Records from 2016 to 2025. Most recent: inspection, 12 December 2025.
Inspection history · 23
12 December 2025
Annual Inspection · Administrative Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8282028
10 July 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8182107
30 May 2024
COI Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7941779
5 January 2024
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7862604
16 March 2023
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7653780
22 June 2022
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7499323
3 June 2021
COI Inspection · Administrative Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7212068
17 February 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7169106
12 June 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6974868
14 October 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6885037
20 June 2019
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6717834
31 May 2019
Damage Survey
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6718412
4 May 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6684099
31 May 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6463910
3 July 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6228248
19 May 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6152716
6 March 2017
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6099870
1 March 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6096873
22 February 2017
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6093290
5 August 2016
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5963562
29 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5865409
7 April 2016
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5963534
4 April 2016
COI Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5846772
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 June 2020
Resolved
Each change in design, material, or construction from the plans approved under 46CFR159.005-13 and 46CFR160.135-13(h) must be approved by the COMDT. Removal of approved starting system by palfinger must be supported by authorization by COMDT or spring starting system must e reinstalled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2020
Resolved 13 July 2020
Resolution: [name withheld] submitted documentatation for the clearance.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2020
Resolved
Emergency evacuation plan required by 33CFR Part 146 shall have a record of changes. Record of changes provided lists none of the changes noted in EEP book. Update record of changes or resubmit as you see fit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2020
Resolved 12 July 2020
Resolution: [name withheld] submitted documentatation for the clearance.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 12 June 2020
Resolved
The garbage managment plan required by 33CFR151.51 required recordkeeping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 17 July 2020
Resolution: [name withheld] submitted documentatation for the clearance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 June 2020
Resolved
OEM maintenance not being used for weekly, monthly, quarterly, or annual. Harmonize winch, davit, relasing gear, and boat. 33CFR146.15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2020
Resolved 12 July 2020
Resolution: [name withheld] submitted documentatation for the clearance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 June 2019
Resolved
All vessels..shall be provided with a satisfactory bilge pumping plant. Multiple hydraulic actuators in the ballast/bilge system have hydraulic leaks. Check and repair all leaking valves to the satisfactory of the attending marine inspector. Contact USCG with a repair plan if unable to meet action requirement.
46 CFR 56.50-50
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 22 July 2019
Resolution: Received email from [name withheld] as well as Controlworx Field servoce ticket showing repairs of two valves and satisfactory testing of 62 valves.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 31 May 2019
Resolved
As a result of boom collapse, #3 crane is not currently installed in accordance with CG-approved plans required by 46CFR 107.309. Submit securing and repair plans.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2019
Resolved 6 August 2019
Resolution: Crane boom was replaced-in-kind and subjected to satisfactory load testing and post-tet NDT. Crane placed back into service and is again in compliance with approved plans.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 May 2018
Resolved
Lifeboat air regulator was blowing by. Lifeboat #3.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2018
Resolved 8 June 2018
Resolution: Unit's regulatory rep provided info to clear item.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 May 2018
Resolved
Emergency lights were not marked with "E".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2018
Resolved 2 July 2018
Resolution: Recieved email from unit stating def has been cleared. Email loaded into docs section.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 19 May 2017
Resolved
Unit's Fire Detection system used for Portable Quarters units had alarms/faults on the panel that could not be cleared. Determine root cause and report findings.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 24 May 2017
Resolution: Received email from [name withheld] with picture that Fire Control Panel is now fault free. Faults occurred due to removal of portable quarters. Missing buildings caused faults. Engineer identified and corrected.
Lifesaving › Lifeboat › Exhaust Pipe
Issued 7 April 2016
Resolved
Life boats #3/4 exhaust are leaking into cabin and need repaired prior to use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 12 April 2016
Resolution: Pipes replaced. Cleared def.
Fire Fighting › Fire Hydrants › Condition
Issued 7 April 2016
Resolved
AFFF pick up tubes are cracked and need replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 26 May 2016
Resolution: Replaced all tubes.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 7 April 2016
Resolved
Latch for laundry shoot not working properly and needs replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 26 May 2016
Resolution: Latch/door repaired.
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 7 April 2016
Resolved
Fire team is required to show proficiency of proper fire drill.
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 26 May 2016
Resolution: Fire drill conducted all sat.
Lifesaving › Lifeboat › Exhaust Pipe
Issued 7 April 2016
Resolved
Exhaust leaking in lifeboat 3 and 4 required repair prior to use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 26 May 2016
Resolution: Leaks repaired and tested.
Fire Fighting › Fire Hydrants › Condition
Issued 7 April 2016
Resolved
Hose for pick up tube on AFFF is cracking and needs replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 26 May 2016
Resolution: AFFF tubes replaced.
Construction/Loadline › Structures › Door
Issued 7 April 2016
Resolved
Laundry shoot door does not latch. Required to latch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 26 May 2016
Resolution: Door sdjusted.
Operations/Management › Drills/Instruction › Fire
Issued 7 April 2016
Resolved
Crew did not respond to fire in laundry room satisfactory. Required to perform adequate frie drill.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 26 May 2016
Resolution: Fire drill conducted sat.