MAURY USCG vessel records
← All vessels

NANCY BEAN

Built
1975
Last inspected
10 June 2005
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 10 June 2005
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 21 calendar years (1985–2005)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-48293

Documentation record

Registered dimensions (L × B × D)200.1 ft × 56.1 ft × 12.9 ft
Registered tonnagegross 1,295 / net 1,295
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEQUITABLE EQUIPMENT CO · MADISONVILLE, LA, UNITED STATES · built 1975
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEWPORT NEWS, VA
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1295 - Regulatory (Subpart C or D), Gross Ton
1295 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

10 June 2005 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2381505
11 May 2005 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2354883
7 October 2004 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2215736
28 August 2003 Periodic Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1889473
7 August 2002 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1657749
8 July 2002 Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1642784
26 July 2001 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1457970
19 July 2000 COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1436432
9 July 1999 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1438871
16 June 1998 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1454568
18 June 1997 Hull Examination · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1427364
20 June 1996 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1388053
3 August 1995 Hull Examination · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1432928
5 June 1995 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1185077
28 June 1994 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1392028
24 August 1993 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 848295
13 May 1993 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1145738
18 June 1992 COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 950692
13 May 1992 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1255044
29 November 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1252196
18 July 1991 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1249034
20 June 1991 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1247768
10 December 1990 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 928690
24 May 1990 Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1242614
21 June 1989 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1351858
15 June 1989 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1205279
15 June 1988 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1338532
12 June 1987 Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1334135
6 May 1986 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1296183
9 May 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1287981

Deficiency record · 17

Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 10 June 2005 Resolved
Prove that both (start air) pressure vessels have passed a shop inspection (ASME/USCG) and provide labels IAW 46 CFR Part 54 NLT 10 July 05.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 July 2005
Resolved 1 August 2005
Resolution: Vessel taken out of certificated service this date.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 10 June 2005 Resolved
Renew both portable, dry chemical fire extinguishers NLT 10 July 05.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2005
Resolved 1 August 2005
Resolution: Vessel taken out of certificated service this date.
Electrical › Lighting (service)
Issued 7 August 2002 Resolved
Prove proper operation of deck service lighting on forward edge of deck house. LEGACY COMPONENT DESC: Deck Lighting
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 28 August 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 7 August 2002 Resolved
Repair emegency shut down on cargo trim/transfer pump. LEGACY COMPONENT DESC: Cargo Pump
Action required: 705 - Other - as specified
Due 7 September 2002
Resolved 28 August 2003
Deck/Cargo
Issued 26 July 2001 Resolved
PROVE PROPER OPERATION OF EMERGENCY SHUTDOWN ON TRIM PUMP.
Condition: Unknown
Due 26 August 2001
Resolved 26 July 2001
Navigation
Issued 9 July 1999 Resolved
PROVIDE STBD NAVIGATION LIGHT ON BARGE.
Condition: Unknown
Due 23 July 1999
Resolved 22 July 1999
Fire Fighting
Issued 9 July 1999 Resolved
PROVIDE SERVICE REPORT FOR SEMI-PORTABLE PKP EXTINGUISHERS.
Condition: Unknown
Due 23 July 1999
Resolved 22 July 1999
Construction/Loadline
Issued 5 June 1995 Resolved
DRYDOCK THE VESSEL NO LATER THAN 31 JUL 95. DO NOT LOAD OR CARRY PRODUCT UNTIL VESSEL HAS BEEN EXAMINED.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Electrical
Issued 24 August 1993 Resolved
INSTALL DRIP-PROOF BATTERY CHARGER THAT MEETS UL STANDARD 1236.
Condition: Unknown
Due 24 August 1993
Resolved 24 August 1993
Engineering
Issued 24 August 1993 Resolved
REPAIR OR REPLACE BROKEN GAUGES ON ALL CARGO PUMPS.
Condition: Unknown
Due 24 August 1993
Resolved 24 August 1993
Documentation
Issued 20 June 1991 Resolved
PROVIDE POLLUTION PREVENTION PLACARD.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Deck/Cargo
Issued 20 June 1991 Resolved
PROVIDE AIR RELIEF VALVE WITH PROPER HAND DELIVERY GEAR.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Deck/Cargo
Issued 24 May 1990 Resolved
AS OF 18JUN90, VESSEL IS PROHIBITED FROM LOADING CARGO IN ITS FOREPEAK AND/OR AFTERPEAK TANKS UNTIL SATISFACTORY STABILITY INFORMATION IS PROVIDED AND APPROVED BY COMMANDANT (G-MSC-3), WASHINGTON, D.C.
Condition: Unknown
Due 24 May 1990
Resolved 24 May 1990
Deck/Cargo
Issued 15 June 1989 Resolved
OPEN AND MAKE PV VALVES AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Deck/Cargo
Issued 15 June 1989 Resolved
PROVIDE CARGO HOSE FOR INSPECTION AND TEST TO 1 1/2 MAWP.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Engineering
Issued 15 June 1989 Resolved
HYDRO TEST BOTH MAIN DECK AIR RECEIVERS TO 1 1/4 MAWP AND RENEW MANUFACTURER'S DATA PLATES FOR SAME.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Fire Fighting
Issued 15 June 1989 Resolved
PROVIDE SERVICING REPORT FOR BOTH OR DECK SEMIPORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.