 January 2005 Resolved
Replace retro reflective material on rescue boat.
Due 14 February 2005
Resolved 27 January 2005
Fire Fighting › International Shore Connection › Not on Board
Issued 14 January 2005 Resolved
Not on Board - Missing
Due 14 February 2005
Resolved 27 January 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 January 2005 Resolved
Prove navigation light on rescue boat.
Due 14 February 2005
Resolved 27 January 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 14 January 2005 Resolved
Provide CO2 servicing report with accurate bottle weights.
Due 14 February 2005
Resolved 27 January 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 January 2005 Resolved
Prove forward masthead light.
Due 14 February 2005
Resolved 27 January 2005
Navigation › Piloting/Steering › Marine Charts
Issued 14 January 2005 Resolved
Prove charts for vessels operating area are being updated (corrected).
Due 14 February 2005
Resolved 27 January 2005
Fire Fighting › Fire Hydrants › Location/Position
Issued 14 January 2005 Resolved
Properly label fire station.
Due 14 February 2005
Resolved 27 January 2005
Communications › Radio Communications › EPIRB
Issued 20 October 2003 Resolved
Renew EPIRB antenna.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2003
Resolved 20 October 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 October 2003 Resolved
Install grommet for stuffing tube on starboard bridge wing.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2003
Resolved 20 October 2003
Construction/Loadline › Structures
Issued 20 October 2003 Resolved
Adjust watertight door to main deck, engine room, adjust cooler watertight door and provide dogging wrench, and renew gasket for emergency generator room watertight door and bow thruster room. LEGACY COMPONENT DESC: Door
Action required: 17 - Rectify deficiencies prior to departure
Due 20 November 2003
Resolved 20 October 2003
Fire Fighting › Remote Fuel Shutoff
Issued 20 October 2003 Resolved
Label emergency generator remote fuel shut-off station. LEGACY COMPONENT DESC: Emergency Generator
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 20 October 2003
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 20 October 2003 Resolved
Provide appropriate fasteners for emergency generator room ventilation louver covers.
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 20 October 2003
Engineering › Fuel Oil Service System
Issued 20 October 2003 Resolved
Provide metal plugs on emergency generator for primary fuel filter bowl. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 20 October 2003
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 20 October 2003 Resolved
Place all flammables in paint locker.
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 20 October 2003
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 October 2003 Resolved
Provide updated fire safety plan for Coast Guard approval.
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 20 October 2003
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 October 2003 Resolved
Provide protective cover for range light.
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 20 October 2003
Engineering › Diesel Engine (auxiliary)
Issued 20 October 2003 Resolved
Renew starboard generator fuel oil supply hose. LEGACY COMPONENT DESC: Flexible Hose
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 20 October 2003
Documentation › Safety Management System
Issued 20 October 2003 Resolved
Provide proof of periodic test results in accordance with automated test procedures prior to operating with reduced manning. LEGACY COMPONENT DESC: Conformity Maintenance Procedures
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 20 October 2003
Lifesaving › Rescue Boat › Helm
Issued 20 October 2003 Resolved
Secure helm in rescue boat.
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 20 October 2003
Deck/Cargo
Issued 9 November 2001 Resolved
DEMONSTRATE PROPER OPERATION OF REMOTE STOP FOR #1 LIQUID MUD PUMP TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 December 2001
Resolved 10 December 2001
Lifesaving
Issued 9 November 2001 Resolved
PROVIDE AND POST REQUIRED IMO MARKINGS TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 9 December 2001
Resolved 20 October 2003
Lifesaving
Issued 7 October 2000 Resolved
PROVIDE MUSTER AND EMBARKATION ARRANGEMENTS TO COMPLY WITH 46CFR133.110 INCLUDING ILLUMINATION, LADDERS AND MARKINGS.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Documentation
Issued 7 October 2000 Resolved
PROVIDE APPROVED FIRE AND SAFETY PLAN ONBOARD. PLAN TO INCLUDE IMO SYMBOLOGY AS REQUIRED BY SOLAS.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Lifesaving
Issued 7 October 2000 Resolved
COMPLETE ITEMS 1-27 ISSUED AS WORKLIST ITEMS. CONTACT MSO NEW ORLEANS OVERSEAS CO-ORDINATOR TO SCHEDULE FOLLOW-UP VISIT AND DEFICIENCY CHECK.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Navigation
Issued 7 October 2000 Resolved
PROVIDE PROOF OF PROPER OPERATION AND DEMONSTRATE ENGINE ROOM PROPULSION/STEERING CONTROLS.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Lifesaving
Issued 7 October 2000 Resolved
ENSURE STENCILLING AND LABELING THROUGHOUT VESSEL MEETS THE REQUIREMENTS OF46CFR133.70 FOR LIFEBUOYS; 46CFR131.890 FOR SARTS; 46CFR131.865 FOR INFLATABLE LIFERAFTS. ALSO PROVIDE LAUNCHHING INSTRUCTIONS REQUIRED BY 46CFR133.90.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Navigation
Issued 7 October 2000 Resolved
PROVIDE 2 EA FCC LICENSED GMDSS OPERATORS ONBOARD.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Fire Fighting
Issued 7 October 2000 Resolved
PERFORM SERVICING OF VESSELS FIXED CO2 SYSTEM IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Lifesaving
Issued 7 October 2000 Resolved
PROVIDE 02 ADDITIONAL LIFE BUOYS AND ENSURE ATTACHMENTS TO ALL LIFE BUOYS COMPLY WITH 46CFR133.70.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Lifesaving
Issued 7 October 2000 Resolved
PROVIDE 03 ADDITIONAL LIFE PRESERVERS. VESSELS TOTAL PERSONS LIMITED TO 32UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Lifesaving
Issued 7 October 2000 Resolved
RESTORE RESCUE BOAT TO ORIGINAL CONFIGURATION AS REQUIRED BY APPROVAL SERIES 46CFR160.156 STIPULATED IN 46CFR133.135.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Documentation
Issued 7 October 2000 Resolved
PROVIDE ONE (1) ADDITIONAL ENGINEERING WATCHSTANDER FOR 24 HOUR MANNING OF THE ENGINEROOM UNTIL SUCH TIME AS THE ENGINEERING AUTOMATED CONTROL/MONITORING SYSTEM HAS BEEN RESTORED AS REQUIRED BY 46CFR130.400- 480.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Fire Fighting
Issued 7 October 2000 Resolved
PROVIDE PROOF OF BATTERY REPLACEMENT IN CYBERTRONICS SYSTEM 3 FIRE DETECTION PANEL.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Fire Fighting
Issued 7 October 2000 Resolved
PROVIDE PROOF OF TEST OF ALL COMPONENTS (PULL BOXES, SMOKE DETECTORS AND HEAT DETECTORS) OF FIRE DETECTION ALARM SYSTEM._x001C_
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Lifesaving
Issued 7 October 2000 Resolved
REMOVE ALL PAINT AND COMBUSTIBLE LIQUIDS FROM STARBOARD MAIN DECK LOCKER ORINSTALL FIXED FIRE EXTINGUISHING SYSTEM AS REQUIRED BY 46CFR132.310.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Documentation
Issued 7 October 2000 Resolved
PROVIDE CG APPROVED ENGINEERING AUTOMATED CONTROL/MONITORING SYSTEM PROCEDURES AS PER 46CFR137.110.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Lifesaving
Issued 7 October 2000 Resolved
INSTALL NEW ASME RELIEF VALVES OF THE PROPER PRESSURE SETTING FOR ALL 3 AIRRECEIVERS AND ON THE DISCHARGE PIPE OF THE LOWER AIR COMPRESSOR.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Construction/Loadline
Issued 7 October 2000 Resolved
PROVIDE DOCUMENTATION FOR THE ACCEPTANCE OF MOON POOL INSTALLATION BY CG AND / OR ABS.
Condition: Unknown
Due 7 October 2000
Resolved 7 October 2000
Navigation
Issued 24 November 1999 Resolved
SECONDARY FATHOMETER MUST BE REPAIRED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 December 1999
Resolved 21 April 2000
Documentation
Issued 24 November 1999 Resolved
A COPY OF THE VESSEL'S RADIO STATION LICENSE MUST BE PROVIDED TO MARINE SAFETY OFFICE MOBILE, AL.
Condition: Unknown
Due 24 December 1999
Resolved 21 April 2000
Documentation
Issued 24 November 1999 Resolved
VESSEL IS RESTRICTED TO DOMESTIC SERVICE UNTIL ORIGINAL COPIES OF SOLAS SHIP SAFETY CONSTRUCTION CERTIFICATE AND IOPP CERTIFICATE ARE ON BOARD.
Condition: Unknown
Due 24 December 1999
Resolved 21 April 2000
Deck/Cargo
Issued 7 October 1998 Resolved
SUBMIT CARGO SECURING MANUAL TO AMERICAN BUREAU OF SHIPPING FOR APPROVAL. VESSEL IS RESTRICTED TO DOMESTIC VOYAGES ONLY.
Condition: Unknown
Due 7 November 1998
Resolved 19 April 1999

Casualty record · 2

26 April 2012Routine · role: Acknowledged Pollution Source · activity 4307686
4 February 2014Routine · role: Acknowledged Pollution Source · activity 4796763
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

AMC AMBASSADOR (2012–2014). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.