MAURY USCG vessel records Sign in
← All vessels

CARIBE STAR

CARIBE STAR is a 1971 freight ship. The Coast Guard has recorded 70 inspections since 1998, most recently in August 2017, along with 130 deficiencies and 5 operational controls.

Records from 1998 to 2017. Most recent: inspection, 11 August 2017.

Built
1971
Last inspected
11 August 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7124104 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
483378
Flag
PANAMA
—
Maury page id
psix-483378

Inspections, by type

…with no type recorded34
Years with a record 17 calendar years (1998–2017)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it4071 - Convention (Subpart B), Gross Ton
1951 - Convention (Subpart B), Net Ton
6653 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 70

11 August 2017 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6235550
5 July 2017 Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6191941
21 December 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6058878
3 February 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5808580
27 July 2015 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5197431
28 June 2014 Ballast Water Examination · PI Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4900837
28 June 2014 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4902717
28 June 2014 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4902926
17 February 2012 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4246330
1 February 2012 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4236143
13 January 2009 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3393758
2 October 2008 PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3337386
25 February 2008 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3152918
11 February 2008 PI Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3145856
28 July 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3009604
11 April 2007 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2905953
12 September 2006 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2776119
6 June 2006 PII Safety Exam · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2666181
5 May 2006 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2636552
4 May 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2636948
14 March 2006 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2601714
17 January 2006 MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2565328
23 May 2005 ISPS II Exam · Ballast Water Examination · Spot Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2363540
21 May 2005 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2363963
17 March 2005 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2310510
2 March 2005 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2302332
20 January 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2277918
18 January 2005 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2276308
25 August 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2176379
27 July 2004 ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2146432
12 April 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2042625
11 March 2004 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2022603
9 March 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2021703
9 March 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2021762
4 February 2004 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2000270
24 November 2003 Administrative Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1953331
20 August 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1882800
28 July 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1859341
23 June 2003 Security Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1824367
7 April 2003 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1767580
19 March 2003 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1759515
25 February 2003 Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1752513
17 January 2003 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1731006
29 November 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1711228
4 August 2002 Administrative Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1654321
10 July 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1644306
17 June 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1631907
26 May 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1621059
12 April 2002 Periodic Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1604122
11 February 2002 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1485330
26 September 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 294070
8 September 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 293593
16 July 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 291969
10 April 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 288890
20 October 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 283232
25 July 2000 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 280217
9 July 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 279737
12 May 2000 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 277791
21 February 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 274973
2 February 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 274176
13 January 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 273680
15 November 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 435061
25 October 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 434028
5 October 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 433347
1 June 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 429215
23 March 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 426698
2 March 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 425992
10 February 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 425364
23 December 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 423908
9 October 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 420905

Deficiency record · 130

Lifesaving › Launching Appliances › Winch
Issued 5 July 2017 Resolved
Port side lifeboat recovery winch inoperable due to faulty switch. SOLAS I/11(b) 16ac
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 11 August 2017
Resolution: Vessel class issued class report clearing deficiency. Verified on board by USCG MI.
Construction/Loadline › Structures › Deck Plating
Issued 5 July 2017 Resolved
Wooden deck installed above welding shop area in midship superstructure posing fire hazard. SOLAS I/11(B) 16ac
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 11 August 2017
Resolution: Vessel class issued class report clearing deficiency. Verified on board by USCG MI.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 5 July 2017 Resolved
Main fire pump, ballast pump and ship's main shaft seal all excessively leaking. SOLAS I/11(b) 16ac
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 11 August 2017
Resolution: Vessel class issued class report clearing deficiency. Verified on board by USCG MI.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 5 July 2017 Resolved
Chief Engineer requested parts to make repairs to leaking shaft seals from deficiency number 3 more than 6 months ago and has not received requeste parts. SOLAS IX/3.1 ISM Code 10.1 16ac
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 11 August 2017
Resolution: Vessel class issued class report clearing deficiency. Verified on board by USCG MI.
Pollution Prevention/Response › Prevention Equipment › Garbage Grinder/Comminuter
Issued 5 July 2017 Resolved
Garbage managment plan outdated, last revised in 2002 and does not reflect current MARPL regulations. Due to outdated plan ship has made multiple discharges of unground food waste within the Caribbean Special Area. MARPOL 73/78 Annex V/10.2 16ac
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 11 August 2017
Resolution: Vessel class issued class report clearing deficiency. Verified on board by USCG MI.
Lifesaving › Launching Appliances › Davit
Issued 21 December 2016 Resolved
0630 - The condition of the ship shall be maintained to conform with the present regulations. During inspection of lifeboats PSCO noted wastage and holing on the howizontal plates of all four lifeboat davit arms. Wastage did not appear to extend to perpendicular plates. Correct to satisfaction of RO. - SOLAS 74(2014) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 July 2017
Resolution: Vessel provided class report attesting to resolution.
Accommodation/Occupational Safety › Ventilation › General
Issued 21 December 2016 Resolved
0320 - The condition of the ship and its equipment shall be maintained to conform to the present regulations. PSCO observed a tarp covering wasted air conditioning ventilation duct adjacent to the stack on aft superstructure deck. Correct to satisfaction of RO. - SOLAS 74(14) I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 July 2017
Resolution: Vessel provided class attestation showing resolution.
Lifesaving › Lifeboat Equipment › Rocket Parachute Flare
Issued 21 December 2016 Resolved
0611 - All the lifesaving appliances shall be kept in working order and available for immediate use. PSCO observed that all parachute flares in both lifeboats expired in November of 2016. Vessel submitted requisition in October but company has not provided new flares. - SOLAS 60 III/4.c
Action required: 705 - Other - as specified
Due 4 January 2017
Resolved 5 July 2017
Resolution: Vessel provided class attestation showing resolution.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 February 2012 Resolved
Observed Bouyant lines were missing from Lifebuoys. Improperly fitted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 February 2012
Resolved 17 February 2012
Resolution: Bouynat type life lines installed on vessels life buoys
Lifesaving › Lifeboat › Markings
Issued 11 February 2008 Resolved
There are no seat markings on Lifeboats. Crew has painted over them. Vessel is to repaint seat markings with in 30 days to the satisfaction of the administration.
Action required: 705 - Other - as specified
Due 11 March 2008
Resolved 2 October 2008
Resolution: Recieved class report attesting to proper repairs.
Fire Fighting › Fire Main › Condition
Issued 11 February 2008 Resolved
#2 G.S. Pump discharge piping on the output side is holed. Vessel is to make permanent repairs to the satisfaction of the administration.
Action required: 705 - Other - as specified
Due 11 March 2008
Resolved 2 October 2008
Resolution: Recieved class report attesting to proper repairs.
Fire Fighting › Fire Main › Pressure
Issued 11 February 2008 Resolved
No pressure relief device was installed on the fire main. Vessel is to repair or install a new pressure relieve device to the satisfaction of the Administration.
Action required: 705 - Other - as specified
Due 11 March 2008
Resolved 2 October 2008
Resolution: Recieved class report attesting to proper repairs.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 11 February 2008 Resolved
Emergency Fire pump oil leaks excessively. Vessel is to repair the leaks to the satisfaction of the Administration.
Action required: 705 - Other - as specified
Due 11 March 2008
Resolved 2 October 2008
Resolution: Recieved class report attesting to proper repairs.
Operations/Management › Drills/Instruction › Fire
Issued 7 June 2006 Resolved
Two attempts were made by USCG to conduct a fire drill. Attempt one failed due to lack of communication among crew and not following the fire safety plan. Crew failed to muster, was set up to fight fire without proper gear, and at the wrong location. Second attempt again proved the inability of the crew to muster properly and communicate the location of fire. To Class STCW 95 VI/1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2006
Resolution: Class conducted a satisfactory fire-fighting and abandon ship drills witnessed by the CG. Crew observed to be knowledgeable and proficient.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 June 2006 Resolved
Engine room had excessive oil leaking from main engine. Many rags and sponges were stuffed in random areas of the engine in order to soak up the oil. There were many buckets of oil under machinery and a large quantities of oil in the bilge. To the satisfaction of Class Solas 2004 I/11 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2006
Resolution: Class attested to the condition of the engine room and observed it to be dirty and in need of better housekeeping. Oily rags and sponges were removed. Bilges were sounded and inspected. Class deemed the engine room to be safe for voyage.
Fire Fighting › Fire Main › Condition
Issued 7 June 2006 Resolved
Anchor wash line running through the bosun stores had a severe leak. Crew stated the anchor wash line was a intregal part of the fire main system in order to prevent over presserizing. To the satisfaction of Class Solas 74 consolidated Ch. II-2/21
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2006
Resolution: Section of piping in Bosun''''s Store was replaced and inspected by Class but still had a small drip at the weld. USCG returned on 08 JUN 06 to re-inspect and found it to be leak free.
Fire Fighting › Fire Hoses › Connections
Issued 7 June 2006 Resolved
# 7 fire hose was missing the nozzle attachment. To the satisfaction of Class Solas 60 Ch. II/56 (f)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2006
Resolution: Class inspected and found the # 7 fire hose nozzle had been replaced.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 7 June 2006 Resolved
Port-side life-raft's hydro-static release assembly was not arranged properly. To the satisfaction of Class LSA Code 4.1.6.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2006
Resolution: Class attested to port-side life-raft’s release assembly in working order.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 7 June 2006 Resolved
Rudder order indicator at the helm was not in working order. To the satisfaction of Class 33 CFR 164.11 (r)
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Stability › Weathertight Integrity › General
Issued 7 June 2006 Resolved
There was a soft patch on the starboard side superstructure/life-boat deck. To the satisfaction of Class ICLL 66 Annex I Reg. 3/10 (b)
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 June 2006 Resolved
Deck safety chains under port and starboard life-boats were missing. To the satisfaction of Class ICLL 66 Annex I Reg. 25/2
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 June 2006 Resolved
Forward Starboard catwalk leading to top of cargo space has wasted section of plating. To the satisfaction of Class ICLL 66 Annex I Reg. 25
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Stability › Watertight Integrity › General
Issued 7 June 2006 Resolved
Starboard aft bulkhead for a/c space on life-boat deck had a large hole where it joined the deck. To the satisfaction of Class ICLL Annex I Reg. 3/10 (b)
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 7 June 2006 Resolved
Fuel oil containments on free-board deck and lower superstructure deck are missing containment plugs/scuppers. To the satisfaction of the Coast Guard 33 CFR 155.320
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Engineering › Steam Boiler (auxiliary/waste heat) › Feed pipe
Issued 7 June 2006 Resolved
Water pipe feeding the cascade tank was wasted. To the satisfaction of Class SOLAS 2004 II-1/26.1 (b) (1)
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 June 2006 Resolved
All lifebouys lack proper IMO markings. To the satisfaction of the Coast Guard 46 CFR 199.70 (a) (1 ) (iii)
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Operations/Management › Pollution › Control of Garbage
Issued 7 June 2006 Resolved
Garbage management plan was not being followed. Plastic was mixed with food and there were not enough receptacles. To the satisfaction of Class MARPOL 73/78 Annex V/9.2
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 7 June 2006 Resolved
Steam lines in a/c space were leaking and lacked lagging. To the satisfaction of Class SOLAS 2004 II-1/26
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Lifesaving › Buoyant Apparatus › Marking
Issued 7 June 2006 Resolved
SARTS not marked with vessel name. To the satisfaction of Coast Guard 46 CFR 199.60 (b)
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Lifesaving › Lifeboat Equipment › Boat Hook
Issued 7 June 2006 Resolved
Port-side life-boat is missing a boat hook. To the satisfaction of the Coast Guard LSA 2003 4.4.8.2
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Lifesaving › Lifeboat › Lifeline (becketed)
Issued 7 June 2006 Resolved
The life-line becketed on the port-side life-boat is wasted. To the satisfaction of the Coast Guard SOLAS 60 Ch. III/11 (a) viii
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Lifesaving › Lifeboat › Markings
Issued 7 June 2006 Resolved
Port and Starboard life-boats lack means of identifying the number of lifeboat which must be visable from above. To the satisfaction of the Coast Guard LSA 2003 4.4.9.3
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Engineering › Generator (propulsion-electric) › Measurement Circuitry
Issued 7 June 2006 Resolved
The reverse power relay glass gauge is broken on the number two generator panel in the engine control room. To the satisfaction of Class SOLAS Ch. II-1/26
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Engineering › Compressed Air System (control) › Compressor
Issued 7 June 2006 Resolved
The sight glass on the NO. 2 air compressor is broken. To the satisfaction of Class SOLAS 2004 Ch. II-1/26
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Engineering › Compressed Air System (control) › Compressor
Issued 7 June 2006 Resolved
Two sight glasses on NO. 1 air compressor are broken. To the satisfaction of Class SOLAS 2004 Ch. II-1/26
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 June 2006 Resolved
No protective shields on grinding wheels in the auxiliary shop. To the satisfaction of Class SOLAS 2004 Ch. II-1/26
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 June 2006 Resolved
There was no motor housing shield in the a/c space on the life boat deck. To the satisfaction of Class SOLAS 2004 Ch. II-1/26
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Electrical › Lighting (service) › Lighting Fixture
Issued 7 June 2006 Resolved
The light above cascade tank in engine room is cracked. To the satisfaction of Class SOLAS 60 Ch. II/27 (a) (i) (2)
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 7 June 2006 Resolved
# 3 generator's vertical piping has a soft patch. To the satisfaction of Class SOLAS 2004 Ch. II-1/26.3.1
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 7 June 2006 Resolved
The sewage D.CA and D.CB site glass is cracked. To the satisfaction of Class SOLAS 2004 Ch. II-1/26.3.1
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 June 2006 Resolved
Guard rail missing on 2nd deck of the engine room on port-side by the stairs. To the satisfaction of Class ICLL 66 Annex 1 reg. 25/4
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Fire Fighting › Fire Hoses › Location
Issued 7 June 2006 Resolved
Fire hose # 14 on lower deck of engine room was missing. To the satisfaction of Class SOLAS 1974 Ch. II-11/21
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 June 2006 Resolved
Broken railing on starboard-side near # 3 fuel oil vent. To the satisfaction of Class ICLL 66 Annex I Reg. 15.
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 June 2006 Resolved
Non conductive matting is missing in front of all electrical panels in cargo control room and in cargo spaces. To the satisfaction of Class. SOLAS 60 Ch. II/27 (a) (i) 2
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Construction/Loadline › Hull › Side Shell
Issued 7 June 2006 Resolved
6 Foot wide by 6 inch deep inset on the starboard side of the hull, slightly aft of the load-line mark. To the satisfaction of Class ICLL Annex I Reg 1
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 June 2006 Resolved
There was a buckled rib in cargo spaces starboard-side of hull near compressor. To the satisfaction of Class ICLL 66 Annex I Ch. I Reg. 1
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 7 June 2006 Resolved
Fire extinguishers on vessel were not properly classified. To the satisfaction of Class FSS A.602 (15) 8
Due 22 June 2006
Resolved 11 September 2006
Resolution: def corrected
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 June 2006 Resolved
No motor housing shield in starboard-side life boat. To the satisfaction of Class SOLAS 2004 Ch. II-1/26
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Lifesaving › Lifeboat › Seating
Issued 7 June 2006 Resolved
Center support for sail mast on port-side life-boat is wasted. To the satisfaction of Class Solas 60 Ch. III/5 (a)
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 7 June 2006 Resolved
Main engine lube oil pump has 2 broken gauges. To the satisfaction of Class SOLAS 2004 Ch. II-1/26
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Communications › Radio Communications › EPIRB
Issued 6 June 2006 Resolved
EPIRB's were not marked with vessel name. To the satisfaction of the Coast Guard 46 CFR 199.60 (b)
Action required: 15 - Rectify deficiencies by next port
Resolved 11 September 2006
Resolution: def corrected
Construction/Loadline › Penetrations › Gasket
Issued 5 May 2006 Resolved
Gaskets on doors 180, 113, and 109 are deformed/ not water tight. ICLL 66 1/12
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2006
Resolved 6 May 2006
Resolution: Received tech. report via fax from class surveyor attesting to the correct working order of the water tight gaskets.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 5 May 2006 Resolved
Deck scuppers not in place. 33 CFR 155.310(a)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 5 May 2006
Resolution: Deck scuppers replaced on the spot.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 5 May 2006 Resolved
All drains not plugged on discharge containment under fuel oil vents.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 5 May 2006
Resolution: All drains plugged.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 14 March 2006 Resolved
Deck scuppers are made of cement. Must be fixed prior to next U.S. port after sailing foriegn to the satisfaction of the Coast Guard. 33CFR155.310(a)(3)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2006
Resolution: Deck scuppers replaced.
Construction/Loadline › Structures › Superstructure
Issued 14 March 2006 Resolved
Two broken rungs on steps aft of the main deck. Must be fixed prior to next U.S. port after sailing foriegn to the satisfaction of the Coast Guard. ICLL 66 Annex I/13
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2006
Resolution: Broken rungs replaced.
Construction/Loadline › Structures › Superstructure
Issued 14 March 2006 Resolved
Support brackets for railing is missing on top of compressor room. Must be fixed prior to next U.S. port after sailing foriegn to the satisfaction of the Coast Guard. ICLL 66 Annex I/13
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2006
Resolution: Support brackets replaced.
Construction/Loadline › Penetrations › Gasket
Issued 14 March 2006 Resolved
Gasket around the door heading into the compressor is loose. Must be fixed prior to next U.S. port after sailing foriegn to the satisfaction of the Coast Guard. ICLL 66 Annex I/12
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2006
Resolution: Gasket around door replaced.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 14 March 2006 Resolved
Rudder on port life boat damaged while testing the limit switch. Must be fixed prior to next U.S. port after sailing foriegn to the satisfaction of the Coast Guard. SOLAS 60 III/11
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2006
Resolution: Rudder replaced.
Operations/Management › Pollution › Arrival Reporting, Garbage
Issued 14 March 2006 Resolved
Receipt not obtained from reception facility for garbage discharged on 04 MAR 06 I.A.W. Garbage Management Plan. Must be fixed prior to next U.S. port after sailing foriegn to the satisfaction of the Coast Guard. MARPOL Annex V/9.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2006
Resolution: Obtained reciept from reception facility.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 14 March 2006 Resolved
Garbage not seperated properly. Must be fixed prior to next U.S. port after sailing foriegn to the satisfaction of the Coast Guard. MARPOL Annex V/9.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 May 2006
Resolution: Garbage sorted properly.
Construction/Loadline › Structures › Door
Issued 17 January 2006 Resolved
All weather tight door gaskets on weather decks not installed correctly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 14 March 2006
Resolution: All weather tight door gaskets on weather decks installed correctly.
Construction/Loadline › Structures › End Bulkhead
Issued 17 January 2006 Resolved
Guard rails missing on top of compressor room.
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 14 March 2006
Resolution: Guard rails replaced.
Construction/Loadline › Structures › Superstructure
Issued 17 January 2006 Resolved
Navigation mast and catwalk has excessive patching and deterioration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 14 March 2006
Resolution: Mast and catwalk ok.
Construction/Loadline › Structures › Superstructure
Issued 17 January 2006 Resolved
Safety chains missing on top of compressor room.
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 14 March 2006
Resolution: Safety chains replaced.
Construction/Loadline › Structures › Ventilators
Issued 17 January 2006 Resolved
Vent cover on fan leading into compressor room.
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 14 March 2006
Resolution: Vent cover replaced.
Fire Fighting › Portable Foam Applicators › General
Issued 17 January 2006 Resolved
#15 and #16 ABC fire extinguishers not charged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 14 March 2006
Resolution: Fire extinguishers properly charged.
Electrical › Mast › Lightning Ground
Issued 17 January 2006 Resolved
Electrical wiring on mast exposed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 14 March 2006
Resolution: Electrical wiring fixed.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 17 January 2006 Resolved
Non conductive mats missing in engine controll room.
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 14 March 2006
Resolution: Non conductive mats placed in engine control room.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 17 January 2006 Resolved
Safety limit switch for the port life boat inoperable.
Action required: 705 - Other - as specified
Due 17 February 2006
Resolved 14 March 2006
Resolution: Limit switch opperational
Operations/Management › Pollution › Control of Garbage
Issued 18 January 2005 Resolved
Vessel is burning oily rags and plastics in a 55 gallon drum on the fantail. Have class attest to the removal of the 55 gallon drum prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS.
Operations/Management › Drills/Instruction › Fire
Issued 18 January 2005 Resolved
Fire drill unsatisfactory. Port State to witness a satisfactory fire drill before depature.
Action required: 705 - Other - as specified
Resolved 25 January 2005
Resolution: Conducted satisfactory fire drill in the ship''s galley.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 18 January 2005 Resolved
Rudder angle indicator on steering gear not reading same on bridge, approximately 6 degrees difference.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 18 January 2005 Resolved
Vessel does not have a ballast water management plan on board.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 March 2005
Resolution: Received Lloyds Register report dated 24FEB05 attesting to availability of BWM plan and its implementation.
Engineering › Steam System (main) › Valve, Relief
Issued 18 January 2005 Resolved
High pressure relief and standard valve leaking steam on the L/O heating system. Have class attest to proper repairs prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS.
Engineering › Feedwater/Condensate Water System › Piping
Issued 18 January 2005 Resolved
Overboard discharge pipe for the water heater has a doubler on it. Have class attest that the repair is satisfactory prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 January 2005 Resolved
Starboard side catwalk in engine room brackets need to be repaired. Bracket under deck plates starboard side need to be replaced. Have class attest to the condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS.
Fire Fighting › Fire Main › Condition
Issued 18 January 2005 Resolved
Main fire pump has excessive leakage from packing gland. Have class attest to the proper repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS.
Engineering › Lubricating Oil Service System › Piping
Issued 18 January 2005 Resolved
Main engine has excessive leaking at various external tubing points. Have class attest to the condition of main engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 18 January 2005 Resolved
No containment around sludge tank vent on port side aft, and no containment around L/O tank vent on starboard side aft. Have class attest to proper installation of containment means.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS.
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 18 January 2005 Resolved
Galley has an infestation. Vessel is to provide proof that an exterminator has serviced the galley and accompanied spaces.
Due 18 February 2005
Resolved 17 March 2005
Resolution: Received Lloyds Register report dated 24FEB05 attesting to fumigation of galley.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 18 January 2005 Resolved
[name withheld], Chief engineer, Second officer, and Second engineer do not have valid Columbian national licenses on board. Have flag state administration provide letter attesting to validication of Panamanian licenses with Columbian training certificates.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2005
Resolution: RECEIVED VERIFICATION FROM PANAMANIAN MARITIME AUTHORITY.
Operations/Management › Vessel Traffic Service › Reporting Requirements
Issued 18 January 2005 Resolved
Vessel failed to provide correct classification society on several Notice of Arrivals.
Action required: 705 - Other - as specified
Due 20 January 2005
Resolved 17 March 2005
Resolution: NOA satisfactory for this port of call.
Fire Fighting › Emergency Fire Pumps
Issued 11 March 2004 Resolved
Fuel oil leak on emergency fire pump drive motor. Solas 60 CH.I/REG.11 LEGACY COMPONENT DESC: Arrangement
Action required: 15 - Rectify deficiencies by next port
Due 12 April 2004
Resolved 12 April 2004
Resolution: Received class report attesting to repairs
Fire Fighting › Emergency Fire Pumps
Issued 11 March 2004 Resolved
Cooling water leak on emergency fire pump drive motor and drive shaft. Soals 60 CH. I/REG11
Action required: 15 - Rectify deficiencies by next port
Due 12 April 2004
Resolved 12 April 2004
Resolution: Received class report attesting to repairs
Engineering › Lubricating Oil Service System
Issued 11 March 2004 Resolved
Salt water inlet for lube oil cooler holed and leaking. Solas 60 CH.I/ REG11 LEGACY COMPONENT DESC: Cooler
Action required: 15 - Rectify deficiencies by next port
Due 12 April 2004
Resolved 12 April 2004
Resolution: Received class report attesting to repairs
Engineering › Sea-water System (primary cooling)
Issued 11 March 2004 Resolved
Salt water outlet piping for Main engine cooler holed and leaking. Solas 60 CHI/ Reg11 LEGACY COMPONENT DESC: Piping
Action required: 15 - Rectify deficiencies by next port
Due 12 April 2004
Resolved 12 April 2004
Resolution: Received class report attesting to repairs
Engineering
Issued 11 March 2004 Resolved
Make permanent repairs to temporary polymer patch on ballast water piping for forward deep tank. Solas 60 CHI/REG11
Action required: 15 - Rectify deficiencies by next port
Due 12 April 2004
Resolved 12 April 2004
Resolution: Received class report attesting to repairs
Engineering › Diesel Engine (propulsion-direct drive)
Issued 11 March 2004 Resolved
Make permanent repairs to temp patch on main engine air scavenger. Soals 60 CH.I/REG.11
Action required: 15 - Rectify deficiencies by next port
Due 12 April 2004
Resolved 12 April 2004
Resolution: Received class report attesting to repairs
Engineering › Freshwater Generation System
Issued 11 March 2004 Resolved
Fresh water generator cooler salt water outlet pipe holed and leaking. Solas 60 CH.1/ REG.11 LEGACY COMPONENT DESC: Piping
Action required: 15 - Rectify deficiencies by next port
Due 12 April 2004
Resolved 12 April 2004
Resolution: Received class report attesting to repairs
Engineering › Generator (propulsion/auxiliary-electric)
Issued 11 March 2004 Resolved
#3 Generator missing machinery guard. Solas 74 Amended CH.II-1/26.1
Action required: 15 - Rectify deficiencies by next port
Due 12 April 2004
Resolved 12 April 2004
Resolution: Received class report attesting to repairs
Engineering › Freshwater System (jacketwater cooling)
Issued 11 March 2004 Resolved
#1 Generator has cooling water leak. Solas 60 CHI/ REG 11
Action required: 15 - Rectify deficiencies by next port
Due 12 April 2004
Resolved 12 April 2004
Resolution: Received class report attesting to repairs
Accommodation/Occupational Safety › Medical/First Aid
Issued 25 February 2003 Resolved
Provide & Designate hospital space on board. LEGACY COMPONENT DESC: Hospital Space
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2003
Resolved 26 February 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 25 February 2003 Resolved
Provide operable toilet in vicinity of Hospital space. LEGACY COMPONENT DESC: Hospital Space
Action required: 705 - Other - as specified
Due 25 March 2003
Resolved 7 April 2003
Resolution: Toilet near hospital provided and operational.
Fire Fighting › Nozzles
Issued 25 February 2003 Resolved
Provide multi-purpose & spanners for each station.
Action required: 15 - Rectify deficiencies by next port
Due 26 March 2003
Resolved 19 March 2003
Resolution: Multi-purpose nozzles and spanner wrenches have been procured and placed in service at each fire station onboard.
Electrical › Lighting (emergency)
Issued 25 February 2003 Resolved
Provide Globes & Guards for light fixtures throughout vessel. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 15 - Rectify deficiencies by next port
Due 26 February 2003
Resolved 19 March 2003
Resolution: Globes/Guards have been installed on light fixtures.
Accommodation/Occupational Safety › Heating
Issued 17 January 2003 Resolved
Hot water on vessel inoperable. ILO 147. Install sufficient size water heater.
Due 1 March 2003
Resolved 25 February 2003
Navigation › Piloting/Steering › Gyro Compass
Issued 4 August 2002 Resolved
Vsl was issued a Letter of Deviation to enter the Port of Corpus Christi with an inoperable gyrocompass (33 CFR 164.35(d))
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2002
Resolution: Rec''d fax from Radio-Holland (dated 3 AUG 02) attesting to satisfactory repairs and proper operation of the gyrocompass. USCG inspectors boarded the vsl 4 AUG 02 and found the gyrocompass to be in proper operating condition.
Personnel › Certificates/Documents/Licenses
Issued 17 April 2002 Resolved
Issued STCW warning letter due to ship and/or crew not being in compliance with one or more or the provisions of STCW 1978 as amended 1995. LEGACY COMPONENT DESC: STCW Endorsement
Due 1 August 2002
Resolved 4 August 2002
Resolution: All licenses inspected and found to be in compliance.
Fire Fighting
Issued 8 September 2001 Resolved
SMALL HOLE IN FIREMAIN PORT SIDE 3 FEET AFT OF FOCSLE.
Condition: Unknown
Due 26 September 2001
Resolved 26 September 2001
Electrical
Issued 20 October 2000 Resolved
PROVIDE RUBBER MATS IN EC ROOM._x001C_ SOLAS CHAP II-1 REG 41
Condition: Unknown
Due 13 November 2000
Resolved 13 November 2000
Electrical
Issued 20 October 2000 Resolved
PROVIDE COVERS FOR ELECTRICAL BOXES IN TOOL ROOM._x001C_ SOLAS CHAP. II-1 REG 45
Condition: Unknown
Due 13 November 2000
Resolved 13 November 2000
Electrical
Issued 20 October 2000 Resolved
Repair fuel leak on #2 generator._x001C_ SOLAS Chap. II-1 Reg 26
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Electrical
Issued 20 October 2000 Resolved
Repair salt water cooling pipe leaks on both s/s generator. _x001C_ SOLAS Chap. II-1 Reg 26
Condition: Unknown
Due 27 October 2000
Resolved 27 October 2000
Fire Fighting
Issued 20 October 2000 Resolved
Replace packing to #1 fire pump._x001C_ SOLAS Chap. II-2 Reg 4
Condition: Unknown
Due 13 November 2000
Resolved 13 November 2000
Engineering
Issued 20 October 2000 Resolved
Make permanent repairs to soft patch on piping E/R lower level & upper level._x001C_ SOLAS Chap. II-1 Reg 26
Condition: Unknown
Due 13 November 2000
Resolved 13 November 2000
Electrical
Issued 20 October 2000 Resolved
REPLACE RPM & FUEL GAUGES ON #1 S/S GENERATOR._x001C_ SOLAS CHAP. II-1 REG 31
Condition: Unknown
Due 13 November 2000
Resolved 13 November 2000
Engineering
Issued 20 October 2000 Resolved
REPAIR BOILER VALVES & HANDLES._x001C_ SOLAS CHAP. II-1 REG 32
Condition: Unknown
Due 13 November 2000
Resolved 13 November 2000
Electrical
Issued 20 October 2000 Resolved
REPLACE BOILER AND #1 GENERATOR EXHAUST BELLOWS._x001C_ SOLAS CHAP. II-1 REG 32
Condition: Unknown
Due 13 November 2000
Resolved 13 November 2000
Electrical
Issued 20 October 2000 Resolved
PROVIDE JUNCTION BOXES FOR WIRE SPLICES IN REEFER AREA._x001C_ SOLAS CHAP. II-1 REG 40
Condition: Unknown
Due 13 November 2000
Resolved 13 November 2000
Navigation
Issued 9 July 2000 Resolved
AMEND EMERGENCY STEERING INSTRUCTIONS TO REFLECT PROPER METHOD AND PROVE ITS PROPER OPERATION TO THE ATTENDING USCG MARINE INSPECTOR. _x001C_ SOLAS 60-II/29
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Construction/Loadline
Issued 5 October 1999 Resolved
COMPRESSOR ROOM VENT CLOSURE CORRODED_x001C_ ---SOLAS 60 I-II / SOLAS 74(amended) III/29---
Condition: Unknown
Due 26 October 1999
Resolved 26 October 1999
Lifesaving
Issued 5 October 1999 Resolved
STBD LIFEBOAT CUTLASS BEARING SLIPING OUT OF STEARN TUBE._x001C_ ---SOLAS 60 I REG II---
Condition: Unknown
Due 26 October 1999
Resolved 26 October 1999
Electrical
Issued 5 October 1999 Resolved
Engineroom skylight hatch corroded-gasket warped-will not seal_x001C_ ---Solas 60 I-II---
Condition: Unknown
Due 26 October 1999
Resolved 26 October 1999
Lifesaving
Issued 5 October 1999 Resolved
STBD LIFERAFT MISSING WEAK LINK-IMPROPER HYDROSTATIC RELEASE._x001C_
Condition: Unknown
Due 5 October 1999
Resolved 7 October 1999
Lifesaving
Issued 5 October 1999 Resolved
ALL SUPERSTRUCTURE DOORS ARE LOCKED FROM THE INSIDE._x001C_ ---SOLAS 60---
Condition: Unknown
Due 26 October 1999
Resolved 26 October 1999
Unknown
Issued 10 February 1999 Resolved
Air condition cooling pump leaking exessive water into the bilges.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Accommodation/Occupational Safety
Issued 10 February 1999 Resolved
Habitable conditions, Toilets are missing toilet seats and toilets are not flushing properly._x001C_ --ILO-147--
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Documentation
Issued 10 February 1999 Resolved
Garbage log not indicating CAT-1 plastics are being discharged to a reception facility._x001C_ --MARPOL ANNEX V--
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Documentation
Issued 10 February 1999 Resolved
Garbage Management Plan not in working language of crew._x001C_ -- Marpol 73/78 Annex V/9 (Sept 95 amendment)--
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Accommodation/Occupational Safety
Issued 10 February 1999 Resolved
Guard rail in port side main deck broken at base next to superstructure andanother on the 03 deck port side stack._x001C_ --I.C. L.L.-CHII-REG 25(2)--
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Accommodation/Occupational Safety
Issued 10 February 1999 Resolved
MSD inoperable, flushed a toilet and water came up not down._x001C_ --33 CFR 159.7 (a) , MARPOL 73/78 Annex IV/3(I)
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Engineering
Issued 9 October 1998 Resolved
Remove rubber hose from lube oil hand pump on starboard side._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Electrical
Issued 9 October 1998 Resolved
Permanently mount light fixtures in bos'n stores or install fire proof safety chains._x001C_ _x001C_
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Construction/Loadline
Issued 9 October 1998 Resolved
Make permanent repairs to the aft hatch cover on the main deck._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Fire Fighting
Issued 9 October 1998 Resolved
Properly label all fire control plans to show the location of the fireman'soutfits. Prior to entering next U.S. port._x001C_ _x001C_
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Lifesaving
Issued 9 October 1998 Resolved
Make permanent repairs to the fracture on the starboard side of the port lifeboat._x001C_ _x001C_
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Documentation
Issued 9 October 1998 Resolved
Provide flag state approval for SOPEP. Prior to departure._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Engineering
Issued 9 October 1998 Resolved
Remove rubber hose from salt water cooling line leading to shaft._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Electrical
Issued 9 October 1998 Resolved
Make permanent repairs to salt water cooling line leading to #1 ship's service generator._x001C_ _x001C_
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998

Ownership record