07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 June 2026
No resolution recorded
Portable extinguishers must be inspected and maintained in accordance with NFPA 10. The portable CO2 extinguisher hoses in the pantry and outside of the engine compartment have not been labeled as required by NFPA 10 (2010) 7.3.1.3.2).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 June 2026
No resolution recorded
Each CO2 storage cylinder must meet the requirements of 46 CFR 147.60. The storage cylinders for the fixed CO2 fire extinguishing system have not been hydrostatically tested as required by 46 CFR 147.60.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew or other persons, and the vessel, from electrical hazards. The GFCI outlet above the sewage tank is damaged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026
Resolved 21 August 2026
Resolution: Replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 June 2026
Resolved
The installation of portable fire extinguishers must be to the satisfaction of the OCMI. The bracket in way of the portable fire extinguisher outside of the engine compartment is damaged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026
Resolved 21 August 2026
Resolution: Replaced
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 June 2026
Resolved
The fire pump outlet must be fitted with a gauge. The gauge at the fire pump outlet is partially painted over.
Action required: 10 - Deficiency Rectified
Resolved 24 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2026
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel’s name. The ring life bouy, main deck, starboard, aft, is not marked with the vessel’s name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026
Resolved 21 August 2026
Resolution: Name marked
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2026
Resolved
All electrical equipment and circuits must be clearly marked and identified. The distribution panels circuit lists in the pantry and engine compartment do not match the actual circuit arrangement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026
Resolved 21 August 2026
Resolution: Labeled
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2026
Resolved
Battery charges must have an ammeter connected in the charging circuit. The battery charger in way of the generator start batteries is not provided with an ammeter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026
Resolved 21 August 2026
Resolution: Ammeter installed
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 June 2026
Resolved
At each inspection for certification all observed unsafe practices shall be corrected. The valve in way of the fire pump overboard piping is leaking.
Action required: 10 - Deficiency Rectified
Resolved 24 June 2026
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 June 2026
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Stern light was extinguished.
Action required: 10 - Deficiency Rectified
Resolved 24 June 2026
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 June 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List. Chart, Light List, and Coast Pilot onboard are from 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026
Resolved 21 August 2026
Resolution: Updated copies onboard
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 June 2026
No resolution recorded
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Child PFD stowage is marked with incorrect number of PFDs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 June 2026
Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. Port and starboard fire hose were disconnected at time of inspection.
Action required: 10 - Deficiency Rectified
Resolved 24 June 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2026
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Screwdriver was found on top of battery that could have contacted terminals.
Action required: 10 - Deficiency Rectified
Resolved 24 June 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew or other persons, and the vessel, from electrical hazards. Starboard aft overhead outlet is missing a cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026
Resolved 21 August 2026
Resolution: Replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 June 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Starboard main engine exhaust lagging is oil soaked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2026
Resolved 21 August 2026
Resolution: Replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew or other persons, and the vessel, from electrical hazards. Starboard aft overhead outlet is missing a cover. Starboard generator power cable is pulled out of junction box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2026
Resolved 21 August 2026
Resolution: Repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2025
Resolved
Junction boxes for use in damp or wet locations shall be watertight. In stern space on fwd stbd wtb, a junction box is open with no securing hardware and has untapes wire nuts. Secure twist on nuts with tape and secure junction box with hardware.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 11 August 2025
Resolution: Witnessed satisfactory completion.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2025
Resolved
Electrical equipment on a vessel must be installed to proovide services necessary for safety under normal and emergency conditions. In stern space, mount new water pump feet to platform.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 11 August 2025
Resolution: Witnessed satisfactory completion.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2025
Resolved
Electrical equipment on a vessel must be installed to provide services necessary and minimize accidental personnel contact with energized parts. In stern space, remove old and unused water pump and dead end cable back to source.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 11 August 2025
Resolution: Witnessed satisfactory completion.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2025
Resolved
Electrical equipment on a vessel must be installed to minimize contact with energized parts. Switchboard door will not close and stay secured. Provide way to secure.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 11 August 2025
Resolution: Witnessed satisfactory completion.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2025
Resolved
Electrical equipment on a vessel must be installed to minimize contact with energized parts. In stern space ovhd, a light switch box is pulled apart and open. Restore and secure switch box.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 11 August 2025
Resolution: Witnessed satisfactory completion.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2025
Resolved
Electrical equipment on a vessel must provide services necessary for normal and emergency conditions. GFCI outlet next to fire detection panel is not working and box is loose. Restore GFCI operation and make box more secure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 11 August 2025
Resolution: Witnessed satisfactory completion.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 15 July 2025
Resolved
Galleys, serving spaces, and similar spaces may be examined to determine if they are serviceable and in sanitary condition. Ice maker machine door hinge area has mold and must be cleaned and disinfected.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 11 August 2025
Resolution: Witnessed satisfactory completion.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2025
Resolved
Unsafe practices, fire hazards, and other hazards must be corrected. Both genset battery boxes are full of oil/ lubricant/ coolant liquids. Remove contamination from boxes and wipe down batteries prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 July 2025
Resolution: Owner provided pictures of clean battery boxes and batteries.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2025
Resolved
A length of fire hose shall be attached to fire hydrant at all times. Both fire stations were found with fire hoses not attached.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2025
Resolution: Hoses attached to hydrants.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2025
Resolved
An adult life jacket must be provided for each person carried onboard. Vessel is restricted to 149 passengers until full complement of life jackets is provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 11 August 2025
Resolution: Witnessed satisfactory purchase and proper marking of 1 lifejacket to provide for full complement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2025
Resolved
The number and sizes of life jackets must be marked on each container for life jackets. The stbd fwd stowage does not indicate size of life jackets. The aft stowage does not have the correct number labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 11 August 2025
Resolution: Witnessed satisfactory completion.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2025
Resolved
Electrical equipment must be installed and maintained to protect passengers and crew from electrical hazards. At upper bar, a surge protector needs to be mounted on upper deck stbd side and outlet box is not mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 11 August 2025
Resolution: Witnessed satisfactory completion.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 15 July 2025
Resolved
The master of the vessel shall ensure EPIRB is tested monthly. The EPIRB has not been tested monthly.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 July 2025
Resolution: Master conducted and logged EPIRB test in presence of marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 July 2025
Resolved
Each distress signal must be stowed in a portable watertight container. The current container does not hold the number of distress signals required for the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 11 August 2025
Resolution: Witnessed satisfactory completion.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 July 2025
Resolved
Fire extinguishing equipment installed in excess of the requirements must be maintained. The smoke alarm in the stbd aft pilothouse is not operational. Repair or remove.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 15 July 2025
Resolution: Master removed smoke alarm from pilothouse.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2025
Resolved
Each floating water light must have a lanyard length between 3 and 6 feet. The fwd main deck ring buoy water light lanyard is wasted. Replace the same.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 11 August 2025
Resolution: Witnessed satisfactory completion.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2024
Resolved
Distribution panels and switchboards that are accessible from the rear must be constructed to prevent a person from accidentally contacting energized parts.
Clean out inside of switchboard cabinet and plug empty holes in that are open in the bottom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2025
Resolution: Switchboard cabinet in aft steering space was cleaned and open holes were plugged.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 August 2024
Resolved
The master of the vessel shall ensure that:
(c) The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable.
EPIRB tests have not been logged. Inspectors witnessed crew conducted and logged monthly test.
Action required: 10 - Deficiency Rectified
Resolved 27 August 2024
Resolution: Inspectors witnessed crew conducted and logged monthly test.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 27 August 2024
Resolved
A seat must be constructed to minimize the possibility of injury and avoid trapping occupants.
Several seats are fractured with sharp edges of fiberglass and allowing excessive flexing. Repair or replace broken seats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2025
Resolution: Broken seats were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 August 2024
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported.
Beverage system CO2 bottles were not secured on the upper deck bar area or in the lower galley area. Remove or secure loose bottles.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 23 October 2024
Resolution: Bottles were removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway.
An electric pump in the stern space is not mounted to the platform it sits upon. Mount electric pump footings to the platform with appropriate hardware.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 23 October 2024
Resolution: Pump was mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
In the stern space there is a deadened cable hanging from the overhead and a GFCI receptacle located above a battery charger that is not operational. Remove cable and remove, replace, or repair GFCI outlet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 23 October 2024
Resolution: Cable was removed and outlet was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts.
A battery charger in the stern space has a knock-out hole entry open and needs to be closed. Install appropriate knock-out plug for existing hole.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 23 October 2024
Resolution: Plug installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray.
The port genset starting battery box is full of coolant from maintenance conducted earlier. Master removed coolant from battery tray and wiped battery/terminals until residue free.
Action required: 10 - Deficiency Rectified
Due 27 August 2024
Resolved 27 August 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 August 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including inspection of the condition of the superstructure, masts, and similar arrangements constructed on the hull.
The forward masthead light post has fractured welds that need to be repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2025
Resolution: Cracked welds on masthead light post were repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
Electrical equipment exposed to the weather must be watertight.
The junction box for wire connections of the stern light system is missing its cover. Replace or renew junction box watertight cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 23 October 2024
Resolution: Junction box was replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 August 2024
Resolved
Each individual bilge suction line shall be provided with a check valve in at some accessible point in the bilge line.
The check valves for the crew, galley, and tank spaces cannot be located and/or are inaccessible. Locate the check valves in each individual bilge line and provide accessibility to the same.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2025
Resolution: Check valve installed in the bilge suction line for the tank space.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 August 2024
Resolved
An adult size life jacket must be provided for each person carried on board.
One Adult Type I life jacket was found unservicable. Replace the same.
Action required: 10 - Deficiency Rectified
Due 27 August 2024
Resolved 27 August 2024
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 August 2024
Resolved
The construction of a vessel must allow the safe operation of the vessel.
Two box frames in way of the upper deck support structure were found fractured. Make repairs to the same.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2025
Resolution: Upper deck support structure box frame cracked welds were repaired.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 August 2024
Resolved
The construction of a vessel must allow the safe operation of the vessel.
Two upper deck stiffeners, starboard side aft, were found with crack or incomplete welds. Make repairs to the same.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2025
Resolution: Upper deck stiffener cracked welds were repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 August 2024
Resolved
Each hatch exposed to the weather must be watertight.
The gaskets for watertight hatches in way of the stern space (port side) and engine room emergency escape (starboard side) on the aft main deck are damaged. Replace the same.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2025
Resolution: Gaskets on port and starboard aft hatches were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 August 2024
Resolved
At each reinspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected.
The mounting bracket for the ring buoy water light forward of the pilot house is not properly secured to the bulkhead. Secure the water light bracket to provide for safe removal of the water light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 23 October 2024
Resolution: Bracket mounted securely.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 27 August 2024
Resolved
At each reinspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected.
The LED lighting around the perimeter of the main deck in not properly secured creating a hazard for passengers and crew. Properly secure the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 23 October 2024
Resolution: Lighting was removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.
The stuffing tube for the cable feeding the overhead lighting on the main deck, aft, at the bottom of the stairway, is not properly inserted. Repair or replace the same.
Action required: 10 - Deficiency Rectified
Due 27 August 2024
Resolved 27 August 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.
The oval junction box located in the #2 compartment, starboard side, aft, is missing a plug at the bottom. Provide a plug for the same.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2025
Resolution: Hole in oval junction box in void #2, starboard side aft, was plugged.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 August 2024
Resolved
Each hatch exposed to the weather must be watertight.
The silicone provided to ensure watertight integrity of the deck hatches to the #1 and #2 voids is not watertight. Replace the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 23 October 2024
Resolution: New sealant on hatches.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 August 2024
Resolved
The construction of a vessel must allow the safe operation of the vessel.
There is a cracked weld on the underside of the deck in way of the access hatch. Make repairs to the same.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2025
Resolution: Cracked weld on underside of main deck near port aft hatch was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.
There is an unmounted surge protector on laying on the beverage cooler behind the upper deck bar. Properly mount the same.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 23 October 2024
Resolution: Surge protector removed
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 May 2024
Resolved
UNDERNEATH CENTER MDE THERE IS EXCESSIVE OIL IN THE BILGE. REMOVE OIL FROM THE BILGE PRIOR TO SAILING WITH PASSENGERS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2024
Resolution: MSU DMI received evidence that bilge area has been cleaned of oil/waste.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 May 2024
Resolved
A VESSEL ON A LAKES, BAYS AND SOUNDS OR RIVERS ROUTE MUST CARRY THREE HAND ORANGE SMOKE DISTRESS SIGNALS APPROVED IN ACCORDANCE WITH 160.037 IN SUBCHAPTER Q OF THIS CHAPTER. VESSEL IS MISSING THREE ORANGE FLARES OR EQUVILENTS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2024
Resolution: MSU DMI received evidence that vessel has procured proper distress signals for route.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The GFCI receptacle located next to the fire detection panel will not trip or reset properly for test. Replace or remove GFCI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2024
Resolved 27 August 2024
Resolution: Outlet replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. AFT STBD life ring grab line is deteriorated and broke. Replace grab line on life ring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2024
Resolved 27 August 2024
Resolution: Line replaced
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. In the stern space, a light switch box in the overhead is missing its cover. Replace cover on light switch box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2024
Resolved 27 August 2024
Resolution: Cover replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 May 2024
Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit. In the stern space, there is a cable spliced with a wire nut outside of an enclosure between an overhead light and its switch box. Replace spliced cable with new unspliced marine grade boat cable.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2024
Resolved 27 August 2024
Resolution: Replaced cable
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 May 2024
Resolved
Distribution panels and switchboards that are accessible from the rear must be constructed to prevent a person from accidentally contacting energized parts. The ground detection meter and voltage meter for #2 GEN on the SWBD are broken. Replace both meters on SWBD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 23 October 2024
Resolution: Meters were removed
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 May 2024
Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. Port side fire hydrant station did not have fire hose attached. Attach fire hose to hydrant station.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 May 2024
Resolution: Crew attached fire hose to station.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 May 2024
Resolved
Vessels described by 46 CFR 175.110(d) must ensure that the two means of escape required in paragraph (b) of this section are unobstructed and the door, hatch, or scuttle is not located directly above, or dependent on, a berth. Emergency egress behind bar was found blocked. Keep emergency egress area clear at all times.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 May 2024
Resolution: Crew removed blockage from means of escape area.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2023
Resolved
Remove surge trap from main deck and provide permanent outlet for speakers.
46 CFR 183.01-15
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2023
Resolution: Witnessed removal of the surge trap and installation of a permanent outlet for speakers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2023
Resolved
An extension cord on the main deck is being used as a permanent installation. Remove the same.
46 CFR 183.01-15
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2023
Resolution: Witnessed removal of extension cord.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2023
Resolved
The CO2 nozzle in way of the portable CO2 fire extinguisher in the dry stores area is cracked. Repair or replace the same.
46 CFR 181.120
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2023
Resolution: Witnessed satisfactory replacement of the CO2 extinguisher nozzle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2023
Resolved
The fuel shutoff handle in way of the starboard engine at the fuel filters is inoperable. Replace the same.
46 CFR 182.200
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2023
Resolved
The bilge suction pipe in the forward engine compartment is loose. Tighten couplings.
46 CFR 182.510
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2023
Resolution: The bilge suction couplings have been tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2023
Resolved
Secure oil drains for port and starboard main engine air/oil separator system.
46 CFR 182.200
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2023
Resolution: Oil drains for the air/oil seperator have been tightened and secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2023
Resolved
Provide cover for open space in distribution panel on the port aft side of the engine compartment (space #19).
46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2023
Resolution: Witnessed satisfactory installation of the blank cover fro distribution panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2023
Resolved
Remove debris from bilges though out to ensure bilge suctions do not become clogged.
46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2023
Resolution: Debris has been removed from bilge.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 August 2023
Resolved
The aluminum railing on the port aft side has two fractures. Repair the same to prevent pax/crew injury.
46 CFR 176.830
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2023
Resolution: Witnessed satisfactory repairs to the aluminum railing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2023
Resolved
Repair jacket water pressure sensor connection in way of starboard engine.
46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2023
Resolution: Jacket water pressure sensor has been properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2023
Resolved
Provide an three additional Type I Adult life jackets. The vessel is restricted to the carriage of 147 passengers pending completion.
46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 August 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 15 August 2023
Resolved
Adjust the hatch leading to the steering space to ensure proper closure.
46 CFR 176.830
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2023
Resolution: Witnessed proper operation of the steering space deck hatch.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2023
Resolved
Replace worn cable to starboard bow camera and ensure replacement cable is properly mounted.
46 CFR 183.300
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2023
Resolution: Witnessed replacement of worn cable for starboard bow camera.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 23 August 2022
Resolved
Any vessel of at least five net tons which engages in coastwise trade must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity engaged. The vessel's COD does not have a coastwise endorsement allowing the vessel to engage in unrestricted coastwise trade as defined in 46 CFR Part 67. Provide confirmation from NVDC that acknowledges receipt and confirms that all necessary paperwork and fees required to receive a coastwise endorsement for the vessel have been received.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2022
Resolution: Representative from NVDC contacted MSU Chicago and acknowledged Owner is taking the appropriate steps to secure a coastwise endorsement for the COD.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 11 August 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 2 August 2022
Resolved
Continue updating vessel name on EPIRB form, FCC License, and COD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 11 August 2022
Resolution: EPIRB registration has been updated. New requirement issued for COD and FCC Station License.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 August 2022
Resolved
Ensure all fire extinguishers brackets are proper type, Noticed improper brackets in wheelhouse and upper fly bridge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 2 August 2022
Resolved
Provide procedures to ensure count of passengers is documented ashore.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 August 2022
Resolution: Passenger count is documented with [name withheld] at [phone withheld]. A special note has been added documenting this number.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 August 2022
Resolved
No Donning placards onboard. Provide lifesaving donning placards near life jacket locations.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 August 2022
Resolution: Donning placards were provided and posted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 August 2022
Resolved
Remove and re-install proper chaffing gear on upper pilothouse hole.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 2 August 2022
Resolved
Tighten and install hardware on passenger seating on FWD STBD main deck and upper FWD STBD.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 August 2022
Resolved
Replace grab lines on 02 ring buoys, Renew 60’ of 5/16” floating line on AFT ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 August 2022
Resolved
Properly label alarm panel indicator lights in wheelhouse.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 August 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 August 2022
Resolved
Make repairs & prove proper operation of the watertight door indicator light at the operating station no later than 02Sep22.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Witnessed satisfactory operation of the watertight door indicator light at the operating station.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 2 August 2022
Resolved
Provide means of getting unconsious man-overboard safely onboard the vessel (e.g. LifeSling) no later than 02Sep22.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Witnessed evidence of purchase of LifeSling and installation of necessary appurtenances on the vessel. Inspector to conduct operational test with crew when received.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 19 July 2022
Resolved
Provide proof of crew enrollement in a drug and alcohol testing program & provide a written company drug and alcohol program.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2022
Resolution: All crew have been enrolled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 July 2022
Resolved
Provide proof of employee assistance program traing for the Master and crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2022
Resolution: Owner provided proof of EAP training for the crew.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 July 2022
Resolved
Replace the port side fire hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2022
Resolution: Fire hose replaced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 July 2022
Resolved
Prove proper operation of the fire detection panel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2022
Resolution: Fire detection panel replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 July 2022
Resolved
Provide lagging on the port and starboard generator exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2022
Resolved 2 September 2022
Resolution: Witnessed satisfactory installation of lagging on starboard generator. Port lagging onboard the vessel and will be installed following generator maintenance.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 July 2022
Resolved
Conduct monthly EPIRB test and log as required or remove the EPIRB from the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2022
Resolution: EPIRB has been tested monthly
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 July 2022
Resolved
Remove temporary batter charger arrangement and provide battery charger that complies with 46 CFR 183.350.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2022
Resolution: Battery charger has been replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 July 2022
Resolved
Conduct man-overboard, fire fighting, and abandon ship drills with ALL crewmembers in the presence of a marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2022
Resolution: Conducted drills with crew.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 19 July 2022
Resolved
Prior to serving as Master on ANY vessel, [name withheld] must provide a valid medical certificate issued by NMC.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2022
Resolution: Received proof of Med cert on duty phone, Cleared outstanding 835.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 July 2022
Resolved
Provide an Application for Inspection to the OCMI and undergo an Inspection for Certification conducted by a marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2022
Resolution: COI app rcvd, COI conducted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 July 2022
Resolved
Replace battery cover beneath the starboard generator.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2022
Resolution: Cover installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 June 2022
Resolved
#1 genset battery box and battery has oil all over it. Remove/ clean up oil.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 22 June 2022
Resolution: Oil was removed/cleaned up from battery box.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 June 2022
Resolved
Determine cause of oil leak on @1 genset and make repairs.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 22 June 2022
Resolution: Oil leak was determined to be loose connections. Connections made tight and oil cleaned up/removed from genset.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 June 2022
Resolved
Tank space and engine room have excessive oil in bilges. Remove excessive oil and complete general cleanliness of both spaces.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 22 June 2022
Resolution: Tank space and engine room had oil/rags/garbage removed from bilges. Excessive gear drift was removed from spaces.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 June 2022
Resolved
Provide annual service/inspection for all portable and fixed firefighting onboard.
CVC recommended that we use 46 CRFR 176.810(b) instead of the cite that was noted here.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 June 2022
Resolution: Portable and fixed firefighting had their annual services completed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 June 2022
Resolved
Fire detection panel has trouble alarm for lazeraette space and system needs annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 19 July 2022
Resolution: The fire detection panel was replaced. A new deficiency was issued to prove proper operation of the same as the panel was inoperable during the deficiency check.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 1 June 2022
Resolved
Replace gaskets for forepeak and crew space flush deck hatches.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Resolution: Silicone gasket material was made for hatch covers and applied to deck.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 1 June 2022
Resolved
Galley space forward WTB needs (3) holes filled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Resolution: 03 holes in WTB were filled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2022
Resolved
LED Light strips junction boxes below decks throughout vessel need cable entries made watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 August 2022
Resolution: J- Boxes corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 1 June 2022
Resolved
Galley overhead fan cord needs to be removed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 June 2022
Resolution: Crew removed fan during inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2022
Resolved
Galley volt panel needs general labeling on front and all breakers need proper labels.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Resolution: Galley power panel has been labeled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 June 2022
Resolved
Galley CO2 extinguisher needs to be relocated so not hidden, mount with proper bracket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 June 2022
Resolution: Galley CO2 extinguisher was relocated, SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2022
Resolved
Main deck decorative light string is missing lamps, Replace or remove.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 June 2022
Resolution: Lamps were replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 June 2022
Resolved
Tank room emergency light is not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Resolution: Batteries were replaced, emergency light is operational.
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 1 June 2022
Resolved
Tank room emergency escape hatch needs to be to labeled emergency escape , keep clear in block letters.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 June 2022
Resolution: Emergency escape was properly labeled during inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 1 June 2022
Resolved
Tank room ice machine is leaking water all over deck, make proper repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Resolution: Ice machine leaks have been secured, water cleaned up.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2022
Resolved
Tank room ice machine needs extension cord for power removed. Directly plug in or hardwire.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Resolution: Extension cord has been removed. Ice machine plugs into near by power outlet with it's origional appliance cord.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2022
Resolved
Tank room outlets near ice machine needs cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Resolution: Outlets have covers installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2022
Resolved
Engine room genset start battery covers need to be secured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Resolution: Port/Stbd genset battery box covers are now secured with ratched straps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2022
Resolved
Tank space/work room steel braided cable need to be supported.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Resolution: Steel braided cable is now supported.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 June 2022
Resolved
Complete vessel name needs to be marked on vessel PORT/STBD bow as per COI/COD. SIGHTSEER R.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2022
Resolution: The vessel name was changed to SIGHTSEER, a new COD was issued, and the vessel's name is properly marked on the hull.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 June 2022
Resolved
Provide proof that annual DAPI MIS report has been submitted to department of transportation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 July 2022
Resolution: The owner/operator can provide no records of a valid drug and alcohol test program and has insuffcient information to submit an MIS report. A new requirement was issued on 7/19/22 to provide a drug and alcohol testing program IAW 46 CFR Part 16.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 June 2022
Resolved
Post employee assistance program resources or comp[lie onboard for crew to have access.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2022
Resolution: Drug and Alcohol Program Information has been posted. However, owner/operator cannot provide proof of training required by 46 CFR Part 16. A new deficiency was issued to provide the same.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 1 June 2022
Resolved
Master needs to provide medical certificate and Marine radio ops permit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2022
Resolution: Master was able to provide a valid FCC Operators Permit. However, he has still not received a medical certificate from NMC. A new requirement was issued to provide the same.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 1 June 2022
Resolved
No Garbage placards posted, provide and post.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 June 2022
Resolution: A garbage placard was posted during inspection.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 June 2022
Resolved
No emergency drills are being logged or recorded. Conducted drills and properly record.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 August 2022
Resolution: Drlls have been recorded.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2022
Resolved
Vessel is missing one required adult life jacket. Vessel is reduced to 149 max passengers until new life jackets are procured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Resolution: New Type I life jacket provided, passenger count back to 150.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 June 2022
Resolved
In lazerette space, remove or tie down metal supply so it will not fall into steering arm/gear.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Resolution: Stock scrap metals that were in the space have been removed.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 1 June 2022
Resolved
Vessel needs to run machinery, conduct drills underway, test bilge suction, test fire fire stations, and test high water alarms with local OCMI prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 July 2022
Resolution: Conducted operational test of bilge suction, fire stations and high water alarms. A new deficiency was issued to conduct drills.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 23 July 2021
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] hatch from below deck lounge area is not marked. Mark with letters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR” on both sides to the satisfaction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 November 2021
Resolution: pictures provided
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 23 July 2021
Resolved
Each ladder used as a means of escape must be mounted. Escape hatch from below deck lounge area is not usable as there is no ladder. Ladder used for a means of escape must be mounted 7 inches from the nearest permanent object in back of the ladder. Rungs at least 16 inches in width, no more than 12 inches apart and at least 4.5 inches clearance above each rung. Submit proposal prior to installation to validate requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 November 2021
Resolution: Pictures provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 June 2021
Resolved
Vessel is restricted to only carrying 142 passengers due to only having 142 life jackets on board. 150 Adult and 16 children is required by the COI. Provide proof that 08 adult jackets have been added to vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 June 2021
Resolution: Jackets added to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2021
Resolved
Vessel is restricted to only carry 10 children until remaining required lifejackets are installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2021
Resolution: proper number of jackets were added.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2021
Resolved
Both fire stations need spanner wrenches and labeling installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 July 2021
Resolution: Stations were labeled and spanner wrenches were added.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 25 June 2021
Resolved
Repair ventilation closures on both PORT/STBD side.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 June 2021
Resolution: Fire Dampeners were repaired and operated properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2021
Resolved
Remove romex cable installed on overhead lights inside the passenger space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 July 2021
Resolution: Proper boat cable was installed.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 24 June 2021
Resolved
Crack identified on Laz hatch frame.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 July 2021
Resolution: Crack was welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 June 2021
Resolved
Repair or replace gauges at operating station. Gauges do not match local gauges.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 July 2021
Resolution: All OOC gauges were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 June 2021
Resolved
Fix coolant leak on #2 generator.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2021
Resolution: Coolant expansion tank cap replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 24 June 2021
Resolved
Re-label life jacket stowage boxes for “Adult and Child” jacket locations. Install proper donning placards for each style of jacket onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 July 2021
Resolution: Stowage locations were properly labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2021
Resolved
Vessel is not to carry passengers or operate until COI inspection is completed.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 June 2021
Resolution: Completed COI, withs defs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2020
Resolved
Each vessel must carry one floating water light. Vessel's water light was not operational and is restricted to daylight operation. Vessel must have an operational floating water light to the satisfaction of the Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 September 2020
Resolved 21 August 2020
Resolution: Vessel submitted photo of receipt and installation of new battery.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2020
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel have 01 extinguishers with expired servicing tags. Vessel must provide proof of annual servicing to the satisfaction of the Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 24 June 2021
Resolution: Verified that all extinguishers were serviced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 August 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Vessel did not have updated charts. Vessel must have procedure in place to update charts to the satisfaction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 24 June 2021
Resolution: Charts for local new AOR are onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 19 August 2020
Resolved
ach vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Vessel's emergency lighting was not operational and must be rectified to the satisfaction of the Marine Inspector
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 24 June 2021
Resolution: E-lighting was tested sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2020
Resolved
Where rigid nonmetallic material is permitted of use in piping systems the following restrictions apply: Penetrations of required water tight decks and bulkheads by any rigid plastic pipe are prohibited unless the following requirements are met: One or more metallic shutoff valves must be installed adjacent to the fitting. Vessel must install shutoff valves to the satisfaction of the Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2020
Resolved 23 July 2021
Resolution: Cleared this def for Sector Del Bay, will re-issue from MSU Chicago.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 19 August 2020
Resolved
For a life float—Approved under approval series 160.027. Retro reflective tape on top of the starboard life float must be replaced to the satisfaction of the Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 24 June 2021
Resolution: All life floats were removed from vessel and was restricted to not more than 1 mile from shore.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 19 August 2020
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed EPIRB hydrostatic release has passed expiration date. Replace with new hydrostatic release to the satisfaction of the Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 21 August 2020
Resolution: Vessel submitted photos of receipt and proper installation of hydrostatic release.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 19 August 2020
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] hatch from below deck lounge area is not marked. Mark with letters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR” on both sides to the satisfaction of the Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 23 July 2021
Resolution: Cleared this def for Sector Del Bay, will re-issue in MSU Chicago AOR.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 August 2020
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Two life jacket containers are not labeled. Label containers with items inside and sizes. Letters and numbers must be at least 50 millimeters (2 inches) high to the satisfaction of the Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2020
Resolved 24 August 2020
Resolution: Vessel submitted photos of newly marked lifejacket bins.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 19 August 2020
Resolved
Each ladder used as a means of escape must be mounted. Escape hatch from below deck lounge area is not usable as there is no ladder. Ladder used for a means of escape must be mounted 7 inches from the nearest permanent object in back of the ladder. Rungs at least 16 inches in width, no more than 12 inches apart and at least 4.5 inches clearance above each rung. Submit proposal prior
to installation to validate requirements.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2020
Resolved 23 July 2021
Resolution: Cleared def for Sector Del Bay, Will re-issue within MSU Chicago AOR.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 May 2019
Resolved
Provisions shall be made to close a ventilated space protected by a fixed fire protection system. Provide means to quickly manually close louvers to engine room. - 46 CFR 181.20-35
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2019
Resolved 30 May 2019
Resolution: Vessel Captain rigged a wire to a UL certified weak-link to have a manual way to close the e/r louvers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 May 2019
Resolved
Make cable run to engine room on the port side, forward, watertight. - 46 CFR 171.114
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2019
Resolved 30 May 2019
Resolution: Vessel owner plugged wire run hole in e/r.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 May 2019
Resolved
Replace waterlight batteries with new for those that are expired on the life floats. - 46CFR 180.175(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2019
Resolved 30 May 2019
Resolution: Vessel owner replaced all expired waterlight batteries with new ones.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 May 2019
Resolved
Instructions for operating the fixed fire system must be placed at or near each pull box, stop valve control, and in the space where the cylinders are stored. Provide specified instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2019
Resolved 30 May 2019
Resolution: Vessel owner posted operating instructions for his e/r CO2 system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 January 2019
Resolved
Vessel is unable to complete credit drydock inspection prior to scheduled date (31 Jan 2019). Vessel must complete credit drydock prior to carrying passengers. - 46 CFR 176.600
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2019
Resolution: Drydock extension granted on 21JAN2019.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 June 2018
Resolved
Conduct MOB and fire fighting drill prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2018
Resolution: Conducted satisfactory MOB and fire drill.
Engineering › Fuel Oil Service System › Hose
Issued 18 June 2018
Resolved
Remove and replace fuel line leading to generator fuel strainer with ASTM D1692 or SAE J1942 hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2018
Resolution: Hose replaced with SAE J1942 hose
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 18 June 2018
Resolved
Found missing lables for two circuit breakers in panel located in the galley space. Provide lables for two circuit breakers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2018
Resolution: Circuit breakers appropriately labled
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 June 2018
Resolved
Vessel has 14 child life preservers on board. Add 2 more child life preservers to meet 16 child life preserver requirement on COI. Vessel cannot carry more than 14 children or persons weighing less than 90lbs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 July 2018
Resolution: Received email from [name withheld] verifiying presence of 02 new child life preservers.
Communications › Radio Communications › EPIRB
Issued 18 June 2018
Resolved
Found EPIRB with expired battery. Provide EPIRB with a valid battery. Vessel shall remain within 3nm from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2018
Resolution: EPIRB replaced
Electrical › Lighting (service) › Lighting Fixture
Issued 30 April 2018
Resolved
Identified missing lightbulb and glass guard in engine room, port side. Replace lightbulb and glass guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2018
Resolution: lightbulb and glass guard installed
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 April 2017
Resolved
Provide fire servicing certificate showing proper operation of CO2 system and fire alarm system. 46CFR176.810(b)(2)/ Due 26April2017
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2017
Resolved 30 April 2017
Resolution: Received fire servicing certificate attesting to proper operation of fixed CO2 and fire alarm systems.
Communications › Radio Communications › EPIRB
Issued 12 April 2017
Resolved
Replace hydrostatic release on EPIRB. Operations are limited to 3NM from shore. Provide NOAA registration. 46CFR185.749/ Due 29April2017
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 30 April 2017
Resolution: Received current NOAA EPIRB registration and phot and receipt for hydrostatic release with proper expiration date marked.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 12 April 2017
Resolved
Provide updated tide tables and nautical charts for operating area. 46CFR184.420(a). Due 26April2017
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2017
Resolved 30 April 2017
Resolution: Received photo and receipt for current tide tables and nautical charts.
Engineering › Steering Gear System › Piping
Issued 4 April 2016
Resolved
Make vessel available for steering system inspection underway following grounding.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2016
Resolution: verified operation of steering system while underway. Fully exercise helm/rudders. verified operation and inspected for leaks in hydraulic lines. All sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 April 2016
Resolved
Conduct man overboard and fire drills underway to the satisfaction of CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2016
Resolution: Conducted drills; all sat-see narrative.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 4 April 2016
Resolved
Flammable and combustible liquid in the 4th compartment must be removed and shall not be in a space not intended for such storage. Containers were for gasoline but owner stated it was diesel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2016
Resolution: Diesel and oil was removed from the vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 4 April 2016
Resolved
Provide updated charts 12317 and 12316 covering area of operation.
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 3 May 2016
Resolution: Charts provided.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 4 April 2016
Resolved
Provide updated tide tables.
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 3 May 2016
Resolution: Tide tables provided.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 4 April 2016
Resolved
Throttle cables throughout the vessel must be properly supported and should not drape over equipment or machinery.
Due 18 April 2016
Resolved 3 May 2016
Resolution: Cables have been supported.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 4 April 2016
Resolved
provide company policy regarding drug and alcohol use in the workplace.
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 3 May 2016
Resolution: Company policy was found in the handbook and filled out by the master.
Stability › Watertight Integrity › General
Issued 4 April 2016
Resolved
Cable penetrations in watertight bulkhead located in the 2nd and 4th compartment must be watertight
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 3 May 2016
Resolution: Penetrations have been sealed.
Construction/Loadline › Hull › Stiffener
Issued 4 April 2016
Resolved
Repair cracked welds on the starboard side in the forepeak and second compartment.
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 3 May 2016
Resolution: Welds repaired.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 April 2016
Resolved
Provide arrangement to prevent the overflow of coolant on the overhead and deck plating.
Due 18 April 2016
Resolved 3 May 2016
Resolution: Vessel was provided with coolant overflow tanks which will prevent coolant from creating a hazardous deck.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 4 April 2016
Resolved
Provide evidence of inspection subject to Bridge-to Bridge Act epr 47 CFR 80.1005.
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 3 May 2016
Resolution: Vessel has onboard all required FCC Certs.