Records from 1985 to 2026. Most recent: inspection, 26 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 80
26 May 2026
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8351265
11 May 2026
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8371151
4 May 2026
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8359338
10 April 2025
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8109708
25 February 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8084957
6 February 2025
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8075658
25 November 2024
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8039662
11 March 2024
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7877218
6 February 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7853409
29 December 2023
Type not recorded
No type recorded · Station Manasquan Inlet · USCG East District (CGD-E) · Activity 7843566
2 October 2023
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7821922
6 February 2023
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7632865
3 January 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7615844
10 February 2022
Internal Structural Exam · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7390912
17 August 2021
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7288086
24 March 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7162908
17 February 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7141930
9 February 2021
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7136836
13 February 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6907881
12 February 2019
Annual Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6624710
9 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6505702
21 February 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6355615
14 February 2017
Administrative Inspection · COI Inspection · Deficiency Check · Drydock Exam · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6087937
23 February 2016
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5820067
14 August 2014
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4955386
25 March 2014
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4823426
17 February 2012
DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4246532
18 October 2010
Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3877850
24 March 2010
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3698227
10 March 2009
Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3430207
3 June 2008
Inclining Experiment
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3263558
10 April 2008
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3181094
18 March 2008
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3165871
15 March 2007
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2887834
15 March 2006
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2602772
28 February 2006
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2589425
14 March 2005
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2309605
29 January 2004
Hull Examination · Construction Oversight · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2010024
25 February 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1749357
25 March 2002
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1597453
21 February 2002
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1488011
16 March 2001
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1059795
27 March 2000
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 816464
16 March 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1048211
18 March 1999
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 810634
7 April 1998
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1123986
26 March 1998
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1123406
21 March 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1092229
1 April 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1078597
27 March 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1077688
27 March 1996
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1090276
22 March 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 828226
2 March 1995
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 862054
28 March 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 858886
4 March 1994
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 857666
22 March 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 836197
5 March 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 836195
25 March 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 950502
18 March 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 951623
9 March 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 952187
4 April 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1214184
5 March 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1220869
3 May 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 909461
19 March 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1243114
2 March 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 918580
12 April 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206864
14 March 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199473
3 March 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351253
30 March 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 994363
14 March 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991086
1 March 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1025807
11 March 1987
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321462
5 March 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321460
20 June 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 989499
26 March 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986215
24 March 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 996807
12 March 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993811
9 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 982254
19 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289837
12 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979461
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2026
Resolved
Where life preservers are stowed so that they are not readily visible to passengers, the containers in which they are stowed shall be marked “life preservers” and with the number contained therein, in at least 1-inch letters and figures. This legend shall indicate the separate stowage of children’s life preservers. No markings to identify location, number and size of life jackets was visible on stowage containers. Mark with the above information to the satisfaction of the MI.
46CFR185-30-10(a)
(OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 17 June 2026
Resolution: Posted lifejacket stensils with numbers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 May 2026
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The 10 B-C extinguisher in the wheelhouse was missed during annual servicing. Please provide servicing report to the satisfaction of MI.
46CFR176.810(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 3 June 2026
Resolution: Extinguisher serviced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 May 2026
Resolved
Examine and test by operation all watertight closures in the hull, decks and bulkheads. The watertight hatch going into the engine room was seen dripping water from the above use of the fire hose. Replace gasket and make watertight to the satisfaction of MI.
46CFR176-25-5
(OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 3 June 2026
Resolution: Replaced gasket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2026
Resolved
The marine inspector may require that the main propulsion machinery be operated both ahead and astern. The attached auxiliary machinery and cooling water system shall be checked. Water intake hose on STBD main engine was seen with multiple cracks. Replace hose to the satisfaction of MI.
46CFR176-25-10(a)(1)
(OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 3 June 2026
Resolution: Hose replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 May 2026
Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has not complete an annual inspection within the required timeline. Vessel shall not engage in any type of commercial operations until it has under gone an annual inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2026
Resolution: Vessel completed annual inspection 5/26
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 February 2025
Resolved
Vessel did not have interconnected fire detection and alarm system installed. Vessel is restricted to Limited Coastwise route until interconnected smoke detectors installed.
Action required: 705 - Other - as specified
Resolved 25 February 2025
Resolution: Vessel has installed required interconnected fire detection and tested to the satisfaction of the attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 February 2025
Resolved
Vessels Bridge to Bridge FCC certificate was expired. Vessel is restricted to operate within 1000ft until valid certificate is in affect.
Action required: 705 - Other - as specified
Resolved 9 April 2025
Resolution: Vessel was provided an updated Bridge-to-Bridge by FCC Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 February 2025
Resolved
05 adult and 06 child life jackets were found deteriorated and need replacing. Vessel is restricted to 149 total persons and 10 children until replaced.
Action required: 705 - Other - as specified
Resolved 25 February 2025
Resolution: Lifejackets acquired, and inspected by attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 February 2025
Resolved
Vessel had outdated Light List publication from 2019. Provide updated Light list for 2025.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: 2024 Light list has been acquired.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 February 2025
Resolved
First Aid kit had expired eye wash and ammonia inhalants and was missing burn gel, and aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: All missing medical items have been purchased and first aid kit updated.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 February 2025
Resolved
Starboard side fire station was missing spanner wrench. Provide spanner wrench at fire station as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Spanner wrench acquired and verified by attending MI
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 11 February 2025
Resolved
Secondary means of escape from crew accommodation, boiler room, and engine room were inoperable from interior. Maintain escape hatches to ensure fully functionality as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Secondary escape hatch has been rectified and works accordingly to the satisfaction of the attending MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 February 2025
Resolved
#1 and #2 ship generators had oil soaked coil windings. Clean windings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: both #1 and #2 generators coil windings have been cleaned satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 February 2025
Resolved
Switchboard latch on Forward E/R bulkhead was missing. Install latch for panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Latch for switchboard has been installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 February 2025
Resolved
Circuit breaker panel on aft bulkhead of E/R was missing a blank. Install blank on panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Blank panel on circuit breaker has been installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 February 2025
Resolved
Structural fire protection insulation was falling off in boiler space overhead, and on E/R hatch. Secure and or add insulation to identified areas.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Corrected to satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 February 2025
Resolved
EPIRB hydrostatic release unit was expired.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2025
Resolution: Vessel replaced with new onsite.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 February 2025
Resolved
Vessel was missing 04 smoke distress signals at the operating station.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2025
Resolution: Vessel replaced with new smoke signals onsite.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 February 2025
Resolved
Lettering of vessels name on life float paddles were faded off.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2025
Resolution: Vessel marked paddles on site.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 February 2025
Resolved
Life ring floating water light was clipped to grab line and not secured around life ring body.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2025
Resolution: Life ring light arrangement was placed correctly on site.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 11 February 2025
Resolved
Vessels Marine Sanitation Device Type III system did not have locked overboard valve.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2025
Resolution: MSD valve locked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2025
Resolved
The owner of a vessel subject to inspection under Section 3301 shall record in a log book information on all access and use of the vessel's master key, including
A)dates and times of access
B)the room or location accessed; and
C)the name and rank of the crew member that used the
master key.
Vessel had no record for master key control.
Provide master key control as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Vessel master key book rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 February 2024
Resolved
Each survival craft so that when the vessel sinks the survival craft floats free. The painters for the lifefloats were coiled and bundled using short lengths of line that would prevent the painter from unfurling.
CORRECTED ON THE SPOT
46 CFR 180.130(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2024
Resolution: Line was removed and corrected on the spot.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 6 February 2024
Resolved
At each inspection, the marine inspector may require that a man overboard drill be held. Crew uses a life sling as part of their procedure to recover people from the water. Life sling is missing the 3 to 1 block for hoisting a victim to the deck.
46 CFR 176.808(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 11 March 2024
Resolution: Vsl has a new block for the block and tackle needed for the rescue sling.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 February 2024
Resolved
Penetrations in watertight bulkheads must have means to makie them watertight. There is an open stuffing tube in the watertight bulkhead between the boiler space and the crew space. Make this stuffing tube watertight.
46 CFR “Old S” 171.114(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 11 March 2024
Resolution: Penetration was filled with 5200 (watertight caulking).
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 February 2024
Resolved
Each penetration through a watertight bulkhead must have means to make them watertight. There is an unused pipe penetrating the collision bulkhead. Place a permanent cap on the end of the pipe.
46 CFR “Old S” 171.090
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 11 March 2024
Resolution: Penetration was capped using a metal threaded cap.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 February 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. 40 CFR 180.64
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2023
Resolution: Owner provided proof of EPIRB Registration. See documents for photo of EPIRB with valid sticker and order details.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 February 2021
Resolved
All wiring joints and splices shall be made in a junction boxes. Remove dead end wiring located in lazarette compartment, near both head entrances just below the upper deck overhang, and above the entrance to the engine room; or have the wires terminate inside of a junction box. - 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 17 February 2021
Resolution: Corrected during DD/ISE and verified by attending inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 February 2020
Resolved
Obtain 2 spanner wrenches for the fire stations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2020
Resolved 2 March 2020
Resolution: Vessel purchased 2 spanner wrenches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 February 2020
Resolved
Repair small jacket water leak on the #2 engine at dry dock.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2020
Resolved 2 March 2020
Resolution: Owner sent a receipt showing that a mechanic fixed the leak in the jacket water pipe.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 February 2020
Resolved
Obtain 5 replacement life jackets for the ones we condemned.
Action required: 10 - Deficiency Rectified
Due 13 February 2020
Resolved 13 February 2020
Resolution: Corrected prior to the completion of the inspection.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018
Resolved
Vsl is broadcasting: Incorrect NAME and no static draft information.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 13 February 2019
Resolution: Vessel entered draft into AIS
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 February 2016
Resolved
LK01: All lifejackets must be in servicable conditions. 68 life jackets need to be replaced. 46CFR 180.71a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 9 March 2016
Resolution: New life jackets were on board with lights and proper markings.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 February 2016
Resolved
LK02: Vessel must have current employee assistance drug program and company drug policy. 46CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 9 March 2016
Resolution: Observed current company policy on board.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 August 2014
Resolved
Vessel observed operating with 3 of the 4 crew members not enrolled in company DAPI program.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 14 August 2014
Resolution: Crew members were provided that were enrolled and compliant with the company’s DAPI program.
Lifesaving › Lifefloat › Float Free
Issued 14 August 2014
Resolved
Vessel observed operating with 3 of 5 lifefloats covered.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 14 August 2014
Resolution: Crew untied and removed covers from the lifefloats.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 25 March 2014
Resolved
Gauge not operable on vsl fire pump. Prove proper operation of vsl fire pump and gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2014
Resolved 14 April 2014
Resolution: Items cleared by [name withheld]
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 March 2014
Resolved
Conduct and log remedial MOB and Fire Drill training with ALL crew focusing on communication and POW Recovery from rescue platform NLT 04Apr2014.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2014
Resolved 14 April 2014
Resolution: Items cleared by [name withheld]
Engineering › Pressure Vessel › Relief Valve
Issued 25 March 2014
Resolved
Conduct testing and or Provide documentation of testing and maintinace of bolier and pressure relief valve NLT 04-04-14
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2014
Resolved 26 March 2014
Resolution: Tech report recived verifying the following: Boiler was serviced and checked per CG/CFR standards. Boiler relief valve, low water cut off, temp control, ALL SAT
Lifesaving › Lifefloat › Serviceable
Issued 1 March 2012
Resolved
2 lifefloats had gouges in the surface. Owner was given 45 days to make repairs using a certified [name withheld] repair kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2012
Resolved 23 April 2012
Resolution: Lifefloats put back into proper service.
Documentation › Markings/Placards › Warning Signs
Issued 1 March 2012
Resolved
Fuel shut offs were not marked properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2012
Resolved 23 April 2012
Resolution: New fuel shut off placards were installed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 February 2012
Resolved
Raw water intake hoses need a second clamp/fastener installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 23 April 2012
Resolution: Both clamps were replaced on the raw water intake pipe.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 2 April 2009
Resolved
Provide proof of drug/alcohol program.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 3 April 2009
Resolution: Vessel owner/operator provided proof of drug/alcohol enrollment.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 2 April 2009
Resolved
Provide 2009 Tide/Current Tables.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 3 April 2009
Resolution: 2009 Tide/Current Tables placed in service onboard vessel.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 April 2009
Resolved
Replace lifeline on life ring buoys
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2009
Resolution: Owner replaced lifelines on ring buouys.
Engineering › Pressure Vessel › Tubing
Issued 2 April 2009
Resolved
Replace the connector for temperature control on boiler with proper connector.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 3 April 2009
Resolution: Connector replaced on boiler.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 2 April 2009
Resolved
Secure anchor in #2 compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 3 April 2009
Resolution: Anchor securely fastened in #2 compartment.
Lifesaving › Lifefloat › Float-free Link
Issued 15 March 2007
Resolved
Provide weak link for 5th life float.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 22 March 2007
Resolution: Weak link procured and properly installed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 15 March 2007
Resolved
Provide proper covers for 110 volt outlets and panel in galley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 22 March 2007
Resolution: New covers installed.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 15 March 2007
Resolved
Make proper repairs to cracked frame on #1 hold, on the 3rd frame. Small 1" crack on the port side of the keel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 22 March 2007
Resolution: Frame had been properly repaired.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 March 2007
Resolved
Owner to complete and log required training and drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 23 July 2007
Resolution: Received a fax of the bridge/training log. Drills are being logged.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 15 March 2007
Resolved
Provide proof of NOAA registration for the EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 22 March 2007
Resolution: NOAA registration received and new sticker affixed to EPIRB.
Construction/Loadline › Hull › Weld
Issued 15 March 2006
Resolved
Found numerous cracked welds (details in narrative), yard to grind to original metal, clean out and re-weld.
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 31 March 2006
Resolution: corrected.
Engineering › Bilge Water Management System › Valve
Issued 28 February 2006
Resolved
Install check valves in bilge piping system at the manifold or suction strainer for each space.
Action required: 705 - Other - as specified
Due 16 March 2006
Resolved 15 March 2006
Resolution: Installed at the strainers.
Engineering › Freshwater System (intermediary cooling) › Hose
Issued 28 February 2006
Resolved
Properly replace dry rotted R/W hoses (3) located above each reduction gear.
Action required: 705 - Other - as specified
Due 16 March 2006
Resolved 15 March 2006
Resolution: corrected
Construction/Loadline › Structures › Transverse Bulkhead
Issued 28 February 2006
Resolved
Properly seal stuffing tubes on stbd side bulkhead #3, fwd of E/R.
Due 18 March 2006
Resolved 16 March 2006
Resolution: corrected
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 28 February 2006
Resolved
Properly repair small R/W leak in stbd exhaust piping located on weld seam.
Due 18 March 2006
Resolved 16 March 2006
Resolution: corrected
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 28 February 2006
Resolved
Properly install MSD overboard discharge valve. Handle turned 90 deg out. Appears closed when open.
Due 18 March 2006
Resolved 16 March 2006
Resolution: Valve handle installed properly and lock installed when operating with in 3 nm.
Electrical › Lighting (service) › Switch
Issued 25 February 2003
Resolved
Install proper switch cover on heating boiler controller.
Due 27 March 2003
Resolved 25 February 2003
Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 25 February 2003
Resolved
Install wire hangers on loose wiring for transducers on port and stbd sides of #3 compartment. LEGACY COMPONENT DESC: wiring
Due 27 March 2003
Resolved 25 February 2003
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 25 February 2003
Resolved
Obtain Man Overboard Harness for retrieval of person in water, and modify retrieval ladder with platform.
Due 27 March 2003
Resolved 25 February 2003
Lifesaving
Issued 27 March 1996
Resolved
THE VESSEL IS LIMITED TO A TOTAL OF 116 PERSONS, 4 OF WHICH MAY BE CHILDREN, UNTIL 38 ADULT AND 12 CHILDREN ADDITIONAL LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 27 May 1996
Resolved 1 May 1996
Accommodation/Occupational Safety
Issued 2 March 1995
Resolved
PERMANENTLY REPAIR MSD VENT CONNECTION TO MSD TANK TOP.
Condition: Unknown
Due 2 March 1995
Resolved 2 March 1995
Fire Fighting
Issued 4 March 1994
Resolved
HYDRO-TEST TWO (02) B-II CO2 PORTABLE FIRE EXTINGUISHERS NO PASSENGERS SHALL BE CARRIED ON BOARD UNTIL REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Lifesaving
Issued 5 March 1993
Resolved
STENCIL LIFE PRESERVER CONTAINERS WITH NUMBER OF PFD'S._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 April 1993
Resolved 5 April 1993
Fire Fighting
Issued 5 March 1993
Resolved
PROVIDE OPERABLE FIRE EXTINGUISHER IN THE ENGINE ROOM. EXTINGUISHER IS SAT UNTIL THE LAST DAY OF MARCH, 1993.
Condition: Unknown
Due 5 April 1993
Resolved 5 April 1993
Lifesaving
Issued 5 March 1993
Resolved
ATTACH PADDLES TO LIFERAFT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 April 1993
Resolved 5 April 1993
Construction/Loadline
Issued 18 March 1992
Resolved
VEE AND WELD BOTTOM OF KEEL APPROXIMATELY 18" AT STERN. TO BE COMPLETED TOSATISFACTION OF ATTENDING MARINE INSPECTOR, OR PICTURES OF CORRECTED AREA SUBMITTED TO [name withheld].
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Construction/Loadline
Issued 18 March 1992
Resolved
VEE AND WELD FLOOR FORWARD FLOOR FRAME IN NUMBER 2 COMPARTMENT TO BE COMPLETED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Construction/Loadline
Issued 18 March 1992
Resolved
VEE AND WELD IN FORWARD PEAK TAK AT STORAGE RACK FRAME - STBD SIDE. TO BE COMPLETED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Navigation
Issued 9 March 1992
Resolved
REPLACE ALL NAVIGATION LIGHTS WITH APPROVED TYPE.
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Navigation
Issued 9 March 1992
Resolved
PROVIDE UP-TO-DATE TIDE TABLE, AND CHARTS FOR AREA OF OPERATION.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Accommodation/Occupational Safety
Issued 9 March 1992
Resolved
REPLACE PORT AND STBD PIPING LEADING TO MSD, HOLDING TANK, APPROXIMATELY 4 FT.
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Electrical
Issued 9 March 1992
Resolved
PROVE PROPER OPERATION OF STBD GENERATOR.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Lifesaving
Issued 9 March 1992
Resolved
PROVIDE RESCUE BOAT OR SUITABLE RESCUE PLATFORM.
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Electrical
Issued 9 March 1992
Resolved
LABEL ELECTRIC POWER PANELS ON BRIDGE. PLACE BLANK IN POWER PANEL IN GALLEY.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Electrical
Issued 9 March 1992
Resolved
RENEW OR REPLACE PORT AND STBD GENERATOR BATTERY BOXES.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Engineering
Issued 9 March 1992
Resolved
REPLACE FLAME SCREEN FOR DIESEL TANK VENT.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Fire Fighting
Issued 19 March 1990
Resolved
PROVIDE PRESSURE GAUGE TO DISCHARGE SIDE OF MAIN FIRE PUMP.
Condition: Unknown
Due 19 March 1990
Resolved 19 March 1990
Engineering
Issued 14 March 1989
Resolved
LABEL EMERGENCY FUEL SHUT-OFF VALVE LOCATED IN AFT ACCOMODATION SPACE.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Fire Fighting
Issued 14 March 1989
Resolved
HYDROSTATICALLY TEST THE B-II FIRE EXTINGUISHER LOCATED IN ACCOMODATION SPACE (FWD).
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Construction/Loadline
Issued 14 March 1989
Resolved
INSTALL A SIGN ON BOTH SIDES OF WATERTIGHT DOOR LOCATED IN #2 COMPARTMENT STATING THAT DOOR MUST BE KEPT CLOSED AT ALL TIMES.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Electrical
Issued 14 March 1989
Resolved
PROPERLY LABEL ALL SWITCHES ON ELECTRICAL PANELS ON BRIDGE AND ACCOMODATIONSPACES.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Fire Fighting
Issued 14 March 1989
Resolved
SERVICE B-I FIRE EXTINGUISHER LOCATED IN PILOTHOUSE.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Navigation
Issued 14 March 1989
Resolved
OBTAIN CURRENT COPIES OF THE TIDE/CURRENT TABLES, US COAST PILOTS FOR YOUR OPERATING AREA AND THE COAST GUARD LIGHT LIST.
Condition: Unknown
Due 14 March 1989
Resolved 14 March 1989
Fire Fighting
Issued 14 March 1988
Resolved
RECHARGE THE 15 POUND BII CO2 FIRE EXTINGUISHER.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Lifesaving
Issued 14 March 1988
Resolved
MARK THE VESSEL'S LIFERING LOCATED ON THE UPPER DECK, WITH THE VESSEL NAME/HOMEPORT.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Lifesaving
Issued 14 March 1988
Resolved
REPLACE AND ATTACH THE LIFERING LINE. IT SHALL BE A LEAST 60 FT. OF BUOYANT MATERIAL.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Lifesaving
Issued 14 March 1988
Resolved
PROVIDE ONE CHILD PFD AS REQUIRED BY THE CERTIFICATE OF INSPECTION. THE VESSEL SHALL NOT CARRY MORE THAN FIFTEEN (15) CHILDREN UNTIL ITEM D-4 IS CLEARED.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Fire Fighting
Issued 14 March 1988
Resolved
PROVIDE AN OPERATIONAL TEST OF THE FIRE PUMP. THE VESSEL SHALL BE RESTRICT-ED FROM CARRYING PASSENGERS UNTIL THIS IS SATISFACTORILY CLEARED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 March 1988
Resolved 14 March 1988
Construction/Loadline
Issued 5 March 1987
Resolved
MAKE WATERTIGHT DOOR BETWEEN NO. 2 AND NO. 3 HOLDS WATERTIGHT.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Lifesaving
Issued 12 March 1986
Resolved
REPLACE LINE ON FOUR WATER LIGHTS ATTACHED TO B/A'S WHERE DETERIORATED.
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986
Accommodation/Occupational Safety
Issued 12 March 1986
Resolved
PROVIDE OPERATIONAL TEST OF (PV) RELIEF VALVE TO ENSURE IT FUNCTIONS BELOW MAWP OF (PV) WHICH IS 165 PSI.
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986
Lifesaving
Issued 19 March 1985
Resolved
D4 PROPERLY MARK ADULT LIFE PRESERVERS IAW 46 CFR 180.25-15 WHERE NOT MARKED, TEN (10) EACH.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Lifesaving
Issued 19 March 1985
Resolved
D3 PROVIDE PFD LIGHTS IAW 46 CFR 180.25-20 FOR FOUR (4) CHILDREN'S LIFEJACKETS WHERE MISSING.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Lifesaving
Issued 19 March 1985
Resolved
D2 PROPERLY MARK VESSEL'S LIFEFLOATS IAW 46 CFR 180.20-5.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Construction/Loadline
Issued 19 March 1985
Resolved
D1 PROVIDE SUITABLE AND SUFFICIENT GASKET MATERIAL TO COMPLETE GASKET INSTALLATION WHERE MISSING ON VESSEL'S WTD BELOW DECK.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Engineering
Issued 19 March 1985
Resolved
D10 PROVIDE FOR FIRESIDE EXAMINATION UNDER WORKING PRESSURE HYDROSTATIC TEST OF ALDRICH OIL FIRED HEATING BOILER.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Electrical
Issued 19 March 1985
Resolved
D8 PROVE PROPER OPERATION OF STARBOARD GENERATOR UNDERLOAD, INCLUDING PROPER OPERATION OF S/W COOLING TO ITS EXHAUST PIPING.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Fire Fighting
Issued 19 March 1985
Resolved
D9 REPAIR PIPING ON DISCHARGE SIDE OF STARBOARD FIRE/BILG PUMP WHERE LEAKING AT THE NIPPLE.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Fire Fighting
Issued 19 March 1985
Resolved
D7 PROVIDE ON-BOARD THE FOLLOWING AS CONCERNS THE VESSEL'S STARBOARD: FIRE STATION: ONE (1) 50FT. LENGTH OF APPROVED FIRE HOSE (1'/2") IAW 46 CFR 181.15-10; ONE (1) FIRE NOZZLE IAW 46 CFR 181.15-10(D)(2).
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Lifesaving
Issued 19 March 1985
Resolved
D5 PROVIDE ONE (1) RING BUOY ON BOARD IAW 46 CFR 180.30.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Lifesaving
Issued 19 March 1985
Resolved
D6 REPAIR OR REPLACE RING BUOY LOCATED ON AFT WHEELHOUSE SUPERSTRUCTURE PRESENTLY MISSING ATTACHED CIRCUMFERENTIAL LIFE LINES.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985