MAURY USCG vessel records Sign in
← All vessels

OCEAN PRINCESS

OCEAN PRINCESS is a 1975 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1985, most recently in May 2026, along with 145 deficiencies and 1 casualty investigation in 2017.

Records from 1985 to 2026. Most recent: inspection, 14 May 2026.

Built
1975
Last inspected
14 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB8212
Flag
UNITED STATES
366954840
Maury page id
psix-48349

Inspections, by type

…with no type recorded7
Years with a record 40 calendar years (1985–2026)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)70.5 ft × 21.4 ft × 7.2 ft
Registered tonnagegross 85 / net 68
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT LEON SHERBERT · PONCE INLET, FL, UNITED STATES · built 1975
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portOCEAN CITY, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it85 - Regulatory (Subpart C or D), Gross Ton
68 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB8212MMSI 366954840 · active · compulsorily equipped · granted 13 March 2024, expires 8 June 2034
WDA3368MMSI 366797650 · expired · compulsorily equipped · granted 19 January 2001, cancelled 26 March 2011 · licensed under a name not among this hull’s recorded names (not shown)
WTS9701MMSI not assigned · expired · compulsorily equipped · granted 12 November 1996, cancelled 14 April 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 79

14 May 2026 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8375423
14 May 2025 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8142277
13 February 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8080796
22 April 2024 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7897184
12 June 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7734672
15 February 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7636447
22 June 2022 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7476665
25 February 2022 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7402065
26 July 2021 Annual Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7282890
12 February 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7141151
20 July 2020 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7026074
30 April 2019 DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6674513
27 February 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6638654
30 July 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6511640
4 August 2017 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6255431
16 May 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6152443
16 May 2017 DAPI Audit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6154144
5 May 2017 Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6139506
7 April 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6126493
27 June 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6036996
15 August 2015 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5218942
5 May 2014 COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4841596
1 May 2012 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4299810
14 December 2011 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4304630
24 February 2011 Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3947030
29 April 2009 Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3458271
2 June 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3447157
15 May 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3205641
23 May 2007 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2944768
30 April 2007 Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2921277
24 April 2006 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2632057
10 April 2006 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2616550
12 May 2005 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2355624
12 April 2005 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2329299
29 March 2005 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2319314
7 May 2004 Annual Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2062056
19 May 2003 Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1796409
27 March 2003 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1760711
14 March 2002 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1493574
31 May 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1408750
3 April 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1059894
1 February 2000 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 814620
14 December 1999 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1399252
14 December 1999 Plan Review "T" Boat · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1403304
27 July 1999 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1106462
30 June 1999 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1440155
4 January 1999 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1406410
27 January 1998 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1117744
8 December 1997 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1451250
25 August 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1120164
25 July 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1117109
30 June 1997 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 780561
17 December 1996 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1095196
20 December 1995 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 880456
13 December 1995 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1193710
11 December 1995 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1188533
6 January 1995 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 857574
27 December 1994 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1159737
3 January 1994 COI Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 851090
4 November 1993 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 830436
25 March 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1149410
19 February 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 835739
5 January 1993 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1138553
14 April 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1254470
7 January 1992 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1265350
31 October 1991 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 952780
15 July 1991 Drydock Extension
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 937670
14 January 1991 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1233474
21 March 1990 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1212940
8 February 1990 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1218061
17 January 1990 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 928289
7 February 1989 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1342842
20 September 1988 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1353152
5 February 1988 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1326426
7 October 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1320262
4 March 1987 COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1016441
19 March 1986 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 991707
29 October 1985 Credit Drydock
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 993366
26 March 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 983341

Deficiency record · 145

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 April 2024 Resolved
46 CFR 181.310(c) Spanner wrenches must be provided where 1.5 inch diameter fire hose is required by 181.320(b). Vessel is missing spanner wrenches for fire hose stations.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 May 2024
Resolution: O/O Procured spanner wrench
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 April 2024 Resolved
46 CFR 180.210(a) A vessel of more than 65 feet in length must carry at least one rescue boat unless the cognizant OCMI determines that: (1) The vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water: The vessel's rescue ladder had corroded attachment chains and carabiner. Replace with fittings that exceed weight capacity for 02 persons.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 May 2024
Resolution: Chains and hardware have been replaced with WLL 738 lbs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2024 Resolved
46 CFR 182.520(e)(7) A positive shutoff valve is installed at the hull penetration Submersible electric bilge pump was missing shutoff valve at the hull.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 May 2024
Resolution: Positive shutoff valve installed at bulkhead
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 February 2023 Resolved
Marine inspectors shall inspect all railings and bulwarks and their attachment to the hull structure. On the vessel's top deck the railing is unattached from the stiffener in one location and cracked in another. 46 CFR176.802
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2023
Resolved 14 May 2025
Resolution: Resolved during annual inspection.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 7 April 2017 Resolved
Provide/Submit plans for new air conditioning system installation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 1 May 2017
Resolution: Plans & information submitted. Plans approved.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 5 May 2014 Resolved
Provide two additional adult life jackets w/lights and marked with vessel name.
Action required: 705 - Other - as specified
Due 20 May 2014
Resolved 20 May 2014
Documentation › Logs/Records › Logbook (official)
Issued 5 May 2014 Resolved
Provide vessel logbook, Ttaining log, and lifesaving maintenance log.
Action required: 705 - Other - as specified
Due 20 May 2014
Resolved 20 May 2014
Lifesaving › Lifefloat › Markings
Issued 5 May 2014 Resolved
Re-label lifefloats with vessel name and persons capacity.
Action required: 705 - Other - as specified
Due 20 May 2014
Resolved 20 May 2014
Lifesaving › Lifefloat › Lifeline
Issued 17 May 2012 Resolved
Lifeline and retro-reflective tape is wasted on aft bottom lifefloat. Vsl will remove this lifefloat until properly repaired. Vsl maintains 4 additional lifefloats that meet the required primary lifesaving requirements.
Action required: 705 - Other - as specified
Due 31 May 2012
Resolved 31 May 2012
Resolution: Vessel repaired lifefloat IAW manufacturer''s instructions and replaced retro-reflective tape. Lifefloat was placed back in service.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 May 2012 Resolved
Vessel is missing 06 adult lifejackets and 02 lifejackets. Vessel is restricted to 60 paxs and 03 crewmembers until new lifejackets are provided.
Action required: 705 - Other - as specified
Due 31 May 2012
Resolved 31 May 2012
Resolution: Vessel replaced all missing lifejackets. Vessel is able to operate at capacity IAW COI.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 May 2012 Resolved
Ring buoy on top deck had wasted lifeline. Vsl replaced lifeline with a yellow buoyant line, which does not meet the regulation of a line that is dark in color. Vsl will need to provide new lifeline IAW 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 31 May 2012
Resolved 31 May 2012
Resolution: Replaced lifeline with one that is a black synthetic line.
Lifesaving › Lifefloat › Serviceable
Issued 17 May 2012 Resolved
All lifefloats have portions that are damaged and could lead to water intrusion. Vsl owner will repair all affected areas of lifefloats IAW manufacturer's instructions.
Action required: 705 - Other - as specified
Due 31 May 2012
Resolved 31 May 2012
Resolution: Repaired all lifefloats IAW manufacturer''s instructions.
Construction/Loadline › Hull › Hull Plating
Issued 24 February 2011 Resolved
Vsl must perform an underway checkride prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 March 2011
Resolution: Attended vessel in the water in Ocean City, MD. All Sat.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 15 May 2008 Resolved
Provide protective covering for distribution panel on the bridge.
Action required: 705 - Other - as specified
Due 16 June 2008
Resolved 2 June 2008
Resolution: Distribution panel covering installed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 15 May 2008 Resolved
Repair exposed lagging on exhaust pipe.
Action required: 705 - Other - as specified
Due 16 June 2008
Resolved 2 June 2008
Resolution: Repair sat.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 May 2008 Resolved
Provide three additional life jackets prior to sailing with maximum amount of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2008
Resolution: Life jackets purchased.
Fire Fighting › Firemans Outfit › Axe
Issued 15 May 2008 Resolved
Stencil and mount fire axe at operating station.
Action required: 705 - Other - as specified
Due 16 June 2008
Resolved 5 May 2017
Resolution: Fire ax mounted.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 May 2008 Resolved
Provide 3 alcohol testing kits.
Action required: 705 - Other - as specified
Due 16 June 2008
Resolved 2 June 2008
Resolution: Tests provided.
Engineering › Fuel Oil Service System › Tank
Issued 30 April 2007 Resolved
Remove pitted areas on starboard fuel tank aft, conduct internal visual inspection, replace with original scantling, pressure test or replace fuel tank entirely.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 13 May 2009
Resolution: Master made repairs to fuel tank. Marine inspector visually inspected tank; all sat.
Lifesaving › Lifebuoys › Serviceable
Issued 30 April 2007 Resolved
Replace or recondition faded aft life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2009
Resolution: Replaced aft life ring.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 10 April 2006 Resolved
Provide brackets for all portable fire extinguishers with-in 7 days.
Condition: Unknown
Due 17 April 2006
Resolved 24 April 2006
Resolution: Vessel provided proof of brackets for portable fire extinguishers as required.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 April 2006 Resolved
Provide proof of fixed fire/portable fire extinguisher servicing as required.
Due 24 April 2006
Resolved 24 April 2006
Resolution: Vessel provided proof of servicing as required.
Communications › Audible Communications › Bell
Issued 10 April 2006 Resolved
Provide 300mm bell as required by 33 CFR part 86.
Condition: Unknown
Due 24 April 2006
Resolved 24 April 2006
Resolution: Vessel provided proof of 300mm bell.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 April 2006 Resolved
Provide retro reflective material to equal 31 square inches each side of 12 life jackets.
Condition: Improper Installation
Due 17 April 2006
Resolved 24 April 2006
Resolution: Provided proof of Retro reflective material.
Lifesaving › Lifeboat › Hull
Issued 12 April 2005 Resolved
Replace 15 man lifeboat, due to holes in Hull.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2005
Resolution: Replaced lifeboat with used serviceable 22 man lifeboat
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 April 2005 Resolved
Properly attach waterlight to life ring buoys.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2005
Resolved 12 April 2005
Resolution: Properly attached waterlight in the presence of marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 12 April 2005 Resolved
replace expired chem lights on eight life jackets.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 11 May 2005
Resolution: replaced lights
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 April 2005 Resolved
replace retro-reflective tape on eight life jackets.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 11 May 2005
Resolution: Replaced retro with new type 1.
Personnel › Training › First Aid/CPR
Issued 12 April 2005 Resolved
Provide evidence of firstaid/CPR training.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 11 May 2005
Resolution: Provided proof of training.
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 12 April 2005 Resolved
Replace missing section of exhaust insulation on port engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 11 May 2005
Resolution: Replaced insulation.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 April 2005 Resolved
installl light fixture guard on lights in enginroom.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 11 May 2005
Resolution: Installed light guards.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 12 April 2005 Resolved
Provide securing device to laz watertight hatch cover.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 11 May 2005
Resolution: Installed securing device to hatch cover.
Communications › Radio Communications › EPIRB
Issued 12 April 2005 Resolved
Provide proof of updated NOAA sticker.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 11 May 2005
Resolution: Provided proof of registration.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 7 May 2004 Resolved
Replace one inch pipe on port engine salt water pump prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2004
Resolution: Replaced piping as required.
Engineering › Generator (propulsion-electric) › Contactor
Issued 7 May 2004 Resolved
Install mounting bolts on the aft port generator prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2004
Resolution: Bolted IAW CG-835
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 7 May 2004 Resolved
Provide mounting brackets or supports for portable fire fighting extinguishers prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 7 May 2004 Resolved
Recharge FF extinguishers on the bridge and galley prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2004
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 7 May 2004 Resolved
Provide donning placard for all types of life preservers onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2004
Lifesaving › Lifebuoys › Quantity
Issued 7 May 2004 Resolved
Provide third life ring prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 May 2004 Resolved
Provide water light for at least one life ring prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2004
Lifesaving › Lifefloat › Quantity
Issued 7 May 2004 Resolved
Provide two paddles missing from aft life float prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2004
Lifesaving › Lifefloat › Float Free
Issued 7 May 2004 Resolved
Permanently attach weak link for aft set of life floats prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2004
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 May 2004 Resolved
Repair adult and child life preservers and provide retro reflective tape as needed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 7 May 2004 Resolved
Post operating instructions beside remote fire fighting pull box to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 7 May 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 7 May 2004 Resolved
Provide at least a medium frequency radio (MF). Vessel's route is restricted to no greater than 20NM from shore.
Due 30 May 2004
Resolved 13 July 2004
Stability › Incline Test › General
Issued 7 May 2004 Resolved
Conduct a proper stability test to determine maximum number of passengers allowed onboard / on the upper deck. No passengers allowed on upper deck until stability test conducted and approved by USCG.
Action required: 705 - Other - as specified
Resolved 19 May 2009
Resolution: Details transferred to vessel''s special notes.
Engineering › Bilge Water Management System › Valve
Issued 14 March 2002 Resolved
Provide positive shut off valve to rule bilge overboard discharge hoses.
Due 22 March 2002
Resolved 15 March 2002
Resolution: Valves present
Lifesaving
Issued 14 March 2002 Resolved
Prove proper operation of EPIRB. Vsl limited to no more than three miles from shore with passengers. LEGACY COMPONENT DESC: EPIRB
Due 29 March 2002
Resolved 3 April 2002
Resolution: Vsl owner submitted paperwork of serviving report for EPIRB.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 March 2002 Resolved
Conduct a man overboard drill.
Due 22 March 2002
Resolved 15 March 2002
Resolution: Vsl conducted satisfactory man overboard drill.
Fire Fighting
Issued 31 May 2001 Resolved
Make repairs to fixed gas fire extinguishing system in accordance with 46CFR181.410 and install controls in accordance with 46CFR181.410(b) and prove proper operation in presence of U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 13 July 2001
Resolved 2 August 2001
Fire Fighting
Issued 31 May 2001 Resolved
Provide fire detection system that meets 46CFR181.400.
Condition: Unknown
Due 13 July 2001
Resolved 2 August 2001
Construction/Loadline
Issued 31 May 2001 Resolved
IAW 46 CFR 185.30-3 mark vessel w/ permanent draft & loading marks.
Condition: Unknown
Due 31 December 2002
Resolved 2 August 2001
Lifesaving
Issued 31 May 2001 Resolved
Provide first aid kit w/ 46 CFR 160.041 approval number.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 31 May 2001 Resolved
Renew life float painters & properly install to life floats (both arrangements).
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Fire Fighting
Issued 31 May 2001 Resolved
Provide fire axe & mark w/ vessel name & mount in or near operating station.
Condition: Unknown
Due 29 June 2001
Resolved 12 July 2001
Engineering
Issued 31 May 2001 Resolved
Install 30 x 30 mesh flame screens to port & stbd fuel vents.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 31 May 2001 Resolved
Provide platform for rescue ladder.
Condition: Unknown
Due 29 June 2001
Resolved 12 July 2001
Navigation
Issued 31 May 2001 Resolved
Provide 300 mm (11.8") bell.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Documentation
Issued 31 May 2001 Resolved
Provide drug & alcohol policy & post hotline numbers.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Construction/Loadline
Issued 31 May 2001 Resolved
Make all through bulkhead penetrations watertight.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Construction/Loadline
Issued 31 May 2001 Resolved
Provide screw-down valve to bilge piping which perces the collision bulkhead operable from the weather deck or on the after side of the collision bulkhead.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Electrical
Issued 31 May 2001 Resolved
Provide & install UL1104 all around white light w/ fixture (anchor light) to provide 360 degree visibility.
Condition: Unknown
Due 29 June 2001
Resolved 12 July 2001
Fire Fighting
Issued 31 May 2001 Resolved
Provide vent closures for engine room natural ventilation IAW 46 CFR 182.465(h) & 46 CFR 181.20-35.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Construction/Loadline
Issued 31 May 2001 Resolved
Install adequate Rule pump hose in compartments 2, 3 & 4.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Electrical
Issued 31 May 2001 Resolved
Repair battery leads where coating is broken.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Engineering
Issued 31 May 2001 Resolved
Install fuel line supports as necessary.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Electrical
Issued 31 May 2001 Resolved
Remove all dead end wire throughout vessel.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Engineering
Issued 31 May 2001 Resolved
Provide grounding strap to port fuel tank fill.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Accommodation/Occupational Safety
Issued 31 May 2001 Resolved
Repair MSD line union.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 31 May 2001 Resolved
Lifejacket requirements as follows: Provide lights for 41 adult life jackets & 7 child lifejackets & renew retroreflective tape to 20 adult lifejackets & install additional retroreflective tape to 3 child lifejackets.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 31 May 2001 Resolved
Provide & install proper weak links (2) for life float arrangements.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 14 December 1999 Resolved
13 LIFE JACKETS FOUND IN UNSATISFACTORY CONDITION. REPAIR RENEW JACKETS PASSENGER CAPISITY REDUCED TO 82 PERSONS UNTIL JACKETS ARE REPAIRD OR RENEWED.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Lifesaving
Issued 14 December 1999 Resolved
LIGHT STANCHIONS FOR LIFE FLOATS LOCATED ON UPPER DECK IS BROKEN REPAIR/RENEW.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Construction/Loadline
Issued 14 December 1999 Resolved
DECK PLATING ON AFT STBD CORNER ROTTED REPLACE/RENEW.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Fire Fighting
Issued 14 December 1999 Resolved
VESSEL NO2 FIRE PUMP HAS LEAK, REPAIR/RENEW.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Lifesaving
Issued 14 December 1999 Resolved
LIGHT ON FWD LIFE RING IS INOPERABLE REPAIR/RENEW LIGHT.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Engineering
Issued 14 December 1999 Resolved
Generator fuel line is missing a valve and a valve in the fuel must have a reach rod. Vessel owner must install valve and reach rod prior to carrying passengers for hire.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Engineering
Issued 30 June 1999 Resolved
REPLACE THE PORT SIDE CUTLASS BEARING ON THE PROPELLER SHAFT.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Construction/Loadline
Issued 30 June 1999 Resolved
PROVIDE BILGE HIGH LEVEL ALARMS FOR ALL COMPARTMENTS (5) REMAINING ON BOARDTHE VESSEL.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Fire Fighting
Issued 30 June 1999 Resolved
PROVIDE A FIXED FIRE FIGHTING EXTINGUISHING SYSTEM FOR THE ENGINE ROOM.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Documentation
Issued 4 January 1999 Resolved
VESSEL FCC SAFETY CERTIFICATE HAS EXPIRED(09AUG98) VESSEL TO RENEW CERTIFICATE PRIOR TO 04FEB99.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Electrical
Issued 4 January 1999 Resolved
THE FOLLOWING ELECTRICAL PROBLEMS NEED TO BE REPAIRED: WIRES NEED TO BE DEAD ENDED UNDER BRIDGE CONSOLE, ONE WIRE NEEDS TO BE DEAD ENDED ON PORT ENGINE, SPEAKER WIRES NEED TO BE TAPED LOCATED ON STBD SIDE, ELECTRICAL BOXAFT PORTSIDE & ELECTRICAL LIGHT BOX FWD PORT SIDE NEED TO BE COVERED.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Lifesaving
Issued 4 January 1999 Resolved
EPIRB BATTERY HAS EXPIRED. RENEW PRIOR TO 04FEB99.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Construction/Loadline
Issued 4 January 1999 Resolved
REPAIR SOFT WOOD & GOUGE ON DECK OUTBOARD STBD ENGINE, AND REPAIR SOFT WOODOUTBOARD PORT ENGINE.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Navigation
Issued 4 January 1999 Resolved
BRACKET ON STBD STEERING GEAR IS VIBRATING DUE TO LOOSE BOLTS. VESSEL_x001C_ TO REPAIR PRIOR TO 04FEB99.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Lifesaving
Issued 4 January 1999 Resolved
MISSING LINE ON RING BUOY LOCATED UP FWD.
Condition: Unknown
Due 4 January 1999
Resolved 4 January 1999
Accommodation/Occupational Safety
Issued 8 December 1997 Resolved
Found holding tank had verticl crack approximately 7" in length. System showed indications that it would not adequately hold contents. Required torepair prior to conducting commercial operations greater than 30 minutes inlength. Crew immediately repaired w/fiberglass patch.
Condition: Unknown
Due 8 December 1997
Resolved 9 December 1997
Electrical
Issued 8 December 1997 Resolved
Outer lighting missing light globe protective covers.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Electrical
Issued 8 December 1997 Resolved
Electrical junction box located in the main accomodation cabin, aft, does not have protective cover.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Electrical
Issued 8 December 1997 Resolved
Breaker panel located under bridge control area does not have cover. Issued requirement to install a protective cover over the breaker switch.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Construction/Loadline
Issued 30 June 1997 Resolved
Make bulkhead penetration to collision bulkhead watertight.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Engineering
Issued 30 June 1997 Resolved
Repair/replace grounding strap to port fuel tank
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Construction/Loadline
Issued 30 June 1997 Resolved
REPAIR/REPLACE CRACKED FRAMES ON THIRD AND NINTH FRAMES FROM FORWARD BLKHD AFT STEERING.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Construction/Loadline
Issued 30 June 1997 Resolved
Replace/repair overhead long on portside E/R.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Engineering
Issued 30 June 1997 Resolved
REPLACE CORRODED NUT ON FORWARD OUTBOARD FUEL TANK MOUNT._x001C_
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Construction/Loadline
Issued 30 June 1997 Resolved
REPLACE NUT AND BOLT ON FIRST FRAME FROM FOWARD BLKHD OF AFT STEERING.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Construction/Loadline
Issued 30 June 1997 Resolved
Make bulkhead penetration watertight to aft bulkhead fuel tank compartment.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Navigation
Issued 17 December 1996 Resolved
PROVIDE UPDATED TIDE/CURRENT TABLES, LIGHT LIST. ALSO, PROVIDE CHART FOR OCEANS ROUTE.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 17 December 1996 Resolved
MARK ALL ADULT AND CHILD PFD STOWAGE LOCKERS.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Construction/Loadline
Issued 17 December 1996 Resolved
INSTALL VALVES ON RULE PUMP BKHD PENETRATIONS IAW 46 CFR 182.40- 1(a)(1)(ii)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Documentation
Issued 17 December 1996 Resolved
PROVIDE STABILITY DATA APPLICABLE TO REMOVAL OF SSG.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 17 December 1996 Resolved
PROVIDE (3) RED DISTRESS FLARES AND PROPER BULB FOR MAST NAVLIGHT. VESSEL IS RESTRICTED TO DAYLIGHT OPERATIONS UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Construction/Loadline
Issued 17 December 1996 Resolved
INSTALL 2ND BILGE PUMP IAW 46 CFR 182.25-10(a).
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Electrical
Issued 17 December 1996 Resolved
PLACE PORTABLE LIGHTS IN REACH OF CONTROL STATION AND MACHINERY SPACE ACCESS.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 17 December 1996 Resolved
MARK EPIRB W/ VESSEL NAME.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Accommodation/Occupational Safety
Issued 17 December 1996 Resolved
MARK EXTERIOR OF ESCAPE HATCH IAW 46 CFR 185.30-15.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Documentation
Issued 17 December 1996 Resolved
ESTABLISH TRAINING LOGS, POST PFD PLACARDS AND STATION BILL IAW 46 CFR 185 DTD 11MAR 96.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Electrical
Issued 17 December 1996 Resolved
PROVIDE COMPLETE ELECTRICAL DATA, DRAWINGS, BREAKER/PANEL/WIRING INFO FOR NEWLY INSTALLED 12 VDC SYSTEM. INFO TO INCLUDE DATA FROM POWER SOURCE TO COMPONENTS.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Fire Fighting
Issued 17 December 1996 Resolved
INSTALL PRESSURE GAUGE ON FIRE PUMP DISCHARGE.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Lifesaving
Issued 20 December 1995 Resolved
RENEW THREE ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 20 January 1996
Resolved 11 January 1996
Lifesaving
Issued 20 December 1995 Resolved
RENEW WATER LIGHT FOR 11 MAN LIFE FLOAT.
Condition: Unknown
Due 20 January 1996
Resolved 8 January 1996
Lifesaving
Issued 27 December 1994 Resolved
PROVIDE TWO (2) CHILD AND ONE (1) ADULT TYPE 1 LIFE PRESERVER. VESSEL RESTRICTED TO EIGHT (8) CHILDREN AND NINTY-FOUR (94) ADULTS UNTIL REPLACEMENT PRESERVERS ONBOARD.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Construction/Loadline
Issued 27 December 1994 Resolved
REPLACE DETERIORATED BILGE SUCTION STRAINER & CHECK VALVE AND TEST SYSTEM PRIOR TO CARRIAGE OF PASSENGERS IN THE FORWARD LOWER LOUNGE BILGE.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Lifesaving
Issued 27 December 1994 Resolved
PROVIDE REPLACEMENT WATERLIGHTS FOR AFT TOP PORT LIFEFLOAT AND FORWARD TOP LIFEFLOAT.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Accommodation/Occupational Safety
Issued 27 December 1994 Resolved
RECONNECT PORT HEAD WASH BASIN DRAIN PIPING TO MARINE SANITATION DEVICE.
Condition: Unknown
Due 27 December 1994
Resolved 27 December 1994
Accommodation/Occupational Safety
Issued 3 January 1994 Resolved
PROVE PROPER OPERATION OF FRESH WATER SYSTEM TO WASH BASINS.
Condition: Unknown
Due 10 February 1994
Resolved 10 February 1994
Engineering
Issued 3 January 1994 Resolved
REPLACE FLEXIBLE HOSE IN FUEL FILL PIPING TO PORT FUEL TANK.
Condition: Unknown
Due 10 February 1994
Resolved 10 February 1994
Lifesaving
Issued 3 January 1994 Resolved
PROVIDE ONE ADULT TYPE I LIFE PRESERVER; VESSEL LIMITED TO A MAXIMUM OF 78 PASSENGERS UNTIL REQUIRED LIFE PRESERVER IS ONBOARD VESSEL PROPERLY MARKED AND EQUIPPED WITH LIGHT.
Condition: Unknown
Due 10 February 1994
Resolved 10 February 1994
Navigation
Issued 3 January 1994 Resolved
PROVIDE CURRENT NAUTICAL CHARTS FOR AREA OF OPERATION, COAST PILOT, LIGHT LIST, TIDE TABLES AND CURRENT TABLES.
Condition: Unknown
Due 10 February 1994
Resolved 10 February 1994
Lifesaving
Issued 19 February 1993 Resolved
PROVIDE ONE PORTABLE RESCUE LADDER/PLATFORM CAPABLE OF MOUNTING ON PORT OR STBD SIDES.
Condition: Unknown
Due 19 February 1993
Resolved 19 February 1993
Lifesaving
Issued 5 January 1993 Resolved
PROVIDE ONE ADULT LIFE PRESERVER, VESSEL RESTRICTED TO 72 PASSENGERS UNTIL ABOVE LIFE PRESERVER IS ONBOARD WITH PROPER MARKINGS.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Lifesaving
Issued 5 January 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Construction/Loadline
Issued 5 January 1993 Resolved
LABLE BILGE MAINIFOLD VALVES.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Lifesaving
Issued 5 January 1993 Resolved
RESTENCIL CAPACITY ON FORWARD TWO LIFEFLOATS.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Lifesaving
Issued 5 January 1993 Resolved
RESTENCIL TOPSIDE ADULT LIFE PRESERVER STOWAGE CONTAINER WITH NUMBER OF JACKETS CONTAINED.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Lifesaving
Issued 5 January 1993 Resolved
PROVIDE ONE WATER LIGHT FOR STBD. AFT LIFEFLOAT.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Lifesaving
Issued 5 January 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Documentation
Issued 5 January 1993 Resolved
PROVIDE CURRENT FCC OPERATORS PERMIT.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Lifesaving
Issued 5 January 1993 Resolved
RELOCATE LIFE PRESERVER WATER LIGHTS TO COLLAR AREA.
Condition: Unknown
Due 5 January 1993
Resolved 5 January 1993
Construction/Loadline
Issued 7 January 1992 Resolved
PERMANENTLY SEAL VENTILATION OPENINGS IN THE VESSELS TRANSOM.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Lifesaving
Issued 31 October 1991 Resolved
REPLACE/REPAIR THE FOUR (4) ELEVEN (11) MAN LIFEFLOATS LOCATED ON THE 01 DECK AFT. VESSEL LIMTED TO 74 PERSONS IN COASTWISE OPERATION AND 37 PERSONSFOR OCEANS OPERATIONS UNTIL ABOVE REQUIREMENT MET.
Condition: Unknown
Due 31 January 1992
Resolved 26 February 1992
Navigation
Issued 8 February 1990 Resolved
MAKE THE VESSEL AVAILABLE FOR AN EXAMINATION OF THE NEW STEERING ARRANGEMENT.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Lifesaving
Issued 17 January 1990 Resolved
PUT NAME OF THE VESSEL ON LIFE FLOAT PADDLES.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Fire Fighting
Issued 17 January 1990 Resolved
REMOUNT VESSEL'S FIRE AXE.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Lifesaving
Issued 17 January 1990 Resolved
TOTAL CHILDREN CAPACITY IS LIMITED TO NINE (9), UNTIL THE TENTH REQUIRED CHILD-SIZE PERSONAL FLOTATION DEVICE IS PROVIDED ON BOARD.
Condition: Unknown
Due 17 January 1990
Resolved 17 January 1990
Engineering
Issued 5 February 1988 Resolved
REPLACE AND REPAIR MDE DRY EXHAUST BRACKETS IN WAY OF THE MAIN DECK AFT ENTRANCE TO THE ENGINE ROOM NEXT SCHEDULE DRY DOCKING SEPT88.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Fire Fighting
Issued 5 February 1988 Resolved
PROPERLY SERVICE ONE B-I FIRE EXTINGUISHER IN THE WHEELHOUSE, PRIOR CARRYING PASSENGERS FOR HIRE, BUT NOT LATER THAN 10 FEB88.
Condition: Unknown
Due 5 February 1988
Resolved 5 February 1988
Lifesaving
Issued 4 March 1987 Resolved
PROVIDE FOR THE -12- MAN LIFE FLOAT ONE PADDLE AT LEAST 4 FOOT LONG.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Fire Fighting
Issued 4 March 1987 Resolved
PROVIDE ON BOARD FOUR USCG B-II RATED HAND PORTABLE FIRE EXTINGUISHERS AS REQUIRED BY THE VESSEL'S CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Construction/Loadline
Issued 4 March 1987 Resolved
RENEW THE CRACKED WINDOWS IN THE PILOT HOUSE AND MAIN DECK CABIN.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Fire Fighting
Issued 4 March 1987 Resolved
PROVIDE A PRESSURE GAUGE FOR THE DISCHARGE SIDE OF THE FIRE PUMP.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Lifesaving
Issued 4 March 1987 Resolved
PROVIDE -7- ADULT AND -5- CHILD TYPE I LIFE PRESERVERS.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Accommodation/Occupational Safety
Issued 4 March 1987 Resolved
PROVIDE THE PROPER MARKINGS FOR THE LIFE PRESERVER STORAGE, LIFE FLOATS, AND RING LIFE BUOYS.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Lifesaving
Issued 19 March 1986 Resolved
PROVIDE FOUR(4) ADULTS PFD, TYPE I,APPROVED TYPE. MAXIMUM PASSENGER ALLOWEDIS REDUCED TO 83 UNTIL THIS ITEM IS CORRECTED TO THE SATISFACTION OF OCMI.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986
Lifesaving
Issued 19 March 1986 Resolved
PROVIDE SIX (6) WATER LIGHTS IN GOOD CONDITION, ONE EACH TO SIX (6) LIFE- FLOATS CARRIED ON BOARD BEFORE ANY SCHEDULED NIGHT SAILING ANND NOT LATER THAN 15 DAYS AFTER THIS DAY.
Condition: Unknown
Due 19 March 1986
Resolved 19 March 1986

Casualty record · 1

4 August 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6255431
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.