Records from 1998 to 2012. Most recent: inspection, 3 May 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
3 May 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4317978
8 April 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1770158
28 January 2003
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1736501
30 April 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1611163
9 April 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1636377
21 February 2002
Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1488174
25 January 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410471
29 August 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822371
28 June 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443046
2 June 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820333
13 March 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397374
28 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802366
19 February 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1129642
9 February 1999
Initial Certification · Initial Construction-Excluding Oversight · Hull Examination · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378590
19 October 1998
Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 801573
Operations/Management › Equipment Service/Testing
Issued 8 April 2003
Resolved
Repair or replace the SART. LEGACY COMPONENT DESC: SART
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2003
Resolved 8 April 2003
Engineering › Compressed Air System (control)
Issued 8 April 2003
Resolved
Provide proper size gauges for air receivers (250 PSI). LEGACY COMPONENT DESC: Receiver/Bottle
Action required: 705 - Other - as specified
Due 8 May 2003
Resolved 8 May 2003
Lifesaving › Inflatable Liferafts › Painter
Issued 30 April 2002
Resolved
REROUTE PAINTER FOR A STRAIGHT PULL.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2002
Resolved 1 May 2002
Stability
Issued 30 April 2002
Resolved
REMOVE MARINE PORTABLE FROM 02 LEVEL OR PROVIDE PROOF OF NEW STABILITY CALCULATIONS APPROVED BY MARINE SAFETY OFFICE. LEGACY COMPONENT DESC: MARINE PORTABLE TANKS
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2002
Resolved 1 May 2002
Engineering › Bilge Water Management System › Valve
Issued 30 April 2002
Resolved
STENCIL FOREPEAK REACH ROD.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 1 May 2002
Engineering
Issued 30 April 2002
No resolution recorded
PROVIDE PROPER LOCATION FOR BATTERY BANK IN A/C SPACE IAW 46 CFR 129.356 AND 46 CFR 111.15-10. LEGACY COMPONENT DESC: BATTERY LOCATION
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2002 — due date passed with no resolution recorded
Communications › Internal Communications System › Sound-powered Telephone
Issued 30 April 2002
Resolved
REPAIR RUDDER ROOM SOUND POWER PHONE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 2 May 2002
Pollution Prevention/Response › Prevention Equipment
Issued 30 April 2002
Resolved
PROVIDE AND POST FUEL OIL TRANSFER PROCEDURES AT THE TRANSFER STATION. LEGACY COMPONENT DESC: TRANSFERE PROCEDURES
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2002
Resolved 2 May 2002
Communications › Internal Communications System
Issued 30 April 2002
Resolved
REPAIR SOUND POWER PHONE VISUAL INDICATOR IN RUDDER ROOM. LEGACY COMPONENT DESC: Sound-powered Telephone
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 2 May 2002
Communications › Audible Communications
Issued 30 April 2002
Resolved
REPAIR ENGINE ORDER TELEGRAPH SOUND DEVICE ON STARBOARD EOT. LEGACY COMPONENT DESC: EOT
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2002
Resolved 2 May 2002
Documentation › Certificates/Documents
Issued 30 April 2002
Resolved
VESSEL PAST 25APR02 REINSPECTION DATE. LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Navigation
Issued 28 June 2000
Resolved
Prove proper operation of continously recording device for depth sounder tothe satisfaction of attending marine inspector..
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Navigation
Issued 13 March 2000
Resolved
PROVIDE MEANS FOR STORING DEPTH RECORDER DATA OUTPUT TO MEET COMPLIANCE WITH 33 CFR 164, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 March 2000
Resolved 13 March 2000
Navigation
Issued 13 March 2000
Resolved
PROVIDE COMPLETE MANEUVERING DATA AS REQUIRED IN 33 CFR 164, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 16 March 2000
Resolved 27 March 2000
Lifesaving
Issued 9 February 1999
Resolved
Prove proper operation of rescue boat davit launching arrangement using accumulator bottle launch. Rescue boat is still capable of being launched in "dead ship" status._x001C_ _x001C_
Condition: Unknown
Due 10 February 1999
Resolved 6 March 1999
Documentation
Issued 9 February 1999
Resolved
Prior to operating as a well stimulation vessel provide approved operationsmanual for Halliburton equipment onboard.
Condition: Unknown
Due 23 February 1999
Resolved 6 March 1999
Lifesaving
Issued 9 February 1999
Resolved
Install protective guards on areas exposed to port and starboard shafts, inareas outboard of ballast manifold, aft bulk room. The shafts are exposed to walkway leading into shaft alley p/s._x001C_ _x001C_
Condition: Unknown
Due 10 February 1999
Resolved 6 March 1999