← All vessels
OCEAN PRINCESS
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG East District (CGD-E) · Other hulls named OCEAN PRINCESS
OCEAN PRINCESS is a 1975 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1985, most recently in May 2026, along with 145 deficiencies and 1 casualty investigation in 2017.
Records from 1985 to 2026. Most recent: inspection, 14 May 2026.
- Built
- 1975
- Last inspected
- 14 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 145 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2017
Identity
564267
WDB8212
48349
Flag
UNITED STATES
366954840
Maury page id
psix-48349
Inspections, by type
…with no type recorded7
Years with a record
40 calendar years (1985–2026)
The 79 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)70.5 ft × 21.4 ft × 7.2 ft
Registered tonnagegross 85 / net 68
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT LEON SHERBERT · PONCE INLET, FL, UNITED STATES · built 1975
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portOCEAN CITY, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it85 - Regulatory (Subpart C or D), Gross Ton
68 - Regulatory (Subpart C or D), Net Ton
68 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDB8212MMSI 366954840 · active · compulsorily equipped · granted 13 March 2024, expires 8 June 2034
WDA3368MMSI 366797650 · expired · compulsorily equipped · granted 19 January 2001, cancelled 26 March 2011 · licensed under a name not among this hull’s recorded names (not shown)
WTS9701MMSI not assigned · expired · compulsorily equipped · granted 12 November 1996, cancelled 14 April 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 79
14 May 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8375423
14 May 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8142277
13 February 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8080796
22 April 2024
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7897184
12 June 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7734672
15 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7636447
22 June 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7476665
25 February 2022
Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7402065
26 July 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7282890
12 February 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7141151
20 July 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7026074
30 April 2019
DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6674513
27 February 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6638654
30 July 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6511640
4 August 2017
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6255431
16 May 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6152443
16 May 2017
DAPI Audit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6154144
5 May 2017
Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6139506
7 April 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6126493
27 June 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6036996
15 August 2015
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5218942
5 May 2014
COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4841596
1 May 2012
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4299810
14 December 2011
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4304630
24 February 2011
Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3947030
29 April 2009
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3458271
2 June 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3447157
15 May 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3205641
23 May 2007
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2944768
30 April 2007
Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2921277
24 April 2006
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2632057
10 April 2006
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2616550
12 May 2005
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2355624
12 April 2005
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2329299
29 March 2005
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2319314
7 May 2004
Annual Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2062056
19 May 2003
Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1796409
27 March 2003
Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1760711
14 March 2002
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1493574
31 May 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1408750
3 April 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1059894
1 February 2000
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 814620
14 December 1999
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1399252
14 December 1999
Plan Review "T" Boat · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1403304
27 July 1999
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1106462
30 June 1999
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1440155
4 January 1999
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1406410
27 January 1998
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1117744
8 December 1997
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1451250
25 August 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1120164
25 July 1997
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1117109
30 June 1997
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 780561
17 December 1996
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1095196
20 December 1995
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 880456
13 December 1995
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1193710
11 December 1995
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1188533
6 January 1995
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 857574
27 December 1994
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1159737
3 January 1994
COI Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 851090
4 November 1993
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 830436
25 March 1993
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1149410
19 February 1993
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 835739
5 January 1993
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1138553
14 April 1992
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1254470
7 January 1992
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1265350
31 October 1991
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 952780
15 July 1991
Drydock Extension
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 937670
14 January 1991
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1233474
21 March 1990
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1212940
8 February 1990
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1218061
17 January 1990
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 928289
7 February 1989
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1342842
20 September 1988
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1353152
5 February 1988
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1326426
7 October 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1320262
4 March 1987
COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1016441
19 March 1986
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 991707
29 October 1985
Credit Drydock
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 993366
26 March 1985
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 983341
Deficiency record · 145
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 April 2024
Resolved
46 CFR 181.310(c)
Spanner wrenches must be provided where 1.5 inch diameter fire hose is required by 181.320(b).
Vessel is missing spanner wrenches for fire hose stations.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 April 2024
Resolved
46 CFR 180.210(a)
A vessel of more than 65 feet in length must carry at least one rescue boat unless the cognizant OCMI determines that: (1) The vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water:
The vessel's rescue ladder had corroded attachment chains and carabiner. Replace with fittings that exceed weight capacity for 02 persons.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2024
Resolved
46 CFR 182.520(e)(7)
A positive shutoff valve is installed at the hull penetration
Submersible electric bilge pump was missing shutoff valve at the hull.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 February 2023
Resolved
Marine inspectors shall inspect all railings and bulwarks and their attachment to the hull structure. On the vessel's top deck the railing is unattached from the stiffener in one location and cracked in another. 46 CFR176.802
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 7 April 2017
Resolved
Provide/Submit plans for new air conditioning system installation.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 5 May 2014
Resolved
Provide two additional adult life jackets w/lights and marked with vessel name.
Documentation › Logs/Records › Logbook (official)
Issued 5 May 2014
Resolved
Provide vessel logbook, Ttaining log, and lifesaving maintenance log.
Lifesaving › Lifefloat › Markings
Issued 5 May 2014
Resolved
Re-label lifefloats with vessel name and persons capacity.
Lifesaving › Lifefloat › Lifeline
Issued 17 May 2012
Resolved
Lifeline and retro-reflective tape is wasted on aft bottom lifefloat. Vsl will remove this lifefloat until properly repaired. Vsl maintains 4 additional lifefloats that meet the required primary lifesaving requirements.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 May 2012
Resolved
Vessel is missing 06 adult lifejackets and 02 lifejackets. Vessel is restricted to 60 paxs and 03 crewmembers until new lifejackets are provided.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 May 2012
Resolved
Ring buoy on top deck had wasted lifeline. Vsl replaced lifeline with a yellow buoyant line, which does not meet the regulation of a line that is dark in color. Vsl will need to provide new lifeline IAW 46 CFR 180.70.
Lifesaving › Lifefloat › Serviceable
Issued 17 May 2012
Resolved
All lifefloats have portions that are damaged and could lead to water intrusion. Vsl owner will repair all affected areas of lifefloats IAW manufacturer's instructions.
Construction/Loadline › Hull › Hull Plating
Issued 24 February 2011
Resolved
Vsl must perform an underway checkride prior to carrying passengers.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 15 May 2008
Resolved
Provide protective covering for distribution panel on the bridge.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 15 May 2008
Resolved
Repair exposed lagging on exhaust pipe.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 May 2008
Resolved
Provide three additional life jackets prior to sailing with maximum amount of passengers.
Fire Fighting › Firemans Outfit › Axe
Issued 15 May 2008
Resolved
Stencil and mount fire axe at operating station.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 May 2008
Resolved
Provide 3 alcohol testing kits.
Engineering › Fuel Oil Service System › Tank
Issued 30 April 2007
Resolved
Remove pitted areas on starboard fuel tank aft, conduct internal visual inspection, replace with original scantling, pressure test or replace fuel tank entirely.
Lifesaving › Lifebuoys › Serviceable
Issued 30 April 2007
Resolved
Replace or recondition faded aft life ring.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 10 April 2006
Resolved
Provide brackets for all portable fire extinguishers with-in 7 days.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 April 2006
Resolved
Provide proof of fixed fire/portable fire extinguisher servicing as required.
Communications › Audible Communications › Bell
Issued 10 April 2006
Resolved
Provide 300mm bell as required by 33 CFR part 86.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 April 2006
Resolved
Provide retro reflective material to equal 31 square inches each side of 12 life jackets.
Lifesaving › Lifeboat › Hull
Issued 12 April 2005
Resolved
Replace 15 man lifeboat, due to holes in Hull.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 April 2005
Resolved
Properly attach waterlight to life ring buoys.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 12 April 2005
Resolved
replace expired chem lights on eight life jackets.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 April 2005
Resolved
replace retro-reflective tape on eight life jackets.
Personnel › Training › First Aid/CPR
Issued 12 April 2005
Resolved
Provide evidence of firstaid/CPR training.
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 12 April 2005
Resolved
Replace missing section of exhaust insulation on port engine.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 April 2005
Resolved
installl light fixture guard on lights in enginroom.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 12 April 2005
Resolved
Provide securing device to laz watertight hatch cover.
Communications › Radio Communications › EPIRB
Issued 12 April 2005
Resolved
Provide proof of updated NOAA sticker.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 7 May 2004
Resolved
Replace one inch pipe on port engine salt water pump prior to carrying passengers.
Engineering › Generator (propulsion-electric) › Contactor
Issued 7 May 2004
Resolved
Install mounting bolts on the aft port generator prior to carrying passengers.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 7 May 2004
Resolved
Provide mounting brackets or supports for portable fire fighting extinguishers prior to carrying passengers.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 7 May 2004
Resolved
Recharge FF extinguishers on the bridge and galley prior to carrying passengers.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 7 May 2004
Resolved
Provide donning placard for all types of life preservers onboard.
Lifesaving › Lifebuoys › Quantity
Issued 7 May 2004
Resolved
Provide third life ring prior to carrying passengers.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 May 2004
Resolved
Provide water light for at least one life ring prior to carrying passengers.
Lifesaving › Lifefloat › Quantity
Issued 7 May 2004
Resolved
Provide two paddles missing from aft life float prior to carrying passengers.
Lifesaving › Lifefloat › Float Free
Issued 7 May 2004
Resolved
Permanently attach weak link for aft set of life floats prior to carrying passengers.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 7 May 2004
Resolved
Repair adult and child life preservers and provide retro reflective tape as needed prior to carrying passengers.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 7 May 2004
Resolved
Post operating instructions beside remote fire fighting pull box to the satisfaction of the attending marine inspector.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 May 2004
Resolved
Provide at least a medium frequency radio (MF). Vessel's route is restricted to no greater than 20NM from shore.
Stability › Incline Test › General
Issued 7 May 2004
Resolved
Conduct a proper stability test to determine maximum number of passengers allowed onboard / on the upper deck. No passengers allowed on upper deck until stability test conducted and approved by USCG.
Engineering › Bilge Water Management System › Valve
Issued 14 March 2002
Resolved
Provide positive shut off valve to rule bilge overboard discharge hoses.
Lifesaving
Issued 14 March 2002
Resolved
Prove proper operation of EPIRB. Vsl limited to no more than three miles from shore with passengers. LEGACY COMPONENT DESC: EPIRB
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 March 2002
Resolved
Conduct a man overboard drill.
Fire Fighting
Issued 31 May 2001
Resolved
Make repairs to fixed gas fire extinguishing system in accordance with 46CFR181.410 and install controls in accordance with 46CFR181.410(b) and prove proper operation in presence of U.S. Coast Guard Marine Inspector.
Fire Fighting
Issued 31 May 2001
Resolved
Provide fire detection system that meets 46CFR181.400.
Construction/Loadline
Issued 31 May 2001
Resolved
IAW 46 CFR 185.30-3 mark vessel w/ permanent draft & loading marks.
Lifesaving
Issued 31 May 2001
Resolved
Provide first aid kit w/ 46 CFR 160.041 approval number.
Lifesaving
Issued 31 May 2001
Resolved
Renew life float painters & properly install to life floats (both arrangements).
Fire Fighting
Issued 31 May 2001
Resolved
Provide fire axe & mark w/ vessel name & mount in or near operating station.
Engineering
Issued 31 May 2001
Resolved
Install 30 x 30 mesh flame screens to port & stbd fuel vents.
Lifesaving
Issued 31 May 2001
Resolved
Provide platform for rescue ladder.
Navigation
Issued 31 May 2001
Resolved
Provide 300 mm (11.8") bell.
Documentation
Issued 31 May 2001
Resolved
Provide drug & alcohol policy & post hotline numbers.
Construction/Loadline
Issued 31 May 2001
Resolved
Make all through bulkhead penetrations watertight.
Construction/Loadline
Issued 31 May 2001
Resolved
Provide screw-down valve to bilge piping which perces the collision bulkhead operable from the weather deck or on the after side of the collision bulkhead.
Electrical
Issued 31 May 2001
Resolved
Provide & install UL1104 all around white light w/ fixture (anchor light) to provide 360 degree visibility.
Fire Fighting
Issued 31 May 2001
Resolved
Provide vent closures for engine room natural ventilation IAW 46 CFR 182.465(h) & 46 CFR 181.20-35.
Construction/Loadline
Issued 31 May 2001
Resolved
Install adequate Rule pump hose in compartments 2, 3 & 4.
Electrical
Issued 31 May 2001
Resolved
Repair battery leads where coating is broken.
Engineering
Issued 31 May 2001
Resolved
Install fuel line supports as necessary.
Electrical
Issued 31 May 2001
Resolved
Remove all dead end wire throughout vessel.
Engineering
Issued 31 May 2001
Resolved
Provide grounding strap to port fuel tank fill.
Accommodation/Occupational Safety
Issued 31 May 2001
Resolved
Repair MSD line union.
Lifesaving
Issued 31 May 2001
Resolved
Lifejacket requirements as follows: Provide lights for 41 adult life jackets & 7 child lifejackets & renew retroreflective tape to 20 adult lifejackets & install additional retroreflective tape to 3 child lifejackets.
Lifesaving
Issued 31 May 2001
Resolved
Provide & install proper weak links (2) for life float arrangements.
Lifesaving
Issued 14 December 1999
Resolved
13 LIFE JACKETS FOUND IN UNSATISFACTORY CONDITION. REPAIR RENEW JACKETS PASSENGER CAPISITY REDUCED TO 82 PERSONS UNTIL JACKETS ARE REPAIRD OR RENEWED.
Lifesaving
Issued 14 December 1999
Resolved
LIGHT STANCHIONS FOR LIFE FLOATS LOCATED ON UPPER DECK IS BROKEN REPAIR/RENEW.
Construction/Loadline
Issued 14 December 1999
Resolved
DECK PLATING ON AFT STBD CORNER ROTTED REPLACE/RENEW.
Fire Fighting
Issued 14 December 1999
Resolved
VESSEL NO2 FIRE PUMP HAS LEAK, REPAIR/RENEW.
Lifesaving
Issued 14 December 1999
Resolved
LIGHT ON FWD LIFE RING IS INOPERABLE REPAIR/RENEW LIGHT.
Engineering
Issued 14 December 1999
Resolved
Generator fuel line is missing a valve and a valve in the fuel must have a reach rod. Vessel owner must install valve and reach rod prior to carrying passengers for hire.
Engineering
Issued 30 June 1999
Resolved
REPLACE THE PORT SIDE CUTLASS BEARING ON THE PROPELLER SHAFT.
Construction/Loadline
Issued 30 June 1999
Resolved
PROVIDE BILGE HIGH LEVEL ALARMS FOR ALL COMPARTMENTS (5) REMAINING ON BOARDTHE VESSEL.
Fire Fighting
Issued 30 June 1999
Resolved
PROVIDE A FIXED FIRE FIGHTING EXTINGUISHING SYSTEM FOR THE ENGINE ROOM.
Documentation
Issued 4 January 1999
Resolved
VESSEL FCC SAFETY CERTIFICATE HAS EXPIRED(09AUG98) VESSEL TO RENEW CERTIFICATE PRIOR TO 04FEB99.
Electrical
Issued 4 January 1999
Resolved
THE FOLLOWING ELECTRICAL PROBLEMS NEED TO BE REPAIRED: WIRES NEED TO BE DEAD ENDED UNDER BRIDGE CONSOLE, ONE WIRE NEEDS TO BE DEAD ENDED ON PORT ENGINE, SPEAKER WIRES NEED TO BE TAPED LOCATED ON STBD SIDE, ELECTRICAL BOXAFT PORTSIDE & ELECTRICAL LIGHT BOX FWD PORT SIDE NEED TO BE COVERED.
Lifesaving
Issued 4 January 1999
Resolved
EPIRB BATTERY HAS EXPIRED. RENEW PRIOR TO 04FEB99.
Construction/Loadline
Issued 4 January 1999
Resolved
REPAIR SOFT WOOD & GOUGE ON DECK OUTBOARD STBD ENGINE, AND REPAIR SOFT WOODOUTBOARD PORT ENGINE.
Navigation
Issued 4 January 1999
Resolved
BRACKET ON STBD STEERING GEAR IS VIBRATING DUE TO LOOSE BOLTS. VESSEL_x001C_ TO REPAIR PRIOR TO 04FEB99.
Lifesaving
Issued 4 January 1999
Resolved
MISSING LINE ON RING BUOY LOCATED UP FWD.
Accommodation/Occupational Safety
Issued 8 December 1997
Resolved
Found holding tank had verticl crack approximately 7" in length. System showed indications that it would not adequately hold contents. Required torepair prior to conducting commercial operations greater than 30 minutes inlength. Crew immediately repaired w/fiberglass patch.
Electrical
Issued 8 December 1997
Resolved
Outer lighting missing light globe protective covers.
Electrical
Issued 8 December 1997
Resolved
Electrical junction box located in the main accomodation cabin, aft, does not have protective cover.
Electrical
Issued 8 December 1997
Resolved
Breaker panel located under bridge control area does not have cover. Issued requirement to install a protective cover over the breaker switch.
Construction/Loadline
Issued 30 June 1997
Resolved
Make bulkhead penetration to collision bulkhead watertight.
Engineering
Issued 30 June 1997
Resolved
Repair/replace grounding strap to port fuel tank
Construction/Loadline
Issued 30 June 1997
Resolved
REPAIR/REPLACE CRACKED FRAMES ON THIRD AND NINTH FRAMES FROM FORWARD BLKHD AFT STEERING.
Construction/Loadline
Issued 30 June 1997
Resolved
Replace/repair overhead long on portside E/R.
Engineering
Issued 30 June 1997
Resolved
REPLACE CORRODED NUT ON FORWARD OUTBOARD FUEL TANK MOUNT._x001C_
Construction/Loadline
Issued 30 June 1997
Resolved
REPLACE NUT AND BOLT ON FIRST FRAME FROM FOWARD BLKHD OF AFT STEERING.
Construction/Loadline
Issued 30 June 1997
Resolved
Make bulkhead penetration watertight to aft bulkhead fuel tank compartment.
Navigation
Issued 17 December 1996
Resolved
PROVIDE UPDATED TIDE/CURRENT TABLES, LIGHT LIST. ALSO, PROVIDE CHART FOR OCEANS ROUTE.
Lifesaving
Issued 17 December 1996
Resolved
MARK ALL ADULT AND CHILD PFD STOWAGE LOCKERS.
Construction/Loadline
Issued 17 December 1996
Resolved
INSTALL VALVES ON RULE PUMP BKHD PENETRATIONS IAW 46 CFR 182.40- 1(a)(1)(ii)._x001C_ _x001C_ _x001C_
Documentation
Issued 17 December 1996
Resolved
PROVIDE STABILITY DATA APPLICABLE TO REMOVAL OF SSG.
Lifesaving
Issued 17 December 1996
Resolved
PROVIDE (3) RED DISTRESS FLARES AND PROPER BULB FOR MAST NAVLIGHT. VESSEL IS RESTRICTED TO DAYLIGHT OPERATIONS UNTIL THIS REQUIREMENT IS MET.
Construction/Loadline
Issued 17 December 1996
Resolved
INSTALL 2ND BILGE PUMP IAW 46 CFR 182.25-10(a).
Electrical
Issued 17 December 1996
Resolved
PLACE PORTABLE LIGHTS IN REACH OF CONTROL STATION AND MACHINERY SPACE ACCESS.
Lifesaving
Issued 17 December 1996
Resolved
MARK EPIRB W/ VESSEL NAME.
Accommodation/Occupational Safety
Issued 17 December 1996
Resolved
MARK EXTERIOR OF ESCAPE HATCH IAW 46 CFR 185.30-15.
Documentation
Issued 17 December 1996
Resolved
ESTABLISH TRAINING LOGS, POST PFD PLACARDS AND STATION BILL IAW 46 CFR 185 DTD 11MAR 96.
Electrical
Issued 17 December 1996
Resolved
PROVIDE COMPLETE ELECTRICAL DATA, DRAWINGS, BREAKER/PANEL/WIRING INFO FOR NEWLY INSTALLED 12 VDC SYSTEM. INFO TO INCLUDE DATA FROM POWER SOURCE TO COMPONENTS.
Fire Fighting
Issued 17 December 1996
Resolved
INSTALL PRESSURE GAUGE ON FIRE PUMP DISCHARGE.
Lifesaving
Issued 20 December 1995
Resolved
RENEW THREE ORANGE SMOKE DISTRESS SIGNALS.
Lifesaving
Issued 20 December 1995
Resolved
RENEW WATER LIGHT FOR 11 MAN LIFE FLOAT.
Lifesaving
Issued 27 December 1994
Resolved
PROVIDE TWO (2) CHILD AND ONE (1) ADULT TYPE 1 LIFE PRESERVER. VESSEL RESTRICTED TO EIGHT (8) CHILDREN AND NINTY-FOUR (94) ADULTS UNTIL REPLACEMENT PRESERVERS ONBOARD.
Construction/Loadline
Issued 27 December 1994
Resolved
REPLACE DETERIORATED BILGE SUCTION STRAINER & CHECK VALVE AND TEST SYSTEM PRIOR TO CARRIAGE OF PASSENGERS IN THE FORWARD LOWER LOUNGE BILGE.
Lifesaving
Issued 27 December 1994
Resolved
PROVIDE REPLACEMENT WATERLIGHTS FOR AFT TOP PORT LIFEFLOAT AND FORWARD TOP LIFEFLOAT.
Accommodation/Occupational Safety
Issued 27 December 1994
Resolved
RECONNECT PORT HEAD WASH BASIN DRAIN PIPING TO MARINE SANITATION DEVICE.
Accommodation/Occupational Safety
Issued 3 January 1994
Resolved
PROVE PROPER OPERATION OF FRESH WATER SYSTEM TO WASH BASINS.
Engineering
Issued 3 January 1994
Resolved
REPLACE FLEXIBLE HOSE IN FUEL FILL PIPING TO PORT FUEL TANK.
Lifesaving
Issued 3 January 1994
Resolved
PROVIDE ONE ADULT TYPE I LIFE PRESERVER; VESSEL LIMITED TO A MAXIMUM OF 78 PASSENGERS UNTIL REQUIRED LIFE PRESERVER IS ONBOARD VESSEL PROPERLY MARKED AND EQUIPPED WITH LIGHT.
Navigation
Issued 3 January 1994
Resolved
PROVIDE CURRENT NAUTICAL CHARTS FOR AREA OF OPERATION, COAST PILOT, LIGHT LIST, TIDE TABLES AND CURRENT TABLES.
Lifesaving
Issued 19 February 1993
Resolved
PROVIDE ONE PORTABLE RESCUE LADDER/PLATFORM CAPABLE OF MOUNTING ON PORT OR STBD SIDES.
Lifesaving
Issued 5 January 1993
Resolved
PROVIDE ONE ADULT LIFE PRESERVER, VESSEL RESTRICTED TO 72 PASSENGERS UNTIL ABOVE LIFE PRESERVER IS ONBOARD WITH PROPER MARKINGS.
Lifesaving
Issued 5 January 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline
Issued 5 January 1993
Resolved
LABLE BILGE MAINIFOLD VALVES.
Lifesaving
Issued 5 January 1993
Resolved
RESTENCIL CAPACITY ON FORWARD TWO LIFEFLOATS.
Lifesaving
Issued 5 January 1993
Resolved
RESTENCIL TOPSIDE ADULT LIFE PRESERVER STOWAGE CONTAINER WITH NUMBER OF JACKETS CONTAINED.
Lifesaving
Issued 5 January 1993
Resolved
PROVIDE ONE WATER LIGHT FOR STBD. AFT LIFEFLOAT.
Lifesaving
Issued 5 January 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation
Issued 5 January 1993
Resolved
PROVIDE CURRENT FCC OPERATORS PERMIT.
Lifesaving
Issued 5 January 1993
Resolved
RELOCATE LIFE PRESERVER WATER LIGHTS TO COLLAR AREA.
Construction/Loadline
Issued 7 January 1992
Resolved
PERMANENTLY SEAL VENTILATION OPENINGS IN THE VESSELS TRANSOM.
Lifesaving
Issued 31 October 1991
Resolved
REPLACE/REPAIR THE FOUR (4) ELEVEN (11) MAN LIFEFLOATS LOCATED ON THE 01 DECK AFT. VESSEL LIMTED TO 74 PERSONS IN COASTWISE OPERATION AND 37 PERSONSFOR OCEANS OPERATIONS UNTIL ABOVE REQUIREMENT MET.
Navigation
Issued 8 February 1990
Resolved
MAKE THE VESSEL AVAILABLE FOR AN EXAMINATION OF THE NEW STEERING ARRANGEMENT.
Lifesaving
Issued 17 January 1990
Resolved
PUT NAME OF THE VESSEL ON LIFE FLOAT PADDLES.
Fire Fighting
Issued 17 January 1990
Resolved
REMOUNT VESSEL'S FIRE AXE.
Lifesaving
Issued 17 January 1990
Resolved
TOTAL CHILDREN CAPACITY IS LIMITED TO NINE (9), UNTIL THE TENTH REQUIRED CHILD-SIZE PERSONAL FLOTATION DEVICE IS PROVIDED ON BOARD.
Engineering
Issued 5 February 1988
Resolved
REPLACE AND REPAIR MDE DRY EXHAUST BRACKETS IN WAY OF THE MAIN DECK AFT ENTRANCE TO THE ENGINE ROOM NEXT SCHEDULE DRY DOCKING SEPT88.
Fire Fighting
Issued 5 February 1988
Resolved
PROPERLY SERVICE ONE B-I FIRE EXTINGUISHER IN THE WHEELHOUSE, PRIOR CARRYING PASSENGERS FOR HIRE, BUT NOT LATER THAN 10 FEB88.
Lifesaving
Issued 4 March 1987
Resolved
PROVIDE FOR THE -12- MAN LIFE FLOAT ONE PADDLE AT LEAST 4 FOOT LONG.
Fire Fighting
Issued 4 March 1987
Resolved
PROVIDE ON BOARD FOUR USCG B-II RATED HAND PORTABLE FIRE EXTINGUISHERS AS REQUIRED BY THE VESSEL'S CERTIFICATE OF INSPECTION.
Construction/Loadline
Issued 4 March 1987
Resolved
RENEW THE CRACKED WINDOWS IN THE PILOT HOUSE AND MAIN DECK CABIN.
Fire Fighting
Issued 4 March 1987
Resolved
PROVIDE A PRESSURE GAUGE FOR THE DISCHARGE SIDE OF THE FIRE PUMP.
Lifesaving
Issued 4 March 1987
Resolved
PROVIDE -7- ADULT AND -5- CHILD TYPE I LIFE PRESERVERS.
Accommodation/Occupational Safety
Issued 4 March 1987
Resolved
PROVIDE THE PROPER MARKINGS FOR THE LIFE PRESERVER STORAGE, LIFE FLOATS, AND RING LIFE BUOYS.
Lifesaving
Issued 19 March 1986
Resolved
PROVIDE FOUR(4) ADULTS PFD, TYPE I,APPROVED TYPE. MAXIMUM PASSENGER ALLOWEDIS REDUCED TO 83 UNTIL THIS ITEM IS CORRECTED TO THE SATISFACTION OF OCMI.
Lifesaving
Issued 19 March 1986
Resolved
PROVIDE SIX (6) WATER LIGHTS IN GOOD CONDITION, ONE EACH TO SIX (6) LIFE- FLOATS CARRIED ON BOARD BEFORE ANY SCHEDULED NIGHT SAILING ANND NOT LATER THAN 15 DAYS AFTER THIS DAY.
Casualty record · 1
4 August 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6255431
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.