MAURY USCG vessel records Sign in
← All vessels

NICHOLAS L

NICHOLAS L is a 1975 offshore supply vessel. The Coast Guard has recorded 97 inspections since 1982, most recently in January 2026, along with 147 deficiencies, 2 operational controls and 6 casualty investigations between 1998 and 2013.

Records from 1982 to 2026. Most recent: inspection, 15 January 2026.

Built
1975
Last inspected
15 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE7436
Flag
UNITED STATES
367393270
Maury page id
psix-48285

Inspections, by type

…with no type recorded11
Years with a record 41 calendar years (1982–2026)
The 97 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)100.0 ft × 21.7 ft × 6.5 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · CROWN POINT LA, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 April 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE7436MMSI 367393270 · active · compulsorily equipped · granted 14 November 2018, expires 31 January 2029
WCZ7231MMSI not assigned · expired · voluntarily equipped · granted 23 March 2000, cancelled 29 May 2010
WAO2815MMSI 366208280 · cancelled · compulsorily equipped · granted 25 June 1996, cancelled 21 August 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PETER MAC Offshore Supply Vessel · MISLE 48166 · 20 December 2011 · activity 4217675ELMER M Towing Vessel · MISLE 116871 · 20 December 2011 · activity 4217675USCGC GEORGE COBB (WLM 564) DUPLICATE- DO NOT USE Public Vessel, Unclassified · MISLE 749493 · 20 December 2011 · activity 4217675MALLARD Unclassified · MISLE 475343 · 14 January 1998 · activity 188356

Inspection history · 97

15 January 2026 Annual Inspection · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8293912
5 February 2025 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8067172
11 June 2024 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7851206
5 March 2024 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7867869
1 May 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7643961
27 December 2022 Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7613462
5 October 2022 Construction Oversight · Examination of Repairs
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7567184
13 September 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7554215
22 June 2022 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7481828
23 March 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7402303
12 October 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7329267
14 April 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7174975
19 August 2020 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7048573
28 July 2020 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7015135
27 February 2020 Administrative Inspection · COI Inspection · Internal Structural Exam · Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6914829
17 October 2019 Deadweight Survey · Inclining Experiment
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6836916
23 April 2019 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6666182
10 April 2019 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6638100
17 July 2018 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6478107
28 March 2018 Annual Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6363399
13 April 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6104623
20 July 2016 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5947633
15 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5829448
18 August 2015 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5221150
2 July 2012 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4364535
5 June 2012 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4295045
20 December 2011 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4217675
20 December 2011 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4217760
18 February 2011 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3962172
12 March 2010 DAPI Audit · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3673502
11 May 2009 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3470467
13 February 2009 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3419117
14 January 2009 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3394290
5 September 2008 Examination of Repairs
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3321843
3 September 2008 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3317336
3 June 2008 Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3225534
19 July 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3000501
28 June 2007 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2952661
5 October 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2794696
18 August 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2752072
26 June 2006 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2689307
26 June 2006 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2751218
26 May 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2659681
18 May 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2602571
29 June 2005 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2408298
23 July 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2142650
15 March 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2024681
6 February 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2001919
10 March 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1754121
30 July 2002 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1654553
24 July 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1648927
2 May 2002 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1611997
11 April 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1603642
6 June 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382284
13 March 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1386733
6 January 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450420
27 September 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036291
16 October 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388632
6 March 1998 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1118794
29 January 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1110322
16 January 1998 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381121
14 January 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 188356
11 September 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785837
19 August 1997 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438626
22 January 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406034
19 January 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1367609
11 September 1995 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1190898
16 June 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1400193
12 March 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 178139
23 January 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1358648
22 February 1994 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 854591
1 February 1994 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1162265
26 January 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 851843
30 June 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1463781
10 June 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 643645
22 May 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 76400
24 February 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1146105
29 January 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 829920
25 February 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1393847
25 July 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1252834
4 March 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 931794
26 February 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1236080
14 March 1990 Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1228957
24 April 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1209161
14 March 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 895659
5 October 1988 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1194776
22 September 1988 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1196076
14 March 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1337215
3 March 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1029677
3 March 1987 COI Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1005575
3 March 1986 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1300238
30 September 1985 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 992481
17 September 1985 Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 994497
30 August 1985 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1294580
1 May 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1289150
26 February 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 979100
2 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970002

Deficiency record · 147

01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 September 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2022
Resolution: Vessel provided replacement master.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 September 2022 Resolved
A hinged watertight bulkhead door must be fitted with a quick action closing devise operable from both sides of the door and indicator lights at the operating station showing whether the door is open or closed. Indicator light switches on watertight doors between the galley and berthing area and between the lounge and engine room were found disabled using duct tape. Vessel removed disabling devices and tested alarms and indicators. Deficiency cleared prior to getting underway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2022
Resolved 13 September 2022
Resolution: Vessel removed disabling devices.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 September 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Vessel's masthead light was inoperable. Vessel is restricted from operating at night, including 1/2 hour after sunrise and 1/2 hour before sunset, and in times of reduced visibility until repaired.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 September 2022
Resolution: Vessel replaced masthead light including housing.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 13 September 2022 Resolved
After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's stability letter. Vessel's stability letter issued 04MAY2020 requires that "The vessel’s bilges and voids shall be kept pumped to minimum content at all times consistent with pollution prevention requirements." The lazarette and the bilge below the staterooms were found with excess water. Remove water.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2022
Resolved 13 September 2022
Resolution: Vessel removed water.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 September 2022 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 as amended here: (ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. No record of monthly inspections was available. Vessel conducted and logged monthly inspections during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 September 2022
Resolution: Vessel completed during inspection.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 March 2022 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Vessel does not have public address speakers in the galley, bunk rooms or lower passenger salon and the public address is not audible in these spaces. Provide a public address system audible in all required spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 12 April 2022
Resolution: Vessel added speakers in required spaces.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 March 2022 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Neither DSC VHF radio installed are provisioned with GPS input. Provide GPS input for all DSC radios.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 12 April 2022
Resolution: Vessel provided GPS input.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 March 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel did not have current paper charts and electronic plotting system had charts dated 2007. Provide current navigation charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 12 April 2022
Resolution: Vessel provided new electronic charts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 March 2022 Resolved
Except when individual pumps are provided for separate spaces, individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line. A stop-check valve located at a control point or manifold will meet the requirements for both a stop valve and a check valve. Lazarette aft pickup isolating valve handle broken. Repair and demonstrate proper operation of valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 12 April 2022
Resolution: Vessel replaced valve.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 April 2021 Resolved
PENETRATIONS AND OPENINGS IN WATERTIGHT BULKHEADS MUST-HAVE MEANS TO MAKE THEM WATERTIGHT. MARINE INSPECTOR DISCOVERED TWO BULKHEAD PENETRATIONS FROM ENGINE ROOM TO ACCOMODATION SPACE. VESSEL WILL NEED TO BLANK OFF PENETRATIONS TO THE SATISFACTION OF THE MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 14 April 2021
Resolution: vessel provided blanks blocking off old conduit penetrations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 April 2021 Resolved
THE INTENT OF THIS PART IS TO INSURE THAT THE SCANTLINGS, MATERIAL, FASTENINGS, WORKMANSHIP AND ARRANGEMENT OF EACH VESSEL ARE SUCH AS TO PROVIDE FOR SAFE OPERATION IN ACCORDANCE WITH THE TERMS OF ITS CERTIFICATE OF INSPECTION. MARINE INSPECTOR DISCOVERED CLAD WELDING ON STBD QUARTER WELL ABOVE WATER LINE. VESSEL IS TO CROP AND RENEW AREA AT NEXT SCHEDULED DRY DOCK. ADDITIONALLY, FRAMES 6 AND 7 IN THE LAZARETTE ON STBD SIDE FORM CENTERLINE SHOWED CRACKED WELDS. FRAMES TO BE REPAIRED AT NEXT SCHEDULED DRYDOCK.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2022
Resolved 22 June 2022
Resolution: Vessel made repairs that were found satisfactory to attending Marine Inspector. See photos attached to documentation section of activity #7481828
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 April 2021 Resolved
THE DISCHARGE ENDS OF FUEL TANK VENT PIPIES MUST BE FITTED WITH REMOVABLE FLAME SCREENS OR FLAME ARRESTORS. THE FLAME SCREENS MUST CONSIST OF A SINGLE SCREEN OF CORROSION RESISTANT WIRE OF AT LEAST 30 X 30 MESH. PORT AND STBD SIDE FUEL TANK VENTS WERE MISSING SCREENS. VESSEL WILL NEED TO REPLACE SCREENS TO SATISFACTION OF MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 14 April 2021
Resolution: Vessel provided 30X30 flame screens for fuel tank vents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 August 2020 Resolved
Vessel installed new engine control system. In accordance with CVC Policy 17-07, submit the following for review: (1) A limited QFA of the vessel’s propulsion engine control system (throttle), documenting system compliance to CVC Policy 17-07. The limited QFA should only consider loss of power to the control system. (2) A propulsion control drawing should be submitted with an installation/operational test protocol. This test protocol is an abridged document intended to show compliance with 46 CFR.184.620.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2020
Resolved 27 August 2020
Resolution: The required information has been submitted and approved.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 3 March 2020 Resolved
Total personnel onboard is limited to 50 until new stability letter is issued by MSC for incline performed on 19OCT19.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 July 2020
Resolution: New stability letter was issued to the vessel by MSC on 04MAY2020.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 February 2020 Resolved
At every inspection hazardous situations must be corrected. Repair through deck piping for port side fire main.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2020
Resolution: Throught deck fitting replaced and pressure tested, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2020 Resolved
Valves for removing water from diesel strainers must be provided with caps. Replace racor filters drains with metallic caps.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2020
Resolution: All racor drain caps replced with metallic plugs, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 February 2020 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Deficiencies 2-9 provide objective evidence that the vessel is substandard and not pro-actively managing technical and operational requirements. Vessel must complete a satisfactory COI re-inspection prior to any movement.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 March 2020
Resolution: Vessel cleared all open defs. Operational control removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 February 2020 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was missing 2 required life jackets, 4 were in a unserviceable condition, 2 had insufficient retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 February 2020
Resolution: Unserviceable lifejackets replaced, verifed all lifejackets IAW COI, all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 February 2020 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. High level float switch in sewage space was disconnected and the float switch in the main engine space was removed.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 February 2020
Resolution: ER alarms switch replaced and sewage alarms switch properly rewired. Conducted op test of both, all sat.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 27 February 2020 Resolved
When Class 1 doors are installed below a deck the molded line of which at its lowest point at side is less than 7ft above the deepest load line, an indicator light for each door which warns when the door is open must be installed on the bridge. Indicator light was found to non-operational.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 February 2020
Resolution: Switch adjusted, conducted op test, all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 February 2020 Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly. Crew was not testing monthly or logging appropriately.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 February 2020
Resolution: EPRIB tested and logged, operator gave crew training on requirement, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2020 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys. 1 life buoy was missing required plug and had deteriorated grab lines. Repair or provide replacement.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 February 2020
Resolution: Ring buoy replaced, all sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 27 February 2020 Resolved
Openings in watertight bulkheads must have mean of close it watertight. Forward Main Engine room bulkhead has open penetrations that are not watertight.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 February 2020
Resolution: Bulkhead penetrations sealed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 27 February 2020 Resolved
Training shall be conducted at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Crew had not been conducting training every 3 months or logging any training.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 February 2020
Resolution: Operator trained crew on required training intervals and documentation, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2020 Resolved
Safety relief valves for air service shall be provided with a substantial lifting device. Safety relief valves on both UPV's were missing lifting devices. Valves were replaced.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Valves replaced with new ASME UV valves at 125 psi, pop tested and hand lifted, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2020 Resolved
Waterlight not attached to ring bouy of STBD side.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Clip replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2020 Resolved
Relaced burst hoses on sewage piping behind false bulkead port side.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Hoses replaced and double clamped, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2020 Resolved
Install blanks on 02 open breakers on 110 panel aft passenger space.
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Blanks installed, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2020 Resolved
Replace plug on top J box and bottom of stair well.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Plug installed, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2020 Resolved
Fuel fill bonding strap unconnected on STBD fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Bonding strap reconnected, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 February 2020 Resolved
Vessel not logging draft readings / or documenting stability prior to vayages.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Operator trained crew on requirements, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 February 2020 Resolved
Lifejacket stowage not properly labeled in salon.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Labled IAW 185.516, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2020 Resolved
STBD MDE shaft seal was found to be leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Packing tightened, all sat.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 23 April 2019 Resolved
Vessel shall not carry more than 50 persons onboard per stability letter.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2019
Resolved 8 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 23 April 2019 Resolved
Repair salon sink water line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 May 2019
Resolution: Pipe repaired.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 23 April 2019 Resolved
Provide FCC operators permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 May 2019
Resolution: Permit provided.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 10 April 2019 Resolved
When the cognizant OCMI or the Commanding Officer, Marine Safety Center determines, in accordance with §178.210, that a vessel must have stability details indicated on its Certificate of Inspection or a stability letter, the owner or operator must submit the information listed in paragraph (b) of this section: Provide an approved stability letter noting stability details for a minimum of 50 passengers, 4 crew and cargo.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 3 March 2020
Resolution: Incline performed 19OCT19. New CG-835 restricting total personnel onboard to 50.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 10 April 2019 Resolved
Pursuant to 46 CFR 170.010, substitutions for calculations, information, or tests required in sub-chapter T may be approved by the Officer in Charge, Marine Inspection, if the substitution provides an equivalent level of safety. While the vessel is carrying more than 50 total persons the maximum cargo load must be reduced to no more than 15,000 lbs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 3 March 2020
Resolution: New CG-835 issued for updated stabiility.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 March 2018 Resolved
Destroy 1 adult lifejacket. The lifejacket was not servicable, but the vessel had extra on board.
Action required: 10 - Deficiency Rectified
Due 28 April 2018
Resolved 28 March 2018
Resolution: Corrected during inspection.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 April 2017 Resolved
Provide smoke detectors for all state rooms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 28 April 2017
Resolution: See Narrative.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 13 April 2017 Resolved
Replace rusty hose clamps and fittings on whet exhaust for Portside MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 28 April 2017
Resolution: See Narrative.
Engineering › Steering Gear System › Rudder Stock
Issued 13 April 2017 Resolved
Make repairs to steering gear to prevent excess water leaking when underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 28 April 2017
Resolution: See Narrative.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 April 2017 Resolved
Ensure all switchboards have covers at each breaker location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 28 April 2017
Resolution: See Narrative.
Construction/Loadline › Hull › Hull Plating
Issued 20 July 2016 Resolved
Clad weld 02 isolated pits in lower lounge as marked.
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Clad welds completed.
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 20 July 2016 Resolved
Replace gasket on aft WTD.
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Gasket replaced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 July 2016 Resolved
Cap unused penetration through stbd side of fwd watertight bulkhead in lower lounge.
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Bulkhead penetration capped.
Engineering › Bilge Water Management System › Piping
Issued 5 June 2012 Resolved
Foot valve for foward bilge suction foot valve broke off.
Action required: 705 - Other - as specified
Due 5 June 2012
Resolved 5 June 2012
Resolution: Replaced with connection and tested sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 5 June 2012 Resolved
Found several broken hose clamps on exhaust system
Action required: 705 - Other - as specified
Due 5 June 2012
Resolved 5 June 2012
Resolution: Replaced prior to inspectors departure.
Engineering › Compressed Air System (start air) › Valve
Issued 5 June 2012 Resolved
Found bad gauge on port air compressor.
Action required: 705 - Other - as specified
Due 5 June 2012
Resolved 5 June 2012
Resolution: Replaced prior to inspectors departure.
Documentation › Logs/Records › Drug Test Records
Issued 18 February 2011 Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25.
Due 20 March 2011
Resolved 28 February 2011
Resolution: DER provided DAPI with background check form being implemented for all future hires.
Documentation › Logs/Records › Drug Test Records
Issued 18 February 2011 Resolved
Alcohol testing devices not onboard as required by 46 CFR 4. Devices located onboard were expired.
Due 20 March 2011
Resolved 28 February 2011
Resolution: DER provided DAPI with invoice of new testing devices order.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 12 March 2010 Resolved
Provide in-line fuse for bridge battery
Action required: 705 - Other - as specified
Resolved 19 March 2010
Resolution: Fuses was installed
Communications › Radio Communications › EPIRB
Issued 12 March 2010 Resolved
Epirb registration is expired, renew
Action required: 705 - Other - as specified
Resolved 12 March 2010
Resolution: Epirb registration was renew during the inspection
Lifesaving › Hand Flares › Expired
Issued 12 March 2010 Resolved
All flares are expired, renew flares
Action required: 705 - Other - as specified
Resolved 12 March 2010
Resolution: Flares were renewed during the inspection
Engineering › Steering Gear System › Rudder Bearing
Issued 12 March 2010 Resolved
Repack starboard rudder packing and renew both port and starboard fanged bolts, bolts are too small for operation
Action required: 705 - Other - as specified
Resolved 19 March 2010
Resolution: New packing was installed and larger bolts were installed, tested satisfactory
Lifesaving › Inflatable Liferafts › Servicing
Issued 11 May 2009 Resolved
One life raft is currently being serviced at ICON. Vessel to provide 100% lifesaving equipment onboard vessel for total persons. Vessel is restricted to no more than 25 persons onboard including crew until life raft is returned to vessel. Must be completed by 11JUN09 and to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 11 June 2009
Resolved 13 May 2009
Resolution: [name withheld] faxed Certificate of LifeRaft Re-Inspection this date for 25 Person Life Raft Serial No. XDC1EE06C606.
Construction/Loadline › Hull › Side Shell
Issued 3 September 2008 Resolved
Provide permanent repairs to throuogh plate damage in engineroom stbd side fwd approx 26in above waterline and in laz stbd side fwd approx 34in above waterline. Vessel has effected temp repairs to both locations. Vsl is permitted to transit to Ventoura Harbor to effect permanent repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 September 2008
Resolved 5 September 2008
Engineering › Bilge Water Management System › Pump
Issued 10 June 2008 Resolved
Provide line diagram of the bilge and fire water system.
Action required: 705 - Other - as specified
Due 11 July 2008
Resolved 10 June 2008
Engineering › Bilge Water Management System › Valve
Issued 10 June 2008 Resolved
Label bilge manifold.
Action required: 705 - Other - as specified
Due 11 July 2008
Resolved 5 September 2008
Documentation › Certificates/Documents › FCC SSL
Issued 28 June 2007 Resolved
Provide renewed FCC Safety Certificate IAW 46 CFR 184.502
Action required: 705 - Other - as specified
Due 28 July 2007
Resolved 7 August 2007
Resolution: Vessel rep provided a valid FCC Safety Certificate which is posted on board the vessel.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 28 June 2007 Resolved
Mount Fire Extinguisher in Engine Room IAW 46 CFR 181.500
Action required: 705 - Other - as specified
Due 28 July 2007
Resolved 7 August 2007
Resolution: Fire extinguisher mounted securely in engine room.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 28 June 2007 Resolved
Provide 2 fire extinguishers IAW Current COI
Action required: 705 - Other - as specified
Due 28 July 2007
Resolved 19 July 2007
Resolution: Mounted 2 new fire extinguishers.
Electrical › Electrical Distribution System (service) › Cable
Issued 28 June 2007 Resolved
Ensure wiring in third void is installed IAW 46 CFR 183.340
Action required: 705 - Other - as specified
Due 28 July 2007
Resolved 19 July 2007
Resolution: Wiring properly installed.
Stability › Incline Test › General
Issued 18 August 2006 Resolved
Provide a stability review in accordance with USCG Marine Safety Technical Note 04-95 "Light Ship Change Determination" accounting for all changes, including tankage and generators, which have been made since the vessel's last stability test and lightships determination.
Action required: 705 - Other - as specified
Due 17 October 2006
Resolved 5 October 2006
Resolution: Received stability review calculations and their is no appreciable change that will affect the vessels stability.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 16 August 2006 Resolved
Permanent marking of name and hailing port on the aft section of the house.
Condition: Improper/Lack of Maintenance
Due 24 August 2006
Resolved 18 August 2006
Resolution: Vsl made permanent marking to house.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 16 August 2006 Resolved
Install metal supports to secure electrical wires and cables in the engine room.
Condition: Improper Installation
Due 24 August 2006
Resolved 18 August 2006
Resolution: Vsl installed metal supports in engineroom.
Engineering › Fuel Oil Service System › Hose
Issued 16 August 2006 Resolved
Replace cotton-jacketed fuel hoses on the supply side of the engines and at the fuel filters with SAE J1942 or equivalent.
Due 24 August 2006
Resolved 18 August 2006
Resolution: Vsl replaced fuel hoses.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 16 August 2006 Resolved
Install containment bowls on all fuel filter casings.
Condition: Improper/Lack of Maintenance
Due 24 August 2006
Resolved 19 August 2006
Resolution: Vsl installed containment bowls on fuel fiters.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 16 August 2006 Resolved
Resolve the misaligned throttle control issue for the port engine.
Due 24 August 2006
Resolved 18 August 2006
Resolution: Vsl had technical repair throttle control problem for all stations.
Fire Fighting › Ventilation Systems › Fans
Issued 16 August 2006 Resolved
Install port ventilation blower for engine room.
Condition: Improper Installation
Due 24 August 2006
Resolved 18 August 2006
Resolution: Vsl installed vent blower for engine room.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 16 August 2006 Resolved
Properly dispose bilge wastewater to landside.
Due 24 August 2006
Resolved 18 August 2006
Resolution: Vsl removed all bilge waste water.
Construction/Loadline › Structures › Scuttle
Issued 10 July 2006 Resolved
Replace forward scuttle
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2006
Resolution: Scuttle was renewed.
Construction/Loadline › Structures › Superstructure
Issued 10 July 2006 Resolved
Crop out deck area port side aft of house
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2006
Resolution: Deck area was repaired satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 10 July 2006 Resolved
Crop out and renew inset in conjunction with exhaust renewal. Repair is approximately 18 inch below exhaust on port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2006
Resolution: Port insert is satisfactory repaired.
Construction/Loadline › Hull › Hull Plating
Issued 10 July 2006 Resolved
Replace frames 1, 5, 7 and replace starboard stern plating in the same area of frames listed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2006
Resolution: Frames 1, 5, 7 and starboard stern plating in the same area of frames listed were repaired satisfactory.
Construction/Loadline › Penetrations › Weld
Issued 10 July 2006 Resolved
Repair cracks in weld in the stern portside in the area of frames 6 and 8.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2006
Resolution: Repair cracks in weld in the stern portside in the area of frames 6 and 8 were repaired.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 10 July 2006 Resolved
Replace worn cutlass bearings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2006
Resolution: Cutlass bearing were replaced.
Construction/Loadline › Penetrations › Weld
Issued 10 July 2006 Resolved
Repair hand rails and supports in the bow area and forward of the house.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2006
Resolution: Hand rails and supports in the bow area and forward of the house were repaired satisfactory.
Construction/Loadline › Hull › Hull Plating
Issued 10 July 2006 Resolved
Repair and renew bow stem and bow area. Replace area below main deck to bottom inset.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2006
Resolution: Bow stem and bow area. Replace area below main deck to bottom inset. This area has been repaired satisfactory.
Engineering › Bilge Water Management System › Hose
Issued 18 May 2006 Resolved
Renew non-metallic hoses for bilge pump driven off starboard main, between pump housing and metallic piping.
Action required: 705 - Other - as specified
Due 18 June 2006
Resolved 26 May 2006
Resolution: Installed CG approved non-metallic hose.
Fire Fighting › Ventilation Systems › Fans
Issued 18 May 2006 Resolved
Install cover for starboard ventilation fan in engine room.
Action required: 705 - Other - as specified
Due 18 June 2006
Resolved 26 May 2006
Resolution: Installed protective cover.
Lifesaving › Inflatable Liferafts › Servicing
Issued 18 May 2006 Resolved
Passenger count is reduced to 40 until liferaft servicing is complete and loaner 20 person raft is replaced by vessels regular 25 person raft.
Action required: 705 - Other - as specified
Due 18 June 2006
Resolved 26 May 2006
Resolution: Installed new 25 person inflatable liferaft.
Construction/Loadline › Structures › Superstructure
Issued 23 July 2004 Resolved
Repair cracks found in lower welds of frames 2 and 3 in the compartment below the galley.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2004
Resolved 29 July 2004
Resolution: Cracks repaired in lower welds of frames 2 and 3 and bracing arms installed for reinforcement.
Fire Fighting › Fire Pumps
Issued 11 April 2002 Resolved
Prove proper operation of the electric fire pump so that it maintains a minimum pressure of 60 psi at the pump outlet. LEGACY COMPONENT DESC: Pressure
Due 11 May 2002
Resolved 2 May 2002
Navigation › Piloting/Steering
Issued 11 April 2002 Resolved
Provide the following charts with corrections updated through the most recent NTM: 18749, 18740, 4802. LEGACY COMPONENT DESC: Marine Charts
Due 11 May 2002
Resolved 2 May 2002
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 11 April 2002 Resolved
Provide smoke detector in bunk room meeting UL Standard 217 and listed as "Single Station Smoke Detector - Also suitable for use in Recreational Vehicles.
Condition: Unknown
Due 11 May 2002
Resolved 2 May 2002
Engineering › Fuel Oil Service System
Issued 11 April 2002 Resolved
Install flame impingement bowl on center Raycor filter (aft of center main engine). LEGACY COMPONENT DESC: Filter
Condition: Unknown
Due 11 May 2002
Resolved 2 May 2002
Documentation
Issued 6 June 2001 Resolved
provide proof of FCC certificate.
Condition: Unknown
Due 18 July 2001
Resolved 18 July 2001
Documentation
Issued 6 June 2001 Resolved
Provide proof of Bridge log and EPIRB log.
Condition: Unknown
Due 18 July 2001
Resolved 18 July 2001
Documentation
Issued 6 June 2001 Resolved
Provide proof of drug testing program IAW 46 CFR subpart 16.
Condition: Unknown
Due 18 July 2001
Resolved 18 July 2001
Construction/Loadline
Issued 6 June 2001 Resolved
Provide proof of operation the WTD warning light located at the operating station for WTD between the engineroom and generator room.
Condition: Unknown
Due 18 July 2001
Resolved 18 July 2001
Fire Fighting
Issued 13 March 2000 Resolved
INSTALL PRESSURE GAUGES FOR BOTH FIRE PUMPS LOCATED IN ENGINE ROOM PRIOR TO20 MARCH 2000.
Condition: Unknown
Due 20 March 2000
Resolved 23 March 2000
Engineering
Issued 13 March 2000 Resolved
Provide and ensure proper pressure relief and set pressure vessel relief valves prior to 20 March 2000.
Condition: Unknown
Due 20 March 2000
Resolved 23 March 2000
Documentation
Issued 13 March 2000 Resolved
Provide drug and alcohol program for auditing prior to 15 MARCH 2000.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Documentation
Issued 13 March 2000 Resolved
PROVIDE FCC RADIO OPERATOR'S LICENSE PRIOR TO 15 MARCH 2000.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Documentation
Issued 13 March 2000 Resolved
PROVIDE FCC STATION LICENSE PRIOR TO 15 MARCH 2000
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Fire Fighting
Issued 13 March 2000 Resolved
PROVIDE/SHOW DISCHARGE GAUGE PRESSURE OF FIRE PUMPS NO LESS THAN 60 PSIAND 50 GPM PRIOR TO 20 MARCH 2000.
Condition: Unknown
Due 20 March 2000
Resolved 23 March 2000
Engineering
Issued 13 March 2000 Resolved
Provide double clamping to main engine raw water prior to 20 March 2000.
Condition: Unknown
Due 20 March 2000
Resolved 23 March 2000
Construction/Loadline
Issued 16 January 1998 Resolved
REPLACE THE MISSING WATERTIGHT HATCH COVER LEADING FROM THE FIRST TO SECONDDECK ACCOMMODATONS AREAS.
Condition: Unknown
Due 16 January 1998
Resolved 16 January 1998
Navigation
Issued 26 January 1994 Resolved
PROVIDE CORRECTED PUBLICATIONS(COAST PILOT & LIGHT LIST) OF LOCAL OPERATINGAREA.
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Documentation
Issued 26 January 1994 Resolved
PROVIDE INDIVIDUAL ON BOARD WHENEVER VESSEL OPERATES WHO POSSESS VALID MARINE RADIO OPERATORS PERMIT(M.R.O.P).
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Navigation
Issued 26 January 1994 Resolved
PROVIDE CORRECTED CHARTS OF LOCAL OPERATING AREA.
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Construction/Loadline
Issued 29 January 1993 Resolved
PROPERLY INSTALL DOOR OPEN INDICATORS IN PILOT HOUSE FOR (2) WATERTIGHT_x001C_ DOORS IN ENGINE ROOM.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Electrical
Issued 26 February 1991 Resolved
Properly support electrical wiring throughout vessel in accordance with IEEE-45
Condition: Unknown
Due 26 February 1991
Resolved 26 February 1991
Accommodation/Occupational Safety
Issued 26 February 1991 Resolved
Repair leaking refrigeration drain under galley, starboard side fourth frame bay aft of collision bulkhead.
Condition: Unknown
Due 26 February 1991
Resolved 26 February 1991
Accommodation/Occupational Safety
Issued 26 February 1991 Resolved
Repair leaking MSD holding tank.
Condition: Unknown
Due 26 February 1991
Resolved 26 February 1991
Accommodation/Occupational Safety
Issued 26 February 1991 Resolved
Properly support hot water heater.
Condition: Unknown
Due 26 February 1991
Resolved 26 February 1991
Accommodation/Occupational Safety
Issued 26 February 1991 Resolved
Properly support piping throughout vessel.
Condition: Unknown
Due 26 February 1991
Resolved 26 February 1991
Engineering
Issued 26 February 1991 Resolved
Repair leak in port main engine heat exchanger piping.
Condition: Unknown
Due 26 February 1991
Resolved 26 February 1991
Construction/Loadline
Issued 26 February 1991 Resolved
Repair stern rub rail where fractured.
Condition: Unknown
Due 26 February 1991
Resolved 26 February 1991
Electrical
Issued 26 February 1991 Resolved
Repair and prove proper operation of number one (01) generator overspeed trip.
Condition: Unknown
Due 26 February 1991
Resolved 26 February 1991
Engineering
Issued 26 February 1991 Resolved
Repair and prove proper operation of leaking number two (02) main engine gear box hydraulic pump.
Condition: Unknown
Due 26 February 1991
Resolved 26 February 1991
Fire Fighting
Issued 26 February 1991 Resolved
Hard pipe fire pump suction.
Condition: Unknown
Due 26 February 1991
Resolved 26 February 1991
Electrical
Issued 26 February 1991 Resolved
Properly block batteries in battery boxes.
Condition: Unknown
Due 26 February 1991
Resolved 26 February 1991
Electrical
Issued 14 March 1990 Resolved
REPAIR FRACTURED BATTERY BOX AND PROVIDE SPACERS IN BOX.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Engineering
Issued 14 March 1990 Resolved
PROVIDE METAL BOWLS FOR THREE RACOR FUEL FILTERS ON MAIN ENGINES.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Lifesaving
Issued 14 March 1990 Resolved
PROVIDE PROPER AMOUNT OF RETROREFLECTIVE TAPE ON BACK OF 5 ADULT LIFE JACKETS.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Electrical
Issued 14 March 1990 Resolved
PROVIDE CRIMP-ON CONNECTORS FOR ALL NAVIGATION LIGHT WIRING.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Electrical
Issued 14 March 1990 Resolved
PROVIDE PROPER METAL ELECTRICAL CABLE SUPPORTS AS REQUIRED BY IEEE STANDARD45. (5/8 INCH BANDS EVERY 18 INCHES ON HORIZONTAL RUNS AND EVERY 24 INCHESON VERTICAL RUNS)
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Accommodation/Occupational Safety
Issued 14 March 1990 Resolved
REPLACE RAILS ON AFT MAIN DECK PRIOR TO CARRYING PASSENGERS OUTSIDE OF CABIN.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Lifesaving
Issued 14 March 1990 Resolved
REPAIR WORN LINE ON RING BUOY OR REPLACE RING BUOY.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Lifesaving
Issued 14 March 1990 Resolved
REPLACE GRAB LINE ON STBD TOP LIFE FLOAT AND PROVIDE PROPER SIZE WEAK LINK AT PORT SIDE STACK OF TWO LIFE FLOATS.
Condition: Unknown
Due 14 March 1990
Resolved 14 March 1990
Lifesaving
Issued 14 March 1989 Resolved
PROVIDE TWO WEAK LINKS OF PROPER SIZE ON LIFE FLOATS PT AND STBD.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Documentation
Issued 14 March 1989 Resolved
PROVIDE EVIDENCE OF A VALID FCC STATION LICENSE ABOARD VESSEL.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Fire Fighting
Issued 14 March 1989 Resolved
RECHARGE ONE B-1 PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Engineering
Issued 14 March 1989 Resolved
REMOVE OILY WASTES FROM LAZARETTE BILGE.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Deck/Cargo
Issued 14 March 1989 Resolved
PROVIDE WARNING SIGNS FOR FLAMMABLE CARGO PER 49 CFR 176.325.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Fire Fighting
Issued 14 March 1989 Resolved
PROVIDE HAND PUMP.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Accommodation/Occupational Safety
Issued 3 March 1988 Resolved
STRAIGHTEN PORT ENGINEROOM VENT AND PROVIDE MEANS OF CLOSURE.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Construction/Loadline
Issued 3 March 1988 Resolved
AT STBD AFT CORNER WELD 5 CORNER BRACKETS, FAIR WRAPPER PLATE, INSERT 18X18 INCH MAIN DECK.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Construction/Loadline
Issued 3 March 1988 Resolved
VEE AND WELD 3RD BOTTOM LONG FROM STBD WHERE FRACTURED NEAR STERN AND WELD 5TH UNDERDECK LONG FROM STBD SIDE ABOUT 1 FOOT FROM TRANSOM.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Construction/Loadline
Issued 3 March 1988 Resolved
CROP AND INSERT PORT STERN WRAPPER PLATE FROM MAIN DECK DOWN @ 3 FEET X 2 FEET WIDE ALSO INSERT MAIN DECK 2X2 FEET SAME PLACE AND REPAIR ASSOCIATED INTERMALS.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Lifesaving
Issued 3 March 1988 Resolved
REPLACE 22 CHEMLIGHTS ON PFD'S; COMPLETE BEFORE NIGHTTIME OPERATION.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Engineering
Issued 3 March 1988 Resolved
REPAIR LEAKS IN PORT AND STBD MAIN ENGINE COOLING EXHAUST.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Accommodation/Occupational Safety
Issued 3 March 1988 Resolved
PROVIDE PRESSURE GAUGE FOR STBD AIR RECEIVER AND TEST RELIEF VALVE.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Fire Fighting
Issued 3 March 1988 Resolved
RENEW STBD FIRE STATION HANDLE.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Engineering
Issued 3 March 1988 Resolved
LABEL REACHROD FOR FOREPEAK BILGE VALVE.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Construction/Loadline
Issued 3 March 1988 Resolved
PLUG TWO BOLT HOLES IN MAIN DECK OVER ENGINEROOM.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Navigation
Issued 3 March 1988 Resolved
RENEW CENTER BULB IN PORT RUNNING LIGHT.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Engineering
Issued 3 March 1987 Resolved
TEST RUN ALL MAIN ENGINES AND TEST FIRE AND BILGE PUMP ON STBD MAIN ENGINE.
Condition: Unknown
Due 3 March 1987
Resolved 3 March 1987
Documentation
Issued 3 March 1987 Resolved
STENCIL WARNING SIGN ON AFT DECKHOUSE FOR CARRIAGE OF HAZARDOUS MATERIALS.
Condition: Unknown
Due 3 March 1987
Resolved 3 March 1987
Electrical
Issued 30 August 1985 Resolved
REMOVE UNUSED WIRES AND SECURE EXISTING WIRES IN A PROPER FASHION IN P&S SIDE VOID SPACES.
Condition: Unknown
Due 30 August 1985
Resolved 30 August 1985
Navigation
Issued 26 February 1985 Resolved
RENEW CENTER RAM PINS ON STEERING GEAR.
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985
Electrical
Issued 26 February 1985 Resolved
PROVE OPERATION OF EMERGENCY LIGHTS.
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985
Construction/Loadline
Issued 26 February 1985 Resolved
MAKE THE FOLLOWING PERMANENT REPAIRS (A) VEE OUT AND REWELD CRACKS IN #2 COMPT. #2&#3 WEB TO FRAME CONNECTION AT PORT SIDE (B) CROP OUT TO GOOD METAL AND RENEW #1 AND #2 PORT TRANSOM VERTICAL STIFFENERS AND #5 STBD UNDER DECK STIFFENER.
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985
Construction/Loadline
Issued 26 February 1985 Resolved
MAKE #2/#3 COMPARTMENT'S BULKHEAD WATERTIGHT. FILL UNUSED STUFFING TUBE HOLES.
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985
Lifesaving
Issued 26 February 1985 Resolved
PROVIDE 6 ORANGE DISTRESS SIGNALS.
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985

Casualty record · 6

14 January 1998Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 6 dead · 1 injured · activity 188356
8 June 2011Routine · role: Involved in a Marine Casualty · activity 4041492
20 December 2011Routine · role: Involved in a Marine Casualty · activity 4217675
3 June 2013Routine · role: Involved in a Marine Casualty · activity 4610859
25 July 2013Routine · role: Involved in a Marine Casualty · activity 4665605
14 August 2013Routine · role: Involved in a Marine Casualty · activity 4691451
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.