13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2026
Resolved
Exhaust piping shall be gas tight throughout its length and shall be properly supported by non-combustible hangers or blocks. MI observed leak in aluminum piping allowing cooling water to leak into steering compartment.
46 CFR 182.15-20(a)
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 5 February 2026
Resolution: Vessel replaced section of exhaust pipe.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 January 2026
Resolved
Primary consideration shall be given to the provision of a seaworthy hull, protection against fire, means of escape, guards and rails in hazardous places, etc. MI observed a pit just under 1/4" on port side of keelson just aft side of class-1 water tight door. Clean pit and cover with corrosion arresting coating.
46 CFR 177.01-5
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 17 February 2026
Resolution: Owner coated pit with Pro Lite body filler to slow corrosion.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2026
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Starboard side M/E and G/E are missing covers for engine driven belts.
46 CFR 177.35-15
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 5 February 2026
Resolution: Suitable guards were placed over rotating machinery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2026
Resolved
That part of the exhaust system between the point of cooling water injection and the engine manifold shall be water-jacketed or effectively insulated. Both of the vessel's G/E exhaust pipes are missing insulation between the turbo and cooling water injector.
46 CFR 182.15-15(b)(3)
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 5 February 2026
Resolution: Uncovered portion of exhaust was wrapped in insulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2026
Resolved
The discharge ends of vent pipes shall be fitted with removable flame screen or flame arresters. Fuel tank vent is missing flame screen.
46 CFR 182.20-35(d)
OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 5 February 2026
Resolution: Owner placed flame screen over vent.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 January 2026
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Labeling for child life jackets are not appropriately marked.
46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 5 February 2026
Resolution: Child life jackets were properly stenciled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 January 2025
Resolved
Fire hoses must be lined commercial fire hose that conforms to UL std. 19 or Federal Specification ZZ-H-451E. The port side fire hose had several leaks. Replace fire hose.
46 CFR 181.15-10(d)(1) Old T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 4 February 2025
Resolution: Type approved fire hose attached to port side fire station.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 January 2025
Resolved
A length of fire hose shall be attached to each fire hydrant at all times. Vessel had washdown hoses attached to fire hydrants and not correct fire hoses. Attach correct fire hoses to hydrants. 46 CFR 181.1510(g) Old T
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 4 February 2025
Resolution: Attached fire hose to fire station.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 January 2025
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The vessel master could not provide a medical certificate from the Coast Guard. Provide a valid medical certificate to the cognizant OCMI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2025
Resolved 1 March 2025
Resolution: Confirmed master's license issued as valid.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 January 2025
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: “EMERGENCY EXIT KEEP CLEAR”. None of the emergency escape hatches were marked. Mark all emergency escape hatches.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 4 February 2025
Resolution: Emergency exits marked.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 January 2025
Resolved
Watertight doors shall be marked on both sides in 1-inch letters: WATERTIGHT DOOR- CLOSE IN EMERGENCY”. Watertight door was not marked. Mark watertight door as required.
46 CFR 185.30-25(a) Old T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 4 February 2025
Resolution: Watertight door properly marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2025
Resolved
For each watertight door which is in a required subdivision bulkhead, an indicator light must be installed in the pilothouse and at each other vessel operating station from which the door is not visible. The indicator must show whether the door is open or closed. The indicator light was inoperable. Repair light to indicator to indicate whether the door is open or closed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 January 2025
Resolved 28 January 2025
Resolution: Indicator light repaired and operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2025
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. The markings for the number of passengers allowed on the upper deck was no longer visible. Replace required markings for maximum number of passengers allowed on the upper deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 28 January 2025
Resolution: Upper deck passenger count marked at top of ladderway, visible to all passengers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 January 2025
Resolved
All electrical equipment, including distribution panels, shall be so constructed or protected and cannot be inadvertently touched nearer than a safe distance by any person. Blank covers on the forward engine room distribution panel were missing. Place blanks over all exposed overcurrent device locations on distribution panel. 46 CFR 183.10-10(a) Old T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 28 January 2025
Resolution: Blank covers installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 January 2025
Resolved
Any panel in excess of 24 volts shall be fitted with a permanent sign warning personnel of this condition and identifying the circuits to be disconnected to remove all potentials in excess of 24 volts. All circuits on the distribution panel located on the main deck engine room passage were not marked to identify the loads they serve. 46 CFR 183.10-10(c) Old T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 28 January 2025
Resolution: Panel properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 January 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Placards for donning instructions were not available on the upper deck for passengers to observe, and one placard on the main deck pertained only to kapok type PFD’s. Remove the kapok specific placard, and place a placard for donning instructions on the upper deck where passengers can observe it.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 28 January 2025
Resolution: O/O posted a donning placard on upper deck.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 January 2025
Resolved
Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. Reflective tape on life floats were worn. Replace with new retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 28 January 2025
Resolution: o/o replaced retro tape on all BA's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 January 2025
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. The lanyard on the ring life buoy was found short of 3 feet and attached to the hand grab. Replace lanyard with line between 3 and 6 feet long when attached around the body of the life buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 28 January 2025
Resolution: Ring life buoy light lanyard replaced at proper length and attached around body of ring buoy.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 January 2025
Resolved
An inspection is required before the issuance of a Certificate of Inspection. The vessels COI is expired. Receive a valid COI prior to operation and carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2025
Resolution: Issued COI after sucessful COI inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 22 adult PFD's were found unservicable and destroyed in the presence of the marine inspector. Replace PFD's to satisfy the requirement for the total number of passengers allowed by the COI.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 January 2025
Resolution: PFD's onboard presently satisfy the cold water carriage requirements, the unservicable PFD's were identified and destroyed in the presence of the MI.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 January 2024
Resolved
VESSELS MUST BE EQUIPPED WITH A MASTER KEY CONTROL SYSTEM FOR PHYSICAL, MANUAL, OR ELECTRONIC KEYS OR ACCESS SYSTEMS, WHICH PROVIDES CONTROLLED ACCESS TO ALL COPIES OF THE VESSEL'S MASTER KEY. FOUND NO RECORD/LOG BOOK FOR MASTER KEY. VESSEL HAS 02 DOORS THAT REQUIRE LOCK & KEY. O/O CREATED A LOG BOOK TO TRACK MASTER KEY ACCESS & IDENTIFY CREWMEMBERS IN THE MASTER KEY CONTROL SYSTEM. 01 KEY GOES TO THE DECKHAND & 01 KEY GOES TO THE MASTER.
Action required: 10 - Deficiency Rectified
Due 18 January 2024
Resolved 18 January 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 January 2024
Resolved
THE MINIMUM CAPACITY OF THE POWER FIRE PUMP SHALL BE 50 GALLONS PER MINUTE AT A PRESSURE OF NOT LESS THAN 60 LBS PER SQUARE IN AT THE PUMP OUTLET. THE PUMP OUTLET SHALL BE FITTED WITH A PRESSURE GUAGE. MI'S FOUND FIRE PUMP NOT FITTED WITH A PRESSURE GAUGE. INSTALL PRESSURE GUAGE AT THE PUMP OUTLET.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2024
Resolved 1 February 2024
Resolution: O/O provided pictures of installed pressure gauge at the pump outlet.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 18 January 2024
Resolved
ALL VESSELS EXCEPT NON-SELF-PROPELLED VESSELS SHALL BE PROVIDED WITH SUITABLE STERRING APPARATUS. DISCOVERED LEAKING SEAL ON STEERING RAM DURING CHECKS. REPLACE/REPAIR SEAL ON STEERING RAM.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2024
Resolved 1 February 2024
Resolution: O/O Provided pictures of newly installed steering ram system.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 January 2024
Resolved
EACH VESSEL THAT OPERATES ON THE HIGH SEAS, OR BEYOND THREE MILES FROM THE COASTLINE MUST HAVE ON BOARD A FCC TYPE ACCEPTED CATEGORY 1 EPIRB. FOUND EPIRB HYDROSTATIC RELEASE MISSING EXPIRATION DATE. PROVIDE DOCUMENTATION ON HYDROSTATIC RELEASE INSTALLATION DATE OR REPLACE HYDROSTATIC RELEASE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2024
Resolved 1 February 2024
Resolution: O/O Purchased new hydrostatic release for EPIRB & provided pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 January 2024
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Found ring life buoy missing float light. Add float light to ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2024
Resolved 1 February 2024
Resolution: O/O Provided picture of float light attached to life ring buoy.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 January 2023
Resolved
Pitting was identified along 3 frames (along chine and one longitudinal frame above chine) on port side shell boiler room and cracked weld in forpeak starboard side. Provide repair proposal to crop and renew side shell plating that was identified to exceed 25% degradation, provide original scantlings and repair cracked weld on longitudinal frame.
Action required: 705 - Other - as specified
Due 25 March 2023
Resolved 6 February 2023
Resolution: Vessel owner cropped and reneewed pitting area identified. (See pictures)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 January 2023
Resolved
The bilge pipe piercing the collision bulkhead shall be fitted with a screw down valve on the forward side of the collision bulkhead and operable from the weather deck. Valve head was broken, replace broken valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2023
Resolved 6 February 2023
Resolution: Vessel owner replaced valve in forpeak.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 18 January 2022
Resolved
47 CFR 80.1005
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Vsl's Federal Communications Commission Bridge-to-Bridge Certificate is expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 27 January 2022
Resolution: Vessel provided Bridge-to-Bridge Certificate.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 18 January 2022
Resolved
47 CFR 80.903
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vsl does not have a Federal Communications Commission Safety Safety Radiotelephony Certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 27 January 2022
Resolution: Vessel provided Safety Radiotelephony Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 January 2022
Resolved
46 CFR 180.70(b)(1)
Each ring life buoy on a vessel must: (1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. The 02 aft ring life buoys (port and starboard) are not in compliance with Subchapter Q and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 27 January 2022
Resolution: Vessel replaced 02 life buoys.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 January 2022
Resolved
46 CFR 183.10-10 "OLD T"
...all electrical equipment including....distribution
panels... shall be dripproof protected. Distribution
panel in the engine room did not have a door to protect
the breaker panel from water/moisture.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 27 January 2022
Resolution: Vessel installed new breaker panel door.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 18 January 2022
Resolved
46 CFR 184.402(a)
Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Vsl needs to properly install magnetic compass as per manufacturer's instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 27 January 2022
Resolution: Vessel installed illuminating magnetic compass.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 18 January 2022
Resolved
46 CFR 184.602 (c)
When the propulsion machinery of a vessel cannot be controlled from the operating station, an efficient communications system must be provided between the operating station and the propulsion machinery space. Vsl has 01 radio, which is not conducive for two-way communications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 27 January 2022
Resolution: Vessel provided two-way means from operating station to propulsion machinery space using existing handheld radio to installed VHF.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 February 2021
Resolved
When rigid non-metallic piping exist on systems that penetrate a watertight bulkhead, valves are required adjacent to the bulkhead. PVC piping is installed on two sewage lines inside the lazarette. Either replace PVC with metallic piping or install valves on both sides of the watertight bulkhead. 46 CFR "Old T" 182.40-1(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2021
Resolved 23 February 2021
Resolution: PVC watertight bulkhead penetrations have been replaced with stainless steel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 February 2021
Resolved
Wire penetration through lazarette/engineroom bulkhead is not watertight. Seal with a fire retardant sealant. 46 CFR "Old S" 171.114
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 9 February 2021
Resolution: Correctly sized mechanical seal placed around wire.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 14 January 2021
Resolved
LIFE FLOAT LIGHT: Floating waterlight connected to life float had condensation in the bulb casing. Repair/replace light.
LIFE FLOATS: Life floats stacked in tier were not kept apart by a spacer. Place spacer between tiered life floats.-46 CFR 180.175(f)(4)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 3 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 January 2021
Resolved
MAGNETIC COMPASS: No illuminated magnetic compass at operating station. Install illuminated magnetic compass at operating station. -46 CFR 184.402
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 3 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 January 2021
Resolved
GENERATOR AMMETER: Ammeter on generator panel not functioning. Repair ammeter to measure voltage and current of generator.-46 CFR 183.10-5(g)
(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 3 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2021
Resolved
ELECTRICAL OUTLETS: A majority of electrical outlets tested on board had bad grounds. Investigate and repair/replace.-46 CFR 183.10-20(o)
(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 3 February 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 January 2021
Resolved
HATCH COVER: Gasket on forward weather-tight hatch located in main deck accommodation is waisted. Replace/repair gasket.-46 CFR 171.124(a)(2)
(OLD S)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 3 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2020
Resolved
Removed 47 adult pfd and 10 child pfd from service. 6 adult and 6 child pfd brought on from shoreside. Passenger count limited to 93 persons and 10 children. 46 cfr 180.71
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 20 January 2020
Resolution: Email sent to [name withheld], 70 adult and 10 child PFDs were purchased
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 January 2020
Resolved
exhaust is not insulated to the point of water injection. insulate exhaust to water injection point. 46 cfr 182.20-15
Action required: 10 - Deficiency Rectified
Resolved 8 January 2020
Resolution: corrected on the spot
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 8 January 2020
Resolved
Vessel required a reserve power supply for radiotelephone or one VHF handheld in lieu of power supply. 47 CFR 80.917
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 20 January 2020
Resolution: an email was sent to [name withheld], 2 handheld VHFs were purchased
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 January 2020
Resolved
Found 01 expired water light battery on life float. Battery replaced on the spot 46 cfr 180.70(d)
Action required: 10 - Deficiency Rectified
Resolved 8 January 2020
Resolution: corrected on the spot
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 January 2020
Resolved
perform satisfactory drills in presence of marine inspector 46 CFR 170
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 14 January 2021
Resolution: Completed at 2021 Annual.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 January 2019
Resolved
Four openings in watertight coamings along house and below aft door. Provide means to make watertight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 January 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 January 2019
Resolved
Tighten dogs on watertight door. Provide proof of a watertight seal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 January 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 January 2019
Resolved
Paper charts were last updated in 2015
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2019
Resolution: 4th annual was completed.
Fire Fighting › Fire Main › Valves
Issued 17 January 2018
Resolved
MAB01: All valves on fire main shall be IAW good marine practice and suitable for intended purpose. Repair/ replace starboard side firehose valve.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 17 January 2018
Resolution: Provided same-day picture of rectification.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 17 January 2018
Resolved
MAB02: Watertight door between #2 void compartment and space aft must have indicating light at operating statino.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 6 February 2018
Resolution: Recieved proof of functioning watertight door indicator.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 17 January 2018
Resolved
MAB03: Watertight bulkhead penetrations must have means to be watertight. Plug holes in #2 void compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 17 January 2018
Resolution: Received same-day rectification pictures.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 19 January 2017
Resolved
EKO01: Post drug and alcohol number in common space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 February 2017
Resolved 31 January 2017
Resolution: Verified by [name withheld].
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 January 2017
Resolved
EKO02: Support hydraulic lines in forepeak.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 February 2017
Resolved 31 January 2017
Resolution: Verified by [name withheld].
Engineering › Generator (propulsion-electric) › Battery
Issued 19 January 2017
Resolved
EKO03: Replace chafed/ exposed wires on starboard generator starting batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2017
Resolved 31 January 2017
Resolution: Verified by [name withheld].
Lifesaving › Visual Distress Signals (General) › Approval
Issued 19 January 2017
Resolved
EKO04: Log monthly testing of EPIRB.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 January 2017
Resolved 19 January 2017
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 21 January 2016
Resolved
Took 36 adult and five children lifejackets out of service. Vessel must replace these jackets to 134 adult and 14 child prior to 31 May 2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 11 February 2016
Resolution: Vessel operator purchased 34 adult and five children life jackets.
Engineering › Bilge Water Management System › Piping
Issued 21 January 2016
Resolved
Replace all non-metallic material, including flexible piping in bilge system piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2016
Resolved 11 February 2016
Resolution: Vessel owner replaced all non-metallic piping in bilge system.