Inspection history · 129
20 September 2007
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3062338
5 August 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3018321
23 June 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2974535
9 April 2007
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2904218
25 March 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2895324
1 February 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2878341
20 October 2006
MTSA Verification · Annual Inspection · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2804598
2 October 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2791889
13 March 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2601289
9 March 2006
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2599939
24 February 2006
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2591124
16 February 2006
Permit to Proceed · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2586864
9 February 2006
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2554809
5 December 2005
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2547301
25 October 2005
Annual Inspection · MTSA Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2521949
21 June 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2397885
14 June 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2390178
11 January 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2272939
30 August 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2221035
21 July 2004
Internal Structural Exam · Cargo Tank Internal · Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2140636
17 June 2004
MTSA Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2114624
16 October 2003
Periodic Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1929934
20 August 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995368
3 July 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1897820
26 September 2002
Hull Examination · MARPOL Annex I Examination · Annual Inspection · Cargo Tank Internal · Internal Structural Exam · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1667667
25 June 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1635973
9 May 2002
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1600101
7 March 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1492142
17 October 2001
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1422138
13 October 2001
Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1373640
26 September 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1407021
14 December 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 461385
21 November 2000
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 824651
9 November 2000
Examination of Repairs · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 823951
30 October 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 283670
19 August 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 281512
10 July 2000
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1410360
26 June 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 473572
14 March 2000
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 816644
16 February 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 136671
11 September 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 529674
8 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 770341
7 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 197653
3 August 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1111749
30 July 1999
Examination of Repairs · Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1395241
8 March 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 73506
24 February 1999
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1131843
20 February 1999
Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 798127
19 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 4608
9 January 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 510682
12 November 1998
Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1429051
10 November 1998
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 804918
5 November 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 150877
7 October 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 500004
10 August 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 800310
10 July 1998
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1419972
29 March 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 492667
2 February 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 667012
11 December 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 779323
22 October 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 667007
14 October 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 148604
27 September 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 513814
26 August 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 158851
22 August 1997
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1431840
13 April 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 480119
9 April 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 161560
24 November 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 537770
18 November 1996
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 866770
27 August 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 445196
29 July 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1086468
24 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 667001
15 July 1996
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1398494
22 June 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 530202
5 December 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 488114
16 August 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 535051
8 June 1995
Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 882595
18 May 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 491195
31 January 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 448499
22 January 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 469729
9 July 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 443332
29 June 1994
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1170951
2 December 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 532683
7 September 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 360614
23 July 1993
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 847499
1 March 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 839438
15 September 1992
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1258264
3 August 1992
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1134012
3 August 1992
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1249252
23 April 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 497198
8 March 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 349272
26 August 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 480635
10 July 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 666967
12 June 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 344369
30 May 1991
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1226643
26 February 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 522694
31 October 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1240471
25 August 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 456708
16 July 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1240627
5 June 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 497747
9 April 1990
Deficiency Check · Re-Inspection · Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 915227
15 March 1990
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 919298
10 December 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 439146
8 November 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1307998
8 October 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 459833
26 September 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 897864
27 June 1989
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1209433
5 June 1989
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208944
24 March 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 534263
26 September 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 477659
15 August 1988
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1351754
23 May 1988
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1352490
19 March 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 453806
28 October 1987
MARPOL Annex II Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1017454
18 August 1987
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 528772
6 August 1987
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1028930
26 February 1987
Re-Inspection · Drydock Extension
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1004758
21 January 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 465551
18 November 1986
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 492395
19 March 1986
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1303129
14 March 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306906
5 March 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 453009
15 January 1986
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 994277
3 December 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 487943
17 May 1985
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 983645
23 April 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 301560
11 March 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1287328
15 February 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1282330
29 April 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280827
25 March 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971787
Construction/Loadline › Hull › Bottom Plating
Issued 16 February 2006
Resolved
Issued PTP to allow vessel to load cargo in New Orleans, Louisiana, and transit to Tampa, Florida, to off-load and effect permanent repairs to 5 inch hairline fracture observed in way of #1 Port Cargo Tank, located approximately 2 ft forward of the #1 transverse bulkhead, just inboard of the #5 bottom longitudinal, approximately 12 ft from the centerline bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 24 February 2006
Resolution: Examined satisfactory repairs in the #1 port cargo tank and reissued COI.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 October 2003
Resolved
Replace/repair missing dogs on STBD deck office AC Box. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Condition: Improper/Lack of Maintenance
Due 16 November 2003
Resolved 2 November 2003
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 16 October 2003
Resolved
Repairs wasted through metal areas on AC Box aft of STBD deck office.
Condition: Improper/Lack of Maintenance
Due 16 November 2003
Resolved 23 October 2003
Resolution: Wasted through areas repaired with red-hand until vessel can go to Dry dock and have permanent repairs made.
Construction/Loadline › Structures
Issued 16 October 2003
Resolved
Replace/repair missing dogs on Port aft engine house vent hatch. LEGACY COMPONENT DESC: Ventilators
Condition: Improper/Lack of Maintenance
Due 16 November 2003
Resolved 2 November 2003
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 16 October 2003
Resolved
Provide High Level and Overfill Level alarm signs at goal posts. LEGACY COMPONENT DESC: Liquid Overfill Protection
Condition: Improper/Lack of Maintenance
Due 8 December 2003
Resolved 2 September 2004
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 16 October 2003
Resolved
Replace/repair dogs on Port aft deck hatch access to aft rake.
Condition: Improper/Lack of Maintenance
Due 16 November 2003
Resolved 23 October 2003
Resolution: Missing dogs replaced on Port aft deck hatch access to aft rake.
Engineering › Lubricating Oil Storage/Transfer System
Issued 16 October 2003
Resolved
Replace/repair two (2) broken hydraulic valves at port side hydraulic tank. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 16 November 2003
Resolved 2 November 2003
Electrical › Electric Supply System (service)
Issued 16 October 2003
Resolved
Secure engine house battery cable from loose arrangement on port side deck leading to air compressor. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Due 16 November 2003
Resolved 31 October 2003
Electrical › Electrical Distribution System (service)
Issued 16 October 2003
Resolved
Blank exposed opening in circuit box located in port side engine house. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Due 16 November 2003
Resolved 2 November 2003
Engineering › Lubricating Oil Storage/Transfer System
Issued 16 October 2003
Resolved
Repair leak in hydraulic pump line on generator side of engine house. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 16 November 2003
Resolved 31 October 2003
Engineering › Lubricating Oil Service System
Issued 16 October 2003
Resolved
Clean engine house of oil residue and sludge on deck to minimize fire hazards LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 16 November 2003
Resolved 2 November 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 16 October 2003
Resolved
Make temporary repairs to fuel leak at base of pump house #1. LEGACY COMPONENT DESC: Cargo Pump
Condition: Improper/Lack of Maintenance
Due 16 November 2003
Resolved 31 October 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 16 October 2003
Resolved
Make permanent repairs at next dry dock to fuel leak at base of pump house #1at next dry dock or prior to July 31, 2004
Condition: Improper/Lack of Maintenance
Due 31 July 2004
Resolved 2 September 2004
Construction/Loadline › Structures › Deck Plating
Issued 16 October 2003
Resolved
Replace/repair wasted area of pinholes in plate under deck office door at next dry dock or prior to July 31, 2004 LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Due 31 July 2004
Resolved 2 September 2004
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 16 October 2003
Resolved
Make permanent repairs to wastage IWO AC box housing at starboard aft deck office at next dry dock or prior to July 31, 2004. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Condition: Improper/Lack of Maintenance
Due 31 July 2004
Resolved 2 September 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 16 October 2003
Resolved
Provide gauging report for underside of port hydraulic fluid tank at next Dry dock or prior to July 31, 2004. LEGACY COMPONENT DESC: Cargo Pump
Condition: Improper/Lack of Maintenance
Due 31 July 2004
Resolved 2 September 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 16 October 2003
Resolved
Provide Marine Survey for underside of port pump house #4 for deck steel wastage IWO underside aft of pump engine at next Dry dock or prior to July 31, 2004. LEGACY COMPONENT DESC: Cargo Pump
Condition: Unknown
Due 31 July 2004
Resolved 2 September 2004
Operations/Management › Non-double Hull Tank Barges
Issued 26 September 2002
Resolved
Provide copy of the plan implemented to comply with enhanced survey requirements per 33 CFR 157.430 LEGACY COMPONENT DESC: Enhanced Survey Report
Due 26 October 2002
Resolved 21 October 2002
Electrical › Electrical Distribution System (service)
Issued 26 September 2002
Resolved
Removed unnecessary wirings and open end wirings in aft machinery space. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 10 October 2002
Resolved 27 September 2002
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 26 September 2002
Resolved
Prove proper operation of high level audible alarm to the satisfaction of cognizant OCMI prior to loading cargo.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2002
Resolution: Corrected upon completion of the examination.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 4 September 2002
Resolved
Replace missing coaming drains plug.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2002
Deck/Cargo
Issued 13 October 2001
Resolved
Barge representative is to determine the cause of product being in the cofferdam around the notch and make permanent and proper repairs to the satisfaction of the attending US Coast Guard Inspector.
Condition: Unknown
Due 13 October 2001
Resolved 13 October 2001
Unknown
Issued 13 October 2001
Resolved
Barge representative to provide a copy of the ABS Class Surveyors report toMSO Miami prior top departing.
Condition: Unknown
Due 13 October 2001
Resolved 15 October 2001
Unknown
Issued 13 October 2001
Resolved
Barge representative to notify MSO Tampa upon the arrival of the barge in Tampa, to schedule an inspection.
Condition: Unknown
Due 13 October 2001
Resolved 13 October 2001
Deck/Cargo
Issued 26 September 2001
Resolved
ON VAPOR RECOVERY SYSTEM REPLACE HALF INCH STUDS ON VAPOR FLANGES CURRENTLYBROKEN AND NOT BEING USED WHEN VAPOR LINE FROM FACILITY IS HOOKED UP. COMPLETED PRIOR TO NEXT LOADING WITH VRS.
Condition: Unknown
Due 26 October 2001
Resolved 26 September 2002
Deck/Cargo
Issued 9 November 2000
Resolved
REMOVE PRODUCT FROM STERN NOTCH VOID AND MAKE COMPARTMENT GAS-FREE PRIOR TODEPARTURE FROM THE PORT OF NEW ORLEANS.
Condition: Unknown
Due 13 November 2000
Resolved 14 November 2000
Deck/Cargo
Issued 9 November 2000
Resolved
MAKE PERMANENT AND PROPER REPAIRS TO #7 PORT AND/OR STARBOARD CARGO TANKS.
Condition: Unknown
Due 9 December 2000
Resolved 14 November 2000
Engineering
Issued 30 July 1999
Resolved
REPAIR LEAKING FUEL LINES ON THE #2 AND #3 CARGO PUMP ENGINES. TO BE WITNESSED PRIOR TO DISCHARGE OF CARGO.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Engineering
Issued 30 July 1999
Resolved
PROVE PROPER OPERATION OF REMOTE SHUTDOWN ON THE #1 CARGO PUMP ENGINE._x001C_
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Deck/Cargo
Issued 12 November 1998
Resolved
Vessel shall proceed to Tampa, Florida for drydock repair of # 7 port cargo tank, and submit a report of completion of repairs to the Coast GuardMSO. No cargo is to be carried prior to repairs being made.
Condition: Unknown
Due 7 December 1998
Resolved 7 December 1998
Deck/Cargo
Issued 10 July 1998
Resolved
PRIOR TO 10 AUGUST 1998, PROVE SATISFACTORY OPERATION OF THE VESSEL'S P/V VALVES.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Engineering
Issued 22 August 1997
Resolved
Test pressure relief valves on both pressure vessels, (air receivers).
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Unknown
Issued 22 August 1997
Resolved
Towing vessel FREEDOM, On. D615200 to prove compliance with part IV of NVIC2-97 (Auto Pilot indicator) or request temporary equivalency I.A.W. 33 CFR 157.07.
Condition: Unknown
Due 2 October 1997
Resolved 11 December 1997
Deck/Cargo
Issued 22 August 1997
Resolved
Prove proper operation of pump engine remote shutdowns.
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Deck/Cargo
Issued 22 August 1997
Resolved
Renew missing pressure/vacuum valve flame screens.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Unknown
Issued 22 August 1997
Resolved
CONDUCT CREDIT DRYDOCK EXAMINATION AS REQUIRED BY 46 C.F.R. 31.10-21_x001C_ _x001C_ Vessel was drydocked at 0930 on 19JUL97. Nineteen days past the Certificateof Inspection drydock due date of 30JUN97.
Condition: Unknown
Due 26 August 1997
Resolved 26 August 1997
Documentation
Issued 15 July 1996
Resolved
T/B OCEAN 215 OPERATED FROM 29JUN-15JUL96 WITH AN EXPIRED COI.
Condition: Unknown
Due 15 July 1996
Resolved 24 July 1996
Lifesaving
Issued 15 July 1996
Resolved
PROVIDE ACCEPTABLE AIR RECEIVER RELIEF VALVES FOR BOTH START AIR PRESSURE VESSELS.
Condition: Unknown
Due 31 July 1996
Resolved 1 August 1996
Deck/Cargo
Issued 15 July 1996
Resolved
REAPIR/REPLACE VAPOR RECOVERY SYSTEM MANIFOLD PRESENTATON FLANGE. INSTALLATION TO ENSURE NIPPLE IS IN THE 12 O'CLOCK POSITION.
Condition: Unknown
Due 31 July 1996
Resolved 23 July 1996
Engineering
Issued 8 June 1995
Resolved
Provide protective shield for exhaust diesel cargo.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Deck/Cargo
Issued 8 June 1995
Resolved
Test brake on anchor at sea upon departing port Tampa, log in underway offical record, and fax to MSO Tampa.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Fire Fighting
Issued 8 June 1995
Resolved
Service all fire extinguishers and provide servicing report.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Engineering
Issued 8 June 1995
Resolved
Secure fuel hoses to be away from emergency trip cable for #2 and #3 dieselcargo pumps.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Construction/Loadline
Issued 9 April 1990
Resolved
MAKE PERMANENT REPAIRS TO THE FRACTURED WELD SEAM LOCATED FWD RAKE PORT SIDE SHELL PLATING APPROX. 8' BELOW MAIN DECK NEAR STEM. PERMANENT REPAIRS TO CONSIST OF GAUGING SURROUNDING AREA & CROP & RENEW TO GOOD STEEL. MON. TEMP. REPAIRS. PATCH & NOTIFY OCMI OF PROBLEMS.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Construction/Loadline
Issued 15 March 1990
Resolved
MAKE PERM. REPAIRS TO THE FRACTURED WELD SEAM LOCATED FWD RAKE PORT SIDE SHELL PLATING APPROX. 8' BELOW MAIN DECK NEAR STEM. PERM. REPAIRS TO CONSIST OF GAUGING SURROUNDING AREA AND CROP AND RENEW TO GOOD STEEL. MONITOR TEMP. PATCH AND NOTIFY OCMI OF ANY PROBLEMS.
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Construction/Loadline
Issued 27 June 1989
Resolved
MAKE PERMANENT REPAIRS TO PORT AND STARBOARD BOW RAKE IN WAY OF HEAD LOG ASREQUIRED BY ATTENDING COAST GUARD INSPECTOR. REPAIRS ARE TO BE COMPLETED ATNEXT DRYDOCK OR SCHEDULED DRYDOCK; WHICHEVER COMES FIRST.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Deck/Cargo
Issued 5 June 1989
Resolved
INSURE ALL NONRISING STEM VALVES ARE PROVIDED WITH INDICATORS TO SHOW CLEARLY WHETHER THE VALVE IS OPENED OR CLOSED (12 NONRISING STEM VALVES ON DECK WITHOUT INDICATORS). 46 CFR 56.20-9(A)
Condition: Unknown
Due 5 June 1989
Resolved 5 June 1989
Deck/Cargo
Issued 14 March 1986
Resolved
CONDUCT OPERATIONAL TEST OF REMOTE SHUTDOWNS FOR ALL CARGO PUMPS (4 TOTAL)
Condition: Unknown
Due 14 March 1986
Resolved 14 March 1986
Construction/Loadline
Issued 15 February 1985
Resolved
GAS FREE VESSEL AND EFFECT PERMANENT REPAIRS TO 8' X 12' DAMAGED AREA ON PORT SIDE BOW COMPARTMENT. THE REQUIREMENTS SHALL BE COMPLETED TO THE SATISFACTION OF THE [name withheld], FL. AND PRIOR TO ANY FURTHER CARGO LOADING OR TRANSITS OUT OF THE TAMPA BAY.
Condition: Unknown
Due 15 February 1985
Resolved 15 February 1985