Records from 2016 to 2025. Most recent: inspection, 18 June 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)51.0 ft × 15.8 ft × 6.1 ft
Registered tonnagegross 40 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD INC · WESTPORT, WA, UNITED STATES · built 1975
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWESTPORT, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationCase Pending · issued 19 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Regulatory (Subpart C or D), Gross Ton
27 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
18 June 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8166673
6 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8089748
2 May 2024
Type not recorded
No type recorded · Station Neah Bay · USCG Northwest District (CGD-NW) · Activity 7919380
11 April 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7895310
20 February 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7867916
22 March 2023
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7656517
6 June 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7473967
14 March 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7416659
6 April 2021
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7170120
22 February 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7144413
16 June 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6978781
20 February 2020
Type not recorded
No type recorded · USCGC TERRAPIN (WPB 87366) · USCG Northwest District (CGD-NW) · Activity 6919733
24 July 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6760656
24 July 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6762254
18 December 2018
Damage Survey · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6606410
17 July 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6482769
17 April 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6126081
4 April 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6118547
28 April 2016
COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5863715
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 11 April 2024
Resolved
Original Certificate of Documentation not on board. Provide original COD aboard the vessel.
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 22 April 2024
Resolution: Original certificate aboard vessel.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 11 April 2024
Resolved
EPIRB hydrostatic release unit is beyond its expiration date. Provide a valid unit.
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 12 April 2024
Resolution: New unit installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 11 April 2024
Resolved
Arrangement for recovering a helpless person from the water does not provide the mechanical advantage recommended by the manufacturer (LifeSling). Provide tackle in IAW manufacturer's recommendations.
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 30 April 2024
Resolution: Proper tackle on board.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 11 April 2024
Resolved
Engine room ventilation is missing closer required for spaces with fixed extinguishing systems installed. Provide closers.
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 30 April 2024
Resolution: Closers provided.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 22 March 2023
Resolved
Original current COD was not onboard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2023
Resolved 31 March 2023
Resolution: New COD on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 March 2023
Resolved
FCC Safety Radiotelephony Certificate not on board.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2023
Resolved 25 July 2023
Resolution: Received third party report of compliance.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 March 2023
Resolved
Stern light and anchor light not functioning
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 24 March 2023
Resolution: Item corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 April 2021
Resolved
01 portable fire extinguisher found with gauge outside of optimal range. Replace or service portable fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 14 December 2021
Resolution: Recieved photo of the gauge within optimal range and servicing report from Peninsula Fire from 06May2021.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 April 2021
Resolved
Escape hatch forward of the pilot house not marked on both sides in clearly legible letters at least 2 inches high: "EMERGENCY EXIT, KEEP CLEAR."
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 3 December 2021
Resolution: The word EXIT is clearly legible below the escape hatch.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 6 April 2021
Resolved
Identify watch keeping schedule in writing for vessel carrying overnight passengers to maintain suitable number of watchmen patrol throughout the vessel during the nighttime, wheter or not the vessel is underway, to guard against, and give alarm in case of, a fire, man overboard, or other dangerous situation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 3 December 2021
Resolution: Received photographic evidence of the watchkeeping standards for overnight passengers in writing posted at the healm.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 April 2021
Resolved
MMSI number not programmed into the vessel's DSC Radio. Program DSC radio with vessel's assigned MMSI number from the FCC Station License.47CFR80.103(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 3 December 2021
Resolution: Received photographic evidence of MMSI number shown and programmed into the DSC Radio.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 April 2021
Resolved
DSC equipped radio is not receiving position data from installed navigation equipment. FCC regulations require this connection if navigational equipment is installed. Properly connect DSC radio to installed GPS. 47CFR80.1085(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 3 December 2021
Resolution: Received photographic evidence of coordinates being shown.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 February 2021
Resolved
A vessel that is exposed to salt water more than 3 months in any 12 month period must undergo a drydock and internal structural exam at least once every 2 years. Vessel missed drydock and internal structural exam.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 April 2021
Resolved 6 April 2021
Resolution: Conducted DDX and ISE Exams.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 July 2019
Resolved
To maintain a valid Certificate of Inspection(COI) an annual inspection must be completed 3 months before or after the anniversary date. Vessel's COI anniversary date is 22APR19. Vessel is prohibited from the carriage of more than 6 passengers for hire until the completion of its annual inspection.
46CFR176.502
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2019
Resolved 24 July 2019
Resolution: Vessel has a current COI
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 December 2018
Resolved
Extensive wood rot was observed in the Pilot house superstructure IVO of windows. all wood to be replaced in kind.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 January 2019
Resolved 28 December 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 18 December 2018
Resolved
Extensive wood rot was found around house windows and frames. Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 January 2019
Resolved 28 December 2018
Resolution: All rotted wood was cropped out and replaced in kind.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 April 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 19 July 2017
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Fuel Oil Service System › Piping
Issued 17 April 2017
Resolved
Flexible fuel line does not meet SAE-J-1942 specification.
Action required: 705 - Other - as specified
Due 17 July 2017
Resolved 14 July 2017
Resolution: Fuel hoses have been replaced with approved flexible hoses.
Construction/Loadline › Structures › Superstructure
Issued 4 April 2017
Resolved
Permanently repair port side of house in between windows where caulking is securing laminate to house structure at next drydock period.
Action required: 705 - Other - as specified
Due 4 April 2019
Resolved 16 June 2020
Resolution: Permanent fiberglass repairs to the side of house have been made.
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 4 April 2017
Resolved
Replace port and starboard stern tube water lubricated bearings at next drydock. Approaching wear limitations.
Action required: 705 - Other - as specified
Due 4 April 2019
Resolved 16 June 2020
Resolution: Water lubricated bearings replaced.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 April 2016
Resolved
Provide VHF DSC Radio with MMIS number and GPS interface.
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 31 May 2016