MAURY USCG vessel records Sign in
← All vessels

STIM STAR

STIM STAR is a 1999 offshore supply vessel. The Coast Guard has recorded 15 inspections since 1998, most recently in May 2012, along with 17 deficiencies — 1 with no resolution recorded —.

Records from 1998 to 2012. Most recent: inspection, 3 May 2012.

Built
1999
Last inspected
3 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY7290
482912
Flag
UNITED STATES
366757260 (licence lapsed)
Maury page id
psix-482912

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 7 calendar years (1998–2012)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it2248 - Convention (Subpart B), Gross Ton
745 - Convention (Subpart B), Net Ton
2885 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCY7290MMSI 366757260 · expired · compulsorily equipped · granted 13 October 1998, cancelled 13 December 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

3 May 2012 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4317978
8 April 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1770158
28 January 2003 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1736501
30 April 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1611163
9 April 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1636377
21 February 2002 Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1488174
25 January 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410471
29 August 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822371
28 June 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443046
2 June 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820333
13 March 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397374
28 May 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802366
19 February 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1129642
9 February 1999 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378590
19 October 1998 Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 801573

Deficiency record · 17

Operations/Management › Equipment Service/Testing
Issued 8 April 2003 Resolved
Repair or replace the SART. LEGACY COMPONENT DESC: SART
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2003
Resolved 8 April 2003
Engineering › Compressed Air System (control)
Issued 8 April 2003 Resolved
Provide proper size gauges for air receivers (250 PSI). LEGACY COMPONENT DESC: Receiver/Bottle
Action required: 705 - Other - as specified
Due 8 May 2003
Resolved 8 May 2003
Lifesaving › Inflatable Liferafts › Painter
Issued 30 April 2002 Resolved
REROUTE PAINTER FOR A STRAIGHT PULL.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2002
Resolved 1 May 2002
Stability
Issued 30 April 2002 Resolved
REMOVE MARINE PORTABLE FROM 02 LEVEL OR PROVIDE PROOF OF NEW STABILITY CALCULATIONS APPROVED BY MARINE SAFETY OFFICE. LEGACY COMPONENT DESC: MARINE PORTABLE TANKS
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2002
Resolved 1 May 2002
Engineering › Bilge Water Management System › Valve
Issued 30 April 2002 Resolved
STENCIL FOREPEAK REACH ROD.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 1 May 2002
Engineering
Issued 30 April 2002 No resolution recorded
PROVIDE PROPER LOCATION FOR BATTERY BANK IN A/C SPACE IAW 46 CFR 129.356 AND 46 CFR 111.15-10. LEGACY COMPONENT DESC: BATTERY LOCATION
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2002 — due date passed with no resolution recorded
Communications › Internal Communications System › Sound-powered Telephone
Issued 30 April 2002 Resolved
REPAIR RUDDER ROOM SOUND POWER PHONE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 2 May 2002
Pollution Prevention/Response › Prevention Equipment
Issued 30 April 2002 Resolved
PROVIDE AND POST FUEL OIL TRANSFER PROCEDURES AT THE TRANSFER STATION. LEGACY COMPONENT DESC: TRANSFERE PROCEDURES
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2002
Resolved 2 May 2002
Communications › Internal Communications System
Issued 30 April 2002 Resolved
REPAIR SOUND POWER PHONE VISUAL INDICATOR IN RUDDER ROOM. LEGACY COMPONENT DESC: Sound-powered Telephone
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2002
Resolved 2 May 2002
Communications › Audible Communications
Issued 30 April 2002 Resolved
REPAIR ENGINE ORDER TELEGRAPH SOUND DEVICE ON STARBOARD EOT. LEGACY COMPONENT DESC: EOT
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2002
Resolved 2 May 2002
Documentation › Certificates/Documents
Issued 30 April 2002 Resolved
VESSEL PAST 25APR02 REINSPECTION DATE. LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2002
Resolved 1 May 2002
Navigation
Issued 28 June 2000 Resolved
Prove proper operation of continously recording device for depth sounder tothe satisfaction of attending marine inspector..
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Navigation
Issued 13 March 2000 Resolved
PROVIDE MEANS FOR STORING DEPTH RECORDER DATA OUTPUT TO MEET COMPLIANCE WITH 33 CFR 164, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 March 2000
Resolved 13 March 2000
Navigation
Issued 13 March 2000 Resolved
PROVIDE COMPLETE MANEUVERING DATA AS REQUIRED IN 33 CFR 164, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 16 March 2000
Resolved 27 March 2000
Lifesaving
Issued 9 February 1999 Resolved
Prove proper operation of rescue boat davit launching arrangement using accumulator bottle launch. Rescue boat is still capable of being launched in "dead ship" status._x001C_ _x001C_
Condition: Unknown
Due 10 February 1999
Resolved 6 March 1999
Documentation
Issued 9 February 1999 Resolved
Prior to operating as a well stimulation vessel provide approved operationsmanual for Halliburton equipment onboard.
Condition: Unknown
Due 23 February 1999
Resolved 6 March 1999
Lifesaving
Issued 9 February 1999 Resolved
Install protective guards on areas exposed to port and starboard shafts, inareas outboard of ballast manifold, aft bulk room. The shafts are exposed to walkway leading into shaft alley p/s._x001C_ _x001C_
Condition: Unknown
Due 10 February 1999
Resolved 6 March 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.