Records from 2005 to 2020. Most recent: inspection, 20 October 2020.
Documentation record
Registered dimensions (L × B × D)42.0 ft × 23.0 ft × 6.6 ft
Registered tonnagegross 22 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNot recorded
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, restricted
DocumentationValid · issued 26 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
20 October 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7080577
28 July 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7018614
26 July 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6750508
31 May 2019
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6698936
5 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6555446
24 July 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6489117
28 April 2017
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6127808
16 March 2017
Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6105843
23 June 2016
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5916859
20 June 2012
Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4349912
2 July 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3525698
20 February 2009
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3414670
24 April 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3183799
28 October 2007
Type not recorded
No type recorded · Station Golden Gate · USCG Southwest District (CGD-SW) · Activity 3088692
10 May 2007
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2938218
2 April 2007
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2900131
15 February 2007
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2872545
21 November 2005
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2538516
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 5 October 2018
No resolution recorded
MEASURE LENGTH IN M NOT FT: Measure length in FT (Vsl dimension Must be measured in meters)
Condition: Invalid
Action required: 705 - Other - as specified
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 April 2017
Resolved
Prove proper operation of port bilge high level alarm. 46 CFR 182.530
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 1 May 2017
Resolution: Bilge alarm satisfactorily tested.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 April 2017
Resolved
Engine shutoff and resets were not operational on either of vessel's two pre manufactured Sea Fire fixed FM 200 fire extinguishing system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 28 April 2017
Resolution: Power to system panel at operating station disconnected during recent drydock. both port and starboard system tested satisfactorily after power reconnected. Corrected on the spot.
Navigation › Piloting/Steering › Marine Charts
Issued 24 April 2008
Resolved
Provide corrected nautical chart for area of operation.
Action required: 705 - Other - as specified
Due 24 April 2008
Resolved 24 April 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 April 2008
Resolved
Renew/replace expired aspirin in first aid kit.
Action required: 705 - Other - as specified
Due 24 April 2008
Resolved 24 April 2008
Fire Fighting › Fire Bucket › Quantity
Issued 24 April 2008
Resolved
Provide one additional fire bucket for a total of three fire buckets.
Action required: 705 - Other - as specified
Due 24 April 2008
Resolved 24 April 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 24 April 2008
Resolved
Post emergency broadcast placard.
Action required: 705 - Other - as specified
Due 24 April 2008
Resolved 24 April 2008
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 24 April 2008
Resolved
Replace battery in buoyant apparatus waterlight.
Action required: 705 - Other - as specified
Due 24 April 2008
Resolved 24 April 2008