Records from 2016 to 2026. Most recent: inspection, 26 May 2026.
Inspection history · 24
26 May 2026
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8351265
11 May 2026
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8371151
4 May 2026
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8359338
10 April 2025
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8109708
25 February 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8084957
6 February 2025
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8075658
25 November 2024
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8039662
11 March 2024
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7877218
6 February 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7853409
29 December 2023
Type not recorded
No type recorded · Station Manasquan Inlet · USCG East District (CGD-E) · Activity 7843566
2 October 2023
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7821922
6 February 2023
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7632865
3 January 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7615844
10 February 2022
Internal Structural Exam · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7390912
17 August 2021
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7288086
24 March 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7162908
17 February 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7141930
9 February 2021
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7136836
13 February 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6907881
12 February 2019
Annual Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6624710
9 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6505702
21 February 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6355615
14 February 2017
Administrative Inspection · COI Inspection · Deficiency Check · Drydock Exam · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6087937
23 February 2016
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5820067
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2026
Resolved
Where life preservers are stowed so that they are not readily visible to passengers, the containers in which they are stowed shall be marked “life preservers” and with the number contained therein, in at least 1-inch letters and figures. This legend shall indicate the separate stowage of children’s life preservers. No markings to identify location, number and size of life jackets was visible on stowage containers. Mark with the above information to the satisfaction of the MI.
46CFR185-30-10(a)
(OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 17 June 2026
Resolution: Posted lifejacket stensils with numbers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 May 2026
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The 10 B-C extinguisher in the wheelhouse was missed during annual servicing. Please provide servicing report to the satisfaction of MI.
46CFR176.810(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 3 June 2026
Resolution: Extinguisher serviced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 May 2026
Resolved
Examine and test by operation all watertight closures in the hull, decks and bulkheads. The watertight hatch going into the engine room was seen dripping water from the above use of the fire hose. Replace gasket and make watertight to the satisfaction of MI.
46CFR176-25-5
(OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 3 June 2026
Resolution: Replaced gasket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2026
Resolved
The marine inspector may require that the main propulsion machinery be operated both ahead and astern. The attached auxiliary machinery and cooling water system shall be checked. Water intake hose on STBD main engine was seen with multiple cracks. Replace hose to the satisfaction of MI.
46CFR176-25-10(a)(1)
(OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2026
Resolved 3 June 2026
Resolution: Hose replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 May 2026
Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has not complete an annual inspection within the required timeline. Vessel shall not engage in any type of commercial operations until it has under gone an annual inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2026
Resolution: Vessel completed annual inspection 5/26
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 February 2025
Resolved
Vessel did not have interconnected fire detection and alarm system installed. Vessel is restricted to Limited Coastwise route until interconnected smoke detectors installed.
Action required: 705 - Other - as specified
Resolved 25 February 2025
Resolution: Vessel has installed required interconnected fire detection and tested to the satisfaction of the attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 February 2025
Resolved
Vessels Bridge to Bridge FCC certificate was expired. Vessel is restricted to operate within 1000ft until valid certificate is in affect.
Action required: 705 - Other - as specified
Resolved 9 April 2025
Resolution: Vessel was provided an updated Bridge-to-Bridge by FCC Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 February 2025
Resolved
05 adult and 06 child life jackets were found deteriorated and need replacing. Vessel is restricted to 149 total persons and 10 children until replaced.
Action required: 705 - Other - as specified
Resolved 25 February 2025
Resolution: Lifejackets acquired, and inspected by attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 February 2025
Resolved
Vessel had outdated Light List publication from 2019. Provide updated Light list for 2025.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: 2024 Light list has been acquired.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 February 2025
Resolved
First Aid kit had expired eye wash and ammonia inhalants and was missing burn gel, and aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: All missing medical items have been purchased and first aid kit updated.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 February 2025
Resolved
Starboard side fire station was missing spanner wrench. Provide spanner wrench at fire station as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Spanner wrench acquired and verified by attending MI
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 11 February 2025
Resolved
Secondary means of escape from crew accommodation, boiler room, and engine room were inoperable from interior. Maintain escape hatches to ensure fully functionality as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Secondary escape hatch has been rectified and works accordingly to the satisfaction of the attending MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 February 2025
Resolved
#1 and #2 ship generators had oil soaked coil windings. Clean windings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: both #1 and #2 generators coil windings have been cleaned satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 February 2025
Resolved
Switchboard latch on Forward E/R bulkhead was missing. Install latch for panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Latch for switchboard has been installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 February 2025
Resolved
Circuit breaker panel on aft bulkhead of E/R was missing a blank. Install blank on panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Blank panel on circuit breaker has been installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 February 2025
Resolved
Structural fire protection insulation was falling off in boiler space overhead, and on E/R hatch. Secure and or add insulation to identified areas.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Corrected to satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 February 2025
Resolved
EPIRB hydrostatic release unit was expired.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2025
Resolution: Vessel replaced with new onsite.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 February 2025
Resolved
Vessel was missing 04 smoke distress signals at the operating station.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2025
Resolution: Vessel replaced with new smoke signals onsite.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 11 February 2025
Resolved
Lettering of vessels name on life float paddles were faded off.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2025
Resolution: Vessel marked paddles on site.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 February 2025
Resolved
Life ring floating water light was clipped to grab line and not secured around life ring body.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2025
Resolution: Life ring light arrangement was placed correctly on site.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 11 February 2025
Resolved
Vessels Marine Sanitation Device Type III system did not have locked overboard valve.
Action required: 10 - Deficiency Rectified
Resolved 11 February 2025
Resolution: MSD valve locked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2025
Resolved
The owner of a vessel subject to inspection under Section 3301 shall record in a log book information on all access and use of the vessel's master key, including
A)dates and times of access
B)the room or location accessed; and
C)the name and rank of the crew member that used the
master key.
Vessel had no record for master key control.
Provide master key control as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2025
Resolved 25 February 2025
Resolution: Vessel master key book rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 February 2024
Resolved
Each survival craft so that when the vessel sinks the survival craft floats free. The painters for the lifefloats were coiled and bundled using short lengths of line that would prevent the painter from unfurling.
CORRECTED ON THE SPOT
46 CFR 180.130(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2024
Resolution: Line was removed and corrected on the spot.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 6 February 2024
Resolved
At each inspection, the marine inspector may require that a man overboard drill be held. Crew uses a life sling as part of their procedure to recover people from the water. Life sling is missing the 3 to 1 block for hoisting a victim to the deck.
46 CFR 176.808(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 11 March 2024
Resolution: Vsl has a new block for the block and tackle needed for the rescue sling.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 February 2024
Resolved
Penetrations in watertight bulkheads must have means to makie them watertight. There is an open stuffing tube in the watertight bulkhead between the boiler space and the crew space. Make this stuffing tube watertight.
46 CFR “Old S” 171.114(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 11 March 2024
Resolution: Penetration was filled with 5200 (watertight caulking).
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 February 2024
Resolved
Each penetration through a watertight bulkhead must have means to make them watertight. There is an unused pipe penetrating the collision bulkhead. Place a permanent cap on the end of the pipe.
46 CFR “Old S” 171.090
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2024
Resolved 11 March 2024
Resolution: Penetration was capped using a metal threaded cap.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 February 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. 40 CFR 180.64
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2023
Resolution: Owner provided proof of EPIRB Registration. See documents for photo of EPIRB with valid sticker and order details.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 February 2021
Resolved
All wiring joints and splices shall be made in a junction boxes. Remove dead end wiring located in lazarette compartment, near both head entrances just below the upper deck overhang, and above the entrance to the engine room; or have the wires terminate inside of a junction box. - 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 17 February 2021
Resolution: Corrected during DD/ISE and verified by attending inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 February 2020
Resolved
Obtain 2 spanner wrenches for the fire stations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2020
Resolved 2 March 2020
Resolution: Vessel purchased 2 spanner wrenches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 February 2020
Resolved
Repair small jacket water leak on the #2 engine at dry dock.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2020
Resolved 2 March 2020
Resolution: Owner sent a receipt showing that a mechanic fixed the leak in the jacket water pipe.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 February 2020
Resolved
Obtain 5 replacement life jackets for the ones we condemned.
Action required: 10 - Deficiency Rectified
Due 13 February 2020
Resolved 13 February 2020
Resolution: Corrected prior to the completion of the inspection.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018
Resolved
Vsl is broadcasting: Incorrect NAME and no static draft information.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 13 February 2019
Resolution: Vessel entered draft into AIS
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 February 2016
Resolved
LK01: All lifejackets must be in servicable conditions. 68 life jackets need to be replaced. 46CFR 180.71a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 9 March 2016
Resolution: New life jackets were on board with lights and proper markings.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 February 2016
Resolved
LK02: Vessel must have current employee assistance drug program and company drug policy. 46CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2016
Resolved 9 March 2016
Resolution: Observed current company policy on board.