Records from 1985 to 1998. Most recent: inspection, 16 March 1998.
Documentation record
Registered dimensions (L × B × D)400.1 ft × 99.6 ft × 19.1 ft
Registered tonnagegross 6,642 / net 6,642
ITC dimensions (L × B × D)382.6 ft × 99.5 ft × 20.0 ft
ITC tonnagegross 5,756 / net 1,726
BuilderBETHLEHEM STEEL CORP · SAN FRANCISCO, CA, UNITED STATES · built 1975
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 13 April 1998 · expires 30 April 2001
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6642 - Regulatory (Subpart C or D), Gross Ton
5756 - Convention (Subpart B), Gross Ton
6642 - Regulatory (Subpart C or D), Net Ton
1726 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
16 March 1998
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1109096
8 May 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 8595
3 October 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1377827
30 April 1996
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1083040
23 June 1995
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 881551
7 March 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 484346
27 June 1994
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1440821
15 July 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 160079
7 December 1992
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1134502
20 December 1991
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 936384
17 October 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 643097
7 August 1991
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 477885
12 March 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1219752
26 February 1991
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 922735
19 April 1990
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1213002
6 April 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 928254
21 March 1990
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1242687
4 October 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 495495
10 March 1989
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1205790
17 August 1988
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1038382
7 August 1987
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1030218
28 August 1986
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 991292
9 October 1985
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1294204
Construction/Loadline
Issued 30 April 1996
Resolved
CONDUCT WATER WELD TESTS ON DECK PLUGS WHERE ELECTRICAL STUFFING TUBES WEREREMOVED.
Condition: Unknown
Due 30 April 1996
Resolved 30 April 1996
Electrical
Issued 30 April 1996
Resolved
REMOVE WIRING FOR UNUSED PORT AND STBD DECK LIGHTS.
Condition: Unknown
Due 21 August 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 20 December 1991
Resolved
INSTALL PERMANENT MARKS FOR LOAD LINE AND PAINT MARKS IN ACCORDANCE WITH LOAD LINE CERTIFICATE.
Condition: Unknown
Due 24 December 1991
Resolved 21 December 1991
Construction/Loadline
Issued 17 August 1988
Resolved
MAKE REPAIRS AS PER ATTACHED WORKLIST SIGNED AND DATED 17 AUG 1988. ALL REPAIRS TO BE COMPLETED NLT 16 SEP 1988 TO SATISFACTION OF THE COGNIZANT OCMI AND THE ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 17 August 1988
Resolved 17 August 1988
Navigation
Issued 9 October 1985
Resolved
REPAIR OR REPLACE PORT NAVIGATION LIGHT AND PROVE PROPER OPERATION PRIOR TO CARRYING CARGO AND NO LATER THAN 11 OCTOBER 1985 TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 October 1985
Resolved 9 October 1985