Records from 1999 to 2026. Most recent: inspection, 11 February 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
11 February 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8309294
15 October 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8253097
25 February 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8084317
5 November 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8034801
4 December 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7833354
15 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7637313
17 October 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7580455
19 October 2021
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7335800
15 October 2021
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7326927
10 February 2021
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7136226
22 May 2020
Plan Review "T" Boat
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6957102
14 April 2020
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6938800
2 April 2020
Simplified Stability Test
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6931733
21 October 2019
Plan Review "T" Boat
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6840361
20 February 2019
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6628666
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200530
24 September 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3331717
4 December 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3109498
12 July 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2993420
6 July 2007
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2991838
14 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2961851
1 September 2006
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2765801
1 September 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2765922
1 September 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2813175
20 January 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2569921
5 July 2005
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2415284
4 June 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2091091
29 September 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1916273
19 June 2003
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1824508
30 May 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1623698
19 June 2001
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366502
8 August 2000
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1516916
19 July 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401281
10 June 1999
Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1375628
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2025
Resolved
13101 - The fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. The fuel shutoff did not close the valve entirely.
46 CFR 182.455(b)(4)
Action required: 10 - Deficiency Rectified
Resolved 15 October 2025
Resolution: The vessel owner adjusted the fuel shutoff valve to close completeley when actuated.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 October 2025
Resolved
04109 - The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Fire drills are not being completed every 3 months as required.
46 CFR 185.420(a)
Action required: 10 - Deficiency Rectified
Resolved 15 October 2025
Resolution: A fire drill was completed and logged in the presence of MIs.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 October 2025
Resolved
11132 - Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB is not being tested monthly.
46 CFR 185.728(a)
Action required: 10 - Deficiency Rectified
Resolved 15 October 2025
Resolution: An EPIRB test was completed and logged in the presence of MIs.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 December 2023
Resolved
Abandoned ship, man overboard, fire fighting drills, and EPIRB tests shall be logged or otherwise documented for review by the coast guard upon request. Vessel did not have any of the above logged as required.
Man overboard & Abandon Ship - At least within a 3 month period before vessel gets underway with passengers.
Fire Fighting - Conduct sufficient fire drills to make sure each crew member is familiar with their duties.
EPIRB Testing - must be tested monthly.
46 CFR 185.520(d)(2)
46 CFR 185.524(d)
46 CFR 185.728(c)
Action required: 10 - Deficiency Rectified
Resolved 4 December 2023
Resolution: Attending CG Marine Inspector went over drill and testing requirements to educate the mariner to the satisfaction that the requirements are known to the vessel operator.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 February 2023
Resolved
46 CFR 181.405(c) - Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with 181.450 installed in all enclosed areas where passengers and crew have routine access. Vessel does not have an interconnected fire detection system installed. Vessel's route isrestricted to limited coastwise or lesser until satisfactory interconnected fire detection system is installed.
Action required: 705 - Other - as specified
Resolved 21 February 2023
Resolution: Owner sent video evidence of installed interconnected smoke detectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 October 2021
Resolved
Electrical equipment on a vessel must be installed and maintained; green liquid found in battery box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2021
Resolved 19 October 2021
Resolution: Owner/operator submitted an image of the battery box without liquid in the bottom to meet standard.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 October 2021
Resolved
Each hydrostatic release unit must be serviced within 12 months of its manufacture and within 12 months of each subsequent servicing; hydrostatic release unit on starboard life raft expired.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 15 October 2021
Resolved 15 October 2021
Resolution: Replaced with used unit that expire after next annual servicing of lifesaving equipment. Briefed CID for approval regarding endorsement certificate provided by Vane Brothers for release.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 October 2021
Resolved
Relating to the floating waterlight, the Coast Guard reserves the right to make any inspection or test it deems necessary to determine the conformance of the floating waterlight to standard; waterlight containter contained moisture and corrosion on battery terminals to doubt seal.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 October 2021
Resolved 15 October 2021
Resolution: Dried light and conducted float test for watertight integrity to demonstrate compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 October 2021
Resolved
Each ring life buoy must be marked with Type II retroreflective tape approved in accordance with 46CFR164.018 and the arrangement must be as specified by IMO resolution A.658(16); amount of retroreflective tape on ring buoy does not meet standard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 October 2021
Resolved 15 October 2021
Resolution: Owner/operator replaced retroreflective tape on ring life buoy to meet standard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 October 2021
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operative station and the other at the access to the propulsion machinery space; batteries in portable battery light at operating station expired and light was dim.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 October 2021
Resolved 15 October 2021
Resolution: Batteries replaced to meet standard.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 15 October 2021
Resolved
A vessel that is issued a certificate of inspection must not be operated without a valid certification expiration date sticker; sticker not present on vessel.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 15 October 2021
Resolved 15 October 2021
Resolution: New inspection date expiration stickers provided at the conclusion of the certification inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 April 2020
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel. Open communication to the outside in the wheelhouse preventing weather tight integrity, missing window wiper motors.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2020
Resolved 27 April 2020
Resolution: Window wipers installed
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 14 April 2020
Resolved
Remote fuel shutoff stations must be marked indicating purpose of the valve and direction of operation. Fuel shut off valves missing signage.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2020
Resolved 27 April 2020
Resolution: Remote shutdown labeled.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 14 April 2020
Resolved
Placards containing instruction for the donning and use of the life jackets aboard the vessel must be posted visible to the crew and passengers. Lifejacket donning placard missing for all types used onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2020
Resolved 27 April 2020
Resolution: Downing placard installed.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 April 2020
Resolved
Vessel must be fitted with a suitable magnetic compass designed for marine use and illuminated. Magnetic compass missing light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2020
Resolved 27 April 2020
Resolution: Compass replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 April 2020
Resolved
Each life jacket carried on a vessel on oceans route must have a life jacket light. 17 Life jackets missing lights.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2020
Resolved 27 April 2020
Resolution: Missing lights installed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 April 2020
Resolved
Vessel must carry adequate and up-to-date charts. Chart correction kit missing.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2020
Resolved 27 April 2020
Resolution: Chart correction kit onboard.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 14 April 2020
Resolved
A durable placard must be posted next to all radiotelephone installations with emergency broadcast instructions. Emergency broadcast placard missing.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2020
Resolved 27 April 2020
Resolution: Emergency broadcast placard installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2020
Resolved
Pipe fittings in which the temperature exceeds 150 degrees Fahrenheit must be suitably insulated. Verify temperature on step attached to exhaust, insure engine has been given time to warm-up.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2020
Resolved 27 April 2020
Resolution: Step removed from exhaust.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 September 2006
Resolved
Certificate of Inspection expired June19, 2006. Vessel operated until August 13, 2006 with expired COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2006
Resolution: Issued Temp COI.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 4 June 2004
Resolved
Swinging compoass same day.
Condition: Placed in Improper Service
Due 4 June 2004
Resolved 4 June 2004
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 29 September 2003
Resolved
Ships horn was inoperable.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2003
Resolved 29 September 2003
Resolution: Fixed Horn connection
Lifesaving › Lifeboat Equipment › Oar
Issued 29 September 2003
Resolved
Tie down both 4' oars to their liferafts.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2003
Resolved 29 September 2003
Electrical › Electrical Distribution System (service)
Issued 29 September 2003
Resolved
Wooden board mounting all generator gauges was loose. LEGACY COMPONENT DESC: Panel board
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2003
Resolved 29 September 2003
Resolution: Remounted board to the mounting bracket
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 29 September 2003
Resolved
Replace batter box in engine room
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2003
Resolved 29 September 2003
Resolution: Replaced battery box with new box and spacers
Construction/Loadline › Structures
Issued 29 September 2003
Resolved
Replace one deck board that was causing a tripping hazard LEGACY COMPONENT DESC: Deck Plating
Condition: Improper Installation
Due 19 October 2003
Resolved 29 September 2003
Resolution: Replaced board with new board that fit better.
Deck/Cargo › Holds/Tanks
Issued 30 May 2002
Resolved
Replace flame screen in sewage holding tank vent. LEGACY COMPONENT DESC: Flame Arrester
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2002
Resolved 31 May 2002