GERONIMO

GERONIMO is a 1998 school ship. The Coast Guard has recorded 42 inspections since 1998, most recently in June 2025, along with 33 deficiencies and 1 casualty investigation in 2013.

Records from 1998 to 2025. Most recent: inspection, 23 June 2025.

Built
1998
Last inspected
23 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY7348
483337
Flag
UNITED STATES
366757430
Maury page id
psix-483337

Inspections, by type

…with no type recorded3
Years with a record 25 calendar years (1998–2025)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 1981.

Documentation record

Registered dimensions (L × B × D)69.7 ft × 18.6 ft × 8.2 ft
Registered tonnagegross 53 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEW ENGLAND BOATWORKS INC · PORTSMOUTH, RI, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portNEWPORT, RI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 June 2026 · expires 31 July 2027
Service, as the file records itSchool Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it53 - Simplified, Gross Ton
47 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY7348MMSI 366757430 · active · voluntarily equipped · granted 7 August 2018, expires 19 October 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 42

23 June 2025 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8111437
29 May 2025 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8100099
5 February 2024 Annual Inspection
Physical examination · Activities Europe · Activity 7860492
12 October 2023 Drydock Exam · Internal Structural Exam
Physical examination · Activities Europe · Activity 7807239
5 July 2023 Annual Inspection · DAPI Audit
Physical examination · Activities Europe · Activity 7735880
21 April 2022 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7435649
16 October 2021 Type not recorded
No type recorded · Station Fort Macon · USCG East District (CGD-E) · Activity 7334113
9 September 2021 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7298239
7 July 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7173322
11 September 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7049857
1 July 2020 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6992342
10 September 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6790305
11 July 2019 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6678931
3 April 2019 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6655120
27 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6524262
27 July 2018 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6393271
28 January 2018 Type not recorded
No type recorded · Station Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6345107
22 August 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6237487
12 May 2017 COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6069928
5 August 2016 Annual Inspection
Physical examination · Activities Europe · Activity 5963044
14 May 2012 DAPI Audit · MARPOL Annex VI Survey · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4253670
23 February 2011 Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3950765
1 March 2010 DAPI Audit · Periodic Inspection · MARPOL Annex VI Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3688031
7 May 2009 Deficiency Check · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3445563
5 June 2008 Examination of Repairs · Plan Review (Other than "T") · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3414453
8 May 2008 Deficiency Check · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3176791
29 October 2007 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 3089694
13 September 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3019336
11 May 2007 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2904259
12 May 2006 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2618967
2 March 2006 Administrative Inspection
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2594749
4 May 2005 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2349348
16 August 2004 Hull Examination · Internal Structural Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2167287
13 May 2004 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2065413
12 May 2003 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1791841
17 September 2002 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1676503
15 May 2002 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1608931
30 July 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1418941
14 February 2001 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1059363
18 May 2000 COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1456833
14 September 1999 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1393410
7 October 1998 Initial Certification · Inclining Experiment · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1470748

Deficiency record · 33

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 June 2025 Resolved
Fire extinguishers and fire extinguishing systems must be inspected annualy. The fireboy in the aft paint locker is condemned and fire extinguishers have not been serviced. Replace fireboy and provide annual fire extinguishing service report for all fire extinguishers prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2025
Resolved 22 September 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 May 2025 Resolved
FCC Radiosafety Certificate and Bridge-to-Bridge Certificate are expired. Renew certificates. 47 CFR 80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 23 September 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 November 2023 Resolved
Internal Structural Exam -Chalk test of all watertight doors -Water test all hatches -Remove dead-end wires and decommission electrical wiring on water tanks. Cite: 46 CFR 169.229(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2023
Resolved 9 March 2024
Resolution: Verified all items rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2023 Resolved
Each personal flotation device must have at least 200 sq. cm. (31 sq. in.) of retroreflective material attached on its front side and at least 200 sq. cm. on its back side. If the personal flotation device is reversible, retroreflective material must be applied as described above on both sides. Replace the deteriorated strips of SOLAS retroreflective tape on the life buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 3 November 2023
Resolution: SOLAS tape was replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 July 2023 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. The Maritime Consortium enrollment for was expired and the alcohol test kits expire in Jul2023. Provide documentation from "pending" crewmember. Review company/Maritime Consortium policy for random drug testing and post casualty drug/alcohol testing while operating away from the U.S. Cite: 46 CFR 16.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 11 July 2023
Resolution: Received confirmation of enrollment into The Maritime Consortium.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 July 2023 Resolved
Each inflatable liferaft has been serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures meeting the requirements of part 160, part 160.151, of this chapter— (i) No later than the month and year on its servicing sticker affixed under 46 CFR 160.151–57(n), except that servicing may be delayed until the next scheduled inspection of the vessel, provided that the delay does not exceed 5 months. Both liferaft servicing dates are extended until 23Jan2024. 705: Deficiency due 23Jan2024. Cite: 46 CFR 169.837(f)
Action required: 705 - Other - as specified
Due 9 January 2024
Resolved 9 March 2024
Resolution: Verified validity of both liferaft servicing certificates.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 July 2023 Resolved
At each inspection for certification and periodic inspection and at such other times as considered necessary, all fire extinguishing equipment must be inspected to ensure it is in suitable condition. Tests may be necessary to determine the condition of the equipment. The inspector must verify that the following tests and inspections have been conducted by a qualified servicing facility at least once every 12 months. Noted the CO2 cylinder and time delay are due for testing in 2023. Provide supporting documentation to extend annual servicing of fire system until November 2023 yard period. Provide annual servicing report for the fixed gas CO2 system and paint locker FM 200 system. Cite: 46 CFR 169.247(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2023
Resolved 9 March 2024
Resolution: Verified annual servicing report onboard. Uploaded report to documents tab.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 April 2022 Resolved
Prior to the expiration of the certificate of inspection a request for renewal of the sailing school vessel designation must be submitted in the same manner as described in 46 CFR 169.218; the subject matter request has not been submitted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 28 April 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 April 2022 Resolved
The master shall conduct a fire and boat drill within 24 hours of leaving a port if 25 percent of the crew have been replaced; the subject matter drills must be conducted in the presence of a Marine Inspector prior to departing Wilmington, NC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2022
Resolved 25 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 July 2021 Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date: Coast Pilot, Light lists, Tides tables and Current tables. Vessel publications are not up-to-date. Provided updated publications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 15 July 2021
Resolution: Publications provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 July 2021 Resolved
Marine employer shall establish programs for the chemical testing for drugs on a random basis. Current enrollment expired. Provide up-to-date enrollment of all crew members.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 15 July 2021
Resolution: Documentation provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 July 2019 Resolved
First aid kit contents expired.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 18 July 2019
Resolution: New first aid kit purchased and installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018 Resolved
Vsl is broadcasting: Invalid IMO #, no dimension information (AIS Antenna Position ABCD values equals 0), and not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 11 July 2019
Resolution: Verified AIS info correct.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 July 2018 Resolved
Replace the expired ammonia inhalants
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2018
Resolved 6 August 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 July 2018 Resolved
Prior to the carriage of students, replace the smoke detector in the main salon with one listed by an independent testing laboratory.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2018
Resolved 28 July 2018
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 12 August 2016 Resolved
Provide servicing report of 04 extinguishers that need recharging.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2016
Resolution: Provided receipt of new extinguishers.
Lifesaving › Rocket Parachute Flares › General
Issued 12 August 2016 Resolved
Provide receipt for 04 parachute flares to replace 04 that will be expiring in Oct 2016.
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 22 August 2016
Resolution: Provided receipt of new flares.
Communications › Radio Communications › EPIRB
Issued 12 August 2016 Resolved
Provide proof of registration.
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 22 August 2016
Resolution: Provided receipt of registration.
Fire Fighting › Fire Hoses › Connections
Issued 6 May 2011 Resolved
Brass end fitting broken; unable to connect nozzle.
Action required: 705 - Other - as specified
Due 11 May 2011
Resolved 11 May 2011
Resolution: New fitting installed, corrected.
Lifesaving › Immersion Suits › Not on Board
Issued 7 May 2009 Resolved
Provide onboard required 2 additional exposure suits in accordance with 46 CFR 169.551. Total persons allowed will be reduced to 11 until exposure suits are on board.
Action required: 705 - Other - as specified
Due 22 May 2009
Resolved 22 May 2009
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 8 May 2008 Resolved
Vessel missing required amount of orange smoke distress signals.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 12 May 2008
Resolution: An additional 06 red parachute flares were added to replace the orange smoke distress signals, allowing the vessel to meet 46CFR169.553 (c)(2)
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 May 2008 Resolved
Previous inspection date for portable and fixed extinguishing system was May 2007. Must provide certificates for both upon completion of yearly inspection.
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 27 May 2008
Fire Fighting › Fire Main › Material
Issued 8 May 2008 Resolved
Bring fire main into compliance with 46CFR169.640 during Fall 2008 hauls out period.
Action required: 705 - Other - as specified
Due 30 December 2008
Resolved 26 September 2008
Construction/Loadline › Markings › Load Line Mark
Issued 13 September 2007 Resolved
Provide Draft/Load Marks in accordance with 46 CFR 169.755.
Action required: 705 - Other - as specified
Due 18 September 2007
Resolved 18 September 2007
Resolution: Added load mark to both port and starboard side reflecting 4'' 6 1/2" of freeboard at the top of the triangle.
Fire Fighting › Nozzles › Type
Issued 4 May 2005 Resolved
Install approved type fire nozzle on fire hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2005
Resolved 24 May 2005
Resolution: Approved nozzle provided sat.
Communications › Radio Communications › EPIRB
Issued 4 May 2005 Resolved
Replace broken switch on EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2005
Resolved 24 May 2005
Resolution: EPIRB switch replaced sat.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 4 May 2005 Resolved
Complete all vessel underway drills with new arriving students.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2005
Resolved 16 June 2005
Resolution: MOB drills conducted sat.
Communications › Automatic Identification System (AIS)
Issued 15 May 2002 Resolved
LABEL RADIO CALL SIGN ON DECK OR HOUSE ROOF. 169.750
Due 15 June 2002
Resolved 3 June 2002
Fire Fighting › Means of Escape
Issued 15 May 2002 Resolved
LABEL EMERGENCY ESCAPE HATCH FROM FWD BERTHING AREA.169.745 LEGACY COMPONENT DESC: Escape Route Signs
Condition: Unknown
Due 15 June 2002
Resolved 3 June 2002
Fire Fighting › Miscellaneous Items
Issued 15 May 2002 Resolved
LABEL FIRE HOSE STATION
Due 15 June 2002
Resolved 3 June 2002
Fire Fighting › Miscellaneous Items
Issued 15 May 2002 Resolved
PROVIDE FIRE AXE.
Condition: Unknown
Due 15 June 2002
Resolved 3 June 2002
Lifesaving
Issued 15 May 2002 Resolved
PROVE EXISTING SAFETY HARNESSES USED MET OR EXCEED ORC STANDARDS.
Due 15 June 2002
Resolved 29 May 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 15 May 2002 Resolved
PROVIDE OVEN DOOR LATCHES FOR HEAVY SEAS.
Condition: Improper Installation
Due 15 June 2002
Resolved 3 June 2002

Casualty record · 1

14 June 2013Routine · role: Involved in a Marine Casualty · activity 4620060
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.