Behind this panel: 4 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 4
11 August 2017
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6235550
5 July 2017
Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6191941
21 December 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6058878
3 February 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5808580
Lifesaving › Launching Appliances › Winch
Issued 5 July 2017
Resolved
Port side lifeboat recovery winch inoperable due to faulty switch. SOLAS I/11(b) 16ac
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 11 August 2017
Resolution: Vessel class issued class report clearing deficiency. Verified on board by USCG MI.
Construction/Loadline › Structures › Deck Plating
Issued 5 July 2017
Resolved
Wooden deck installed above welding shop area in midship superstructure posing fire hazard. SOLAS I/11(B) 16ac
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 11 August 2017
Resolution: Vessel class issued class report clearing deficiency. Verified on board by USCG MI.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 5 July 2017
Resolved
Main fire pump, ballast pump and ship's main shaft seal all excessively leaking. SOLAS I/11(b) 16ac
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 11 August 2017
Resolution: Vessel class issued class report clearing deficiency. Verified on board by USCG MI.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 5 July 2017
Resolved
Chief Engineer requested parts to make repairs to leaking shaft seals from deficiency number 3 more than 6 months ago and has not received requeste parts. SOLAS IX/3.1 ISM Code 10.1 16ac
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 11 August 2017
Resolution: Vessel class issued class report clearing deficiency. Verified on board by USCG MI.
Pollution Prevention/Response › Prevention Equipment › Garbage Grinder/Comminuter
Issued 5 July 2017
Resolved
Garbage managment plan outdated, last revised in 2002 and does not reflect current MARPL regulations. Due to outdated plan ship has made multiple discharges of unground food waste within the Caribbean Special Area. MARPOL 73/78 Annex V/10.2 16ac
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 11 August 2017
Resolution: Vessel class issued class report clearing deficiency. Verified on board by USCG MI.
Lifesaving › Launching Appliances › Davit
Issued 21 December 2016
Resolved
0630 - The condition of the ship shall be maintained to conform with the present regulations. During inspection of lifeboats PSCO noted wastage and holing on the howizontal plates of all four lifeboat davit arms. Wastage did not appear to extend to perpendicular plates. Correct to satisfaction of RO. - SOLAS 74(2014) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 July 2017
Resolution: Vessel provided class report attesting to resolution.
Accommodation/Occupational Safety › Ventilation › General
Issued 21 December 2016
Resolved
0320 - The condition of the ship and its equipment shall be maintained to conform to the present regulations. PSCO observed a tarp covering wasted air conditioning ventilation duct adjacent to the stack on aft superstructure deck. Correct to satisfaction of RO. - SOLAS 74(14) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 July 2017
Resolution: Vessel provided class attestation showing resolution.
Lifesaving › Lifeboat Equipment › Rocket Parachute Flare
Issued 21 December 2016
Resolved
0611 - All the lifesaving appliances shall be kept in working order and available for immediate use. PSCO observed that all parachute flares in both lifeboats expired in November of 2016. Vessel submitted requisition in October but company has not provided new flares. - SOLAS 60 III/4.c
Action required: 705 - Other - as specified
Due 4 January 2017
Resolved 5 July 2017