Records from 2016 to 2026. Most recent: inspection, 26 January 2026.
Inspection history · 20
26 January 2026
Internal Structural Exam · Examination of Repairs · Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8302022
1 July 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8170850
17 July 2024
Type not recorded
No type recorded · USCGC LIBERTY (WPB 1334) · USCG Arctic District (CGD-A) · Activity 7967908
1 May 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7907497
1 April 2024
Administrative Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7888439
24 April 2023
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7674542
25 April 2022
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7438822
31 March 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7423013
29 May 2021
Type not recorded
No type recorded · USCGC CHANDELEUR (WPB 1319) · USCG Arctic District (CGD-A) · Activity 7219816
20 April 2021
DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7178746
5 May 2020
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6952319
14 April 2020
Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6912542
3 June 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6676303
1 May 2018
COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6399332
10 April 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6388890
10 April 2018
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6400242
5 April 2018
Plan Review "T" Boat · Construction Oversight
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6390489
18 July 2017
Type not recorded
No type recorded · USCGC NAUSHON (WPB 1311) · USCG Arctic District (CGD-A) · Activity 6215130
15 May 2017
Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6146663
28 April 2016
Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5869235
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 July 2025
Resolved
Ensure there is a means to test for alcohol.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 9 July 2025
Resolution: strips on board
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 July 2025
Resolved
Audible alarm for bilge high water alarm was not operational. Repair/renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 9 July 2025
Resolution: repaired, tested sat
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 July 2025
Resolved
ER heat sensor is not able to be tested; however, alarm panel was not operational when test button was pressed. Ensure there is an operational heat detector in the ER with an operational alarm panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 9 July 2025
Resolution: renewed, tested sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2023
Resolved
Prove proper operation of the fixed bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2023
Resolution: pumped out laz
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 April 2023
Resolved
Ensure ER bilge high water alarm is visual and audible.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2023
Resolution: tested sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 April 2023
Resolved
Ensure RLB is marked
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2023
Resolved 3 May 2023
Resolution: properly marked
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 April 2023
Resolved
Ensure breaker panel in head has no openings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2023
Resolved 3 May 2023
Resolution: corrected
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 24 April 2023
Resolved
COD is expired, renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2023
Resolution: renewed
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 24 April 2023
Resolved
Vessel is required to conduct drug and alcohol testing with DOT approved test strips.
Action required: 10 - Deficiency Rectified
Resolved 24 April 2023
Resolution: Explained to master requirement to conduct alcohol testing with DOT approved test strips.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2021
Resolved
Replace the handline for the ring buoy. Handline found to be wasted.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 April 2021
Resolution: Replaced with new ringbuoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 April 2021
Resolved
Replace the ringbuoy battery with an approved type.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 April 2021
Resolution: Replaced the battery unit with the type required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2021
Resolved
Post a life jacket placard for each type of approved life jacket onboard.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 April 2021
Resolution: Lifejacket donning placards were posted for both type of lifejackets onboard.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 20 April 2021
Resolved
Compass needs to be permanently affixed at the helm station.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 April 2021
Resolution: Compass has been permanently fastened at the helm station.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 April 2021
Resolved
New EPIRB needs to be registered & properly secured in a float free arrangement.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 April 2021
Resolution: EPIRB is properly registered and is mounted in a float free configuration.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 20 April 2021
Resolved
Vessel operator to show proof of having a valid marine radio operator permit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 April 2021
Resolution: Master showed proof of having a valid FCC marine radio operator permit.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 April 2021
Resolved
Replace expired medicines in first aid kit.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 April 2021
Resolution: All medicines with expiration dates are now current.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 April 2021
Resolved
Install metal clamps no less than 24" apart for cable run in forward cabin space.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 April 2021
Resolution: Metal clamps have been installed no more than 24" apart in the forward cabin space.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 April 2021
Resolved
Remove or properly secure dead end wire found in forward cabin space.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 April 2021
Resolution: Dead end wire has been removed from service.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 20 April 2021
Resolved
Properly secure or remove handle to sewage overboard valve when inside of 3NM.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 April 2021
Resolution: Sewage valve is shown to be secured within 3NM.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2021
Resolved
Provide 03 buckets to serve as fire buckets. Must meet the requirement for fire bucket.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 26 April 2021
Resolution: 03 fire buckets (2.5 gal) stenciled with line attached are onboard.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 June 2019
Resolved
Engine room bilge high level alarm is not operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2019
Resolved 12 June 2019
Resolution: New alarm panel installed on the bridge and tested satisfactory.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 June 2019
Resolved
Provide required contents for first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 12 June 2019
Resolution: New first aid kit provided with all required contents.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 3 June 2019
Resolved
Update garbage discharge placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 12 June 2019
Resolution: New placard posted.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 May 2016
Resolved
Vessel does not have a FCC Safety Certificate. Need to have FCC tech issue Safety Certificate.
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 6 May 2016
Resolution: FCC safety certificate has been issued.
Lifesaving › Hand Flares › Expired
Issued 4 May 2016
Resolved
Smoke hand flares were expired. Need to replace 6 smoke hand flares prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 May 2016
Resolved 6 May 2016
Resolution: Correct amount of flares was purchased and placed onboard.