Records from 1985 to 2020. Most recent: inspection, 23 January 2020.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 59
23 January 2020
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6894801
29 August 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6518704
21 May 2018
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6414884
31 May 2017
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6147754
27 March 2017
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6111992
24 August 2016
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5981625
10 July 2016
Type not recorded
No type recorded · Station Jones Beach · USCG Northeast District (CGD-NE) · Activity 5939389
26 August 2015
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5225715
21 August 2014
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4961047
1 June 2012
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4327786
23 August 2011
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4123958
4 May 2009
Examination of Repairs · Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3464480
19 June 2008
Simplified Stability Test · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3241203
11 February 2008
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3145757
30 May 2007
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2945998
1 May 2007
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2919577
13 July 2006
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2711202
28 July 2005
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2442657
18 April 2005
Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2336251
14 July 2004
MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2091546
3 September 2003
Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1895381
3 June 2003
MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1805621
7 May 2003
Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1785104
17 April 2002
MARPOL Annex V Examination · COI Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1605078
29 May 2001
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1415662
30 April 2001
Deficiency Check · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1460553
4 April 2000
MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1433625
22 March 2000
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1464924
10 May 1999
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 800437
29 April 1999
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1410065
10 March 1999
MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 804104
22 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1122643
30 April 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1124445
16 May 1997
Hull Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1093888
13 January 1997
Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 786609
20 November 1996
Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1180579
12 March 1996
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1078482
4 May 1995
MARPOL Annex V Examination · Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222355
24 November 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846083
24 March 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 834195
3 March 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 843302
8 April 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1257654
3 December 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1254247
26 March 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 929742
26 March 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1237170
23 May 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927589
23 March 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1213573
28 April 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 966019
3 April 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346876
29 November 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206827
9 November 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 891118
4 May 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1344576
6 April 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 995869
21 May 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031680
28 April 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319989
24 March 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326796
21 April 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 985337
26 November 1985
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 996017
17 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289929
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2018
No resolution recorded
Provide proper insulation between engine manifold and cooling water injection point on both main engines.
46 CFR 182.20-20(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2018
No resolution recorded
Ensure marine type fuel strainers(Raycors) do not leak and remove plastic catch buckets affixed to fuel strainers.
46 CFR 182.455(b)(9)
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 August 2018
No resolution recorded
Repair or replace bilge alarm switches in spaces 1 and 2.
46 CFR 182.115(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 August 2018
No resolution recorded
Place a junction box and mechanically secure exposed spiced wiring in the wheelhouse overhead. 46 CFR 183.05-50(b)
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2018
No resolution recorded
Provide proof of annual servicing of fixed CO2 fire fighting system.46 CFR 176.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2018
No resolution recorded
Provide proof of annual servicing of portable fire extinguishers in accordance with NFPA 10. 46 CFR 176.810(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 August 2018
No resolution recorded
Stow EPIRB in a float free and readily accessible area for testing and use.46 CFR 180.40-1(a)(2)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 August 2018
No resolution recorded
Conspicuously mark all life floats with vessel name and the number of persons allowed on each life float.46 CFR 180.20-5(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 August 2018
No resolution recorded
Repair basket netting on forward life float in accordance with 46 CFR 160.027.46 CFR 180.05-1(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 August 2018
No resolution recorded
Replace two paddles and prove proper operation of water light on 10 person life float located forward. 46 CFR 180.15-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 August 2018
No resolution recorded
Mark life buoy with Type II retro reflective material in four equidistant quadrants in accordance with 46 CFR 160.018. 46 CFR 185.604(i)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 29 August 2018
No resolution recorded
Have on board a First Aid kit approved in accordance with 46 CFR 160.041 or equivalent. Must be marked "First-Aid Kit" and easily visible/accessible to crew. 46 CFR 184.710
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 August 2018
No resolution recorded
Provide 2018 editions of Coast Guard Light List, Tide Tables, and Current Tables. Extracts of the publications listed for the area transited may be provided instead.46 CFR 184.420
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2018 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 June 2018
No resolution recorded
Vessel is not authorized to carry passengers until permannet repairs are conducted to hull
Action required: 17 - Rectify deficiencies prior to departure
Due 27 June 2018 — due date passed with no resolution recorded
Construction/Loadline › Hull › Bottom Plating
Issued 21 May 2018
Resolved
Post short hawl for fastner replacement vsl. currently making water at #7 stbd. plank replacement
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2018
Resolved 27 June 2018
Resolution: O/O repaired, water ingress secured
Construction/Loadline › Hull › Bottom Plating
Issued 21 May 2018
No resolution recorded
Post short hawl for fastner replacement vsl. currently making water through out vessel in various locations
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2018 — due date passed with no resolution recorded
Construction/Loadline › Hull › Keel
Issued 21 May 2018
Resolved
Make available for inspection, bilges to be water free
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2018
Resolved 27 June 2018
Resolution: COnducted up close inspection of internals
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 31 May 2017
Resolved
Replace lifejacket retro-reflective tape as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 31 May 2017
Resolved
Replace lifejackets with bladder holes as needed. Restricted to 39 passengers until complete.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 May 2017
Resolved
Replace mast head light prior to night operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 31 May 2017
Resolved
Clean life jacket clasps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 12 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 31 May 2017
Resolved
Stencil name (boat name)on life jackets as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 31 May 2017
Resolved
Move fuel shut off valve (STBD) sign to forward hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 12 July 2017
Communications › Radio Communications › EPIRB
Issued 31 May 2017
Resolved
Mark name on EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Communications › Radio Communications › EPIRB
Issued 31 May 2017
Resolved
Renew EPIRB battery.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 August 2016
Resolved
Reair waterlight
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 24 August 2016
Resolution: Corrected on the spot
Documentation › Markings/Placards › Warning Signs
Issued 24 August 2016
Resolved
Label Emergency F/O shutoff valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 24 August 2016
Resolution: Corrected on the spot
Lifesaving › Lifebuoys › Serviceable
Issued 26 August 2015
Resolved
Replace damaged ring life buoy on upper deck.
Action required: 705 - Other - as specified
Due 9 September 2015
Resolved 17 December 2015
Resolution: Received proof that the O/O purchased a new ring life buoy.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 26 August 2015
Resolved
Line on waterlights attached to Lifefloats need 18ft of line.
Action required: 705 - Other - as specified
Due 9 September 2015
Resolved 17 December 2015
Resolution: Received proof that the O/O purchased new line for the water lights / life floats.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 August 2015
Resolved
Replace expired aspirin and eyewash.
Action required: 705 - Other - as specified
Due 9 September 2015
Resolved 15 December 2015
Resolution: Received proof that the O/O purchased new aspirin and eye wash.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 26 August 2015
Resolved
Provide an updated list of covered employees for the drug and alcohol program.
Action required: 705 - Other - as specified
Due 9 September 2015
Resolved 7 January 2016
Resolution: Received an updated list of covered employees for the drug and alcohol program via fax.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 26 August 2015
Resolved
Provide MIS report for 2014 for the drug and alcohol program.
Action required: 705 - Other - as specified
Due 9 September 2015
Resolved 7 January 2016
Resolution: Received an 2014 MIS Report for the drug and alcohol program via fax.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 26 August 2015
Resolved
Tighten port shaft, has a constant leak.
Action required: 705 - Other - as specified
Due 2 September 2015
Resolved 28 August 2015
Electrical › Electric Supply System (service) › Battery Installation
Issued 1 June 2012
Resolved
There are too many wires connected to the positive terminal of the stbd battery bank. Additionally there is no over-current protection on the conductors. The loads need to be connected at the main disconnect switch or a sub panel disconnect w/ over-current protection sized to the wire & load.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 June 2012
Resolved 22 June 2012
Resolution: Corrected. Additional overcurrent protection added for pump.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 June 2012
Resolved
Lagging is missing from dry section of diesel exhaust pipes between manifold & cooling water injection port. Install effective lagging.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 June 2012
Resolved 22 June 2012
Resolution: Renewed & wired llaced in place.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 1 June 2012
Resolved
Exhaust pipe hanger for diesel generator wasted. Replace hanger.
Action required: 705 - Other - as specified
Due 29 June 2012
Resolved 22 June 2012
Resolution: Repaired.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 June 2012
Resolved
Stbd side light bulb not lighting. Relight / repair.
Action required: 705 - Other - as specified
Resolved 1 June 2012
Resolution: New bulb installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 June 2012
Resolved
Anchor light not lighting.
Action required: 705 - Other - as specified
Resolved 1 June 2012
Resolution: Wiring splice at fixture found loose. Trimmed to good wire & spliced w/ crimp connectors then taped. Lamp left watching properly.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 23 August 2011
Resolved
Child PFD storage marked w/ "5" and should be "6".
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2011
Resolved 26 August 2011
Resolution: Signage corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 August 2011
Resolved
Replace out dated aspirin, eyewash & ammonia inhalants.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2011
Resolved 23 August 2011
Resolution: Corrected date of inspection.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 June 2009
Resolved
Renew life line around R/B & 60' line.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2009
Resolved 21 June 2009
Resolution: Corrected. Master has 500'' spool of line and was in process of renewal this inspection. Telcon 6.18.09 confirmed completion of work.
Lifesaving › Lifefloat › Pendant
Issued 19 June 2009
Resolved
Replace pendants on all L/Fs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2009
Resolved 21 June 2009
Resolution: Corrected. Master has 500'' spool of line and was in process of renewal this inspection. Telcon 6.18.09 confirmed completion of work.
Construction/Loadline › Hull › Keel
Issued 4 May 2009
Resolved
Crop to good wood and renew rotted section of stem.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 14 May 2009
Resolution: Inner & outer stem R&R. Inner stem renewed from top down to 2'' above LWL. Outer stem renewed to LWL.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 May 2009
Resolved
Complete sealing of the collision bhd; a) wire penetration for bilge alarm loose packing. // b) caulk & batten IWO the chine to close the gaps. // c) caulk & close gaps IWO bottom longitudinals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 14 May 2009
Resolution: Completed.
Construction/Loadline › Hull › Side Shell
Issued 4 May 2009
Resolved
Renew rotted and worn planking of the fwd bulwarks.
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 14 May 2009
Resolution: New bulwark frames added port & stbd bow and associated side shell planking renewed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 May 2009
Resolved
Refasten non-watertight bhd fwd of collision bhd.
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 14 May 2009
Resolution: Completed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 May 2009
Resolved
Caulk bhd forward of engines.
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 14 May 2009
Resolution: Completed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 May 2009
Resolved
Replace missing handle on battery switch.
Due 5 June 2009
Resolved 16 June 2009
Resolution: Switch renewed in kind.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 4 May 2009
Resolved
Provide securing device for the MSD overboard discharge to lockout valve in closed position.
Due 31 May 2009
Resolved 14 May 2009
Resolution: Cable lock.
Construction/Loadline › Hull › Bottom Plating
Issued 4 May 2009
Resolved
Pull fasteners for exam.
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 7 May 2009
Resolution: Approximately 30 pulled & examined. Master continued pulling until he renewed approximately 300. Of the 30 examine only one was marginal.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 4 May 2009
Resolved
Renew stern bearing.
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 14 May 2009
Resolution: Renewed.
Lifesaving › Hand Flares › Expired
Issued 4 May 2009
Resolved
Provide 4 additional hand distress flares. Vessel restricted to Rivers route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2009
Resolved 19 June 2009
Resolution: Corrected date of inspection.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 May 2009
Resolved
Replace 10 adult PFDs. Internal retainer for strap found rotted thus allowing waist strap to tear loose.
Condition: Unknown
Due 19 June 2009
Resolved 19 June 2009
Resolution: Replaced date of exam
Documentation › Certificates/Documents › Stability Letter
Issued 11 February 2008
Resolved
conduct stability test
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2009
Resolved 13 January 2009
Resolution: Stability test conducted. Stability letter issued.
Documentation › Certificates/Documents › FCC SSL
Issued 30 May 2007
Resolved
provide copy of FCC station license to Coast Guard.
Due 7 June 2007
Resolved 12 June 2007
Resolution: provided copy of FCC station license to Coast Guard.
Documentation › Markings/Placards › Lifejacket Placard
Issued 30 May 2007
Resolved
Provide proper donning placard for Type I horsecollar style PFD's
Due 7 June 2007
Resolved 12 June 2007
Resolution: Provided and posted proper donning placard for Type I horsecollar style PFD''s.
Lifesaving › Lifefloat › Markings
Issued 30 May 2007
Resolved
Restensil lifefloats and paddles.
Due 7 June 2007
Resolved 12 June 2007
Resolution: Restensiled lifefloats and paddles.
Lifesaving › Lifefloat › Lifeline
Issued 30 May 2007
Resolved
Provide new grablines on topside lifefloat to replace worn lines.
Due 7 June 2007
Resolved 12 June 2007
Resolution: Provided new grablines on topside lifefloat to replace worn lines.
Lifesaving › Lifefloat › Paddle
Issued 30 May 2007
Resolved
Provide replacement for broken paddle on starboard lifefloat on main deck, and provide 1 more paddle for port side lifefloat.
Due 7 June 2007
Resolved 12 June 2007
Resolution: Provided replacement for broken paddle on starboard lifefloat on main deck, and provided 1 more paddle for port side lifefloat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 May 2007
Resolved
Provide new items in first aid kit for all expired meds.
Due 7 June 2007
Resolved 12 June 2007
Resolution: Provided new items in first aid kit for all expired meds.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 30 May 2007
Resolved
Label emergengy escape hatch both inside and out in storage area.
Due 7 June 2007
Resolved 12 June 2007
Resolution: Labeled emergengy escape hatch both inside and out in storage area.
Lifesaving › Lifefloat › Float-free Link
Issued 13 July 2006
Resolved
Repair weak-link installation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2006
Resolved 3 August 2006
Resolution: Received faxed letter attesting to the correction of this item.
Construction/Loadline › Structures › Scuttle
Issued 13 July 2006
Resolved
Repair fwd hatch (emergency exit).
Condition: Improper/Lack of Maintenance
Due 1 August 2006
Resolved 3 August 2006
Resolution: Received faxed letter attesting to the correction of this item.
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 July 2006
Resolved
Conduct Man OVBD and Fire drill with crew.
Condition: Unknown
Due 1 August 2006
Resolved 3 August 2006
Resolution: Received faxed letter attesting to the correction of this item.
Construction/Loadline › Structures › Scuttle
Issued 13 July 2006
Resolved
Label emergency escape.
Condition: Improper/Lack of Maintenance
Due 1 August 2006
Resolved 3 August 2006
Resolution: Received faxed letter attesting to the correction of this item.
Communications › Audible Communications › Bell
Issued 13 July 2006
Resolved
Repair public address system
Condition: Placed in Improper Service
Due 1 August 2006
Resolved 3 August 2006
Resolution: Received faxed letter attesting to the correction of this item.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 13 July 2006
Resolved
Repair bridge window at next dry-dock
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 3 August 2006
Resolution: Received faxed letter attesting to the correction of this item.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 July 2005
Resolved
PROVE PROPER OPERATION OF EPIRB FLASHINF LIGHT. RESTRICTED TO 3 MILES FROM SHORE.
Due 10 August 2005
Resolved 3 August 2005
Resolution: SENT IN RECEIPT OF PURCHASE OF NEW EPIRB.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 July 2005
Resolved
PROVIDE PROOF EPIRB HAS A VALID REGISTRATION WITH NOAA. UNTIL COMPLETE VESSEL IS RESTRICTED TO 3 MILES FROM SHORE.
Due 10 August 2005
Resolved 1 August 2005
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 28 July 2005
Resolved
PROVIDE PROOF OF SAFETY RADIOTELEPHONY CERT, ISSUED BY FCC LICENSED INDIVIDUAL. RESTRICTED TO 1000FT FROM SHIRE UNTIL COMPLETE.
Due 10 August 2005
Resolved 3 August 2005
Lifesaving › Hand Flares › Quantity
Issued 28 July 2005
Resolved
PROVIDE 6 HAND FLARES AND 6 SMOKE FLARES. RESTRICTED TO 3 MILES FROM SHORE UNTIL COMPLETED.
Due 10 August 2005
Resolved 3 August 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 July 2005
Resolved
PROVIDE FIRST AID KIT IAW 46 CFR 160.041.
Due 10 August 2005
Resolved 3 August 2005
Lifesaving › Lifefloat › Paddle
Issued 28 July 2005
Resolved
ATTACH PADDLES TO LF.
Due 10 August 2005
Resolved 3 August 2005
Construction/Loadline › Structures › Deck Plating
Issued 28 July 2005
Resolved
CROP AND RENEW DECK NEAR STBD FORWARD MOORING POST. DECK WAS ROTTED FROM BELOW AND FIBERGLASS ON DECK WAS NOT SUPPORTIVE OF WEIGHT.
Due 10 August 2005
Resolved 29 August 2005
Resolution: Phoned in.
Documentation › Logs/Records › Drug Test Records
Issued 28 July 2005
Resolved
PROVIDE UP TO DATE LIST OF PERSONNEL ON DRUG CONSROTIUM.
Due 10 August 2005
Resolved 9 September 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 28 July 2005
Resolved
PROVIDE PANEL ON GAP ON DISTRIBUTION PANEL IN E/R.
Due 10 August 2005
Resolved 8 September 2005
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 July 2005
Resolved
TEST AND LOG EBIRB MONTHLY.
Due 10 August 2005
Resolved 29 August 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 28 July 2005
Resolved
LOG FIREFIGHTING CHECKS AND REQUIRED DRILLS.
Due 10 August 2005
Resolved 29 August 2005
Resolution: Phoned in.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 28 July 2005
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Due 10 August 2005
Resolved 3 August 2005
Construction/Loadline › Structures › Superstructure
Issued 28 July 2005
Resolved
REPAIR/REPLACE WINDOW IN PASSENGER AREA.
Due 10 August 2005
Resolved 3 August 2005
Lifesaving › Lifefloat › Paddle
Issued 28 July 2005
Resolved
PROVIDE PADDLE FOR LF.
Due 10 August 2005
Resolved 29 August 2005
Resolution: Phoned in.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 28 July 2005
Resolved
RE RETRO 6 LIFE JACKETS.
Due 10 August 2005
Resolved 29 August 2005
Resolution: Phoned in.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 16 July 2004
Resolved
Double hose clamp raw water intake for toilet.
Due 1 August 2004
Resolved 3 August 2004
Resolution: Per faxed ltr from O/O.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 July 2004
Resolved
Bond port side fuel fills to tanks.
Due 1 August 2004
Resolved 3 August 2004
Resolution: Per faxed ltr from O/O.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 July 2004
Resolved
Call immediately to re-schedule inspection. vessel is not authorized to carry passengers after 17 July 2004 unless inspected prior.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2004
Resolved 15 July 2004
Resolution: O/O rescheduled inspection, inspection commenced on 15 July 04 and was completed on 16 July 04.
Lifesaving › Lifefloat › Float-free Link
Issued 14 July 2004
Resolved
Correct the following for lifefloats:
a. Replace line between floorboard and lifefloat on upper lifefloat.
b. Provide two paddles for upper lifefloat.
c. Provide new weak link of correct capacity for forward lifefloats.
d. Secure weak link to vessel forward lifefloats.
e. Secure painter to lifefloats (forward)
f. Tie forward lifefloats together.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Resolution: Per attending marine inspector, [name withheld].
Lifesaving › Lifefloat › Retroreflective Material
Issued 14 July 2004
Resolved
Correct the following for lifefloats (continued):
g. Provide new reflective tape for forward lifefloats.
h. Secure floorboard to netting on forward starboard lifefloat.
i. Provide waterlight for port forward lifefloat.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Resolution: Per attending marine inspector, [name withheld].
Communications › Radio Communications › EPIRB
Issued 14 July 2004
Resolved
Mount EPIRB in float free location.
Due 16 July 2004
Resolved 16 July 2004
Resolution: Per attending marine inspector, [name withheld].
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 July 2004
Resolved
Conduct and log emergency drills with all crewmembers.
Due 16 July 2004
Resolved 16 July 2004
Resolution: Per attending marine inspector, [name withheld].
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 14 July 2004
Resolved
Provide proof of enrollment in a DOT approved drug testing program.
Condition: Unknown
Due 16 July 2004
Resolved 16 July 2004
Resolution: Per attending marine inspector, [name withheld].
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 July 2004
Resolved
Provide tide tables, coast pilot, light list.
Due 16 July 2004
Resolved 16 July 2004
Resolution: Per attending marine inspector, [name withheld].
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 14 July 2004
Resolved
Provide valid radio operator's permit.
Due 15 August 2004
Resolved 3 August 2004
Resolution: Per faxed ltr from O/O.
Documentation › Logs/Records › Logbook (official)
Issued 14 July 2004
Resolved
Log monthly EPIRB tests.
Due 16 July 2004
Resolved 16 July 2004
Resolution: Per attending marine inspector, [name withheld].
Documentation › Markings/Placards › Warning Signs
Issued 14 July 2004
Resolved
Provide emergency broadcast placard.
Due 16 July 2004
Resolved 16 July 2004
Resolution: Per attending marine inspector, [name withheld].
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 July 2004
Resolved
Provide aspirin for first aid kit.
Due 1 August 2004
Resolved 3 August 2004
Resolution: Per faxed ltr from O/O.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 July 2004
Resolved
Repair bracket for lifering waterlight.
Due 1 August 2004
Resolved 3 August 2004
Resolution: Per faxed ltr from O/O.
Construction/Loadline › Structures › Superstructure
Issued 14 July 2004
Resolved
Crop/renew rotted wood aft of main cabin port side overhead.
Due 15 August 2004
Resolved 3 August 2004
Resolution: Per faxed ltr from O/O.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 July 2004
Resolved
Schedule continuation of this inspection with vessel's Captain and regular deckhand- be prepared to get underway and conduct emergency drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Resolution: Per attending marine inspector, [name withheld].
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 July 2004
Resolved
Cover genset battery.
Due 1 August 2004
Resolved 3 August 2004
Resolution: Per faxed ltr from O/O.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 July 2004
Resolved
Double hose clamp genset raw water intake.
Due 1 August 2004
Resolved 3 August 2004
Resolution: Per faxed ltr from O/O.
Lifesaving › Lifejacket/PFD (Type I)
Issued 17 April 2002
Resolved
2 ADULT LIFE JACKETS BAD STRAPS. REPAIR/RENEW. MAX PERSONS REDUCED TO 47 UNTIL CORRECTED LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 13 May 2002
Resolution: NEW JACKETS ONBOARD
Construction/Loadline › Hull
Issued 17 April 2002
Resolved
FWD STBD TOP 2 PLANKS CRACKED. REPAIR/RENEW BOTH PLANKS NEXT DRYDOCK. TEMP REPAIR MADE WITH BACKING BLOCK. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 7 May 2003
Resolution: Item was not required to be done at this time. Location and repair appear to be sat for its route.
Construction/Loadline › Hull › Bottom Plating
Issued 17 April 2002
Resolved
8 PLANKS AFT OF FWD BLK IN 2ND COMPARTMENT LEAKS AT CHINE WHILE UNDERWAY. REPAIR/RENEW
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2002
Resolved 13 May 2002
Resolution: AREA RECAULKED.
Construction/Loadline › Hull › Bottom Plating
Issued 17 April 2002
Resolved
1ST PLANK ABOVE CHINE PORT SIDE BETWEEN 4TH & 5TH FRAME LEAKS. REPAIR/RENEW
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2002
Resolved 13 May 2002
Resolution: AREA RECAULKED
Navigation
Issued 29 May 2001
Resolved
STBD RUNNING LIGHT INOP. REPAIR/RENEW. VSL RESTRICTED TO DAYLIGHT/GOOD VISIBILITY OPS UNTIL CORRECTED.
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Lifesaving
Issued 29 May 2001
Resolved
WATER LIGHT NOT ATTACHED TO RING BUOY. REPAIR/RENEW
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Lifesaving
Issued 29 May 2001
Resolved
MAKE VSL AVAILABLE FOR UNDERWAY INSPECTION.
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Documentation
Issued 29 May 2001
Resolved
PROVIDE DRUG INFO REQUIRED ON AUDITH SHEET.
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Construction/Loadline
Issued 30 April 2001
Resolved
INSTALL A HIGH LEVEL ALARM FOR THE FWD COMPT.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Electrical
Issued 30 April 2001
Resolved
INSTALL A MAIN DISCONNECT SWITCH FOR THE AUX GENSET STARTING BATTERY.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Fire Fighting
Issued 10 May 1999
Resolved
CONDUCT INSTALLATION INSPECTION AND TEST OF FIXED CO2/FIRE DETECTION SYSTEM/PIPING.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 29 April 1999
Resolved
EITHER PULL FASTENERS FROM HULL IWO E/R AFT OR REFASTEN SAME AREA.
Condition: Unknown
Due 30 April 1999
Resolved 30 April 1999
Construction/Loadline
Issued 29 April 1999
Resolved
REMOVE RUDDER MOUNTS/ETC AND MAKE AVAILABLE FOR INSPECTION THE RUDDER BACKING BLOCKS.
Condition: Unknown
Due 30 April 1999
Resolved 30 April 1999
Lifesaving
Issued 10 March 1999
Resolved
MOUNT WATERLIGHTS IWO L/Fs AND RING BUOY.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Fire Fighting
Issued 10 March 1999
Resolved
RENEW/PROVIDE 6 YR SERVICE ON B-I EXTINGUISHER. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Electrical
Issued 10 March 1999
Resolved
PROPERLY WIRE/REMOVE RADIO IN FWD PASSENGER CABIN.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Engineering
Issued 10 March 1999
Resolved
DOUBLE CLAMP ALL EXHAUST FITTINGS.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Electrical
Issued 10 March 1999
Resolved
REMOVE ALL DEAD ENDED WIRING AND UNUSED BREAKER BOXES/FUSE BOXES IN E/R.
Condition: Unknown
Due 17 March 1999
Resolved 17 March 1999
Lifesaving
Issued 30 April 1998
Resolved
PROVIDE 1 NEW ORANGE LIFE RING WITH RETRO TAPE AND STENCIL. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 14 May 1998
Resolved 27 June 1998
Engineering
Issued 30 April 1998
Resolved
LABEL ALL FUEL SHUTOFFS.
Condition: Unknown
Due 14 May 1998
Resolved 27 June 1998
Lifesaving
Issued 30 April 1998
Resolved
INSTALL RETRO TAPE AND STENCILS ON ALL LIFE FLOATS.
Condition: Unknown
Due 14 May 1998
Resolved 27 June 1998
Construction/Loadline
Issued 16 May 1997
Resolved
SUBMIT REPAIR PROPOSAL FOR REPAIR OF OVERHEAD IN CRASH COMPARTMENT AROUND HATCH AND OUT BOTH SIDES TO RAILINGS.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Lifesaving
Issued 16 May 1997
Resolved
PROVIDE 2 ADULT PFDS. VESSELS TOTAL CARRYING CAPACITY REDUCED TO 49 UNTIL CLEARED.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Construction/Loadline
Issued 16 May 1997
Resolved
REPAIR/REPLACE BALL VALVES AS NOTED.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Electrical
Issued 16 May 1997
Resolved
PROVIDE AND INSTALL BATTERY BOX COVERS.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Construction/Loadline
Issued 16 May 1997
Resolved
INSTALL GRAVING PIECE IN AREA OF KEELSON (MIDSHIPS) TAHT IS SPLIT. CALL MARINE INSPECTOR FOR INSPECTION PRIOR TO REFLOATING VESSEL.
Condition: Unknown
Due 16 May 1997
Resolved 16 May 1997
Construction/Loadline
Issued 24 March 1993
Resolved
REPLACE PLANKING IN WAY OF BOTH PORT AND STBD FUEL TANK VENTS. PLANKING MUST SPAN TWO (02) FRAME SPACES, APPROX. 5 (FIVE) FT. LENGTH. CREDIT FOR DRYDOCK TO BE GIVEN UPON COMPLETION OF THIS REQ. THIS REQ. TO BE COMPLETEDTO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Navigation
Issued 3 April 1989
Resolved
REPLACE WITH 2 MILE RANGE CG APPROVED RUNNING LIGHTS AND STERN LIGHTS.
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Accommodation/Occupational Safety
Issued 9 November 1988
Resolved
MAKE PERMANENT THE CONNECTIONS OF BOTH HEADS TO ELECTRICSAN.
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Engineering
Issued 9 November 1988
Resolved
REPLACE THROUGH HULL FITTING FOR BILGE DISCHARGE IN AFT COMP'T. STARBOARD SIDE.
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Fire Fighting
Issued 9 November 1988
Resolved
REPLACE BOTH 1" GATE VALVES FOR GENERATOR COOLING INTAKE AND WASHDOWN/FIRE PUMP.
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Engineering
Issued 6 April 1988
Resolved
DOUBLE CLAMP ALL FLEXIBLE HOSE TO PIPING CONNECTIONS IN THE ENGINE ROOM.
Condition: Unknown
Due 6 April 1988
Resolved 6 April 1988
Navigation
Issued 6 April 1988
Resolved
OBTAIN THE CURRENT EDITION OF LOCAL CHARTS, TIDE TABLES, COAST PILOT OR LIGHT LIST.
Condition: Unknown
Due 6 April 1988
Resolved 6 April 1988
Electrical
Issued 6 April 1988
Resolved
INSTALL PROTECTIVE GUARD ON GENERATOR ROTATING BELT.
Condition: Unknown
Due 6 April 1988
Resolved 6 April 1988
Lifesaving
Issued 6 April 1988
Resolved
POST EMERGENCY CHECK OFF & LIFE PRESERVER DONNING INSTRUCTIONS.
Condition: Unknown
Due 6 April 1988
Resolved 6 April 1988
Fire Fighting
Issued 24 March 1987
Resolved
PROVIDE NOZZLE FOR FIRE HOSES.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Accommodation/Occupational Safety
Issued 24 March 1987
Resolved
PROVIDE VENTILATION TO BOTTOM OF MACHINERY SPACE.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Engineering
Issued 24 March 1987
Resolved
SUBMIT PLANS OF AUTOMATIC BILGE PUMP INSTALLATION TO MIO, NY PLAN REVIEW OFFICE.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Engineering
Issued 24 March 1987
Resolved
INSTALL CHECK VALVES IN ALL BILGE PIPING SYSTEMS.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Engineering
Issued 24 March 1987
Resolved
PROVIDE INDICATORS IN PILOTHOUSE TO INDICATE AUTOMATIC BILGE PUMP OPERATION.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Fire Fighting
Issued 24 March 1987
Resolved
MOUNT PORTABLE B-I FIRE EXTINGUISHER IN PILOTHOUSE.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987