Inspection record

Last inspected 4 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN4842
482267
Flag
UNITED STATES
Maury page id
psix-482267

Documentation record

Registered dimensions (L × B × D)42.0 ft × 15.0 ft × 5.0 ft
Registered tonnagegross 21 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMIDSHIP MARINE INC · HARVEY, LA, UNITED STATES · built 1999
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

18 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

4 May 2026 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8361597
2 June 2025 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8149926
21 March 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8097542
24 January 2025 Type not recorded
No type recorded · Station Cape Charles · USCG East District (CGD-E) · Activity 8070049
23 August 2024 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7987637
24 June 2024 COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7934311
18 January 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7848460
6 December 2023 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7838542
30 November 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7831931
17 April 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7670146
22 February 2023 Simplified Stability Test
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7643252
11 October 2022 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7563709
4 November 2021 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7340622
28 April 2021 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7183925
29 October 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7085802
23 August 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6792693
14 August 2019 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6776721
20 February 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6626760

Deficiency record · 21

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2024 Resolved
Each floating waterlight on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must allow the waterlight to be quickly disconnected from the ring life buoy. Waterlight lanyard did not have a clip. 46 CFR 180.70(d)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 1 July 2024
Resolution: O/O installed corrosion resistant clip on waterlight lanyard.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 June 2024 Resolved
Monthly inspections of portable fire extinguishers as required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel did not have records of monthly fire extinguisher inspections. 46 CFR 176.810(b)(1)(ii)/(iv)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 1 July 2024
Resolution: O/O recorded monthly fire extinguisher inspections in log book per requirements cited in def. description.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 June 2024 Resolved
The owner, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part. Vessel did not have record of crew training as required. 46 CFR 185.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 1 July 2024
Resolution: O/O recorded crew training in log book per requirements cited in def. description. Is aware of quarterly crew training requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 24 June 2024 Resolved
When lifefloats are stowed in tiers, the separate units must be kept apart by spacers. Lifefloats were not separated by spacers. 46 CFR 180.137(f)
Action required: 10 - Deficiency Rectified
Due 24 June 2024
Resolved 24 June 2024
Resolution: Vessel o/o installed plastic spacer blocks between lifefloats as required.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 31 January 2024 Resolved
Each collision bulkhead required by § 179.210, ) Must not be fitted with any type of penetration or opening except penetrations may be made if they are located as high and as far inboard as practicable and they have a means to make them watertight. Penetration on starboard side of collision bulkhead was not able to be made water tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 February 2024
Resolved 23 February 2024
Resolution: Vessel owner capped the collision bulkhead penetration on stbd side to make watertight, all sat.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 31 January 2024 Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF–DSC frequency transmitter meeting the requirements of § 80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz, Vessel has oceans route but did not have MF radio capability. Vessel restricted to operate within 20 nautical miles of land only. 47 CFR 80.905(a)(2)
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 23 February 2024
Resolution: Vessel owner installed Icom M-803 SSB radio with FCC technician, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 18 January 2024 Resolved
46CFR184.502: A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Sation license did not contain the correct MMSI number.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 31 January 2024
Resolution: Station license updated, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 18 January 2024 Resolved
47CFR80.159(e)(1) : Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator. None of the vessel operators obtained an operators permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 31 January 2024
Resolution: Capt. provided FCC operators permit, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 January 2024 Resolved
47CFR80.903 : Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel did not have FCC Safety Radiotelephone Certificate available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 31 January 2024
Resolution: FCC radio safety cert provided, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 18 January 2024 Resolved
46CFR184.410 : Vessel on an oceans route must be equipped with an electronic position fixing device, capable of providing accurate fixes for the area in which the vessel operates, to the satisfaction of the cognizant OCMI. Vessel did not have an updated GPS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 31 January 2024
Resolution: Vessel updated electronic charts including GPS, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 18 January 2024 Resolved
46CFR185.504 : The master of a vessel shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Vessel did not have a passenger count procedures available to the coast guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 31 January 2024
Resolution: Vessel provided passenger count procedures, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 January 2024 Resolved
46CFR180.137: Each life float must be individually attached to the painter by a line meeting and long enough that each life float can float without contacting any other life float or buoyant apparatus in the group. Not all life floats were individually attached by painter line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 31 January 2024
Resolution: Lifefloat painter lines were corrected, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 January 2024 Resolved
46CFR180.175(4) : The light must be attached around the body of the life float by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Light lanyard is less than 18 feet in length.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 31 January 2024
Resolution: Life float lanyard installed with correct length.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 January 2024 Resolved
46CFR180.137(f) : Life floats, when stowed in tiers, the separate units must be kept apart by spacers. Spacers were not present between stacked life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 31 January 2024
Resolution: Spacers were installed on lifefloats, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 January 2024 Resolved
46CFR182.100 : Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. STBD engine missing mount bolt on Aft STBD quarter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2024
Resolved 31 January 2024
Resolution: O/O installed new engine mount bolts, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 December 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported a loss of oil pressure on the port engine. Engine is removed from vessels and being overhauled. MI required tech report and operational test inspection prior to carriage of passengers. 46 CFR 182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2024
Resolved 18 January 2024
Resolution: Engine was installed, inspected and tested with annual inspection activity 7848460.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 November 2023 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in § 176.500(b)(1) and your Certificate of Inspection must be endorsed. 46 CFR 176.502 Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel is currently overdue for its annual inspection. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2024
Resolution: Annual inspection complete with activity 7848460.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 October 2020 Resolved
Vessel's bilge suction must be fitted with a suitable strainer. Install engine room bilge suction strainer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 13 November 2020
Resolution: Verified installation of strainer.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 29 October 2020 Resolved
Piping that exceeds 150 degrees Fahrenheit must be suitably insulated to prevent fire and injuries. Repair both engines' exhaust pipe insulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 13 November 2020
Resolution: Verified installation of insulation on both engines.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 October 2020 Resolved
Portable fire extinguishers must be installed satisfactory to the [name withheld] fire extinguisher bracket located on the aft deck support was waisted; replace bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 13 November 2020
Resolution: Verified replacement of wasted bracket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 August 2019 Resolved
46 CFR 183.320 A generator or motor designed for 40 degrees Celcius may be used in 50 degrees Celcius ambient locations provided the generator or motor is derated to 80% of the full load rating, and the rating of overcurrent devices is reduced accordingly. Vessel's generator did not have required nameplate attached. Generator must have nameplate containing information required by Article 445 of NFPA 70 and for a derated generator, the derated capacity. Attach appropraite generator nameplate and derate to 80% and the rating/setting of the overcurrent devices accordingly to the satisfaction of the attending USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 August 2019
Resolution: Provided proof that the generator had been derated and provided a photo of the manufacture nameplate had been attached to the SSDG.