Records from 1998 to 2012. Most recent: inspection, 16 July 2012.
Inspection history · 31
16 July 2012
Ballast Water Examination · Deficiency Check · ISPS II Exam · PII Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4367152
15 July 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4379108
4 February 2010
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3675288
27 January 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3671115
26 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3671808
25 January 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3669399
8 January 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3656274
23 April 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3190540
21 April 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3188652
17 April 2008
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3186363
10 February 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2871447
2 February 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2866087
5 February 2006
Ballast Water Examination · ISPS I Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2579548
14 April 2005
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2334176
18 February 2005
MARPOL Annex I Examination · ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2291516
10 July 2004
ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2126537
14 May 2004
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2067872
23 September 2003
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1911013
18 July 2003
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1847315
26 January 2003
Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1733399
21 July 2002
Ballast Water Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1647061
12 January 2002
Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1476293
15 July 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 291624
4 January 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 285750
9 March 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 275638
24 December 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 435758
7 April 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 502878
6 April 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 462119
5 April 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 427177
2 April 1999
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 427135
1 December 1998
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 423186
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 July 2012
Resolved
1530 - Ships 9 GHZ X-Band radar was not operational Solas(97cons) C.V, R.12(g). 17 a, c. issued.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2012
Resolution: Tech report received. Cleared by [name withheld].
Documentation › Certificates/Documents › IAPP Certificate Supplement
Issued 16 July 2012
Resolved
0199 - The ships refrigeration system is serviced with 404a. The IAPP certificate identifies R22. System was changed under contract while in dry dock in December 2011. Solas(09 cons), C.I, R.11(b). 17a,c issued.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2012
Resolution: IAPP updated to reflect changes.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 16 July 2012
Resolved
0750 - A-boundry fire doors/A-class doors in Galley and Engine Room to Purifier Room did not self close and properly seal. Solas(09 cons), C.I, R.11(a). Issued 17 a,c.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2012
Resolution: Packing renewed. self-closing devices repaired/replaced.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 16 July 2012
Resolved
2035 - Fire Control Plans shall be exhibited and showing clearly the various fire sections enclosed by A-class divisions. Fire Control Plan legend symbols were updated in 2003. The ships Fire Control Plan does not utilize the new symbols for A-60 self-closing doors. Solas(09 cons), C. II, R.15.2.4.1. Issued 17 a,c.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2012
Resolution: Condition of Class issued to update fire plan by 18SEP12.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 27 January 2010
Resolved
The vessel's Propeller Revolution Indicator was reported not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2010
Resolved 28 January 2010
Resolution: The vessel was issued a condition of class for the inoperable Propeller Revolution Indicator to expire on 25 March 2010.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 January 2010
Resolved
Oily water seperator's content meter does not operate at 15 ppm. The content meter shuts down the bilge pump at 0.01 ppm. Ensure proper operation of oil content meter and calibration to satisfaction of attending class surveyor. Vessel must retain all oily water/slops on board.
Due 14 March 2010
Resolved 28 January 2010
Resolution: OWS was surveyed by class and technicians calibrated oil content meter. OWS is fully operational (see attached class report and technician report)
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 21 April 2008
Resolved
Vessel reported echo depth sounding device onboard is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2008
Resolved 25 April 2008
Resolution: Received satisfactoroy tech report attesting to the operation of the vessel''s depth sounder.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 18 February 2005
Resolved
The three fire screen doors leading from galley to the crew's messroom (port side) and the officer's pantry and messroom are rusting out at the bottom of the door and in need of replacement / repair. One door on starboard side leading to the officer's mess room will not fully close due to the rust / swelling. Repair / replace these doors to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 April 2005
Resolution: The fire doors are repaired
Navigation › Collision/Grounding Avoidance
Issued 18 July 2003
Resolved
Vessel has one inoperable RADAR. LEGACY COMPONENT DESC: Radar
Action required: 15 - Rectify deficiencies by next port
Resolved 22 September 2003
Resolution: Recieved Class report by fax.
Navigation › Piloting/Steering
Issued 18 July 2003
Resolved
Vessel has a inoperable Gyro Compass Repeater. LEGACY COMPONENT DESC: Gryo Compass Repeater
Action required: 15 - Rectify deficiencies by next port
Resolved 22 September 2003
Resolution: Recieved Class report by fax.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 26 January 2003
Resolved
Leaks in hydraulic system of cargo hatch lifting gear washed overboard creating sheen in water. Vessel reported sheen and leaks were repaired prior to departure.
Condition: Improper/Lack of Maintenance
Due 26 January 2003
Resolved 26 January 2003
Resolution: Leaks fixed during course of inspection.
Accommodation/Occupational Safety
Issued 24 December 1999
Resolved
PROVIDE NEW CREW FAMILIARZATIONTRAINING IN ACCORDANCE WITH STCW 95 A-VI/1 PRIOR TO NEXT US PORT.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Documentation
Issued 24 December 1999
Resolved
UPDATE OIL TRANSFER PROCEDURE.33 CFR 155.750 PRIOR TO NEXT US PORT
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Electrical
Issued 1 December 1998
Resolved
Provide electrical matting in the control room and also in the emergency generator room in front of the control pannels.
Condition: Unknown
Due 2 April 1999
Resolved 2 April 1999
Navigation
Issued 1 December 1998
Resolved
Provide all day shapes on board as required by 33 CFR 88.05.
Condition: Unknown
Due 2 April 1999
Resolved 2 April 1999
Documentation
Issued 1 December 1998
Resolved
Insure all monthly safety checks are done and logged.
Condition: Unknown
Due 2 April 1999
Resolved 2 April 1999