MAURY USCG vessel records
← All vessels

ATLANTIC

ATLANTIC is a 1975 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 2016, most recently in January 2020, along with 27 deficiencies — 15 with no resolution recorded —.

Records from 2016 to 2020. Most recent: inspection, 23 January 2020.

Built
1975
Last inspected
23 January 2020
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 January 2020
…with no type recorded1
…past their stated due date15
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD8561
Flag
UNITED STATES
Maury page id
psix-48281

Documentation record

Registered dimensions (L × B × D)48.7 ft × 15.7 ft × 6.5 ft
Registered tonnagegross 38 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderR W GREEN BOAT YARD · DELTAVILLE, VA, UNITED STATES · built 1975
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNY, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

7 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

23 January 2020 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6894801
29 August 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6518704
21 May 2018 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6414884
31 May 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6147754
27 March 2017 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6111992
24 August 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5981625
10 July 2016 Type not recorded
No type recorded · Station Jones Beach · USCG Northeast District (CGD-NE) · Activity 5939389

Deficiency record · 27

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2018 No resolution recorded
Provide proper insulation between engine manifold and cooling water injection point on both main engines. 46 CFR 182.20-20(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2018 No resolution recorded
Ensure marine type fuel strainers(Raycors) do not leak and remove plastic catch buckets affixed to fuel strainers. 46 CFR 182.455(b)(9)
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 August 2018 No resolution recorded
Repair or replace bilge alarm switches in spaces 1 and 2. 46 CFR 182.115(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 August 2018 No resolution recorded
Place a junction box and mechanically secure exposed spiced wiring in the wheelhouse overhead. 46 CFR 183.05-50(b)
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2018 No resolution recorded
Provide proof of annual servicing of fixed CO2 fire fighting system.46 CFR 176.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2018 No resolution recorded
Provide proof of annual servicing of portable fire extinguishers in accordance with NFPA 10. 46 CFR 176.810(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 August 2018 No resolution recorded
Stow EPIRB in a float free and readily accessible area for testing and use.46 CFR 180.40-1(a)(2)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 August 2018 No resolution recorded
Conspicuously mark all life floats with vessel name and the number of persons allowed on each life float.46 CFR 180.20-5(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 August 2018 No resolution recorded
Repair basket netting on forward life float in accordance with 46 CFR 160.027.46 CFR 180.05-1(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 August 2018 No resolution recorded
Replace two paddles and prove proper operation of water light on 10 person life float located forward. 46 CFR 180.15-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 August 2018 No resolution recorded
Mark life buoy with Type II retro reflective material in four equidistant quadrants in accordance with 46 CFR 160.018. 46 CFR 185.604(i)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 29 August 2018 No resolution recorded
Have on board a First Aid kit approved in accordance with 46 CFR 160.041 or equivalent. Must be marked "First-Aid Kit" and easily visible/accessible to crew. 46 CFR 184.710
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 August 2018 No resolution recorded
Provide 2018 editions of Coast Guard Light List, Tide Tables, and Current Tables. Extracts of the publications listed for the area transited may be provided instead.46 CFR 184.420
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 June 2018 No resolution recorded
Vessel is not authorized to carry passengers until permannet repairs are conducted to hull
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2018 — due date passed with no resolution recorded
Construction/Loadline › Hull › Bottom Plating
Issued 21 May 2018 Resolved
Post short hawl for fastner replacement vsl. currently making water at #7 stbd. plank replacement
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2018
Resolved 27 June 2018
Resolution: O/O repaired, water ingress secured
Construction/Loadline › Hull › Bottom Plating
Issued 21 May 2018 No resolution recorded
Post short hawl for fastner replacement vsl. currently making water through out vessel in various locations
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2018 — due date passed with no resolution recorded
Construction/Loadline › Hull › Keel
Issued 21 May 2018 Resolved
Make available for inspection, bilges to be water free
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2018
Resolved 27 June 2018
Resolution: COnducted up close inspection of internals
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 31 May 2017 Resolved
Replace lifejacket retro-reflective tape as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 31 May 2017 Resolved
Replace lifejackets with bladder holes as needed. Restricted to 39 passengers until complete.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 May 2017 Resolved
Replace mast head light prior to night operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 31 May 2017 Resolved
Clean life jacket clasps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 12 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 31 May 2017 Resolved
Stencil name (boat name)on life jackets as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 May 2017 Resolved
Move fuel shut off valve (STBD) sign to forward hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 12 July 2017
Communications › Radio Communications › EPIRB
Issued 31 May 2017 Resolved
Mark name on EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Communications › Radio Communications › EPIRB
Issued 31 May 2017 Resolved
Renew EPIRB battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 August 2016 Resolved
Reair waterlight
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 24 August 2016
Resolution: Corrected on the spot
Documentation › Markings/Placards › Warning Signs
Issued 24 August 2016 Resolved
Label Emergency F/O shutoff valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 24 August 2016
Resolution: Corrected on the spot

Ownership record