Records from 2013 to 2025. Most recent: inspection, 23 June 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)69.7 ft × 18.6 ft × 8.2 ft
Registered tonnagegross 53 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEW ENGLAND BOATWORKS INC · PORTSMOUTH, RI, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portNEWPORT, RI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 June 2026 · expires 31 July 2027
Service, as the file records itSchool Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it53 - Simplified, Gross Ton
47 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
20 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 20
23 June 2025
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8111437
29 May 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8100099
5 February 2024
Annual Inspection
Physical examination · Activities Europe · Activity 7860492
12 October 2023
Drydock Exam · Internal Structural Exam
Physical examination · Activities Europe · Activity 7807239
5 July 2023
Annual Inspection · DAPI Audit
Physical examination · Activities Europe · Activity 7735880
21 April 2022
COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7435649
16 October 2021
Type not recorded
No type recorded · Station Fort Macon · USCG East District (CGD-E) · Activity 7334113
9 September 2021
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7298239
7 July 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7173322
11 September 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7049857
1 July 2020
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6992342
10 September 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6790305
11 July 2019
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6678931
3 April 2019
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6655120
27 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6524262
27 July 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6393271
28 January 2018
Type not recorded
No type recorded · Station Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6345107
22 August 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6237487
12 May 2017
COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6069928
5 August 2016
Annual Inspection
Physical examination · Activities Europe · Activity 5963044
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 June 2025
Resolved
Fire extinguishers and fire extinguishing systems must be inspected annualy. The fireboy in the aft paint locker is condemned and fire extinguishers have not been serviced. Replace fireboy and provide annual fire extinguishing service report for all fire extinguishers prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 June 2025
Resolved 22 September 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 May 2025
Resolved
FCC Radiosafety Certificate and Bridge-to-Bridge Certificate are expired. Renew certificates.
47 CFR 80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 23 September 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 November 2023
Resolved
Internal Structural Exam
-Chalk test of all watertight doors
-Water test all hatches
-Remove dead-end wires and decommission electrical wiring on water tanks.
Cite: 46 CFR 169.229(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2023
Resolved 9 March 2024
Resolution: Verified all items rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2023
Resolved
Each personal flotation device must have at least 200 sq. cm. (31 sq. in.) of retroreflective material attached on its front side and at least 200 sq. cm. on its back side. If the personal flotation device is reversible, retroreflective material must be applied as described above on both sides. Replace the deteriorated strips of SOLAS retroreflective tape on the life buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 3 November 2023
Resolution: SOLAS tape was replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 July 2023
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. The Maritime Consortium enrollment for was expired and the alcohol test kits expire in Jul2023. Provide documentation from "pending" crewmember. Review company/Maritime Consortium policy for random drug testing and post casualty drug/alcohol testing while operating away from the U.S.
Cite: 46 CFR 16.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2023
Resolved 11 July 2023
Resolution: Received confirmation of enrollment into The Maritime Consortium.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 July 2023
Resolved
Each inflatable liferaft has been serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures meeting the requirements of part 160, part 160.151, of this chapter— (i) No later than the month and year on its servicing sticker affixed under 46 CFR 160.151–57(n), except that servicing may be delayed until the next scheduled inspection of the vessel, provided that the delay does not exceed 5 months. Both liferaft servicing dates are extended until 23Jan2024. 705: Deficiency due 23Jan2024.
Cite: 46 CFR 169.837(f)
Action required: 705 - Other - as specified
Due 9 January 2024
Resolved 9 March 2024
Resolution: Verified validity of both liferaft servicing certificates.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 July 2023
Resolved
At each inspection for certification and periodic inspection and at such other times as considered necessary, all fire extinguishing equipment must be inspected to ensure it is in suitable condition. Tests may be necessary to determine the condition of the equipment. The inspector must verify that the following tests and inspections have been conducted by a qualified servicing facility at least once every 12 months. Noted the CO2 cylinder and time delay are due for testing in 2023. Provide supporting documentation to extend annual servicing of fire system until November 2023 yard period. Provide annual servicing report for the fixed gas CO2 system and paint locker FM 200 system.
Cite: 46 CFR 169.247(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2023
Resolved 9 March 2024
Resolution: Verified annual servicing report onboard. Uploaded report to documents tab.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 April 2022
Resolved
Prior to the expiration of the certificate of inspection a request for renewal of the sailing school vessel designation must be submitted in the same manner as described in 46 CFR 169.218; the subject matter request has not been submitted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 28 April 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 21 April 2022
Resolved
The master shall conduct a fire and boat drill within 24 hours of leaving a port if 25 percent of the crew have been replaced; the subject matter drills must be conducted in the presence of a Marine Inspector prior to departing Wilmington, NC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2022
Resolved 25 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 July 2021
Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date: Coast Pilot, Light lists, Tides tables and Current tables. Vessel publications are not up-to-date. Provided updated publications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 15 July 2021
Resolution: Publications provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 July 2021
Resolved
Marine employer shall establish programs for the chemical testing for drugs on a random basis. Current enrollment expired. Provide up-to-date enrollment of all crew members.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 15 July 2021
Resolution: Documentation provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 July 2019
Resolved
First aid kit contents expired.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 18 July 2019
Resolution: New first aid kit purchased and installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: Invalid IMO #, no dimension information (AIS Antenna Position ABCD values equals 0), and not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 11 July 2019
Resolution: Verified AIS info correct.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 July 2018
Resolved
Replace the expired ammonia inhalants
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2018
Resolved 6 August 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 July 2018
Resolved
Prior to the carriage of students, replace the smoke detector in the main salon with one listed by an independent testing laboratory.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2018
Resolved 28 July 2018
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 12 August 2016
Resolved
Provide servicing report of 04 extinguishers that need recharging.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2016
Resolution: Provided receipt of new extinguishers.
Lifesaving › Rocket Parachute Flares › General
Issued 12 August 2016
Resolved
Provide receipt for 04 parachute flares to replace 04 that will be expiring in Oct 2016.
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 22 August 2016
Resolution: Provided receipt of new flares.
Communications › Radio Communications › EPIRB
Issued 12 August 2016
Resolved
Provide proof of registration.
Action required: 705 - Other - as specified
Due 12 September 2016
Resolved 22 August 2016
Resolution: Provided receipt of registration.