NICHOLAS L

NICHOLAS L is a 1975 offshore supply vessel. The Coast Guard has recorded 23 inspections since 2016, most recently in January 2026, along with 46 deficiencies, 2 operational controls and 6 casualty investigations between 1998 and 2013.

Records from 1998 to 2026. Most recent: inspection, 15 January 2026.

Built
1975
Last inspected
15 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 January 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE7436
Flag
UNITED STATES
Maury page id
psix-48285

Documentation record

Registered dimensions (L × B × D)100.0 ft × 21.7 ft × 6.5 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · CROWN POINT LA, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 April 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

15 January 2026 Annual Inspection · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8293912
5 February 2025 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8067172
11 June 2024 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7851206
5 March 2024 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7867869
1 May 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7643961
27 December 2022 Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7613462
5 October 2022 Construction Oversight · Examination of Repairs
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7567184
13 September 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7554215
22 June 2022 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7481828
23 March 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7402303
12 October 2021 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7329267
14 April 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7174975
19 August 2020 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7048573
28 July 2020 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7015135
27 February 2020 Administrative Inspection · COI Inspection · Internal Structural Exam · Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6914829
17 October 2019 Deadweight Survey · Inclining Experiment
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6836916
23 April 2019 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6666182
10 April 2019 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6638100
17 July 2018 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6478107
28 March 2018 Annual Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6363399
13 April 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6104623
20 July 2016 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5947633
15 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5829448

Deficiency record · 46

01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 13 September 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2022
Resolution: Vessel provided replacement master.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 September 2022 Resolved
A hinged watertight bulkhead door must be fitted with a quick action closing devise operable from both sides of the door and indicator lights at the operating station showing whether the door is open or closed. Indicator light switches on watertight doors between the galley and berthing area and between the lounge and engine room were found disabled using duct tape. Vessel removed disabling devices and tested alarms and indicators. Deficiency cleared prior to getting underway.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2022
Resolved 13 September 2022
Resolution: Vessel removed disabling devices.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 September 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. Vessel's masthead light was inoperable. Vessel is restricted from operating at night, including 1/2 hour after sunrise and 1/2 hour before sunset, and in times of reduced visibility until repaired.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 September 2022
Resolution: Vessel replaced masthead light including housing.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 13 September 2022 Resolved
After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's stability letter. Vessel's stability letter issued 04MAY2020 requires that "The vessel’s bilges and voids shall be kept pumped to minimum content at all times consistent with pollution prevention requirements." The lazarette and the bilge below the staterooms were found with excess water. Remove water.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2022
Resolved 13 September 2022
Resolution: Vessel removed water.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 September 2022 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 as amended here: (ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. No record of monthly inspections was available. Vessel conducted and logged monthly inspections during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 September 2022
Resolution: Vessel completed during inspection.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 March 2022 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Vessel does not have public address speakers in the galley, bunk rooms or lower passenger salon and the public address is not audible in these spaces. Provide a public address system audible in all required spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 12 April 2022
Resolution: Vessel added speakers in required spaces.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 March 2022 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Neither DSC VHF radio installed are provisioned with GPS input. Provide GPS input for all DSC radios.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 12 April 2022
Resolution: Vessel provided GPS input.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 March 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel did not have current paper charts and electronic plotting system had charts dated 2007. Provide current navigation charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 12 April 2022
Resolution: Vessel provided new electronic charts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 March 2022 Resolved
Except when individual pumps are provided for separate spaces, individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line. A stop-check valve located at a control point or manifold will meet the requirements for both a stop valve and a check valve. Lazarette aft pickup isolating valve handle broken. Repair and demonstrate proper operation of valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 12 April 2022
Resolution: Vessel replaced valve.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 April 2021 Resolved
PENETRATIONS AND OPENINGS IN WATERTIGHT BULKHEADS MUST-HAVE MEANS TO MAKE THEM WATERTIGHT. MARINE INSPECTOR DISCOVERED TWO BULKHEAD PENETRATIONS FROM ENGINE ROOM TO ACCOMODATION SPACE. VESSEL WILL NEED TO BLANK OFF PENETRATIONS TO THE SATISFACTION OF THE MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 14 April 2021
Resolution: vessel provided blanks blocking off old conduit penetrations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 April 2021 Resolved
THE INTENT OF THIS PART IS TO INSURE THAT THE SCANTLINGS, MATERIAL, FASTENINGS, WORKMANSHIP AND ARRANGEMENT OF EACH VESSEL ARE SUCH AS TO PROVIDE FOR SAFE OPERATION IN ACCORDANCE WITH THE TERMS OF ITS CERTIFICATE OF INSPECTION. MARINE INSPECTOR DISCOVERED CLAD WELDING ON STBD QUARTER WELL ABOVE WATER LINE. VESSEL IS TO CROP AND RENEW AREA AT NEXT SCHEDULED DRY DOCK. ADDITIONALLY, FRAMES 6 AND 7 IN THE LAZARETTE ON STBD SIDE FORM CENTERLINE SHOWED CRACKED WELDS. FRAMES TO BE REPAIRED AT NEXT SCHEDULED DRYDOCK.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2022
Resolved 22 June 2022
Resolution: Vessel made repairs that were found satisfactory to attending Marine Inspector. See photos attached to documentation section of activity #7481828
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 April 2021 Resolved
THE DISCHARGE ENDS OF FUEL TANK VENT PIPIES MUST BE FITTED WITH REMOVABLE FLAME SCREENS OR FLAME ARRESTORS. THE FLAME SCREENS MUST CONSIST OF A SINGLE SCREEN OF CORROSION RESISTANT WIRE OF AT LEAST 30 X 30 MESH. PORT AND STBD SIDE FUEL TANK VENTS WERE MISSING SCREENS. VESSEL WILL NEED TO REPLACE SCREENS TO SATISFACTION OF MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 14 April 2021
Resolution: Vessel provided 30X30 flame screens for fuel tank vents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 August 2020 Resolved
Vessel installed new engine control system. In accordance with CVC Policy 17-07, submit the following for review: (1) A limited QFA of the vessel’s propulsion engine control system (throttle), documenting system compliance to CVC Policy 17-07. The limited QFA should only consider loss of power to the control system. (2) A propulsion control drawing should be submitted with an installation/operational test protocol. This test protocol is an abridged document intended to show compliance with 46 CFR.184.620.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 September 2020
Resolved 27 August 2020
Resolution: The required information has been submitted and approved.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 3 March 2020 Resolved
Total personnel onboard is limited to 50 until new stability letter is issued by MSC for incline performed on 19OCT19.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 July 2020
Resolution: New stability letter was issued to the vessel by MSC on 04MAY2020.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 February 2020 Resolved
At every inspection hazardous situations must be corrected. Repair through deck piping for port side fire main.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2020
Resolution: Throught deck fitting replaced and pressure tested, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2020 Resolved
Valves for removing water from diesel strainers must be provided with caps. Replace racor filters drains with metallic caps.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2020
Resolution: All racor drain caps replced with metallic plugs, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 February 2020 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Deficiencies 2-9 provide objective evidence that the vessel is substandard and not pro-actively managing technical and operational requirements. Vessel must complete a satisfactory COI re-inspection prior to any movement.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 March 2020
Resolution: Vessel cleared all open defs. Operational control removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 February 2020 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was missing 2 required life jackets, 4 were in a unserviceable condition, 2 had insufficient retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 February 2020
Resolution: Unserviceable lifejackets replaced, verifed all lifejackets IAW COI, all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 February 2020 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. High level float switch in sewage space was disconnected and the float switch in the main engine space was removed.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 February 2020
Resolution: ER alarms switch replaced and sewage alarms switch properly rewired. Conducted op test of both, all sat.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 27 February 2020 Resolved
When Class 1 doors are installed below a deck the molded line of which at its lowest point at side is less than 7ft above the deepest load line, an indicator light for each door which warns when the door is open must be installed on the bridge. Indicator light was found to non-operational.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 February 2020
Resolution: Switch adjusted, conducted op test, all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 February 2020 Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly. Crew was not testing monthly or logging appropriately.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 February 2020
Resolution: EPRIB tested and logged, operator gave crew training on requirement, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2020 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys. 1 life buoy was missing required plug and had deteriorated grab lines. Repair or provide replacement.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 28 February 2020
Resolution: Ring buoy replaced, all sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 27 February 2020 Resolved
Openings in watertight bulkheads must have mean of close it watertight. Forward Main Engine room bulkhead has open penetrations that are not watertight.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 February 2020
Resolution: Bulkhead penetrations sealed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 27 February 2020 Resolved
Training shall be conducted at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Crew had not been conducting training every 3 months or logging any training.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 February 2020
Resolution: Operator trained crew on required training intervals and documentation, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2020 Resolved
Safety relief valves for air service shall be provided with a substantial lifting device. Safety relief valves on both UPV's were missing lifting devices. Valves were replaced.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Valves replaced with new ASME UV valves at 125 psi, pop tested and hand lifted, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2020 Resolved
Waterlight not attached to ring bouy of STBD side.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Clip replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2020 Resolved
Relaced burst hoses on sewage piping behind false bulkead port side.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Hoses replaced and double clamped, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2020 Resolved
Install blanks on 02 open breakers on 110 panel aft passenger space.
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Blanks installed, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2020 Resolved
Replace plug on top J box and bottom of stair well.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Plug installed, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2020 Resolved
Fuel fill bonding strap unconnected on STBD fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Bonding strap reconnected, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 February 2020 Resolved
Vessel not logging draft readings / or documenting stability prior to vayages.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Operator trained crew on requirements, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 February 2020 Resolved
Lifejacket stowage not properly labeled in salon.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Labled IAW 185.516, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2020 Resolved
STBD MDE shaft seal was found to be leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
Resolution: Packing tightened, all sat.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 23 April 2019 Resolved
Vessel shall not carry more than 50 persons onboard per stability letter.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2019
Resolved 8 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 23 April 2019 Resolved
Repair salon sink water line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 May 2019
Resolution: Pipe repaired.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 23 April 2019 Resolved
Provide FCC operators permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 May 2019
Resolution: Permit provided.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 10 April 2019 Resolved
When the cognizant OCMI or the Commanding Officer, Marine Safety Center determines, in accordance with §178.210, that a vessel must have stability details indicated on its Certificate of Inspection or a stability letter, the owner or operator must submit the information listed in paragraph (b) of this section: Provide an approved stability letter noting stability details for a minimum of 50 passengers, 4 crew and cargo.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2019
Resolved 3 March 2020
Resolution: Incline performed 19OCT19. New CG-835 restricting total personnel onboard to 50.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 10 April 2019 Resolved
Pursuant to 46 CFR 170.010, substitutions for calculations, information, or tests required in sub-chapter T may be approved by the Officer in Charge, Marine Inspection, if the substitution provides an equivalent level of safety. While the vessel is carrying more than 50 total persons the maximum cargo load must be reduced to no more than 15,000 lbs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2019
Resolved 3 March 2020
Resolution: New CG-835 issued for updated stabiility.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 March 2018 Resolved
Destroy 1 adult lifejacket. The lifejacket was not servicable, but the vessel had extra on board.
Action required: 10 - Deficiency Rectified
Due 28 April 2018
Resolved 28 March 2018
Resolution: Corrected during inspection.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 April 2017 Resolved
Provide smoke detectors for all state rooms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 28 April 2017
Resolution: See Narrative.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 13 April 2017 Resolved
Replace rusty hose clamps and fittings on whet exhaust for Portside MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 28 April 2017
Resolution: See Narrative.
Engineering › Steering Gear System › Rudder Stock
Issued 13 April 2017 Resolved
Make repairs to steering gear to prevent excess water leaking when underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 28 April 2017
Resolution: See Narrative.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 April 2017 Resolved
Ensure all switchboards have covers at each breaker location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 28 April 2017
Resolution: See Narrative.
Construction/Loadline › Hull › Hull Plating
Issued 20 July 2016 Resolved
Clad weld 02 isolated pits in lower lounge as marked.
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Clad welds completed.
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 20 July 2016 Resolved
Replace gasket on aft WTD.
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Gasket replaced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 July 2016 Resolved
Cap unused penetration through stbd side of fwd watertight bulkhead in lower lounge.
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 26 July 2016
Resolution: Bulkhead penetration capped.

Casualty record · 6

14 January 1998Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 6 dead · 1 injured · activity 188356
8 June 2011Routine · role: Involved in a Marine Casualty · activity 4041492
20 December 2011Routine · role: Involved in a Marine Casualty · activity 4217675
3 June 2013Routine · role: Involved in a Marine Casualty · activity 4610859
25 July 2013Routine · role: Involved in a Marine Casualty · activity 4665605
14 August 2013Routine · role: Involved in a Marine Casualty · activity 4691451
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.