DAUNTLESS is a 1974 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1984, most recently in January 2026, along with 111 deficiencies.

Records from 1984 to 2026. Most recent: inspection, 29 January 2026.

Built
1974
Last inspected
29 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAK5772
Flag
UNITED STATES
367026450
Maury page id
psix-48241

Inspections, by type

…with no type recorded3
Years with a record 42 calendar years (1984–2026)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)73.8 ft × 22.3 ft × 7.3 ft
Registered tonnagegross 67 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT · PATTERSON, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 November 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Gross Ton
46 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAK5772MMSI 367026450 · active · compulsorily equipped · granted 8 December 2025, expires 18 April 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 75

29 January 2026 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8299688
15 January 2025 Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8049152
8 January 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8057211
18 January 2024 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7851590
14 February 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7636014
25 January 2023 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7626977
18 January 2022 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7380665
3 February 2021 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7135331
14 January 2021 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7124670
8 January 2020 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6884594
25 January 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6615140
14 January 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6609107
17 January 2018 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6330067
19 January 2017 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6073234
19 January 2016 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5799858
22 November 2015 Type not recorded
No type recorded · Station Manasquan Inlet · USCG East District (CGD-E) · Activity 5768670
17 March 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4813962
17 February 2012 Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4246326
23 February 2011 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3951115
8 February 2011 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3941303
4 February 2010 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3674793
6 March 2009 Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3427920
20 February 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3150329
6 February 2007 Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2866979
22 February 2006 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2589629
8 March 2005 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2307918
24 February 2005 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2295335
19 February 2004 Annual Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2008722
14 March 2003 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1756795
27 January 2003 Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1734993
9 May 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1616088
2 April 2002 Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1599883
7 February 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1485588
27 March 2001 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1062263
27 February 2001 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1059666
20 March 2000 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 816666
23 February 2000 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 817454
23 February 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1131426
7 May 1998 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1125323
31 March 1998 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 789001
3 March 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1119819
24 February 1997 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1098542
19 March 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1083460
27 February 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 886369
27 February 1996 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1088526
7 March 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 860019
15 March 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165750
8 March 1994 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855379
8 March 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 840569
27 March 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1257629
12 March 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1262790
9 March 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 951769
16 September 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 935156
10 April 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1228978
2 October 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1241818
18 September 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1215081
28 August 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222525
10 July 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244122
15 March 1990 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 922628
8 March 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 917051
26 October 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1331799
2 October 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030958
17 January 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199226
30 November 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1207224
17 October 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199546
1 December 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001094
23 November 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1028614
18 March 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1015643
12 January 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1314654
1 December 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332759
10 June 1986 Persons In Addition to Crew
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301479
2 January 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304149
16 December 1985 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 994783
13 November 1985 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1292508
11 December 1984 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1284772

Deficiency record · 111

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2026 Resolved
Exhaust piping shall be gas tight throughout its length and shall be properly supported by non-combustible hangers or blocks. MI observed leak in aluminum piping allowing cooling water to leak into steering compartment. 46 CFR 182.15-20(a) OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 5 February 2026
Resolution: Vessel replaced section of exhaust pipe.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 January 2026 Resolved
Primary consideration shall be given to the provision of a seaworthy hull, protection against fire, means of escape, guards and rails in hazardous places, etc. MI observed a pit just under 1/4" on port side of keelson just aft side of class-1 water tight door. Clean pit and cover with corrosion arresting coating. 46 CFR 177.01-5 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 17 February 2026
Resolution: Owner coated pit with Pro Lite body filler to slow corrosion.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2026 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Starboard side M/E and G/E are missing covers for engine driven belts. 46 CFR 177.35-15 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 5 February 2026
Resolution: Suitable guards were placed over rotating machinery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2026 Resolved
That part of the exhaust system between the point of cooling water injection and the engine manifold shall be water-jacketed or effectively insulated. Both of the vessel's G/E exhaust pipes are missing insulation between the turbo and cooling water injector. 46 CFR 182.15-15(b)(3) OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 5 February 2026
Resolution: Uncovered portion of exhaust was wrapped in insulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2026 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screen or flame arresters. Fuel tank vent is missing flame screen. 46 CFR 182.20-35(d) OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 5 February 2026
Resolution: Owner placed flame screen over vent.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 January 2026 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Labeling for child life jackets are not appropriately marked. 46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2026
Resolved 5 February 2026
Resolution: Child life jackets were properly stenciled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 January 2025 Resolved
Fire hoses must be lined commercial fire hose that conforms to UL std. 19 or Federal Specification ZZ-H-451E. The port side fire hose had several leaks. Replace fire hose. 46 CFR 181.15-10(d)(1) Old T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 4 February 2025
Resolution: Type approved fire hose attached to port side fire station.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 January 2025 Resolved
A length of fire hose shall be attached to each fire hydrant at all times. Vessel had washdown hoses attached to fire hydrants and not correct fire hoses. Attach correct fire hoses to hydrants. 46 CFR 181.1510(g) Old T
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 4 February 2025
Resolution: Attached fire hose to fire station.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 January 2025 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The vessel master could not provide a medical certificate from the Coast Guard. Provide a valid medical certificate to the cognizant OCMI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2025
Resolved 1 March 2025
Resolution: Confirmed master's license issued as valid.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 January 2025 Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: “EMERGENCY EXIT KEEP CLEAR”. None of the emergency escape hatches were marked. Mark all emergency escape hatches.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 4 February 2025
Resolution: Emergency exits marked.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 January 2025 Resolved
Watertight doors shall be marked on both sides in 1-inch letters: WATERTIGHT DOOR- CLOSE IN EMERGENCY”. Watertight door was not marked. Mark watertight door as required. 46 CFR 185.30-25(a) Old T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 4 February 2025
Resolution: Watertight door properly marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2025 Resolved
For each watertight door which is in a required subdivision bulkhead, an indicator light must be installed in the pilothouse and at each other vessel operating station from which the door is not visible. The indicator must show whether the door is open or closed. The indicator light was inoperable. Repair light to indicator to indicate whether the door is open or closed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 January 2025
Resolved 28 January 2025
Resolution: Indicator light repaired and operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 January 2025 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. The markings for the number of passengers allowed on the upper deck was no longer visible. Replace required markings for maximum number of passengers allowed on the upper deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 28 January 2025
Resolution: Upper deck passenger count marked at top of ladderway, visible to all passengers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 January 2025 Resolved
All electrical equipment, including distribution panels, shall be so constructed or protected and cannot be inadvertently touched nearer than a safe distance by any person. Blank covers on the forward engine room distribution panel were missing. Place blanks over all exposed overcurrent device locations on distribution panel. 46 CFR 183.10-10(a) Old T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 28 January 2025
Resolution: Blank covers installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 January 2025 Resolved
Any panel in excess of 24 volts shall be fitted with a permanent sign warning personnel of this condition and identifying the circuits to be disconnected to remove all potentials in excess of 24 volts. All circuits on the distribution panel located on the main deck engine room passage were not marked to identify the loads they serve. 46 CFR 183.10-10(c) Old T
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 28 January 2025
Resolution: Panel properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 January 2025 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Placards for donning instructions were not available on the upper deck for passengers to observe, and one placard on the main deck pertained only to kapok type PFD’s. Remove the kapok specific placard, and place a placard for donning instructions on the upper deck where passengers can observe it.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 28 January 2025
Resolution: O/O posted a donning placard on upper deck.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 January 2025 Resolved
Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. Reflective tape on life floats were worn. Replace with new retroreflective material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 28 January 2025
Resolution: o/o replaced retro tape on all BA's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 January 2025 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. The lanyard on the ring life buoy was found short of 3 feet and attached to the hand grab. Replace lanyard with line between 3 and 6 feet long when attached around the body of the life buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 28 January 2025
Resolution: Ring life buoy light lanyard replaced at proper length and attached around body of ring buoy.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 January 2025 Resolved
An inspection is required before the issuance of a Certificate of Inspection. The vessels COI is expired. Receive a valid COI prior to operation and carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 January 2025
Resolution: Issued COI after sucessful COI inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2025 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 22 adult PFD's were found unservicable and destroyed in the presence of the marine inspector. Replace PFD's to satisfy the requirement for the total number of passengers allowed by the COI.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 January 2025
Resolution: PFD's onboard presently satisfy the cold water carriage requirements, the unservicable PFD's were identified and destroyed in the presence of the MI.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 January 2024 Resolved
VESSELS MUST BE EQUIPPED WITH A MASTER KEY CONTROL SYSTEM FOR PHYSICAL, MANUAL, OR ELECTRONIC KEYS OR ACCESS SYSTEMS, WHICH PROVIDES CONTROLLED ACCESS TO ALL COPIES OF THE VESSEL'S MASTER KEY. FOUND NO RECORD/LOG BOOK FOR MASTER KEY. VESSEL HAS 02 DOORS THAT REQUIRE LOCK & KEY. O/O CREATED A LOG BOOK TO TRACK MASTER KEY ACCESS & IDENTIFY CREWMEMBERS IN THE MASTER KEY CONTROL SYSTEM. 01 KEY GOES TO THE DECKHAND & 01 KEY GOES TO THE MASTER.
Action required: 10 - Deficiency Rectified
Due 18 January 2024
Resolved 18 January 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 January 2024 Resolved
THE MINIMUM CAPACITY OF THE POWER FIRE PUMP SHALL BE 50 GALLONS PER MINUTE AT A PRESSURE OF NOT LESS THAN 60 LBS PER SQUARE IN AT THE PUMP OUTLET. THE PUMP OUTLET SHALL BE FITTED WITH A PRESSURE GUAGE. MI'S FOUND FIRE PUMP NOT FITTED WITH A PRESSURE GAUGE. INSTALL PRESSURE GUAGE AT THE PUMP OUTLET.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2024
Resolved 1 February 2024
Resolution: O/O provided pictures of installed pressure gauge at the pump outlet.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 18 January 2024 Resolved
ALL VESSELS EXCEPT NON-SELF-PROPELLED VESSELS SHALL BE PROVIDED WITH SUITABLE STERRING APPARATUS. DISCOVERED LEAKING SEAL ON STEERING RAM DURING CHECKS. REPLACE/REPAIR SEAL ON STEERING RAM.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2024
Resolved 1 February 2024
Resolution: O/O Provided pictures of newly installed steering ram system.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 January 2024 Resolved
EACH VESSEL THAT OPERATES ON THE HIGH SEAS, OR BEYOND THREE MILES FROM THE COASTLINE MUST HAVE ON BOARD A FCC TYPE ACCEPTED CATEGORY 1 EPIRB. FOUND EPIRB HYDROSTATIC RELEASE MISSING EXPIRATION DATE. PROVIDE DOCUMENTATION ON HYDROSTATIC RELEASE INSTALLATION DATE OR REPLACE HYDROSTATIC RELEASE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2024
Resolved 1 February 2024
Resolution: O/O Purchased new hydrostatic release for EPIRB & provided pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 January 2024 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Found ring life buoy missing float light. Add float light to ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2024
Resolved 1 February 2024
Resolution: O/O Provided picture of float light attached to life ring buoy.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 January 2023 Resolved
Pitting was identified along 3 frames (along chine and one longitudinal frame above chine) on port side shell boiler room and cracked weld in forpeak starboard side. Provide repair proposal to crop and renew side shell plating that was identified to exceed 25% degradation, provide original scantlings and repair cracked weld on longitudinal frame.
Action required: 705 - Other - as specified
Due 25 March 2023
Resolved 6 February 2023
Resolution: Vessel owner cropped and reneewed pitting area identified. (See pictures)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 January 2023 Resolved
The bilge pipe piercing the collision bulkhead shall be fitted with a screw down valve on the forward side of the collision bulkhead and operable from the weather deck. Valve head was broken, replace broken valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2023
Resolved 6 February 2023
Resolution: Vessel owner replaced valve in forpeak.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 18 January 2022 Resolved
47 CFR 80.1005 Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Vsl's Federal Communications Commission Bridge-to-Bridge Certificate is expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 27 January 2022
Resolution: Vessel provided Bridge-to-Bridge Certificate.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 18 January 2022 Resolved
47 CFR 80.903 Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vsl does not have a Federal Communications Commission Safety Safety Radiotelephony Certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 27 January 2022
Resolution: Vessel provided Safety Radiotelephony Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 January 2022 Resolved
46 CFR 180.70(b)(1) Each ring life buoy on a vessel must: (1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. The 02 aft ring life buoys (port and starboard) are not in compliance with Subchapter Q and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 27 January 2022
Resolution: Vessel replaced 02 life buoys.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 January 2022 Resolved
46 CFR 183.10-10 "OLD T" ...all electrical equipment including....distribution panels... shall be dripproof protected. Distribution panel in the engine room did not have a door to protect the breaker panel from water/moisture.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 27 January 2022
Resolution: Vessel installed new breaker panel door.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 18 January 2022 Resolved
46 CFR 184.402(a) Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Vsl needs to properly install magnetic compass as per manufacturer's instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 27 January 2022
Resolution: Vessel installed illuminating magnetic compass.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 18 January 2022 Resolved
46 CFR 184.602 (c) When the propulsion machinery of a vessel cannot be controlled from the operating station, an efficient communications system must be provided between the operating station and the propulsion machinery space. Vsl has 01 radio, which is not conducive for two-way communications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 27 January 2022
Resolution: Vessel provided two-way means from operating station to propulsion machinery space using existing handheld radio to installed VHF.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 February 2021 Resolved
When rigid non-metallic piping exist on systems that penetrate a watertight bulkhead, valves are required adjacent to the bulkhead. PVC piping is installed on two sewage lines inside the lazarette. Either replace PVC with metallic piping or install valves on both sides of the watertight bulkhead. 46 CFR "Old T" 182.40-1(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2021
Resolved 23 February 2021
Resolution: PVC watertight bulkhead penetrations have been replaced with stainless steel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 February 2021 Resolved
Wire penetration through lazarette/engineroom bulkhead is not watertight. Seal with a fire retardant sealant. 46 CFR "Old S" 171.114
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2021
Resolved 9 February 2021
Resolution: Correctly sized mechanical seal placed around wire.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 14 January 2021 Resolved
LIFE FLOAT LIGHT: Floating waterlight connected to life float had condensation in the bulb casing. Repair/replace light. LIFE FLOATS: Life floats stacked in tier were not kept apart by a spacer. Place spacer between tiered life floats.-46 CFR 180.175(f)(4)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 3 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 January 2021 Resolved
MAGNETIC COMPASS: No illuminated magnetic compass at operating station. Install illuminated magnetic compass at operating station. -46 CFR 184.402
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 3 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 January 2021 Resolved
GENERATOR AMMETER: Ammeter on generator panel not functioning. Repair ammeter to measure voltage and current of generator.-46 CFR 183.10-5(g) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 3 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2021 Resolved
ELECTRICAL OUTLETS: A majority of electrical outlets tested on board had bad grounds. Investigate and repair/replace.-46 CFR 183.10-20(o) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 3 February 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 January 2021 Resolved
HATCH COVER: Gasket on forward weather-tight hatch located in main deck accommodation is waisted. Replace/repair gasket.-46 CFR 171.124(a)(2) (OLD S)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 3 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2020 Resolved
Removed 47 adult pfd and 10 child pfd from service. 6 adult and 6 child pfd brought on from shoreside. Passenger count limited to 93 persons and 10 children. 46 cfr 180.71
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 20 January 2020
Resolution: Email sent to [name withheld], 70 adult and 10 child PFDs were purchased
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 January 2020 Resolved
exhaust is not insulated to the point of water injection. insulate exhaust to water injection point. 46 cfr 182.20-15
Action required: 10 - Deficiency Rectified
Resolved 8 January 2020
Resolution: corrected on the spot
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 8 January 2020 Resolved
Vessel required a reserve power supply for radiotelephone or one VHF handheld in lieu of power supply. 47 CFR 80.917
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 20 January 2020
Resolution: an email was sent to [name withheld], 2 handheld VHFs were purchased
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 January 2020 Resolved
Found 01 expired water light battery on life float. Battery replaced on the spot 46 cfr 180.70(d)
Action required: 10 - Deficiency Rectified
Resolved 8 January 2020
Resolution: corrected on the spot
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 8 January 2020 Resolved
perform satisfactory drills in presence of marine inspector 46 CFR 170
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 14 January 2021
Resolution: Completed at 2021 Annual.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 January 2019 Resolved
Four openings in watertight coamings along house and below aft door. Provide means to make watertight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 January 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 January 2019 Resolved
Tighten dogs on watertight door. Provide proof of a watertight seal.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 January 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 January 2019 Resolved
Paper charts were last updated in 2015
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2019
Resolution: 4th annual was completed.
Fire Fighting › Fire Main › Valves
Issued 17 January 2018 Resolved
MAB01: All valves on fire main shall be IAW good marine practice and suitable for intended purpose. Repair/ replace starboard side firehose valve.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 17 January 2018
Resolution: Provided same-day picture of rectification.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 17 January 2018 Resolved
MAB02: Watertight door between #2 void compartment and space aft must have indicating light at operating statino.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 6 February 2018
Resolution: Recieved proof of functioning watertight door indicator.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 17 January 2018 Resolved
MAB03: Watertight bulkhead penetrations must have means to be watertight. Plug holes in #2 void compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 17 January 2018
Resolution: Received same-day rectification pictures.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 19 January 2017 Resolved
EKO01: Post drug and alcohol number in common space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 February 2017
Resolved 31 January 2017
Resolution: Verified by [name withheld].
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 January 2017 Resolved
EKO02: Support hydraulic lines in forepeak.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 February 2017
Resolved 31 January 2017
Resolution: Verified by [name withheld].
Engineering › Generator (propulsion-electric) › Battery
Issued 19 January 2017 Resolved
EKO03: Replace chafed/ exposed wires on starboard generator starting batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2017
Resolved 31 January 2017
Resolution: Verified by [name withheld].
Lifesaving › Visual Distress Signals (General) › Approval
Issued 19 January 2017 Resolved
EKO04: Log monthly testing of EPIRB.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 January 2017
Resolved 19 January 2017
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 21 January 2016 Resolved
Took 36 adult and five children lifejackets out of service. Vessel must replace these jackets to 134 adult and 14 child prior to 31 May 2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 11 February 2016
Resolution: Vessel operator purchased 34 adult and five children life jackets.
Engineering › Bilge Water Management System › Piping
Issued 21 January 2016 Resolved
Replace all non-metallic material, including flexible piping in bilge system piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 February 2016
Resolved 11 February 2016
Resolution: Vessel owner replaced all non-metallic piping in bilge system.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 February 2011 Resolved
Five cracks detailed in activity 3941303.
Action required: 705 - Other - as specified
Resolved 24 February 2011
Resolution: Cracks repaired with welding.
Construction/Loadline › Structures › Deck Plating
Issued 2 April 2009 Resolved
A hole was found near the Port stern section on the main deck of the boat. Pitting was also discovered near the hole and on Starboard stern section of the main deck. Cracks were found on the Marine Sanitation Device Discharge Pipe. Boat owner is required to submit repair proposal for deficiencies and correct them to the satisfaction of marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2009
Resolution: Owner submitted repair proposal. Marine Inspector inspected repair and found it satisfactory.
Operations/Management › Drug and Alcohol Testing
Issued 19 February 2004 Resolved
Provide current Drug testing participation letter. LEGACY COMPONENT DESC: Proof of Enrollment
Due 19 March 2004
Resolved 19 February 2004
Resolution: Rcvd fax confirmation of Drug testing particapation.
Electrical › Lighting (service)
Issued 19 February 2004 Resolved
Engine room light missing protective cover. LEGACY COMPONENT DESC: Lighting Fixture
Due 19 March 2004
Resolved 6 April 2004
Electrical › Electrical Distribution System (service)
Issued 19 February 2004 Resolved
Missing non-conductive deck covering below all breaker panels. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Due 19 March 2004
Resolved 6 April 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 19 February 2004 Resolved
Breaker panel in Engine room access trunk missing door and several protective blanks missing inside panel.
Condition: Improper/Lack of Maintenance
Due 19 March 2004
Resolved 6 April 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 January 2003 Resolved
B-I portable fire extinguisher not serviced annually.
Condition: Improper/Lack of Maintenance
Due 27 January 2003
Resolved 27 January 2003
Resolution: B-I extinguisher properly serviced.
Lifesaving › Lifejacket/PFD (General)
Issued 24 January 2003 Resolved
Waterlight battery not working properly.
Condition: Improper/Lack of Maintenance
Due 27 January 2003
Resolved 27 January 2003
Resolution: Battery replaced in waterlight.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 January 2003 Resolved
Missing blank breaker in panel.
Condition: Improper/Lack of Maintenance
Due 27 January 2003
Resolved 27 January 2003
Resolution: Placed proper empty breaker in open distribution panel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 January 2003 Resolved
COI and Stability letter not posted.
Condition: Placed in Improper Service
Due 27 January 2003
Resolved 27 January 2003
Resolution: Posted letters properly.
Construction/Loadline › Hull
Issued 2 April 2002 Resolved
Vessel not to operate with passengers on upper deck until weight and stability issues in regards to repowering are cleared with MSO Philadelphia.
Due 15 May 2002
Resolved 9 May 2002
Resolution: A review of the results for re-powering by Derecktor Shipyards by the CID in PHIMS was as follows, neither testing nor recalculation of loads/stability criteria requires changes to be at this time. Letter to be retained in vessel folder.
Operations/Management › Drug and Alcohol Testing
Issued 7 February 2002 Resolved
Provide current copy of crew registered with Meridian Health Systems. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 February 2002
Resolved 14 February 2002
Communications › Radio Communications
Issued 7 February 2002 Resolved
Provide corrected copy of EPIRB Registration displaying vessel name and registration. LEGACY COMPONENT DESC: EPIRB
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 February 2002
Resolved 14 February 2002
Navigation › Piloting/Steering
Issued 7 February 2002 Resolved
Provide current copy of U. S. Coast Pilot and Light List. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 14 February 2002
Resolved 21 February 2002
Lifesaving › Lifebuoys
Issued 7 February 2002 Resolved
Provide clip for light attached to ring buoy on top deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2002
Resolved 14 February 2002
Lifesaving › Lifejacket/PFD (Type II)
Issued 7 February 2002 Resolved
Provide (2) Adult life jackets. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 February 2002
Resolved 14 February 2002
Engineering › Steering Gear System
Issued 7 February 2002 Resolved
Re-weld starboard rudder post stop. LEGACY COMPONENT DESC: Linkage
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2002
Resolved 21 February 2002
Engineering › Steering Gear System
Issued 7 February 2002 Resolved
Re-pack starboard rudder post due to excessive leakage during underway steering test. LEGACY COMPONENT DESC: Rudder Stock
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2002
Resolved 21 February 2002
Operations/Management › Navigation Safety
Issued 7 February 2002 Resolved
Make vessel available for underway test in presence of USCG Marine Inspector (For steering repairs). LEGACY COMPONENT DESC: Navigation Underway, General
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2002
Resolved 21 February 2002
Lifesaving
Issued 27 February 2001 Resolved
Stencil all 3 lifefloats with passenger count and vessel name.
Condition: Unknown
Due 27 March 2001
Resolved 19 March 2001
Accommodation/Occupational Safety
Issued 27 February 2001 Resolved
Label upper deck for maximum number of passengers allowed.
Condition: Unknown
Due 27 March 2001
Resolved 19 March 2001
Electrical
Issued 27 February 2001 Resolved
Replace wire on port light and outlet.
Condition: Unknown
Due 27 March 2001
Resolved 19 March 2001
Lifesaving
Issued 27 February 2001 Resolved
Provide vessel name and retro-reflective tape on 7 adult and 2 children lifejackets.
Condition: Unknown
Due 27 March 2001
Resolved 19 March 2001
Fire Fighting
Issued 27 February 2001 Resolved
Provide proof of inspection of portable fire fighting extinguishers.
Condition: Unknown
Due 27 March 2001
Resolved 19 March 2001
Navigation
Issued 27 February 2001 Resolved
Update navigation charts and publications.
Condition: Unknown
Due 27 March 2001
Resolved 19 March 2001
Lifesaving
Issued 23 February 2000 Resolved
Renew expired medication in First Aid kit.
Condition: Unknown
Due 31 March 2000
Resolved 23 March 2000
Lifesaving
Issued 23 February 2000 Resolved
Provide retro-reflective tape on topside ring buoy.
Condition: Unknown
Due 31 March 2000
Resolved 8 April 2002
Resolution: Retoreflective tape applied as required.
Lifesaving
Issued 23 February 2000 Resolved
Label location of child size PFDs
Condition: Unknown
Due 31 March 2000
Resolved 9 May 2002
Resolution: visually inspected, all sat
Fire Fighting
Issued 23 February 2000 Resolved
Provide one additional BII portable fire extinguisher.
Condition: Unknown
Due 31 March 2000
Resolved 23 March 2000
Construction/Loadline
Issued 12 March 1992 Resolved
PROPERLY VEE OUT AND REWELD CRACK IN FOREPEAK, FRAME #1 STBD NEAR OVERHEAD,2 CRACKS IN WATERTIGHT DOOR FRAME AND 1 IN WATERTIGHT DOOR, 2ND COMPARTMENTFROM FWD.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Construction/Loadline
Issued 10 April 1991 Resolved
PROPERLY VEE OUT & REWELD CRACKS IN FORWARD VOID COMPARTMENT AS FOLLOWS: 1EACH PORT & STBD LONGITUDINALS IN WAY OF COLLISION BLKHD; 1 IN WATERTIGHT DOOR FRAME (WELD BOTH SIDES). VSL SHALL NOT OPERATE WITH PASSENGERS UNTIL THIS REQUIREMENT IS MET TO THE SATISFACTION OF THE ATTENDING USCG INSPECTOR
Condition: Unknown
Due 10 April 1991
Resolved 10 April 1991
Electrical
Issued 18 September 1990 Resolved
PROPERLY MOUNT CIRCUIT BREAKER COVER LEADING TO ENGINE ROOM.
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990
Lifesaving
Issued 18 September 1990 Resolved
REPLACE EPIRB BATTERY (OUTDATED).
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990
Navigation
Issued 18 September 1990 Resolved
REPLACE NAVIGATION LIGHTS WITH APPROVED TYPES.
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990
Navigation
Issued 18 September 1990 Resolved
PROVIDE CHARTS AND NAUTICAL PUBLICATIONS AS PER 46 CFR 185.20-35.
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990
Fire Fighting
Issued 18 September 1990 Resolved
PROVIDE GAUGE FOR MEASURING PRESSURE AT THE FIRE PUMP.
Condition: Unknown
Due 18 September 1990
Resolved 18 September 1990
Construction/Loadline
Issued 15 March 1990 Resolved
PROVIDE/REPLACE THE PRESENT DOG-STYLE WATERTIGHT DOOR (LOCATED BETWEEN #2 &#3 COMPARTMENT) WITH A QUICK ACTING WATERTIGHT DOOR AND INDICATOR ON THE BRIDGE SHOWING WHEN IT IS OPEN.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Lifesaving
Issued 2 October 1989 Resolved
PROVIDE 16 PERSONAL FLOATATION DEVICES BY NO LATER THAN 02NOV89. UNTIL THATDATE THE VESSEL WILL BE RESTRICTED TO CARRY ONLY 134 PERSONS TOTAL.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Construction/Loadline
Issued 30 November 1988 Resolved
GAUGE OUT AND RE-WELD BROKEN WELD BETWEEN STANCHION AND UNDERDECK BEAM IN THE FORWARD COMPARTMENT PORT SIDE STANCHION.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Accommodation/Occupational Safety
Issued 23 November 1987 Resolved
SUPPLY RUNNING WATER TO TWO (2) WASH BASINS IN MEN AND WOMEN HEAD, PRESENTLY NOT SUPPLIED.
Condition: Unknown
Due 23 November 1987
Resolved 23 November 1987
Accommodation/Occupational Safety
Issued 23 November 1987 Resolved
PROVIDE INSULATION ON HOT AIR HEATER EXHAUST PIPE, PRESENTLY MISSING.
Condition: Unknown
Due 23 November 1987
Resolved 23 November 1987
Lifesaving
Issued 23 November 1987 Resolved
PROVIDE LINE TO ATTACH FLOATING WATER LIGHT TO RING BUOY WHERE MISSING.
Condition: Unknown
Due 23 November 1987
Resolved 23 November 1987
Construction/Loadline
Issued 23 November 1987 Resolved
REPAIR SCUTTLE LEADING FROM ENGINE ROOM, PRESENTLY INOPERABLE.
Condition: Unknown
Due 23 November 1987
Resolved 23 November 1987
Fire Fighting
Issued 23 November 1987 Resolved
MARK OR STENCIL LOCATION OF ONE 15 LBS. CO2 FIRE EXTINGUISHER, STORED IN UNMARKED COMPARTMENT IN ACCOMODATION SPACE.
Condition: Unknown
Due 23 November 1987
Resolved 23 November 1987
Engineering
Issued 23 November 1987 Resolved
PROVIDE OPERATIONAL TEST OF COLLISION COMPARTMENT BILGE SYSTEM VALVE, PRESENTLY INOPERATIVE.
Condition: Unknown
Due 23 November 1987
Resolved 23 November 1987
Construction/Loadline
Issued 1 December 1986 Resolved
PLUG/CAP OLD PIPE AT THE BULKHEAD BETWEEN ENGINEROOM AND LAZERRETE.
Condition: Unknown
Due 1 December 1986
Resolved 1 December 1986
Engineering
Issued 1 December 1986 Resolved
PROVE PROPER OPERATION OF AIR RECEIVER PRESSURE RELIEF VALVE.
Condition: Unknown
Due 1 December 1986
Resolved 1 December 1986
Accommodation/Occupational Safety
Issued 1 December 1986 Resolved
HOOK-UP RUNNING WATER AND DRAINS IN BOTH HEADS.
Condition: Unknown
Due 1 December 1986
Resolved 1 December 1986
Engineering
Issued 1 December 1986 Resolved
PROVE PROPER OPERATIONAL TEST OF ALL SAFETIES ON OIL FIRED PACKAGE HEATER FOR ACCOMMODATION SPACE.
Condition: Unknown
Due 1 December 1986
Resolved 1 December 1986
Accommodation/Occupational Safety
Issued 16 December 1985 Resolved
PROVIDE WASH BASIN'S IN MEN AND WOMEN HEADS. WHERE MISSING.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Lifesaving
Issued 16 December 1985 Resolved
PROVIDE SEPARATE STOWAGE FOR 11 CHILD PFD'S PRESENTLY STOWED WITH ADULTS.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Lifesaving
Issued 16 December 1985 Resolved
PROVIDE OPERATING TEST OF 1 WATERLIGHT PRESENTLY NOT WORKING.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Construction/Loadline
Issued 16 December 1985 Resolved
PROVIDE CAPTIVE CHAINS ON 2 WATER TIGHT HATCHES ON MAIN DECK, WEHRE MISSING
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Accommodation/Occupational Safety
Issued 11 December 1984 Resolved
MAKE REPAIRS TO OR RENEW EXISTING MARINE SANITATION DEVICE HOLDING TANK. REPAIRS TO BE DONE IAW CG REQUIREMENTS FOR MATERIALS AND CONSTRUCTION.
Condition: Unknown
Due 11 December 1984
Resolved 11 December 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.