MAURY USCG vessel records Sign in
← All vessels

NEWPORT

NEWPORT is a 1998 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 1998, most recently in March 2007, along with 33 deficiencies.

Records from 1998 to 2007. Most recent: inspection, 16 March 2007.

Built
1998
Last inspected
16 March 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY7100
482287
Flag
UNITED STATES
—
Maury page id
psix-482287

Inspections, by type

…with no type recorded2
Years with a record 10 calendar years (1998–2007)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCY7100MMSI not assigned · expired · compulsorily equipped · granted 23 September 1998, cancelled 29 November 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 20

16 March 2007 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2889295
6 October 2006 COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2794945
27 September 2006 Examination of Repairs · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2787940
26 June 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2691763
14 October 2005 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2514589
30 September 2004 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2208574
21 September 2004 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2206431
3 September 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1906918
10 April 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1771610
30 September 2002 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1683303
26 September 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1680400
11 September 2001 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1432559
25 January 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1057111
7 September 2000 Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1461316
6 October 1999 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1399192
15 December 1998 Plan Review "T" Boat
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 807306
1 October 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 800955
11 September 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 800017
7 September 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 811157
1 September 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1445384

Deficiency record · 33

Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 October 2006 Resolved
Provide proof of fixed and portable Fire extinguisher Servicing Report.
Action required: 705 - Other - as specified
Due 26 October 2006
Resolved 27 October 2006
Resolution: fax
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 October 2006 Resolved
Prove proper operation of Ring Life Buoy water marker light.
Due 26 October 2006
Resolved 27 October 2006
Resolution: phone
Construction/Loadline › Hull › Hull Plating
Issued 27 September 2006 Resolved
Repair 17 areas of hull glass. See photos in case file.
Action required: 705 - Other - as specified
Resolved 12 October 2006
Resolution: phone
Engineering › Steering Gear System › Rudder
Issued 27 September 2006 Resolved
Provide rudder stops.
Action required: 705 - Other - as specified
Resolved 12 October 2006
Resolution: phone
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 27 September 2006 Resolved
Replace mounting clamps on fuel oil fill hose to tank.
Action required: 705 - Other - as specified
Resolved 12 October 2006
Engineering › Bilge Water Management System › Strainer
Issued 27 September 2006 Resolved
Replace strainer on bilge suction in #1 void.
Action required: 705 - Other - as specified
Resolved 12 October 2006
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 27 September 2006 Resolved
Properly seal cable ways (PVC Pipe) in engine room forward bulkhead.
Action required: 705 - Other - as specified
Resolved 12 October 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 27 September 2006 Resolved
Properly repair starboard aft engine room ventilation dampner.
Action required: 705 - Other - as specified
Resolved 12 October 2006
Resolution: phone
Engineering › Bilge Water Management System › Piping
Issued 27 September 2006 Resolved
Properly mount bilge piping in forward section #1 void.
Action required: 705 - Other - as specified
Resolved 12 October 2006
Resolution: phone
Engineering › Sea-water System (primary cooling) › Valve
Issued 27 September 2006 Resolved
Make port main engine sea water cooling valve operate freely.
Action required: 705 - Other - as specified
Resolved 12 October 2006
Resolution: phone
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 27 September 2006 Resolved
Permanently affix HIN number to vessel hull.
Action required: 705 - Other - as specified
Resolved 12 October 2006
Resolution: phone
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 October 2005 Resolved
Properly label all life jacket storage areas, size and quantity IAW 46 CFR 180.78
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 18 October 2005
Resolution: Received E-mail confirmation.
Fire Fighting › Fire Main › Pressure
Issued 6 October 2005 Resolved
Prove proper operation of fire main pump gauge.
Action required: 705 - Other - as specified
Due 20 October 2005
Resolved 18 October 2005
Resolution: Received E-mail confirmation.
Lifesaving › Lifefloat › Lifeline
Issued 30 September 2004 Resolved
Wasted grabline.
Condition: Improper/Lack of Maintenance
Due 30 September 2004
Resolved 30 September 2004
Construction/Loadline › Hull › Transverse Frame
Issued 21 September 2004 Resolved
Hole in the collision bulkhead. Notified Water Taxi of FT Lauderdale INC. of the deficiency on 27SEP04
Due 27 October 2004
Resolved 30 September 2004
Documentation › Safety/Response Plans/Programs
Issued 10 April 2003 Resolved
New generator with associated wiring installed without plan submittal. Four air handlers also found installed on overhead of vessel without proper approval or notification of alterations from OCMI as required by 46 CFR 176.700. LEGACY COMPONENT DESC: General Arrangement Plans
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2003
Resolution: Copmpleted new simplified stablity test issued new letter, completed plan review and exam of newe installation.
Engineering
Issued 7 September 2000 Resolved
INSTALL NATURAL VENTILATION VENT IN BATHROOM.
Condition: Unknown
Due 15 September 2000
Resolved 30 October 2000
Engineering
Issued 7 September 2000 Resolved
REPLACE FAULTY GAGE ON FIRE PUMP.
Condition: Unknown
Due 13 September 2000
Resolved 11 September 2000
Navigation
Issued 7 September 2000 Resolved
REPLACE CORRODED PIN ON STEERING TILLER ARM.
Condition: Unknown
Due 13 September 2000
Resolved 11 September 2000
Navigation
Issued 1 October 1998 Resolved
provide anchor ball
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Electrical
Issued 1 October 1998 Resolved
install metal wire hangers vice plastic wire ties.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Navigation
Issued 1 October 1998 Resolved
reverse bolt securing tiller bar to hyd ram on steering
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 1 October 1998 Resolved
install airsep check valves upright +/- 5 degrees fm vertical
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 1 October 1998 Resolved
provide double nuts/cotter pins on red gear and throttle to eng conn's
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Construction/Loadline
Issued 1 October 1998 Resolved
make operational bile pumps and "High water alarms".
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 1 October 1998 Resolved
install flame impingement bowl on racor F?O filter housings
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Electrical
Issued 1 October 1998 Resolved
provide guards over both MDE alternators.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Electrical
Issued 1 October 1998 Resolved
install stuffing tubes in watertight blkhds
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Lifesaving
Issued 1 October 1998 Resolved
provide 01 pfd (adult)
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Construction/Loadline
Issued 1 October 1998 Resolved
install "High Water" Bilge Alarms in fwd spaces
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Engineering
Issued 1 October 1998 Resolved
make operational red gear psi switchs for BMDE's
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Documentation
Issued 11 September 1998 Resolved
PRIOR TO 11 OCT 98, PROVIDE A FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998
Documentation
Issued 11 September 1998 Resolved
PRIOR TO 11 OCT 98, PROVIDE A FCC STATION LICENSE.
Condition: Unknown
Due 4 November 1998
Resolved 4 November 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.