Records from 1981 to 1999. Most recent: inspection, 23 December 1999.
Documentation record
Registered dimensions (L × B × D)52.8 ft × 17.8 ft × 7.3 ft
Registered tonnagegross 48 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROSE CRAFT INC · HARKERS ISLAND NC, UNITED STATES · built 1975
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPANAMA CITY BEACH, FL
Trade endorsementsFishery
DocumentationNo Operation - PM · issued 18 February 1993 · expires 28 February 2002
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Regulatory (Subpart C or D), Gross Ton
32 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
23 December 1999
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 823568
23 June 1999
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1445513
8 March 1999
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1120158
11 February 1999
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427611
6 July 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1402684
16 July 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1425937
11 December 1996
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1424281
21 June 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1398472
24 May 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1387799
1 April 1995
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1374260
12 May 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1323669
30 September 1993
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 691647
22 August 1993
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 82255
27 April 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1138944
19 January 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 831484
29 July 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962060
30 June 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 946966
26 March 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 952501
5 November 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1136472
21 October 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962697
27 July 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 927059
19 July 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1239110
27 April 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1236935
4 April 1990
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 922471
29 April 1987
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1022511
16 April 1986
Credit Drydock · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 999265
6 August 1985
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 985176
1 July 1985
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1287166
9 May 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 983468
15 March 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 982278
30 April 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1281236
29 February 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971145
24 August 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971019
24 August 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1276172
12 April 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969533
20 March 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277511
Engineering
Issued 27 April 1990
Resolved
INSTALL PROPER BELT GUARD ON PORT MAIN ENGINE.
Condition: Unknown
Due 27 April 1990
Resolved 27 April 1990
Documentation
Issued 27 April 1990
Resolved
POST CERTIFICATE OF INSPECTION, EMERGENCY CHECKOFF LIST, FCC STATION LICENSE, AND FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 27 April 1990
Resolved 27 April 1990
Engineering
Issued 27 April 1990
Resolved
EXTEND ONE ENGINE ROOM EXHAUST VENT PIPE TO A POSITION NEAR BILGE.
Condition: Unknown
Due 27 April 1990
Resolved 27 April 1990
Documentation
Issued 16 April 1986
Resolved
PROVIDE AN FCC STATION LICENSE ON BOARD FOR WYT 9879.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Accommodation/Occupational Safety
Issued 1 July 1985
Resolved
INSTALL VENT SCREENS ON MSD VENTS.
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Lifesaving
Issued 1 July 1985
Resolved
REPLACE EMERGENCY LIGHTS WITH OPPROVED TYPE
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Construction/Loadline
Issued 1 July 1985
Resolved
MAKE COLLISION BULKHEAD WATERTIGHT BY REMOVING OR SEALING THE OPENING IN SAME.
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Construction/Loadline
Issued 1 July 1985
Resolved
REMOVE TINTED WINDOWS FROM PILOTHOUSE.
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Lifesaving
Issued 1 July 1985
Resolved
REPLACE WEAKLINK ON LIFERAFT AND INSTALL REFLECTIVE TAPE ON SAME.
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Fire Fighting
Issued 1 July 1985
Resolved
REPLACE OR REMOVE DAMAGED FIRE EXTINGUISHERS.
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Lifesaving
Issued 1 July 1985
Resolved
PROVIDE SEPARATE STOWAGE FOR CHILDS PFD.
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Construction/Loadline
Issued 1 July 1985
Resolved
STENCIL EMERGENCY FUEL SHUTOFFS.
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Accommodation/Occupational Safety
Issued 30 April 1984
Resolved
PROVIDE FOR THE BOW DK AREA ACCESS. TO PASS. & CREW A HANDRAIL OF AT LEAST 30" HIGH THAT CONSIST OF EVENLY SPREED COURSES NOT GREATER THAN 12" APART.
Condition: Unknown
Due 30 April 1984
Resolved 30 April 1984