MAURY USCG vessel records Sign in
← All vessels

BRUTUS TLP

BRUTUS TLP is a 2001 industrial vessel. The Coast Guard has recorded 65 inspections since 1998, most recently in December 2025, along with 32 deficiencies and 3 casualty investigations between 2006 and 2013.

Records from 1998 to 2025. Most recent: inspection, 12 December 2025.

Built
2001
Last inspected
12 December 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ5183
482387
Flag
UNITED STATES
—
Maury page id
psix-482387

Inspections, by type

…with no type recorded14
Years with a record 25 calendar years (1998–2025)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 65

12 December 2025 Annual Inspection · Administrative Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8282028
10 July 2025 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8182107
30 May 2024 COI Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7941779
5 January 2024 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7862604
16 March 2023 Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7653780
22 June 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7499323
3 June 2021 COI Inspection · Administrative Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7212068
17 February 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7169106
12 June 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6974868
14 October 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6885037
20 June 2019 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6717834
31 May 2019 Damage Survey
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6718412
4 May 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6684099
31 May 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6463910
3 July 2017 Administrative Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6228248
19 May 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6152716
6 March 2017 Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6099870
1 March 2017 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6096873
22 February 2017 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6093290
5 August 2016 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5963562
29 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5865409
7 April 2016 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5963534
4 April 2016 COI Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5846772
20 June 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4936696
27 May 2014 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4871259
29 May 2012 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4327030
24 September 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3856387
8 September 2010 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3883441
1 December 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3645869
9 July 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3530176
27 February 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3425482
26 December 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3388666
10 November 2008 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3360714
15 September 2008 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3325244
7 September 2007 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3051531
23 July 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3005076
18 October 2006 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2803143
8 September 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2833862
23 June 2006 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2688971
1 May 2006 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2637688
25 August 2005 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2496270
14 June 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2390506
13 May 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2356889
19 April 2005 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2337565
3 September 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2185608
3 March 2004 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2023753
28 October 2003 Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1943874
29 August 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1890790
20 August 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1664614
16 July 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1647254
8 May 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1620591
25 February 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1618029
22 October 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 100694
8 September 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 98206
28 August 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1072793
3 July 2001 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075016
3 July 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467780
23 May 2001 Initial Certification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1469664
5 March 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1062902
14 February 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059602
23 October 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397507
26 July 2000 Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429393
11 May 2000 Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399369
13 September 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783691
29 September 1998 Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402713

Deficiency record · 32

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 June 2020 Resolved
Each change in design, material, or construction from the plans approved under 46CFR159.005-13 and 46CFR160.135-13(h) must be approved by the COMDT. Removal of approved starting system by palfinger must be supported by authorization by COMDT or spring starting system must e reinstalled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2020
Resolved 13 July 2020
Resolution: [name withheld] submitted documentatation for the clearance.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2020 Resolved
Emergency evacuation plan required by 33CFR Part 146 shall have a record of changes. Record of changes provided lists none of the changes noted in EEP book. Update record of changes or resubmit as you see fit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2020
Resolved 12 July 2020
Resolution: [name withheld] submitted documentatation for the clearance.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 12 June 2020 Resolved
The garbage managment plan required by 33CFR151.51 required recordkeeping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2020
Resolved 17 July 2020
Resolution: [name withheld] submitted documentatation for the clearance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 12 June 2020 Resolved
OEM maintenance not being used for weekly, monthly, quarterly, or annual. Harmonize winch, davit, relasing gear, and boat. 33CFR146.15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2020
Resolved 12 July 2020
Resolution: [name withheld] submitted documentatation for the clearance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 June 2019 Resolved
All vessels..shall be provided with a satisfactory bilge pumping plant. Multiple hydraulic actuators in the ballast/bilge system have hydraulic leaks. Check and repair all leaking valves to the satisfactory of the attending marine inspector. Contact USCG with a repair plan if unable to meet action requirement. 46 CFR 56.50-50
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 22 July 2019
Resolution: Received email from [name withheld] as well as Controlworx Field servoce ticket showing repairs of two valves and satisfactory testing of 62 valves.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 31 May 2019 Resolved
As a result of boom collapse, #3 crane is not currently installed in accordance with CG-approved plans required by 46CFR 107.309. Submit securing and repair plans.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2019
Resolved 6 August 2019
Resolution: Crane boom was replaced-in-kind and subjected to satisfactory load testing and post-tet NDT. Crane placed back into service and is again in compliance with approved plans.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 May 2018 Resolved
Lifeboat air regulator was blowing by. Lifeboat #3.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2018
Resolved 8 June 2018
Resolution: Unit's regulatory rep provided info to clear item.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 May 2018 Resolved
Emergency lights were not marked with "E".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2018
Resolved 2 July 2018
Resolution: Recieved email from unit stating def has been cleared. Email loaded into docs section.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 19 May 2017 Resolved
Unit's Fire Detection system used for Portable Quarters units had alarms/faults on the panel that could not be cleared. Determine root cause and report findings.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 24 May 2017
Resolution: Received email from [name withheld] with picture that Fire Control Panel is now fault free. Faults occurred due to removal of portable quarters. Missing buildings caused faults. Engineer identified and corrected.
Lifesaving › Lifeboat › Exhaust Pipe
Issued 7 April 2016 Resolved
Life boats #3/4 exhaust are leaking into cabin and need repaired prior to use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 12 April 2016
Resolution: Pipes replaced. Cleared def.
Fire Fighting › Fire Hydrants › Condition
Issued 7 April 2016 Resolved
AFFF pick up tubes are cracked and need replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 26 May 2016
Resolution: Replaced all tubes.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 7 April 2016 Resolved
Latch for laundry shoot not working properly and needs replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 26 May 2016
Resolution: Latch/door repaired.
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 7 April 2016 Resolved
Fire team is required to show proficiency of proper fire drill.
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 26 May 2016
Resolution: Fire drill conducted all sat.
Lifesaving › Lifeboat › Exhaust Pipe
Issued 7 April 2016 Resolved
Exhaust leaking in lifeboat 3 and 4 required repair prior to use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 26 May 2016
Resolution: Leaks repaired and tested.
Fire Fighting › Fire Hydrants › Condition
Issued 7 April 2016 Resolved
Hose for pick up tube on AFFF is cracking and needs replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 26 May 2016
Resolution: AFFF tubes replaced.
Construction/Loadline › Structures › Door
Issued 7 April 2016 Resolved
Laundry shoot door does not latch. Required to latch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 26 May 2016
Resolution: Door sdjusted.
Operations/Management › Drills/Instruction › Fire
Issued 7 April 2016 Resolved
Crew did not respond to fire in laundry room satisfactory. Required to perform adequate frie drill.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 26 May 2016
Resolution: Fire drill conducted sat.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 29 May 2012 Resolved
Service the air bottles on all lifeboats.
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 13 July 2012
Resolution: Received statement from OIM, completed..
Lifesaving › Lifeboat › Markings
Issued 29 May 2012 Resolved
Provide overhead markings of the lifeboat # & vessel's name.
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 17 June 2012
Resolution: Received statement from OIM, completed..
Lifesaving › Lifeboat › Markings
Issued 29 May 2012 Resolved
Replace the reflective tape on lifeboats #2 & 4.
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 24 June 2012
Resolution: Received statement from OIM, completed.
Lifesaving › Launching Appliances › Davit
Issued 29 May 2012 Resolved
Provide operating instructions next to each davit for each lifeboat & rescue boat.
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 1 July 2012
Resolution: Received statement from OIM, completed.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 29 May 2012 Resolved
Repair to diaphram for #2 Lifeboat's air system.
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 22 June 2012
Resolution: Received statement from OIM, completed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 May 2012 Resolved
Reconfigure the bouy line boxes to be able to inspect the lines.
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 13 July 2012
Resolution: Received statement from OIM, completed..
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 29 May 2012 Resolved
Provide OIM statement that the shutdowns were completed on #2 genset for the rig package to include: Low L/O, Overspeed, & high temp.
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 13 July 2012
Resolution: Received statement from OIM, completed..
Lifesaving › Lifeboat › Markings
Issued 29 May 2012 Resolved
Provide a long-term service plan to refurbish the coloring of Lifeboats #2 & 4 that is acceptable to the OCMI; complete one lifeboat refurbish w/in the next 12 months.
Action required: 705 - Other - as specified
Due 13 June 2013
Resolved 19 June 2013
Resolution: L/B''s were inspected during the 2013 inspection and found that the unit had polished the L/B''s #2 and #4 to bring the color back out.
Lifesaving
Issued 23 May 2001 Resolved
CONDUCT RESCUE BOAT DRILL/MAN OVERBOARD DRILL UPON ARRIVAL TO MORGAN CITY [name withheld]/LOG AND CONDUCT ANOTHER IN THE PRESENCE OF ATTENDING USCG MARINE INSPECTOR AT EARLIEST POSSIBLE DATE.
Condition: Unknown
Due 23 May 2001
Resolved 23 May 2001
Unknown
Issued 23 May 2001 Resolved
COMPLETE ITEMS 4, 6, 8, 13 & 14 ON WORK LIST ISSUED TO H & P RIG PACKAGE ON27APR01 TO SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 23 May 2001
Resolved 23 May 2001
Lifesaving
Issued 23 May 2001 Resolved
#4 TURBINE SHALL NOT BE UTILIZED UNTIL ALL TEST ARE CONDUCTED IAW 46 CFR 58.10-15 TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR AND FM-200 SYSTEM TO THIS TURBINE (FORGOTTEN BY DOOLEY TACKLEBERRY) IS TESTED TO THE SATISFACTION OF COGNIZANT OCMI MARINE INSPECTION OFFICE.
Condition: Unknown
Due 23 May 2001
Resolved 23 May 2001
Fire Fighting
Issued 23 May 2001 Resolved
PROVE PROPER OPERATION OF FM-200 EXTINQUISHING SYSTEM IN THE SCR ROOM ON RIG ABOVE THE EMD CONTROL ROOM TO THE SATISFACTION OF COGNIZANT [name withheld].
Condition: Unknown
Due 23 May 2001
Resolved 23 May 2001
Fire Fighting
Issued 23 May 2001 Resolved
TEST APPLICABLE GAS DETECTION ALARMS ON TLP (TEMP QURTS, RIG, ACCOM) PRIOR TO DRILLING AND TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 23 May 2001
Resolved 23 May 2001
Fire Fighting
Issued 23 May 2001 Resolved
TEST FIRE MAIN BOOSTER PUMPS TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR AND PRIOR TO CONDUCTING HELICOPTER FUELING OPERATIONS.
Condition: Unknown
Due 23 May 2001
Resolved 23 May 2001
Fire Fighting
Issued 23 May 2001 Resolved
HELICOPTER FUELING STATION (EMERGENCY SHUT-DOWNS) TO BE TESTED TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR PRIOR TO CONDUCTING HEICOPTER FUELING OPERATIONS OR LOADING AVIATION FUEL INTO TANK.
Condition: Unknown
Due 23 May 2001
Resolved 23 May 2001

Casualty record · 3

8 September 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2833862
4 May 2010Routine · role: Involved in a Marine Investigation (non-casualty) · 1 dead · activity 3775382
2 November 2013Routine · role: Involved in a Marine Casualty · activity 4747107
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record