Records in 2016. Most recent: inspection, 26 August 2016.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)48.8 ft × 16.1 ft × 6.4 ft
Registered tonnagegross 29 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTANFORD'S MARINE RAILWAY · COLONIAL BEACH, VA, UNITED STATES · built 1975
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCOLONIAL BEACH, VA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
4 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 4
26 August 2016
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5984063
18 May 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5881161
18 March 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5836127
14 March 2016
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5838877
Construction/Loadline › Hull › Bottom Plating
Issued 18 May 2016
No resolution recorded
Replace damaged section of planking on the exterior hull in way of the forward starboard section of the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2016
No resolution recorded
Complete all pending electrical work to include removing all dead-end wires.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016 — due date passed with no resolution recorded
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 18 May 2016
No resolution recorded
Repair floor work and decking located on the main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 May 2016
No resolution recorded
Repair the railing system located on the upper bridge; to ensure railing system is safe for passengers.
Due 18 June 2016 — due date passed with no resolution recorded
Engineering › Steering Gear System › Piping
Issued 18 May 2016
No resolution recorded
Remove jubilee patch (soft patch) and repair damaged section of hydraulic line located on the portside mid-section of the main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016 — due date passed with no resolution recorded
Stability › Watertight Integrity › General
Issued 18 May 2016
No resolution recorded
Vessel must conduct sea trials to receive credit for Dry dock exam.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Cable
Issued 14 March 2016
No resolution recorded
Determine cause of the fire in the Engine Compartment. Provide Report to attendign MI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Hull Plating
Issued 14 March 2016
No resolution recorded
Complete hull exam. Provide repair plan for deck replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 March 2016
No resolution recorded
Provide documentation of new battery installed. Provide repair proposal for damaged wire and documenation of new wire to be installed.
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 14 March 2016
No resolution recorded
Provide documentation of recharging Fire boy and spent CO2 extinguishers and report that the fireboy is adequately sized for the space.
Action required: 701 - Prior to carriage of passengers/cargo