MAURY USCG vessel records
← All vessels

MOC VI

Built
1975
Last inspected
30 June 2010
Documentation
No Operation - PM · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 30 June 2010
…with no type recorded44
Operational controls None recorded without a removal date
Years with a record 28 calendar years (1983–2010)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-48389

Documentation record

Registered dimensions (L × B × D)275.0 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 1,916 / net 1,916
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNASHVILLE BRIDGE COMPANY · NASHVILLE TN, UNITED STATES · built 1975
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCORPUS CHRISTI, TX
Endorsements, as the file codes themcw_un
DocumentationNo Operation - PM · issued 27 July 2011 · expires 31 August 2012
Service, as the file records itTank Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1916 - Regulatory (Subpart C or D), Gross Ton
1916 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 88 inspections, each with its date, unit and type; 31 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MOC 12 Tank Barge · MISLE 52527 · 19 June 2009 · activity 3510694MISS AUDREY Towing Vessel · MISLE 191040 · 19 June 2009 · activity 3510694MOC VII Tank Barge · MISLE 48466 · 17 February 2006 · activity 2587265MISS AUDREY Towing Vessel · MISLE 191040 · 17 February 2006 · activity 2587265WISCONSIN Towing Vessel · MISLE 137637 · 13 June 1996 · activity 57692

Inspection history · 88

30 June 2010 Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3809075
7 June 2010 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3760390
17 July 2009 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3537342
19 June 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3510694
27 January 2009 Examination of Repairs · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3400369
6 January 2009 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3389295
7 January 2008 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3126132
18 December 2007 Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3117785
20 February 2007 Periodic Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2874575
17 February 2006 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2587265
12 December 2005 Annual Inspection · MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2549943
15 February 2005 Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2292728
14 February 2005 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2292238
10 December 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2256925
7 December 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2255311
27 October 2004 MTSA Verification · COI Inspection · Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2220570
24 September 2004 Deficiency Check · Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2203362
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1972174
18 August 2003 Deficiency Check · Periodic Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1876306
18 June 2002 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1621799
19 July 2001 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1362352
20 March 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 526995
7 March 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1494731
9 June 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1050372
19 May 2000 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1441618
22 June 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 500650
6 May 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 793675
15 April 1999 Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1418519
16 December 1998 Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 808469
11 October 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 534157
31 March 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1372195
14 September 1997 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 505759
18 April 1997 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1442547
3 July 1996 Examination of Repairs
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1086646
13 June 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 57692
13 June 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 881927
10 May 1996 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1400350
28 November 1995 Examination of Repairs
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1192626
28 June 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 119974
1 May 1995 Hull Examination · COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1176499
16 March 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 467486
9 February 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 496958
1 December 1994 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412717
17 October 1994 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 515349
1 June 1994 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 861387
11 March 1994 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 855407
9 March 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399987
15 February 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 478945
14 June 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 448400
7 April 1993 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 533293
29 March 1993 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1145647
16 February 1993 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1395894
26 January 1993 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 510545
21 September 1992 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 482446
9 March 1992 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 944347
12 January 1992 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 436809
9 December 1991 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 473214
9 November 1991 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 456588
22 September 1991 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 538652
8 September 1991 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 531721
15 May 1991 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 913854
2 April 1991 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1227644
30 January 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 462516
13 December 1990 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1239818
18 July 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 493499
4 April 1990 COI Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1218315
18 September 1989 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 442154
7 April 1989 Examination of Repairs
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1197567
20 March 1989 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1208964
8 December 1988 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 448689
25 August 1988 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 325366
27 April 1988 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 538052
27 January 1988 MARPOL Annex II Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023578
8 September 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 506580
4 June 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 469437
1 May 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 527921
31 March 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 461760
25 March 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327522
19 March 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 533455
15 September 1986 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 520793
29 May 1986 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 987391
8 June 1985 Type not recorded
No type recorded · MSO CINCINNATI · Activity 441012
8 June 1985 Type not recorded
No type recorded · MSO CINCINNATI · Activity 512786
2 April 1985 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 980999
26 August 1984 Type not recorded
No type recorded · MSO CINCINNATI · Activity 516237
29 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280374
21 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274258
18 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969354

Deficiency record · 31

Construction/Loadline › Hull › Hull Plating
Issued 6 January 2009 Resolved
Crop and renew the wasted deck plating on the center topside of the bow rake to good metal to the satisfaction of the CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2009
Resolution: Witnessed satisfactory air test of renewed deck plating over the center topside of the bow rake.
Deck/Cargo › Cargo Heating › General
Issued 6 January 2009 Resolved
Within 30 days, prove proper operation of thermal fluid heater to the satisfaction of CG marine inspector or provide proposal to take thermal fluid heater out of service.
Condition: Unknown
Due 6 February 2009
Resolved 27 January 2009
Resolution: Expansion joings on the thermal fluid heater were removed and all ends were flanged.
Deck/Cargo › Cargo Heating › General
Issued 7 January 2008 No resolution recorded
Prove proper operation of Thermal Fluid Heater prior to carrying cargoes needing to be heated.
Action required: 705 - Other - as specified
Resolution: Wrote new requirement on 6 January 2009.
Deck/Cargo › Cargo Stowage › General
Issued 7 January 2008 Resolved
Renew #1 port PV post.
Action required: 705 - Other - as specified
Resolved 9 January 2008
Resolution: New post has been properly installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 January 2008 Resolved
Remove unused electrical cables on deck.
Action required: 705 - Other - as specified
Resolved 9 January 2008
Resolution: Electrical cables have been removed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 7 January 2008 Resolved
Conduct annual hydrostatic tests of cargo piping.
Action required: 705 - Other - as specified
Resolved 9 January 2008
Resolution: Contractors performed a hydrostatic test of cargo piping, all sat.
Deck/Cargo › Cargo Stowage › General
Issued 18 December 2007 Resolved
see worklist items in narrative for # 6 stbd, # 6 port and #2 port cargo tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2008
Resolution: Worklist items have been corrected.
Construction/Loadline › Hull › Bracket
Issued 18 December 2007 Resolved
see worklist items listed in narrative.
Action required: 705 - Other - as specified
Resolved 9 January 2008
Resolution: Worklist items have been corrected.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 February 2007 Resolved
Guard on prime mover is loose and fractured at welds. Replace guard.
Due 15 March 2007
Resolved 20 February 2007
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 20 February 2007 Resolved
Valves to cargo header were loose, nut to threaded handle was missing. Replace nuts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2007
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 24 September 2004 Resolved
Failure to comply with terms and/or endorsements of the certificate of inspection for a tank vessel. Vessel was operated at least 1 year, 9 months in salt water service while under fresh water service examination interval. Vessel owner did not notify the cognizant OCMI when this change in status occurred.
Action required: 705 - Other - as specified
Resolved 21 October 2004
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 24 September 2004 Resolved
Failure to conduct annual or periodic inspection of a tank vessel, 1600 GT or more. Vessel found to be significantly past due for an annual inspection on 24SEP04. COI anniversary date was 19MAY04.
Action required: 705 - Other - as specified
Resolved 21 October 2004
Deck/Cargo › Holds/Tanks
Issued 18 August 2003 Resolved
Renew broken handles on #1S and #3P Sluice valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 3 September 2003
Resolution: Broken handles on #1S and #3P sluice valves renewed.
Deck/Cargo › Cargo Heating
Issued 18 August 2003 Resolved
Renew Sight (Fire) Glass for thermal fluid heater refractory chamber.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 3 September 2003
Resolution: Sight glass for thermal fluid heater refractory chamber renewed.
Engineering › Lubricating Oil Storage/Transfer System
Issued 18 August 2003 Resolved
Secure Stbd cargo pump shaft guard.
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 18 August 2003
Engineering › Diesel Engine (auxiliary)
Issued 18 August 2003 Resolved
Renew missing cap/port prime mover exhaust.
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 18 August 2003
Deck/Cargo › Cargo Heating › General
Issued 18 June 2002 Resolved
Provide CG approved test procedures for thermal fluid heater and prove proper operation. LEGACY COMPONENT DESC: Test procedures for thermal fluid heater
Condition: Improper/Lack of Maintenance
Due 18 July 2002
Resolved 21 January 2005
Deck/Cargo
Issued 19 May 2000 Resolved
PROVE PROPER OPERATION OF CARGO PUMP ENGINE SHUTDOWN, PRIOR TO DISCHARGING CARGO.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Documentation
Issued 19 May 2000 Resolved
PRIOR TO LOADING PROVIDE A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY (COFR).
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Construction/Loadline
Issued 15 April 1999 Resolved
Present barge, when empty for inspection of sideshell.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Engineering
Issued 15 April 1999 Resolved
Open and examine boiler and provide report on hot spot as discussed with vessel representative..
Condition: Unknown
Due 22 April 1999
Resolved 21 April 1999
Construction/Loadline
Issued 13 June 1996 Resolved
CLEAN GAS FREE ALL WING VOIDS AND MAKE #3 PORT WING VOID AVAILABLE FOR INSPECTION BY COAST GUARD MARINE INSPECTOR._x001C_ _x001C_ NOTE: MATERIAL IN #3 DID NOT APPEAR TO BE #6 OIL (CARGO) _x001C_
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Construction/Loadline
Issued 9 March 1994 Resolved
FIX/RENEW INOP. DOGS ON ALL HATCH COVERS.
Condition: Unknown
Due 9 April 1994
Resolved 11 March 1994
Deck/Cargo
Issued 9 March 1994 Resolved
HYDRO TEST ENTIRE CARGO PIPE SYSTEM ON VESSEL. REPAIRS MADE TO LOADING LINE WHERE IT PENETRATES TANK TOP AFT. GOUGED AND WELDED FRACTURE IN PIPE.V ESSEL PERMITTED TO MAKE ONE LOADED RUN WITH ASPHALT, THEN HYDRO CARGO PIPE. CARGO PIPE UNABLE TO TESTED THIS DATE. TO BE WITNESSED BY CG.
Condition: Unknown
Due 9 March 1994
Resolved 9 March 1994
Construction/Loadline
Issued 9 March 1994 Resolved
MAKE PROPER AND PERMENANT REPAIRS TO FRACTURE STBD BOW CORNER ABOVE RUB PAD. UNKNOWN AT THIS TIME IF FRACTURE IS IN VOID ITSELF.
Condition: Unknown
Due 9 March 1994
Resolved 9 March 1994
Deck/Cargo
Issued 9 March 1994 Resolved
REPAIR/REPLACE DAMAGED/MISSING INSULATION ON HEATED CORGO PIPING.
Condition: Unknown
Due 9 March 1994
Resolved 9 March 1994
Deck/Cargo
Issued 9 March 1994 Resolved
CLEAN /REMOVE OIL AND OILY RAGS/WASTE FROM VESSEL. CAUSED BY LACK OF MAINTENANCE. PRIOR TO VESSEL'S DEPARTURE FROM VICKSBURG.
Condition: Unknown
Due 9 March 1994
Resolved 11 March 1994
Construction/Loadline
Issued 16 February 1993 Resolved
Found water in port aft void and forward starboard void. Unable to locate source of leak due to water levels. Voids are to be pumped and permanent repairs prior to 17 MAR 93.
Condition: Unknown
Due 16 February 1993
Resolved 16 February 1993
Construction/Loadline
Issued 2 April 1991 Resolved
MAINTAIN TEMPORARY REPAIRS TO 4 FOOT FRACTURE AT DECK KNUCKLE IN WAY OF STARBOARD BOW BOX VOID. PERMANENT REPAIRS TO BE COMPLETED NO LATER THAN 17MAY91 TO THE SATISFACTION OF THE COGNIZANT OCMI._x001C_
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Deck/Cargo
Issued 20 March 1989 Resolved
MAKE ALL CARGO VALVE REACH RODS VAPORTIGHT AT THE DECK PENETRATION.
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Deck/Cargo
Issued 20 March 1989 Resolved
REMOVE PRODUCT FROM #3 STBD AND #6 PORT WING VOIDS.
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989

Ownership record