Records from 1985 to 2002. Most recent: inspection, 15 October 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
15 October 2002
Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1899759
5 December 2001
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1389523
19 January 2000
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1386678
15 December 1998
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 808632
30 January 1998
Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1121576
11 December 1996
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1095659
11 January 1996
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1191980
8 December 1995
COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 877447
13 July 1994
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1176948
1 September 1993
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 827669
22 September 1992
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1250436
4 September 1991
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 940451
3 October 1990
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 932768
5 September 1990
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 904250
9 May 1990
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 917472
5 October 1989
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1020721
23 November 1988
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 898809
6 October 1987
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1324628
28 May 1987
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1310067
14 May 1986
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 986426
15 May 1985
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 977955
Construction/Loadline
Issued 5 December 2001
No resolution recorded
REPAIR HIGH LEVEL BILGE ALARM.
Condition: Unknown
Due 30 December 2001 — due date passed with no resolution recorded
Documentation
Issued 11 December 1996
Resolved
PROVIDE PROPER CERTIFICATE OF DOCUMENTATION TO RELECT CURRENT VESSEL OWNER.
Condition: Unknown
Due 11 December 1996
Resolved 11 December 1996
Fire Fighting
Issued 8 December 1995
Resolved
REPAIR/REPLACE ELECTRICAL FIRE PUMP TO PROVIDE ORIGINAL OUTPUT PRESSURE.
Condition: Unknown
Due 8 December 1995
Resolved 8 December 1995
Lifesaving
Issued 22 September 1992
Resolved
RENEW RETRO-REFLECCTIVE TAPE ON 55 LIFE PRESERVERS.
Condition: Unknown
Due 28 September 1992
Resolved 26 October 1992
Fire Fighting
Issued 5 September 1990
Resolved
PROVIDE COAST GUARD APPROVED BRACKET FOR THE "B-II" FIRE EXTINGUISHER.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Lifesaving
Issued 5 September 1990
Resolved
REMARK ALL LIFE PRESERVERS WITH VESSEL'S NAME.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Engineering
Issued 5 September 1990
Resolved
RENEW MAIN ELECTRICAL FUSE FOR THE STARBOARD PROPULSION MOTOR. FUSE LOCATED UNDER STEERING CONSOLE.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Lifesaving
Issued 5 September 1990
Resolved
PROPERLY MOUNT RING BUOY.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Construction/Loadline
Issued 5 September 1990
Resolved
STIFFEN THE DECK IN THE FOLLOWING AREAS: PORT SIDE, ADJACENT TO STEERING COMPARTMENT; STARBOARD SIDE, ADJACENT TO PROPELLER PACKING GLAND; PORT SIDEAT REAR OF MAIN MOTOR; STARBOARD SIDE, AT FORWARD STOWAGE LOCKER AND STARBOARD SIDE, FORWARD OF NUMBER FIVE SEAT.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Construction/Loadline
Issued 5 September 1990
Resolved
RENEW OR REFASTEN ALL 4-INCH BY 4-INCH ROPE HAND RAIL SUPPORT STANTIONS.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990