Records from 1998 to 2026. Most recent: inspection, 4 June 2026.
Inspection history · 49
4 June 2026
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8390809
13 January 2026
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8295284
25 February 2025
Re-Inspection · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8078164
19 March 2024
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7881928
6 March 2023
ACP Periodic Oversight · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7640430
28 March 2022
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7401576
9 March 2022
Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7408626
1 March 2021
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7148099
31 January 2020
ACP Handover Survey · Internal Structural Exam · Examination of Repairs · ACP COI Oversight · Drydock Exam · Cargo Tank Internal · Re-Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6920195
13 December 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6872111
6 November 2019
Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6850865
5 November 2019
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6850037
26 December 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6602788
18 May 2017
Administrative Inspection · Inclining Experiment · Internal Structural Exam · Construction Oversight · Cargo Tank Internal · Periodic Inspection · Drydock Exam · MTSA/ISPS Verification · Plan Review (Other than "T") · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6149089
3 November 2016
Internal Structural Exam · Cargo Tank Internal · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6037370
1 November 2016
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6033000
4 May 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5868734
5 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5876525
29 September 2015
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5732267
29 December 2011
MARPOL Annex VI Survey · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4215092
23 February 2011
Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3950728
11 October 2010
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3867949
21 September 2010
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3854264
11 January 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3660943
7 January 2009
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3391374
20 October 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3349612
16 July 2008
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3270427
15 July 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3270446
28 May 2008
Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3234908
20 May 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3211775
28 March 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3245411
14 January 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3129849
2 February 2007
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2867272
27 April 2006
Hull Examination · Cargo Tank Internal · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2634484
9 November 2005
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2531467
26 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501628
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293961
13 January 2005
Re-Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2274137
2 December 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2264025
19 November 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1950648
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979544
10 June 2003
Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1814278
4 December 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1714165
19 February 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1487283
30 November 2001
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1441942
21 January 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395348
13 April 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 16945
30 January 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125199
23 November 1998
Inclining Experiment · Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372423
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 February 2025
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Smoke Detector in Bow [name withheld] indicated that fire location was in Engine Room when tested on ECR Fire Detection Panel. 74SOLAS(20)II-2/14.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2025
Resolved 3 March 2025
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 March 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Emergency Fire Pump mechanical seal & housing were leaking during operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2024
Resolved 22 March 2024
Resolution: Accepted as condition of class. Report #6320117
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 March 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea. Manual operation of the watertight door in the emergency steer gear compartment is inoperable. Repair to the satisfaction of class.
74SOLAS(20) I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 April 2022
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 4 March 2021
Resolved
All ships irrespective of size, shall have a properly adjusted magnetic compass. Bridge magnetic compass reads 135M. Steering room magnetic compass reads 229M. Gyro compass reads 100T.
74 SOLAS (14) V/19.2.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 5 March 2021
Resolution: ABS provided report# 4673712
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 March 2021
Resolved
Fire-fighting systems and appliances shall be kept in good working order. Fixed CO2 system in paint locker was not serviced since 2019.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 March 2021
Resolved 4 March 2021
Resolution: Witnessed testing of paint locker CO2 system by Vane Brothers.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 December 2019
Resolved
Each Cargo vessel must carry liferafts with an aggregate capacity on each side sufficient to accomodate the total number of persons on board. Vessels' liferafts not on board.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2019
Resolved 16 December 2019
Resolution: Vessel had all liferafts installed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 13 December 2019
Resolved
Each Cargo vessel must carry an immersion suit approved under approval series 160.171. 19 immersion suits are not CG approved. Total persons allowed restricted to 37.
46CFR 199.273
Action required: 705 - Other - as specified
Due 13 December 2019
Resolved 16 December 2019
Resolution: The non-CG approved immersion suits had been removed and replaced with CG approved suits, whistles and lights.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 December 2019
Resolved
Each cargo vessel must carry at least one rescue boat. Rescue boat gas tank degraded.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2019
Resolved 16 December 2019
Resolution: Rescue boat had installed a new fuel tank.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 November 2019
Resolved
An inspection either general or partial depending upon the circumstances shall be made whenever any important repairs are undertaken. Vessel self-reported fuel holding tank-top 4-Center has pitting and wastage. An approx 4"X4" section has been temporarily repaired with "splash-zone" epoxy. Vessel will transit to Charleston SC on or about 09Nov to offload equipment and gear, then proceed to Tampa Ship LLC Tampa Fl. OOA 12Nov to conduct permanent repair. Vessel will arrive at Tampa Ship between 17-21 Nov. Vessel is to contact Sector Hampton Roads if this time-line changes. Vessel is not to carry any cargo or fuel in affected tank, or conduct any operations en-route. Vessel is to contact CG Sector St. Petersburg to schedule repair oversight.
46CFR91.45
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2019
Resolved 13 December 2019
Resolution: New 835 issued for permanent repair at drydock in FEB
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 December 2018
Resolved
Insulation in A-60 overhead in EDG space above fuel tank had been removed during yard period. Replace A-60 insulation to manufacture recomendations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 January 2019
Resolved 16 January 2019
Resolution: ABS Surveyor [name withheld] attended the vessel and confirmed repairs to the SFP.
Fire Fighting › Fire Hoses › Condition
Issued 27 December 2017
Resolved
1 (EACH) fire hose failed during pressure test.Replace new-in-kind.
Action required: 705 - Other - as specified
Resolved 27 December 2017
Resolution: Replaced new-in-kind.
Construction/Loadline › Structures › Deck Plating
Issued 14 November 2017
Resolved
Found 3/8" Main Deck Plate area between FR 50 & 86 (approx) to be wasted and holed. Provide repair proposal to the attending Marine Inspector.
Due 14 November 2017
Resolved 14 November 2017
Resolution: Proposal submitted, replacing new-in-kind or greater scantling.
Construction/Loadline › Structures › Deck Plating
Issued 14 November 2017
Resolved
Complete repairs of the Main Deck Plate area FR 50 to 86 in accordance with the approved repair proposal.
Due 14 November 2017
Resolved 20 December 2017
Resolution: Repaired and tested satisfactory.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 30 October 2017
Resolved
Found several deck and bulkhead penetration transit devices with openings, mismatched modules (different manufactures in same transit device). Inspect all transit devices, utilize single approved system or method (in accordance with manufacturers instructions) to ensure transit devices in fire boundaries maintain the fire-tight/watertight integrity required, to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 20 December 2017
Resolution: All replaced with Roxtec system.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 November 2016
Resolved
Vessel continued to operate beyond the Internal Structural Exam date of 11MAR2016, as required by 46 CFR 126.140 (c). Schedule and complete ISE with USCG before returning to service.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 November 2016
Resolved 3 November 2016
Resolution: ISE completed.
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 1 November 2016
Resolved
Replace turbo seals in both the Bow Thruster and Stern Thruster which are leaking oil.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 3 November 2016
Resolution: Seals replaced.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 November 2016
Resolved
Remove hold back devices in openings in Class A machinery spaces.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 3 November 2016
Resolution: Holdbacks removed.
Lifesaving › Lifebuoys › Serviceable
Issued 1 November 2016
Resolved
02 Lifebuoys found with bad retro.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 3 November 2016
Resolution: Retro replaced.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 1 November 2016
Resolved
Found panel ELP-203 on the 03 level electronics room missing 3 blanks.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 November 2016
Resolved 3 November 2016
Resolution: Blanks replaced.
Fire Fighting › International Shore Connection › Bolts
Issued 1 November 2016
Resolved
Bolts painted and not serviceable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2016
Resolved 3 November 2016
Resolution: Paint removed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 12 October 2010
Resolved
Fix air leak on Flex coupling on both forward and stern thruster prime movers and replace lagging.
Due 11 November 2010
Resolved 2 November 2010
Resolution: New gasket placed on flex coupling.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 January 2008
Resolved
Renew all visual bilge alarms on bridge console, prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2008
Operations/Management › Pollution › Control of Discharge of Oil
Issued 14 January 2008
Resolved
Repair Hydraulic pipe leak located in overhead of paint locker.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 20 October 2008
Communications › Alarms/Indicators › General Alarm
Issued 14 January 2008
Resolved
Demonstrate public address general alarm interupt will reactivate general alarm.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 20 October 2008
Construction/Loadline › Structures › Door
Issued 14 January 2008
Resolved
Repair hydraulic leak on aft watertight motor for class III type door.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 20 October 2008
Engineering › Thrusters › Piping
Issued 14 January 2008
Resolved
Repair hydraulic fill line socket weld in aft thruster room.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 20 October 2008
Construction/Loadline › Structures › Door
Issued 14 January 2008
Resolved
Provide watertight door indicator for door on 1 deck.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 20 October 2008
Communications › Radio Communications › EPIRB
Issued 14 January 2008
Resolved
Move EPIRB to bridge level deck.
Action required: 705 - Other - as specified
Due 14 February 2008
Resolved 20 October 2008
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 9 November 2005
Resolved
The port after steering rudder angle indicator was off by 12 degrees.
Condition: Improper/Lack of Maintenance
Due 9 December 2005
Resolved 16 November 2005
Resolution: Rcvd fax report from vessel representative stating that the rudder angle disparity has been corrected.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 January 2005
Resolved
PROVIDE APPROVED FIRE AND SAFETY PLANS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 February 2005
Resolved 11 February 2005
Lifesaving › Lifebuoys
Issued 19 November 2003
Resolved
Provide new SOLAS tape for all life rings. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2003
Resolved 19 November 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 19 November 2003
Resolved
Renew flame screens on port and starboard fuel oil tank vents on main deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2003
Resolved 19 November 2003
Lifesaving › Lifebuoys
Issued 19 November 2003
Resolved
Renew life ring on port 02-deck level. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2003
Resolved 19 November 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 November 2003
Resolved
Restock all first aid kits throughout vessel including hospital space.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2003
Resolved 19 November 2003
Navigation › Piloting/Steering
Issued 4 December 2002
Resolved
PROVIDE 2002 LIGHT LIST. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2003
Resolved 5 December 2002
Engineering › Steering Gear System
Issued 4 December 2002
Resolved
REPAIR PORT RUDDER ANGLE INDICATOR. LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2003
Resolved 5 December 2002
Documentation › Markings/Placards
Issued 4 December 2002
Resolved
PROVIDE DECK SIGNAL PLACARD LEGACY COMPONENT DESC: DECK CRANE
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2003
Resolved 5 December 2002
Documentation › Markings/Placards
Issued 4 December 2002
Resolved
LABEL EMERGENCY ESCAPE IN RUDDER ROOM. LEGACY COMPONENT DESC: EMERGENCY ESCAPE
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2003
Resolved 5 December 2002
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 December 2002
Resolved
RENEW SMOKE SIGNAL ON PORT BRIDGEWING LIFEBOUY.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 January 2003
Resolved 5 December 2002
Navigation › Collision/Grounding Avoidance
Issued 19 February 2002
Resolved
DEMONSTRATE PROPER OPERATION OF THE RECORDING CAPABILITIES OF THE VESSELS DEPTH RECORDER LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Condition: Improper Installation
Due 19 March 2002
Resolved 19 November 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 19 February 2002
Resolved
CONDUCT MAINTENANCE ON THE RUDDER ROOM STBD MDE EOT LEGACY COMPONENT DESC: ENGINE ORDER TELEGRAPH
Condition: Improper/Lack of Maintenance
Due 19 February 2002
Resolved 19 February 2002
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 February 2002
Resolved
CONDUCT MAINTENANCE ON THE FOLLOWING LIFE RING BUOYS: PORT MAIN DECK AFT, STBD MAIN DECK MIDSHIPS, AND STBD MAIN DECK FWD.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2002
Resolved 19 February 2002
Fire Fighting › Fire Hoses
Issued 19 February 2002
Resolved
PROPERLY STENCIL ALL VESSEL FIREHOSES WITH VESSEL NAME LEGACY COMPONENT DESC: MARKINGS
Due 19 February 2002
Resolved 19 February 2002
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 19 February 2002
Resolved
PROPERLY ADJUST RUDDER ROOM PORT RAI TO SHOW PROPER RUDDER ANGLE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2002
Resolved 19 February 2002
Pollution Prevention/Response › Prevention Equipment
Issued 19 February 2002
Resolved
DEMONSTRATE PROPER OPERATION OF THE OILY WATER SEPARATOR PRIOR TO ALLOWING DISCHARGE OF OILY WASTE, AND PRIOR TO AN INTERNALTIONAL VOYAGE LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2002
Resolved 19 November 2003
Communications › Internal Communications System › Sound-powered Telephone
Issued 19 February 2002
Resolved
PROPERLY REPAIR THE SPP CALL INDICATOR IN THE DRY BULK FLAT
Condition: Improper/Lack of Maintenance
Due 19 February 2002
Resolved 19 February 2002
Documentation
Issued 23 November 1998
Resolved
Provide approved CARGO SECURING MANUAL.
Condition: Unknown
Due 21 December 1998
Resolved 21 December 1998
Electrical
Issued 23 November 1998
Resolved
Prove proper operation of auto start feature on #1 generator._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 January 1999
Resolved 30 January 1999
Navigation
Issued 23 November 1998
Resolved
Provide GMDSS installation report with application for Safety Radio Telephone cert.
Condition: Unknown
Due 30 January 1999
Resolved 30 January 1999
Electrical
Issued 23 November 1998
Resolved
Determine cause and prove proper operation: When shifting from one generator to another and the dry bulk compressor breaker is on, it will trip when the load is transfer between generators. The compressor is not online.
Condition: Unknown
Due 30 January 1999
Resolved 30 January 1999
Documentation
Issued 23 November 1998
Resolved
Provide SOLAS Training/Operations Manual, SOLAS III/Reg 51_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 January 1999
Resolved 30 January 1999
Lifesaving
Issued 23 November 1998
Resolved
Post IMO symbols for lifesaving equipment as required.
Condition: Unknown
Due 30 January 1999
Resolved 30 January 1999