Documentation record
Registered dimensions (L × B × D)64.8 ft × 20.0 ft × 5.0 ft
Registered tonnagegross 75 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHULLS UNLTD/MILLERS MARIN · DELTAVILLE, VA, UNITED STATES · built 1975
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, rec
DocumentationExpired · issued 30 June 2004
Service, as the file records itPublic Vessel, Unclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it75 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 11 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 11
7 May 2026
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8368541
7 March 2025
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8082817
10 June 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7932947
18 January 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7851152
8 June 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7790523
8 June 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7472991
5 January 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7385676
8 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7219836
3 May 2019
COI Inspection · Simplified Stability Test · Administrative Inspection · Construction Oversight · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6754401
22 November 2016
Initial Certification · Plan Review "T" Boat
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6046114
9 August 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5967436
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 March 2025
Resolved
FCC Safety Certificate was expired, provide vessel with valid certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2025
Resolution: Received copy of valid FCC safety cert.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 March 2025
Resolved
VHF DSC radio does not display GPS information, provide radio with GPS input to enable DSC function.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2025
Resolution: Received photo of lat/long displayed on VHF radio.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2024
Resolved
Observed lifebuoy's reflective tape peeling off. Replace reflective taping with type 1.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2024
Resolution: Vessel replaced ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2024
Resolved
Observed lifebuoy's float light is expired. Replace life float light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2024
Resolution: Vessel replaced life float light.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 June 2022
Resolved
Manually operated port side E/R vent closure failed to properly seal during operational test. Provide proposal and repair to ensure ventilation can be secured during a fire.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2022
Resolved 10 June 2024
Resolution: properly repaired and added seal around all edges
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2022
Resolved
only 01 lifejacket stowage location was found properly marked during inspection. Mark all stowage locations of lifejackets appropriately.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 10 June 2024
Resolution: Observed labels for each storage location for lifejackets
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 8 June 2021
Resolved
Maintenance service records for portable and fixed firefighting equipment was expired as of february 2021.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 16 June 2021
Resolution: Received firefighting servicing report satisfying deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 June 2021
Resolved
FIre Pump discharge gauge at 40-45 PSI during fire pump operation.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 December 2021
Resolution: Observed fire pump operation and discharge PSI @ 72 PSI; Def corrected. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 June 2021
Resolved
First Aid kit expired on 04/2021.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 9 July 2021
Resolution: Received documentation of corrected Def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 June 2021
Resolved
Provide a suitable length of hose for the portable hand bilge pump to discharge water directly overboard from any watertight compartment.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 9 July 2021
Resolution: Received documentation of corrected Def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 June 2021
Resolved
Vessel unable to draw bilge suction from forepeak space.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 9 July 2021
Resolution: Deficiency corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 June 2021
Resolved
Engine room vent dampners were obstructed from being closed. Provide proper arrangement for opening and closeing of dampners.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 9 July 2021
Resolution: Deficiency corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 June 2021
Resolved
Top deck max passenger count not listed on placard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 9 July 2021
Resolution: Corrected deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2021
Resolved
Missing 60 adult life preservers in vessel's inventory of 120
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 14 September 2021
Resolution: Verified 100 adult and 10 child life jackets in inventory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2020
Resolved
All vessel electrical switchboards must be compliant with marine safety standards. There were openings on the face board that need to be blanked off. Must make corrections to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2020
Resolved 9 April 2020
Resolution: email pic proof sent to attending [name withheld]4 Mosley
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 March 2020
Resolved
Bilge pump system must be fully operational. Suction to the sewage tank space was not working when pump was activated. Must make pump system fully operational to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2020
Resolved 22 July 2020
Resolution: Video sent via email to attending [name withheld]4 Mosley
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2020
Resolved
All life jackets must be labeled with the vessel name. Less than 10 life jackets were properly labeled. Deficiency must be corrected to the satisfaction of the CG Marine Inspector.
Action required: 705 - Other - as specified
Due 11 April 2020
Resolved 14 August 2020
Resolution: Must rectify prior to carriage of passengers. [name withheld] labeling to satisfaction of MI
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2020
Resolved
A total of 63 adult life jackets and 6 child life jackets were available for inspection. Vessel passenger count is reduced to 63 passengers (6 children ) until additional approved life jackets are provided to the satisfaction of the CG Marine Inspector.
Action required: 705 - Other - as specified
Due 11 April 2020
Resolved 10 June 2024
Resolution: Vessel passenger count has been reduced to 63 adult and 6 child passengers unitl additional life jackets is provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 March 2020
Resolved
All life buoys must be marked with Type II retro reflective material approved in accordance with 46 CFR 164.018. Life buoy on board vessel was not marked with retro reflective material in accordance with regulations and must be marked to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2020
Resolved 12 March 2020
Resolution: Vessel operator sent photo proof of correction of the def. [name withheld]