A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical
Issued 1 May 1990
Resolved
PROVIDE A COMPATIBLE (SLIDE IN BUS-CLAMPED TYPE) CIRCUIT BREAKER FOR THE CDC-701 MMCC PETRIOBRAS FEEDER CIRCUIT(400AMP A/C) ON THE MAIN DISTRIBUTIONBUS BOARD IN ACCORDANCE WITH 46CFR111.30.3,4,5. CURRENTLY INSTALLED BREAKER IS A FIRE HAZZARD AND PERSONNEL HAZZARD.
Condition: Unknown
Due 1 June 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 1 May 1990
Resolved
COMPLETE PERMANENT REPAIRS IN ACCORDANCE WITH SPECITICATIONS APPROVED BY MANUFAQCTURER 9NATIONAL CRANE) TO THE STARBOARD CRANE BOOM LOWER SECTION. PROVIDE DOCUMENTATION OF SATISFACTORY TESTING IN ACCORDANCE WITH 46CFR91.37-40 TO THE OCMI AT THE ABOVE ADDRESS.
Condition: Unknown
Due 1 June 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 1 May 1990
Resolved
COMPLETE SERVICING OF FOUR (4) FLOAT FREE INFLATABLE LIFERAFTS IN AN APPROVED SERVICING FACILITY WITNESSED BY AN COAST GUARD MARINE INSPECTOR
Condition: Unknown
Due 1 June 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 24 August 1989
Resolved
RECHARGE BREATHING AIR CYLINDERS ( BOTH IN BOAT NO. 1 AND AFT CYLINDER IN BOAT NO. 2) TO 2200 PSIG.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Accommodation/Occupational Safety
Issued 24 August 1989
Resolved
CONDUCT TESTS OF BOTH PVHO'S (PRESSURE VESSELS FOR HUMAN OCCUPANCY) AS REQUIRED BY 46 CFR 197.328 AND 197.462. SUBMIT REQUIRED PLANS PER 46 CFR 197.328 FOR APPROVAL. COMPLETE PRIOR TO USE OR REMOVE SAID VESSELS FROM PENROD 71.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Electrical
Issued 24 August 1989
Resolved
PROVIDE IDENTIFICATION LABELS AND OPERATIONAL MARKINGS FOR ELECTRICAL CONTROLLERS AND BREAKER PANEL BOARDS WHERE MISSING, THROUGHOUT VESSEL.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Lifesaving
Issued 24 August 1989
Resolved
PROVIDE THIRTEEN ADDITIONAL LIFE PRESERVER LIGHTS FOR SPARE PERSONAL FLOATATION DEVICES; REMOVE UNAPPROVED PERSONAL FLOATATION DEVICES FROM VESSEL.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Lifesaving
Issued 24 August 1989
Resolved
PROVIDE THREE ADDITIONAL LIFEBOAT PROVISIONS : ONE FOR PORT BOAT, TWO FOR STARBOARD. PROVIDE FIFTEEN ADDITIONAL CANS (.350 ML) OF DRINKING WATER FOR STARBOARD LIFEBOAT.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Electrical
Issued 24 August 1989
Resolved
CONDUCT OPERATIONAL TEST OF NO.1 DEISEL GENERATOR REVERSE POWER RELAY UPON COMPLETION OF ENGINE REPAIRS/OVERHAUL; MAKE LOG ENTRY DOCUMENTING SATISFACTORY TEST.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Electrical
Issued 24 August 1989
Resolved
PROVIDE A COMPATIBLE (SLIDE IN, BUS-CLAMPED TYPE) CIRCUIT BREAKER FOR THE CDC-701 MCC PETROBRAS FEEDER (400 AMP AC) ON THE MAIN DISTRIBUTION BUS BOARD IN ACCORDANCE WITH 46 CFR 111.30.4,3 AND 5. CURRENTLY INSTALLED BREAKER IS A FIRE HAZARD AND PERSONNEL HAZARD.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Unknown
Issued 24 August 1989
Resolved
CONDUCT OPERATIONAL TEST OF RELIEF VALVES FOR EACH MUD PUMP PRIOR TO PLACING BACK IN SERVICE.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Deck/Cargo
Issued 24 August 1989
Resolved
REPLACE, OR EFFECT PERMANENT REPAIRS IN ACCORDANCE WITH SPECIFICATIONS APPROVED BY MANUFACTURER (NATIONAL) TO STARBOARD CRANE BOOM LOWER SECTION. PROVIDE DOCUMENTATION OF SATISFACTORY TESTING IN ACCORDANCE WITH 46 CFR 91.37-40 TO ABOVE ADDRESS.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Fire Fighting
Issued 24 August 1989
Resolved
PROVIDE ONBOARD 3 SCBA BOTTLES FOR EACH OF THREE FIREMAN'S OUTFITS (PER LIFESAVING PLAN); CURRENT BOTTLES ARE OVERDUE FOR FIVE YEAR HYDROSTATIC TESTING.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Fire Fighting
Issued 24 August 1989
Resolved
PROVIDE ONBOARD AND DEMONSTRATE PROPER OPERATION OF A UL OR FM APPROVED OXYGEN AND EXPLOSIVE METER FOR EACH FIREMEN'S OUTFIT REQUIRED UNDER FIREFIGHTING AND LIFESAVING PLAN (3).
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Accommodation/Occupational Safety
Issued 24 August 1989
Resolved
CONDUCT TESTS OF DIVING BELL AS REQUIRED BY 46 CFR 197.328,197.330 AND 197.462; SUBMIT REQUIRED PLANS PER 46 CFR 197.328 FOR APPROVAL. COMPLETE PRIOR TO USE OR REMOVE SAID VESSEL FROM PENROD 71.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Accommodation/Occupational Safety
Issued 24 August 1989
Resolved
INSTALL A HANDRAIL, AT LEAST THREE FEET HIGH, EXTENDING FROM EACH OF THE TWO AFT HELOPORT STAIRWAY RAILS ALONG HELO DECK PERIMETER ; PAINT DECK TO SHOW SAFE EXIT PATH FOR DISEMBARKING PERSONNEL. REF: NVIC 3-78(3)(D) & 46 CFR 107.275
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Lifesaving
Issued 24 August 1989
Resolved
REATTACH LOOSE SUPPORT PEDISTALS FOR THE ROTTEMER RELEASING GEAR SHAFT IN BOTH THE PORT AND STARBOARD LIFEBOATS.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Lifesaving
Issued 24 August 1989
Resolved
INSTALL FLASHING LIGHTS OR AUDIBLE SIREN CAPABLE OF BEING HEARD ABOVE BACKGROUND NOISE LEVELS IN PRODUCTION AREAS FORWARD AND TO STARBOARD OF DRILL FLOOR. (GAS COMPRESSOR) FOR THE GENERAL ALARM. REF: 46 CFR 113.25-9 OR 10
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Lifesaving
Issued 24 August 1989
Resolved
CONDUCT OPERATIONAL TESTING OF NO. 1 EMD DIESEL GENERATOR OVERSPEED SHUTDOWN, LOW LUBE OIL PRESSURE SHUTDOWN, AND HIGH WATER TEMPERATURE ALARM PRIOR TO PLACING BACK IN SERVICE; PROVIDE LOG ENTRY(COPY) DOCUMENTING THESE TESTS.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Accommodation/Occupational Safety
Issued 24 August 1989
Resolved
RENEW GRAB LINES ON ALL RING LIFE BUOYS; RENEW WITH (FLOATING) BUOYANT TYPE SYNTHETIC MATERIAL,3/8 INCH DIAMETER, WITH MINIMUM BREAKING STRENGTH OF 1,350 POUNDS PER 46 CFR 160.050-3(C).
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Lifesaving
Issued 24 August 1989
Resolved
OPERATE BOTH NO.1 AND NO.2 MOTOR LIFEBOATS IN WATER, EXERCISING WATER SPRAY SYSTEM. PROVIDE A COPY OF A LOG ENTRY DOCUMENTING THIS EVENT FOR EACH BOAT.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Fire Fighting
Issued 24 August 1989
Resolved
MAKE PERMANENT REPAIRS TO BOTH FIRE PUMP'S DISCHARGE PIPING IN WAY OF PRESSURE GUAGE CONNECTIONS. IE. REPLACE APPROPRIATE SECTION OF THINNED PIPING. (FOUND THIN AND LEAKING.)
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Documentation
Issued 22 September 1988
Resolved
DRAFT AND SUBMIT FOR APPROVAL, AN APPENDIX TO THE VESSEL'S CURRENTLY APPROVED OPERATING MANUAL, DETAILING PRODUCTION OPERATIONS, EMERGENCY RESPONSE ACTION AND RESPONSIBILITIES, AND VESSEL MOVEMENT PROCEDURES.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Electrical
Issued 22 September 1988
Resolved
REPLACE MISSING COVER PLATE INSIDE THE EMERGENCY LIGHTING PANAL.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Fire Fighting
Issued 22 September 1988
Resolved
POST MISSING INSTRUCTION PLACARDS FOR THE FIXED CO2 EXTINGUISHING SYSTEM FOR THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Electrical
Issued 22 September 1988
Resolved
REMOVE 480V/3PHASE FEEDER FOR "SUMP PUMP" FROM EMERGENCY SWITCHBOARD, AS IT IS NOT A VITAL LOAD.
Condition: Unknown
Due 22 September 1988
Resolved 22 September 1988
Electrical
Issued 15 July 1988
Resolved
CONDUCTED HOUR TEST OF THE EMERGENCY GENERATOR PER 46 CFR 109.211, NVC 4-78
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Documentation
Issued 15 July 1988
Resolved
PROVIDE EVIDENCE THAT THE STABILITY CALCULATIONS FOR THE PERIOD SINCE 1978,HAVE BEEN SUBMITED TO THE COAST GUARD FOR APPROVAL REFLECTING WEIGHT ADDITIONS TO THE VESSEL.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Electrical
Issued 15 July 1988
Resolved
PROVE PROPER OPERATION OF THE AUTOMATIC BUS TRANSFER FOR THE EMERGENCY GENERATOR PER 46 CFR 112(OLD "J") AND DEMONSTRATE OVERSPEED SHUTDOWN NOT TO EXCEED 115% OF RATED RPM PER ABS RULES.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Fire Fighting
Issued 15 July 1988
Resolved
UPDATE AND RESUBMIT FIRE CONTROL PLAN FOR APPROVAL. PLAN CURRENTLY SHOWS EQUIPMENT THAT DOES NOT MATCH THE EXISTING LOCATIONS.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Construction/Loadline
Issued 15 July 1988
Resolved
PROVIDE EVIDENCE OF USCG APPROVAL INSTALLATION OF NEW HELICOPTER DECK & ASSOCIATED PIPING INCLUDING STABILITY REVIEW.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Electrical
Issued 15 July 1988
Resolved
PROVE PROPER OPERATION OF THE REMOTE VENTILATION SHUTDOWN.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Documentation
Issued 15 July 1988
Resolved
PROVIDE ON BOARD THE VESSEL AND POST THE STABILITY LETTER DATED 5 OCTOBER 1978 ALSO PROVIDE ON BOARD THE RIG AND PLACE IN THE OPERATING MANUAL THE APPROVAL LETTER DATED 28 APRIL 1978.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Electrical
Issued 25 August 1987
Resolved
REPAIR OR PROVIDE THE FOLLOWING ITEMS FOR THE EMERGENCY GENERATOR ROOM: 1 REMOTE FULE SHUT OFF, 2 FLAME SCREEN FOR FUEL OIL DAY TANK VENT (SKID TANK)3. MAKE OPERATIONAL ALL VENT LOUVERS, 4. REPLACE MISSING PANEL FOR THE SWTCBOARD, 5. REPLACE MISSING WALL COVERING SHEATHING.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Fire Fighting
Issued 25 August 1987
Resolved
PROVIDE ONBAORD THE VESSEL UL-CG APPROVED PORTABLE AND SEMI PORTABLE FIRE EXTINGUISHERS AS NECESSARY TO REPLACE NON-CG APPROVED EXTINGUISHERS
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Fire Fighting
Issued 25 August 1987
Resolved
UPATE AND RESUBMIT FIRE CONTROL PLAN FOR APPROVAL. PLAN CURRENTLY SHOWS EQUIPMENT THAT DOES NOT MATCH THE EXISTING LOCATIONS.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Documentation
Issued 25 August 1987
Resolved
PROVIDE EVIDENCE THAT THE STABILITY CALCULATIONS, FOR THE PERIOD SINCE 1978HAVE BEEN SUBMITTED TO THE COAST GUARD FOR APPROVAL REFLECTING WEIGHT A ADDITIONS TO THE VESSEL
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Lifesaving
Issued 25 August 1987
Resolved
PROVIDE FOLLOWING ITEMS:1. 4 NO.2 LIFEBOATS,2.12 CG APPROVED HAND-HELD FLAR3. 12 PISTOL PARACHUTE FLARES, 4. LIGHT STICKS FOR COMPASS, 5.INTERIOR LGHT6. 1 ADDITIONAL PULLING OAR, 7. USCT APPROVED RATIONS & WATER. EXISTING STOCKS OF FOOD AND WATER TO BE KEPT UNTIL REPLACED BY CG APPROVED ITEMS.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Lifesaving
Issued 25 August 1987
Resolved
MAKE EQUIPMENT IN NO.1 LIFEBOAT AVAILABLE FOR EXAMINATION & INVENTORY BY USCG INSPECTOR. INSURE ALL RATIONS WATER & PYROTECHNICS ARE USCG APPROVED
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
REPAIR OR REPLACE THE FOLLOWING ITEMS FOR THE EMERGENCY GENERATOR: 1. REMOVELECTRICAL CABLE RUNNING THROUGH VENT LOUVERS (LOGGING UNIT)2. PROPERLY SUPPORT ALL ELECTRICAL CABLES RUNNING TO AND FROM SWITCH BOARD. 3. PROVIDE PROPER BULKHEAD PENITRATIONS FOR ELECTRICAL CABLES,4.REMOV UNSUPP.CABLES DK
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
REPAIR OR REPLACE, RUSTED OUT CABLE HANGER ON THE MAIN DECK STARBOARD SIDE FORWARD.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Fire Fighting
Issued 25 August 1987
Resolved
NUMBER ALL FIRE STATIONS ON THE RIG IN CONTRASING COLORS 46 CFR 109,NVC 4078
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Navigation
Issued 25 August 1987
Resolved
REPAINT AS NECESSARY THE LOAD LINE, CLEAN AS REQUIRED THE DRAFT MARKS.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Navigation
Issued 25 August 1987
Resolved
MAKE OPERATIONAL THE VESSELS FOG HORN. AUDIOABILITY SHALL CONFORM TO THE "COLREGS"
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
CLEAN AS NECESSARY THE NAVIGATION BATTERIES. ELECTRICAL LEADS SHALL ALSO BECLEANED AND OR REPAIRED. LINE GENERAL ALARM BOX WITH LEAD OR FIBERGLASS
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Lifesaving
Issued 25 August 1987
Resolved
SUBMIT FOR APPROVAL THE USE OF JACOBS LADDER & PROVIDE COAST GUARD APPROVEDJACOBS LADDERS. JACOBS LADDER LOCATION SHALL BE REFLECTED ON THE FIRE CONTROL PLAN.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Fire Fighting
Issued 25 August 1987
Resolved
REPLACE ALL LOW VELOCITY FOG APPLICATOR TIPS WITH NON-CLOGGING TYPE.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Lifesaving
Issued 25 August 1987
Resolved
REPAIR OR REPLACE THE ELECTRICAL CONTROLLER BOX FOR THE PORT LIFEBOAT.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Deck/Cargo
Issued 25 August 1987
Resolved
REMOVE THE EXCESSIVE OIL FROM THE CATCH ARE (CONTAINMENT) UNDER THE PRODUCTION EQUIPMENT
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Lifesaving
Issued 25 August 1987
Resolved
CHANGE FUEL IN BOTH LIFEBOATS. OPERATE BOTH BOATS IN WATER TO DEMONSTRATE AHEAD & ASTERN PROPULSION. FUNCTIONING OF WATER SPRAY SYSTEM AND RELEASINGGEAR
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Lifesaving
Issued 25 August 1987
Resolved
CLEAN OR REPLACE HELMSMAN WINDOW ON NO.2 LIFEBOAT.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Deck/Cargo
Issued 25 August 1987
Resolved
PROVIDE ACME APPROVED RELIEF VALVES WITH HAND RELIEVING DEVICES FOR ALL BULTANKS. VALVES TO BE SET TO RELEIVE AT NOT MORE THAN 40 PSI.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Fire Fighting
Issued 25 August 1987
Resolved
REPAIR LEAKS IN FOAM PIPING, FOAM PUMP AND TANK AREA
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Construction/Loadline
Issued 25 August 1987
Resolved
PROVIDE EVIDENCE OF USCG APPOVAL FOR INSTALLATION OF NEW HELICOPTER DECK & ASSOCIATED PIPING INCLUDING STABILITY REVIEWS. PROPERLY SECURE PERIMETER NETTING ON HELO DECK, INSTALL TAIL ROTOR WARNING SIGNS IN ENGLISH, PROVIDE ADDITIONAL R-V FIRE EXTINGUISHER.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Lifesaving
Issued 25 August 1987
Resolved
PROVIDE 12 CG APPROVED PARACHUTE FLARES FOR THE VESSEL
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Lifesaving
Issued 25 August 1987
Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE FIRST AID KITS: ONE TOURNIQUET ONE EACH LEG AND ARM SPLINTS ONE BURN BLANKET 21 TRIANGULAR BANDAGES ONE BACKBOARD
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Engineering
Issued 25 August 1987
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION THE RIG FLOOR AND TWO COMPRESSOR RM AIR RECEIVERS TEST RELIEF VALVES FOR THE AIR RECEIVERS
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Engineering
Issued 25 August 1987
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION ALL "APV" BOTTLES (AIR RECEIVERS) TEST RELIEF VALVES FOR "APV" BOTTLES
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Engineering
Issued 25 August 1987
Resolved
REPAIR OR REPLACE LEAKING SALT WATER HEADER ON RIG AIR COMPRESSOR.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Deck/Cargo
Issued 25 August 1987
Resolved
DEMONSTRATE PROPER OPERATION OF THE MUD PUMP RELIEF VALVES.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
CONDUCT REQUIRED TESTS OFF NO.4 EMD UPON COMPLETION OF REPAIRS: OVERSPEED LOW LUBE OIL SHUT DOWN AND HIGH WATER JACKER ALARM AND REVERSE POWER.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Fire Fighting
Issued 25 August 1987
Resolved
PROVIDE ONE ADDITIONAL B-II PORTABLE FIRE EXTINGUISHER IN THE IMMEDIATE VACINITY OF THE THREE ELECTRIC MOTORS, PRODCUTION DECK, FOR THE OIL TRANSFRPUMPS
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
PROVE PROPER OPERATION OF THE REMOTE VENTILATION SHUT DOWN.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Navigation
Issued 25 August 1987
Resolved
REPAIR THE SOUND POWERED PHONE IN THE STARBOARD ELEVATOR. UNITS WILL SHOCK THE OPERATOR. REPAIR THE PA SYSTEM IN BOTH PUMP ROOMS, UNITS ARE NOT CLEARLY AUDIBLE.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
REPAIR THE FOLLOWING ELECTRICAL INSTALLATIONS IN THE HAZARDOUS LOCATIONS; ELECTRICAL CABLE TO DRINKING FOUNTAIN-DRILL FLOOR, PROVDE EVIDENCE SUB SEA BOX IS EXPLOSION PROOF-DRILL FLOOR, REMOVE DEAD END WIRE AND REPAIR CABLE PULLED OUT OF SYS FITTING BEHIND DRILLER CONSOLE.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
REPAIR OR REPLACE THE FOLLOWING; ALL DOORS TO BE SELF CLOSING AND GAS TIGHTMUD PIT AIR FLOW ALARMS AND ONE LIGHT FIXTURE WITH LOSE END CAP.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Lifesaving
Issued 25 August 1987
Resolved
PROVIDE USCG APPROVED LINE THROWING APPLIANCE
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Deck/Cargo
Issued 25 August 1987
Resolved
REPAIR OR REPLACE THE MAIN HOIST AND WHIP LINE LIMIT SWITCHES ON BOTH CRANEREPLACE BROKEN CABIN GLASS ON THE STARBOARD CRANE.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Accommodation/Occupational Safety
Issued 25 August 1987
Resolved
PROVE PROPER OPERATION OF THE MARINE SNAITATION DEVICE.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Fire Fighting
Issued 25 August 1987
Resolved
HYDROSTATICALLY TEST THE FOAM TANK TO 1 AND HALF TIMES THE MAWP. ONE RETAINING RING IS SEVERLY RUSTED AND INTO THE TANK PLATING, THE OTHER BAND IS BROKEN DUE TO RUST.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Construction/Loadline
Issued 25 August 1987
Resolved
MAKE THE WATERTIGHT DOOR TO THE NUMBER 3 THRUSTER ROOM WATER TIGHT. LINES PIERCING BULKHEAD HAVE NOT BEEN PROPERLY PACKED. THE INSPECITON OF THRUSTEROOMS 1-2-4 PENDS
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Accommodation/Occupational Safety
Issued 25 August 1987
Resolved
REPLACE MISSING OVERHEAD PANEL IN AC ROOM NEXT TO BALLAST CONTROL ROOM
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Construction/Loadline
Issued 25 August 1987
Resolved
REPAIR THE FOLLOWING ITEMS IN THE PORT PUMP ROOM; MOUNT PA SPEAKER, POWER VALVES #1,73,71,25,21 45 (REPACK) 13,19,89. ELECTRICAL CABLES TO VALVES 69,51,57,19
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Construction/Loadline
Issued 25 August 1987
Resolved
REPAIR THE FOLLOWING ITEMS IN THE STBD PUMP ROOM; POWER VALVES #84,40,42, 36, DRILL WATER LINE LEAKING.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Construction/Loadline
Issued 25 August 1987
Resolved
BALLAST CONTROL PANEL 100% FILL INDICATION LIGHTS NOT WORKING, FALSE INDICATIONS FOR VALVES 35,15,67,53,29,84,2,42,40,36,32,34. MAKE OPERATIONLAS NECESSARY
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Documentation
Issued 25 August 1987
Resolved
PROVIDE ON BOARD THE VESSEL AND POST THE STABILITY LETTER DATED 5OCT78. ALSO PROVIDE ON BAORD THE RIG AND PLACE IN THE OPERATING MANUAL THE APPROVALTR DATED 28APR78.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
CONDUCTED TWO HOUR TEST OF THE EMERGENCY GENERATOR PER 46 CFR 109.211, NVC 4-78
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
PROVE PROPER OPERATION OF THE AUTOMATIC BUSS TRANSFER FOR THE EMERGENCY GENERATOR PER 46 CFR 112 (OLD "J") AND DEMONSTRATE OVERSPEED SHUTDOWN NOT TO EXCEED 115% OF RATED RPM PER ABS RULES.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Construction/Loadline
Issued 25 August 1987
Resolved
PROVIDE THE REQUIRED AIR PRESSURE (BREATHING AIR), FORWARD BOTTLE #2 LIFEBOAT
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Lifesaving
Issued 25 August 1987
Resolved
MAKE NECASSARY REPAIRS TO NO.1 LIFEBOAT DAVITS
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
PROVIDE MISSING COVER PLATE FOR THE ELECTRIC CABLE TO MOTOR CONNECTION ON THE NO.2 WATERMAKER
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Construction/Loadline
Issued 25 August 1987
Resolved
COMPLETE SPECIAL EXAM IN LIEU OF DRYDOCKING, NO LATER THAN 25OCT87
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Construction/Loadline
Issued 2 May 1987
Resolved
IN EACH PUMP ROOM, SWITCHES ON MOTOR CONTROLLERS TO VALVES AND PUMPS MUST BE FREED UP FOR SMOOTH OPERATION.
Condition: Unknown
Due 2 May 1987
Resolved 2 May 1987
Documentation
Issued 2 May 1987
Resolved
PROVIDE VALID DOCUMENTATION CERTIFICATE. PRESENT DOCUMENTATION HAS EXPIREDON 30 APRIL 1987. 46CFR 67.01-5
Condition: Unknown
Due 2 May 1987
Resolved 2 May 1987
Fire Fighting
Issued 28 July 1986
Resolved
REMOVE ALL FLAMMABLE AND COMBUSTIBLE FLUIDS IN STOREROOM ADJACENT TO LIVING QUARTERS. ALSO THIS CHEMICAL TREATMENT ROOM MUST BE REMOVED FROM LIVING QUARTER'S AREA. APPROVAL FROM USCG (MMT) PRIOR TO ESTABLISHING A CHEMICAL ROOM ABOARD RIG.
Condition: Unknown
Due 28 July 1986
Resolved 28 July 1986
Lifesaving
Issued 28 July 1986
Resolved
PROVIDE ANNUAL SERVICING CERTIFICATES FOR TWO 25 MAN RAFTS ABOARD RIG.
Condition: Unknown
Due 28 July 1986
Resolved 28 July 1986
Electrical
Issued 28 July 1986
Resolved
REPLACE MICROPHONE IN MUD PIT ROOM WITH A CLASS I DIV II APPROVED TYPE.
Condition: Unknown
Due 28 July 1986
Resolved 28 July 1986
Lifesaving
Issued 28 July 1986
Resolved
HAVE THROWOVER RAFTS HYDROSTATIC RELEASING GEAR MECHANISMS ANNUALLY SERVICED.
Condition: Unknown
Due 28 July 1986
Resolved 28 July 1986
Deck/Cargo
Issued 28 July 1986
Resolved
REPLACE PRESSURE GAUGE ON DISCHARGE SIDE OF FIRE PUMP IN STARBOARD PUMPROOM.
Condition: Unknown
Due 28 July 1986
Resolved 28 July 1986
Unknown
Issued 20 August 1985
Resolved
PROVIDE (2) TWO ASME APPROVED RELIEF VALVES WITH HAND RELIEVING DEVICES FOR AIR RECEIVERS IN THE COMPRESSOR ROOM. 46 CFR54.
Condition: Unknown
Due 20 August 1985
Resolved 20 August 1985
Lifesaving
Issued 20 August 1985
Resolved
PROVIDE EMERGENCY STATION LIGHTS FOR ALL FOUR LIFERAFT STATIONS. 46CFR111.75-15(E)(4).
Condition: Unknown
Due 20 August 1985
Resolved 20 August 1985
Deck/Cargo
Issued 20 August 1985
Resolved
PROVIDE A FIXED PIPING FUELING LINE FOR THE EMERGENCY GENERATOR. 46CFR56-50-75.
Condition: Unknown
Due 20 August 1985
Resolved 20 August 1985
Deck/Cargo
Issued 20 August 1985
Resolved
REMOVE THE NON-APPROVED FUEL HOSE FROM THE STARBOARD CRANE STATION OR INSTALL APPROVED PIPING FOR THIS FUELING STATION. 46CFR56-50-75.
Condition: Unknown
Due 20 August 1985
Resolved 20 August 1985
Deck/Cargo
Issued 20 August 1985
Resolved
HAVE BOTH CRANES TESTED FOR ISSUANCE OF QUADRENNIAL CERTIFICATE. THIS TESTIS TO BE CONDUCTED BY BY AN APPROVED AUTHORITY AND DONE IN ACCORDANCE WITH API-2C STANDARDS. 46CFR109.439
Condition: Unknown
Due 20 August 1985
Resolved 20 August 1985
Lifesaving
Issued 20 August 1985
Resolved
PROVIDE EVIDENCE THAT (1) ONE 25 MAN LIFERAFT HAS BEEN ANNUALLY SERVICED. 46CFR107.231(B).
Condition: Unknown
Due 20 August 1985
Resolved 20 August 1985
Unknown
Issued 9 October 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU PENROD 71, DN562372
Condition: Unknown
Due 9 October 1984
Resolved 9 October 1984
Fire Fighting
Issued 9 October 1984
Resolved
PROVIDE FOR THE TWO FIREMEN OUTFITS, OXYGEN METERS WITH THE PROPER APPROVAL LABELS AS REQUIRED BY 46 CFR 108.497[C].
Condition: Unknown
Due 9 October 1984
Resolved 9 October 1984
Unknown
Issued 9 October 1984
Resolved
SUBMIT TO THE COAST GUARD, FOR APPROVAL A CONSTRUCTION PORTFOLIO WITH THE INFORMATION REQUIRED BY 46 CFR 107.305[HH].
Condition: Unknown
Due 9 October 1984
Resolved 9 October 1984
Documentation
Issued 16 August 1983
Resolved
SUBMIT PLANS FOR APPROVAL FOR PROPOSED NEW HELO DECK.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Fire Fighting
Issued 16 August 1983
Resolved
SUBMIT FIRE CONTROL PLANS FOR REVIEW BY USCG.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Unknown
Issued 16 August 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU PENROD 71, DN562372.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Fire Fighting
Issued 16 August 1983
Resolved
REPLACE RELIEF VALVES IN FIRE MAIN SYSTEM.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Fire Fighting
Issued 16 August 1983
Resolved
COMPLETE REINSTALLATION OF HYDRO-TESTED BOTTLES IN FIXED CO2 SYSTEM.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Fire Fighting
Issued 16 August 1983
Resolved
REPLACE ALL NON-USCG/UL APPROVED PORTABLE AND SEMI-PORTABLE EXTINGUISHERS.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Unknown
Issued 16 August 1983
Resolved
PROVIDE EQUIPMENT MARKINGS AND INSTRUCTIONS IAW 46 CFR PART 6.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Lifesaving
Issued 16 August 1983
Resolved
REPLACE THE NON-USCG APPROVED FOOD WATER AND FLARES IN THE TWO (2) LIFE- BOATS.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Electrical
Issued 16 August 1983
Resolved
COMPLETE THE REPLACEMENT OF SILICONE IN EYS SEALS WITH CHICOX.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Deck/Cargo
Issued 16 August 1983
Resolved
REPLACE OR REPAIR THE DENTED PRESSURE VESSEL AT THE DRILL STRING CONPEN- SATOR.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Electrical
Issued 16 August 1983
Resolved
SUBMIT HAZARDOUS AREA DRAWING FOR REVIEW AND APPROVAL BY USCG.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Fire Fighting
Issued 16 August 1983
Resolved
REPLACE ALL NON-USCG APPROVED MARINE ALL PURPOSE NOZZLES.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Electrical
Issued 16 August 1983
Resolved
PROVIDE EYS SEALS ON DRAWWORKS ON BLOWER MOTORS.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983
Electrical
Issued 16 August 1983
Resolved
PROVIDE PURGE AND ALARM FOR DRAWWORKS CONNECTIONS.
Condition: Unknown
Due 16 August 1983
Resolved 16 August 1983