MAURY USCG vessel records Sign in
← All vessels

JOHNNY MAC

JOHNNY MAC is a 1975 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1985, most recently in June 2026, along with 55 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 2 June 2026.

Built
1975
Last inspected
2 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-48292

Inspections, by type

…with no type recorded2
Years with a record 35 calendar years (1985–2026)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 20.2 ft × 3.0 ft
Registered tonnagegross 35 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWAILUA RIVER MARINA · WAILUA, HI, UNITED STATES · built 1975
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portWAILUA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 61

2 June 2026 Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8386022
11 February 2026 Drydock Extension · Internal Structural Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8313623
4 March 2025 DAPI Audit · COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8088188
4 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7878126
5 June 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7723508
17 May 2023 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7690987
27 February 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7644600
23 March 2022 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7421831
18 May 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7200485
11 February 2020 COI Inspection · Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6907205
3 April 2019 Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6655285
12 March 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6370754
30 August 2016 Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6001753
11 May 2016 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5901611
25 June 2014 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4907624
2 May 2012 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4300817
6 January 2012 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4220198
9 March 2010 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3692809
24 March 2009 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3441016
10 March 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3161888
15 October 2007 Hull Examination · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3080702
16 March 2007 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2889327
17 March 2005 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2308180
21 October 2004 Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2229619
8 March 2004 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2020711
15 March 2002 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1492385
27 March 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1415578
27 February 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1450578
14 March 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1048427
14 March 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1389029
15 February 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 816184
14 December 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1388976
16 February 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1464153
12 August 1998 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372356
11 March 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1426042
22 May 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1110329
14 March 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1400516
17 January 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368021
13 December 1996 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1460045
10 April 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1431618
27 March 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357523
15 February 1996 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355661
27 September 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358927
10 February 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382903
8 November 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1416042
29 September 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1414371
10 February 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1401824
9 December 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382668
3 May 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1150470
18 February 1993 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 836649
19 February 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1261075
15 February 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 918682
20 November 1990 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1219105
16 January 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 918988
8 January 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1219800
31 January 1989 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1040235
16 March 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 987353
29 February 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1336377
8 January 1988 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1015396
23 September 1986 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1006049
15 October 1985 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 989830

Deficiency record · 55

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2026 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel fuel shutoff valve handle was not attached. Provide handle for valve. 46 CFR 182.455(b)(4)
Action required: 10 - Deficiency Rectified
Resolved 2 June 2026
Resolution: Valve handle secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 June 2026 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Vessels remote fuel shutoff station not labeled. Provide marking for fuel shutoff. 46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2026
Resolved 23 June 2026
Resolution: Marking for fuel shutoff provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2026 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Signs of leakage observed around steering pump inlet and discharge. Clean and make repairs to steering system to prevent leaks. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2026
Resolved 23 June 2026
Resolution: Steering system repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 March 2024 Resolved
Vessel Bilge/Fire pump does not remain primed due to a fracture in the suction pipe. Provide satisfactory repairs and prove suction line is capable of holding water to maintain prime.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2024
Resolved 10 April 2024
Resolution: Repairs to vessel's bilge piping system found to be satisfactory. Operational test was completed and no leaks were found. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 March 2024 Resolved
Port engine's exhaust pipe is fractures and leaking exhaust gases into the engine compartment. Provide capable repairs and prove integrity of engine's exhaust system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 March 2024
Resolved 10 April 2024
Resolution: Weld repairs to the damaged areas found to be capable of being vapor tight. Operational test found the bellow serviceable and in satisfactory condition.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 4 March 2024 Resolved
MI found the fuel shut off valve not capable of closing. Provide repairs and prove emergency shut off valve is in serviceable condition.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2024
Resolved 10 April 2024
Resolution: Remote handle to valve was repaired and tested satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 4 March 2024 Resolved
Vessel's fire station are not marked with Fire Station label. Provide label for each fire station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2024
Resolved 10 April 2024
Resolution: Satisfactory painted markings were applied to the vessel's fire stations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 June 2023 Resolved
Propulsion shall be tested during each annual inspection. Do to the vessel awaiting to be refloated from drydock, propulsion test could not be completed. Perform operational tests and complete satisfactory drills.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2023
Resolved 5 September 2023
Resolution: Conducted satisfactory sea trials and drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2019 Resolved
The operation of each piece of machinery on board shall be tested and each subsequent inspection, the port main engine and transmission presented a major lube oil leak while testing. Repair the oil leak and test.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2019
Resolved 9 April 2019
Resolution: Proper repairs were made to the tranmission and bilges were cleaned.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 April 2019 Resolved
Each fire hose must be equipped with a corrsion resistant nozzle, niether fire hose was equipped with appropriate nozzles. Provide fire fighting nozzles.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 April 2019
Resolved 3 April 2019
Resolution: Fire fighting nozzles provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 April 2019 Resolved
Vessel is required to carry 13 child sized life jackets at all times, only 11 were made available. Vessel is restricted to carrying 110 people until the 2 addtional child sized life jackets are available.
Action required: 10 - Deficiency Rectified
Due 3 April 2019
Resolved 3 April 2019
Resolution: Two additional child sized life jackets were provided.
Construction/Loadline › Hull › Bottom Plating
Issued 30 August 2016 Resolved
Areas of rotted wood located on both Port & Stbd side shell plating. All rotted wood to be identified cropped out the replaced in kind.
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 20 January 2017
Resolution: All repairs were completed and found sat. All rotted wood hull plating was replaced in kind.
Electrical › Electric Supply System (service) › Cable
Issued 11 May 2016 Resolved
Found dead end exposed wire leading to Deck light ivo stern.
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 13 May 2016
Resolution: Removed dead end wire and cable leading to removed deck light ivo stern. All items found sat.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 9 March 2010 Resolved
bilge alarm in engine space is not working
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 10 March 2010
Resolution: Found loose wire - replaced female terminal.
Construction/Loadline › Structures › Superstructure
Issued 9 March 2010 Resolved
wood plank on outboard stbd awning is loose
Action required: 705 - Other - as specified
Due 17 March 2010
Resolved 10 March 2010
Resolution: reinstalled plank with nails
Engineering › Fuel Oil Service System › Piping
Issued 24 March 2009 Resolved
Remove all dead end pipes & hoses from engine compartment.
Condition: Improper/Lack of Maintenance
Due 24 March 2009
Resolved 25 March 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 March 2009 Resolved
Remove all dead end wiring in engine compartment.
Condition: Improper/Lack of Maintenance
Due 24 March 2009
Resolved 25 March 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 March 2009 Resolved
Replace expired items in first aid kit.
Due 24 April 2009
Resolved 25 March 2009
Operations/Management › Drills/Instruction › Fire
Issued 10 March 2008 Resolved
Provide proof of crew fire drills.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 24 March 2009
Resolution: Conducted satisfactory drills during this annual.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 10 March 2008 Resolved
Provide proof of servicing of lifesaving equipment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 March 2008
Resolved 26 March 2008
Construction/Loadline › Hull › Hull Plating
Issued 15 October 2007 Resolved
Crop and renw 4ft x 8ft section located port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2007
Resolved 15 October 2007
Construction/Loadline › Hull › Hull Plating
Issued 15 October 2007 Resolved
Crop and renew 2ft x 2ft section located fwd stbd side bow.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2007
Resolved 15 October 2007
Construction/Loadline › Hull › Hull Plating
Issued 15 October 2007 Resolved
Crop and renew bottom hull plating.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2007
Resolved 15 October 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 October 2007 Resolved
Renew exhaust piping stbd side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2007
Resolved 15 October 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 15 October 2007 Resolved
Prove proper operation of main engines.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2007
Resolved 15 October 2007
Engineering › Sea-water System (primary cooling) › Valve
Issued 15 October 2007 Resolved
Renew main engine raw water valves.
Condition: Unknown
Due 15 October 2007
Resolved 15 October 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 March 2005 Resolved
Missing (2) battery box covers. Owner installed battery box covers.
Condition: Unknown
Due 17 March 2005
Resolved 17 March 2005
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 March 2005 Resolved
Failed (2) child lifejackets. Owner replaced (2) child lifejackets with new ones.
Condition: Unknown
Due 21 March 2005
Resolved 28 March 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 21 October 2004 Resolved
High water alarm OOC. Alarm repaired and tested SAT.
Condition: Unknown
Due 21 October 2004
Resolved 21 October 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 October 2004 Resolved
Repair lifeline for lifebuoy. Lifebuoy replaced with new unit.
Condition: Unknown
Due 21 October 2004
Resolved 21 October 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 October 2004 Resolved
Replace port navigation light prior to operations. Port nav light replaced and tested SAT.
Condition: Unknown
Due 21 October 2004
Resolved 21 October 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 15 March 2002 Resolved
Replace retro-reflective material on 35 adult and 10 childrens lifejackets in accordance with 46 CFR 185.604(h). LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 22 March 2002
Resolved 4 April 2002
Construction/Loadline
Issued 27 February 2001 Resolved
Dry dock and repair wood rot at port side 10' FWD from stern on bottom hull.
Condition: Unknown
Due 27 February 2001
Resolved 27 February 2001
Construction/Loadline
Issued 14 December 1999 Resolved
Crop and renew area of wood rot port side approximately 1' aft at the waterline.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Construction/Loadline
Issued 14 December 1999 Resolved
Crop and renew area of wood rot on pusher barge starboard side at the waterline amidships.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Construction/Loadline
Issued 14 December 1999 Resolved
Crop and renew area of wood rot port side of vessel approximately 20' aft just above the waterline.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Lifesaving
Issued 11 March 1998 Resolved
Inadequate documentation of all crew members receiving required training and drills. Proper documentation of training and drills to be accomplishedin accordance with 46 CFR 185.420/520/524._x001C_
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Fire Fighting
Issued 11 March 1998 Resolved
Engineroom vent ducts do not have means of closure in event of fire. Vessel is to provide means of closure to all E/R vents in accordance with 46 CFR 185.420/520/524._x001C_
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Lifesaving
Issued 14 March 1997 Resolved
Provide a CG approved first aid kit as required by 46 CFR 184.710.
Condition: Unknown
Due 14 March 1997
Resolved 14 March 1997
Documentation
Issued 27 March 1996 Resolved
Provide evidence of compliance with 46 CFR 185.420, crew training emergencydrills.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Documentation
Issued 27 March 1996 Resolved
Provide emergency broadcast placard IAW 46 CFR 184.506.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Documentation
Issued 27 March 1996 Resolved
Provide evidence of compliance with 46 CFR 185.524, fire fighting drills_x001C_ and training; logged.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Electrical
Issued 27 March 1996 Resolved
Provide portable lights IAW 46 CFR 183.420.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Documentation
Issued 27 March 1996 Resolved
Provide evidence of compliance with 46 CFR 185.520, abandon ship and man overboard drills & training.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Lifesaving
Issued 27 March 1996 Resolved
Renew PFD reflective tape as needed.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Fire Fighting
Issued 27 March 1996 Resolved
Provide one additional B-II portable fire extinguisher.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Engineering
Issued 29 September 1994 Resolved
PROVIDE PROPER OIL CONTAINMENT AROUND THE FUEL VENT, FUEL INTAKE, AND ALL HYDRAULIC STEERING RAMS ON THE PUSHER UNIT.
Condition: Unknown
Due 29 September 1994
Resolved 29 September 1994
Navigation
Issued 18 February 1993 Resolved
INSTALL PROPER STERN LIGHT WHICH DISPLAYS 135 DEGREE ARC SEEN FROM THE STERN OF THE VESSEL FOR TWO MILES. VESSEL IS RESTRICTED TO DAYLIGHT OPERATION ONLY PENDING COMPLETION OF ABOVE REQUIREMENT.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Navigation
Issued 18 February 1993 Resolved
RENEW FLEXIBLE HOSE TO HYDRAULIC STEERING UNIT BETWEEN BARGE AND PUSHER UNIT.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Navigation
Issued 18 February 1993 Resolved
CORRECT INSTALLATION OF MASTHEAD LIGHT. THIS LIGHT IS TO DISPLAY A 225 DEGREE ARC FROM A POSITION AT LEAST ONE METER ABOVE THE SIDELIGHTS AS SEEN FROM THE BOW OF THE VESSEL FOR THREE MILES. VESSEL IS RESTRICTED TO DAYLIGHT OPERATION ONLY PENDING COMPLETION OF ABOVE REQUIREMENT.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Electrical
Issued 18 February 1993 Resolved
RENEW POWER CABLE TO SHIP'S SERVICE GENERATOR BETWEEN BARGE AND PUSHER UNIT.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Fire Fighting
Issued 18 February 1993 Resolved
RENEW MOUNTING BRACKET FOR STEERING STATION FIRE EXTINGUISHER.
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Engineering
Issued 8 January 1990 Resolved
INSTALL BELT GUARDS ON PORT AND STARBOARD ENGINES.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Documentation
Issued 8 January 1990 Resolved
POST SUITABLE EMERGENCY PROCEDURE INSTRUCTIONS.
Condition: Unknown
Due 8 January 1990
Resolved 8 January 1990
Engineering
Issued 8 January 1988 Resolved
PROVIDE FLAME DEFLECTOR SHIELDS FOR THE RACOR FUEL FILTERS.
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.