← All vessels
ROYAL POLARIS
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named ROYAL POLARIS
ROYAL POLARIS is a 1975 passenger vessel (inspected). The Coast Guard has recorded 127 inspections since 1985, most recently in June 2025, along with 189 deficiencies, 1 operational control and 5 casualty investigations between 2006 and 2019.
Records from 1985 to 2025. Most recent: inspection, 3 June 2025.
- Built
- 1975
- Last inspected
- 3 June 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 127
- Deficiencies
- 189 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 5 investigations · 2006–2019
Identity
566157
WYM7156
48407
Flag
UNITED STATES
367050490
Maury page id
psix-48407
Inspections, by type
…with no type recorded20
Years with a record
37 calendar years (1985–2025)
The 127 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)103.7 ft × 28.0 ft × 6.7 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFLOYD L CHAFFEE · CHULA VISTA, CA, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WYM7156MMSI 367050490 · active · compulsorily equipped · granted 8 April 2025, expires 21 June 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 127
3 June 2025
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8104248
12 May 2025
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8133485
27 August 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7990516
29 May 2024
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7923137
24 April 2024
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7901069
13 June 2023
MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7704494
13 June 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7786408
3 May 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7680624
17 April 2023
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7670407
18 January 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7623147
16 November 2022
Excursion Permit · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7595800
31 October 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7587094
23 May 2022
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7457687
2 May 2022
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7442697
23 March 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7504141
1 November 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7343324
25 May 2021
COI Inspection · DAPI Audit · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7205840
29 April 2021
Hull Examination · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7185538
9 February 2021
Excursion Permit · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7158189
26 May 2020
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6960705
1 May 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6949455
7 February 2020
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6907955
2 October 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6826259
26 July 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6762710
26 July 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6766678
6 June 2019
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6692655
15 May 2019
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6684736
21 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6545776
20 July 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6487946
4 June 2018
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6422762
14 May 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6414501
12 June 2017
Administrative Inspection · MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6166290
11 May 2017
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6143793
6 June 2016
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5899272
13 May 2016
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5876216
12 May 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5875214
16 June 2014
COI Inspection · DAPI Audit · Security Plan Review - VSP · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4886398
27 May 2014
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4862771
7 June 2012
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4318282
7 December 2009
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3646052
13 May 2009
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3579913
30 May 2008
In-Service Inspection · COI Inspection · Deficiency Check · Construction Oversight · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3163859
13 May 2008
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3163871
24 March 2008
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3170618
24 September 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3065490
17 May 2007
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2904654
15 May 2007
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2904597
6 April 2007
Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2905394
20 October 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2804724
4 October 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2793441
11 August 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2744168
5 August 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2744072
5 June 2006
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2671318
18 May 2006
Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2590681
15 May 2006
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2590641
8 February 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2581668
26 May 2005
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2308506
4 May 2005
Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2351189
7 April 2005
Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2328820
17 February 2005
Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2295516
13 July 2004
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2132165
14 June 2004
MTSA/ISPS Verification · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2053786
24 May 2004
Hull Examination · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2025100
20 May 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2072959
2 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979746
11 June 2003
Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1815198
28 May 2003
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1804231
25 November 2002
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1710455
21 October 2002
Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1693472
28 May 2002
Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1620173
10 April 2002
Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1603344
5 April 2002
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1601631
1 April 2002
Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1495619
6 March 2002
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1495672
25 December 2001
In-Service Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1473725
7 June 2001
COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1403396
30 May 2001
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1066604
14 May 2001
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1063519
4 October 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1054905
9 June 2000
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1384474
9 June 2000
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1403250
18 May 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 55018
28 December 1999
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 812864
17 June 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 878281
8 June 1999
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1399128
3 June 1999
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1429164
4 February 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 176053
29 June 1998
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1459432
18 June 1998
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1421526
11 August 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 215183
24 June 1997
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1364248
29 April 1997
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1091273
2 July 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 93149
24 June 1996
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1445100
5 June 1996
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1385747
5 July 1995
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1371131
27 June 1995
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 163120
1 December 1994
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1179150
5 July 1994
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1428360
23 June 1994
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1405566
29 September 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 844480
7 July 1993
COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 844745
1 July 1992
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1259494
19 June 1992
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 960183
25 April 1992
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1357931
24 June 1991
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 909097
14 June 1991
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1339268
4 June 1991
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 929888
2 May 1991
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1229401
21 June 1990
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1227890
8 June 1990
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1215823
2 May 1990
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 914071
13 September 1989
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1339951
27 June 1989
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1343411
26 April 1989
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1042707
17 January 1989
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 891503
6 January 1989
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1352992
17 June 1988
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 891924
15 June 1988
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 890150
23 May 1988
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1044892
9 November 1987
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1330130
5 June 1987
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1030341
19 May 1987
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1332875
12 June 1986
Deficiency Check · Credit Drydock · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 989861
28 October 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 996379
21 June 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 985964
13 June 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1286306
Deficiency record · 189
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2024
Resolved
The emergency fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. MI found the emergency fuel-cut off valve did not fully close from the pull station outside the space. Fix the valve so it fully closes and notify the local OCMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 May 2024
Resolved
Strainers must be leak free. MI found several of the RACOR filter fuel flame bowls with fuel in them. Remove the fuel to prove the bowls are not leaking and notify local OCMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. MI found a leaky fuel hose on the # 1 MDE. Owner had spare on board and it was replace and tested, ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI found exposed gears on MDE's, Replace and notify local OCMI.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 April 2024
Resolved
-Concentrated pitting found IWO engine room between longitudinal frames 2-3 stbd from aft bulkhead to sea chest. Clean area and provide gauging report or repair proposal.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 April 2024
Resolved
-Concentrated pitting found IWO engine room port side bottom shell between frames 2-4 aft bulkhead to generator. Clean area and provide gauging report or repair proposal
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 April 2024
Resolved
-Concentrated pitting found IWO engine room port side shell aft bulkhead to 1st frame. Provide gauging report or repair proposal.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 April 2024
Resolved
-Concentrated pitting fond IWO engine room port fwd bottom plate from fwd bulkhead aft 1 frame between frames 5-6. Provide gauging report or repair proposal.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 April 2024
Resolved
-Concentrated pitting found IWO engine room port side shell from fwd bulkhead aft 1 frame. Provide gauging report or repair proposal.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 June 2023
Resolved
Vessel's Certificate of Documentation is expired. Provide a valid Certificate of Documentation for the vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 April 2023
Resolved
Small passenger vessels that have overnight accommodations for passengers must comply with the requirements in 46 CFR 177.500; construction/arrangement and means of escape.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 June 2022
Resolved
A vessel must carry one floating water light. Water light failed its operational test due to being cracked and waterlogged; Repair / replace w/ CG approved floating electric water light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2022
Resolved
Main propulsion engine and generator dual F/O filter unit bowl left filled with fuel. Remove fuel.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 June 2022
Resolved
Structural Fire Protection insulation missing from engine room overhead. Re-install missing insulation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2022
Resolved
Engine room stbd oil centrifuge pump motor missing j-box cover. Install cover.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2022
Resolved
SWBD panel generator cabling outer jacket deteriorated. Make repairs to re-insulate outer jacket of cable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2022
Resolved
SWBD panel bottom cable penetration not properly sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 June 2022
Resolved
Fire pump discharge gauge indicator faulty. Repair / replace gauge unit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2022
Resolved
Main deck salon STBD HVAC pump unit electrical power cord plug missing ground prong. Repair power cord with approved marine boat cable and grounded plug.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 6 June 2022
Resolved
Top deck max passenger count placard missing. Install placard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2022
Resolved
To deck port side freezer unit power cable spliced with electrical extension cord. Replace with appoved marine boat cable.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 June 2022
Resolved
Aft passenger accommodation portable fire extinguisher
service tag expired May 2022. Re- service extinguisher.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2020
Resolved
Must replace 01 lifebuoy due to deterioration to satisfaction of the CG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 May 2020
Resolved
Must provide spanner wrench at fire station to the satisfaction of the CG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 26 May 2020
Resolved
Must secure all deck plating in engine space to prevent slips, trips and falls.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 26 May 2020
Resolved
Must have radios and serviced by certified FCC radio technician.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
Sector San Diego does not have vessel's electrical plans on file. Provide an up-to-date one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
Electrical equipment must be installed and maintained to protect passengers, crew and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Correct the following: (1) Remove or properly terminate (in j-box) dead-end wires found in galley (2) Properly splice wiring w/ twist wire nuts in galley storage and at A/C unit in cabin (3) Install spare cover on opening in distribution panel at aft door.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 October 2019
Resolved
Install smoke detector at galley and in crew cabins.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2019
Resolved
Provide additional ladder rungs above main deck on at both emergency escapes.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 2 October 2019
Resolved
Provide and log training to all crew regarding use of Engine Room CO2 pull station and ventilation closures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2019
Resolved
Repair/replace the 04 adult lifejackets found out of service. Adult total person count reduced to 43 until corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 June 2019
Resolved
Repair the audible bilge alarm.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2019
Resolved
Replace expired items in first aid kit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 June 2019
Resolved
Perform and log safety drills and EPIRB test as required by 46 CFR 185.728, .520, and .524. Complete by next inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019
Resolved
Properly secure electrical cable serving anchor windless every 14 inches.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 June 2019
Resolved
Address water leak from transducer in second compartment.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 September 2018
Resolved
IMO: Vsl is broadcasting no IMO #, CLSN: Vsl is broadcasting Invalid Call Sign
Communications › Radio Communications › EPIRB
Issued 4 June 2018
Resolved
Provide serviceable EPIRB
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 4 June 2018
Resolved
Provide current medical cards (STCW) prior to international voyage
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 June 2018
Resolved
Provide valid first aid kit
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 June 2018
Resolved
Provide retro reflective tape on ring buoys
Fire Fighting › Means of Escape › Escape Route Signs
Issued 4 June 2018
Resolved
Provide emergency escape sign aft escape hatch main deck
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 4 June 2018
Resolved
Properly store hazardous materials found in E/R
Construction/Loadline › Penetrations › Gasket
Issued 4 June 2018
Resolved
Prove rudder post leak free
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 4 June 2018
Resolved
Provide proper piping for purifier drains
Navigation › Collision/Grounding Avoidance › Transponder
Issued 12 June 2017
Resolved
Provide 02 sarts.
Engineering › Steering Gear System › Linkage
Issued 12 June 2017
Resolved
Provide cotter pin in steering system.
Fire Fighting › Fire Main › Pressure
Issued 12 June 2017
Resolved
Provide operational fire pump guage.
Electrical › Electric Supply System (service) › Cable
Issued 12 June 2017
Resolved
Make electrical cables and wires have support every 24 inches.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 June 2017
Resolved
Provide working bilge alarm.
Engineering › Fuel Oil Service System › Valve, Control
Issued 10 June 2016
Resolved
Label emergency fuel cutout valve
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 June 2016
Resolved
Provide 5 additional type 1 adult sized life jackets/ vessel is restricted to 45 total persons.
Documentation › Markings/Placards › Official Number (US)
Issued 10 June 2016
Resolved
Properly label vessel's official number on the structural part of the vessel.
Fire Fighting › Fire Pumps › Pumpshaft
Issued 10 June 2016
Resolved
Properly secure guard for fire pump motor.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 6 June 2016
Resolved
Renew CO2 pressure activated switch for generator shutdown and prove proper operation.
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 June 2014
Resolved
Prove proper operation of remote fuel shut off valve. Prior to sailing.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 June 2014
Resolved
Repair Starboard green navingational light.
Engineering › Steering Gear System › Linkage
Issued 16 June 2014
Resolved
Install missing cotter pins (4) on lazzerate steering gear bolts.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 June 2014
Resolved
Provide cover for E/R electrcial junction box.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 June 2014
Resolved
Provide cover on missing light fixture port side engine room.
Communications › Radio Communications › EPIRB
Issued 7 June 2012
Resolved
Provide and prove proper operation of epirb.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 7 June 2012
Resolved
Provide escape route signs for both bunk room escape hatches.
Stability › Weathertight Integrity › General
Issued 7 June 2012
Resolved
Replace missing window in head.
Lifesaving › Lifebuoys › Stowage
Issued 7 June 2012
Resolved
Provide detachable clip for lifering water light.
Navigation › Piloting/Steering › Marine Charts
Issued 7 June 2012
Resolved
Provide updated chart for operating area.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 7 June 2012
Resolved
Provide new fire extingusher for the one B-II that needs recharging by the guage.
Fire Fighting › Combustible Materials › Insulation
Issued 2 June 2008
Resolved
Provide lagging where identified on new MDEs.
Engineering › Generator (propulsion-electric) › Feeder Circuitry
Issued 2 June 2008
Resolved
Prove proper operation of port generator.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 June 2008
Resolved
Prove proper operation of shutdowns for MDEs, blowers, and generators during operation of fixed CO2 F/F system.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 June 2008
Resolved
Provide double hose clamps throughout E/R, where identified.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 June 2008
Resolved
Perform general housekeeping of entire vessel and make ready to carry passengers.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 2 June 2008
Resolved
Ensure fixed CO2 F/F system controls (pressure switches) are located outside space protected (E/R).
Electrical › Electric Generation Source (service) › Generator Cable
Issued 2 June 2008
Resolved
Provide chafing protection for generator cables, as identified.
Engineering › Fuel Oil Service System › Hose
Issued 2 June 2008
Resolved
Provide chafing protection and brackets for all new fuel lines.
Engineering › Fuel Oil Service System › Pump
Issued 2 June 2008
Resolved
Permanently mount/secure auxiliary fuel pump.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 June 2008
Resolved
Provide protective covers for all E/R lights.
Engineering › Fuel Oil Service System › Hose
Issued 2 June 2008
Resolved
Replace fuel hoses to/from aft tank (provide hoses that meet SAE J-1942).
Electrical › Electric Generation Source (service) › Generator
Issued 2 June 2008
Resolved
Provide data plate for stbd generator.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 May 2008
Resolved
Prove proper operation of audible and visual bilge high-water alarms.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 30 May 2008
Resolved
Provide required gauges at operating station for main engines RPM, oil pressure, and jacket water discharge temperature.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 30 May 2008
Resolved
Conduct check-ride with new engines and new generators in presence of CG inspector.
Communications › Radio Communications › Satellite Communications Capability
Issued 30 May 2008
Resolved
Prove proper operation of NAVTEX receiver.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 May 2008
Resolved
Conduct annual servicing of fixed CO2 F/F system in E/R.
Communications › Audible Communications › Horn/Whistle
Issued 30 May 2008
Resolved
Repair ship's horn.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 May 2008
Resolved
Replace cracked lens for anchor light.
Lifesaving › Inflatable Liferafts › Container Construction
Issued 30 May 2008
Resolved
Properly install or reconfigure cradle to accommodate new liferaft.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 May 2008
Resolved
Repair/replace light cover and electrical switch cover in crew storage closet (A/C room).
Electrical › Electrical Distribution System (service) › Panelboard
Issued 30 May 2008
Resolved
Repair/replace panel in ice maker room.
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 May 2008
Resolved
Prove proper operation off all remote fuel shut-off valves (3).
Electrical › Electric Generation Source (service) › Generator
Issued 28 May 2008
Resolved
Provide drawings and cut sheet for AC and DC electrical systems, including cables/wiring, breakers, and manufacturer's recommended starter cable specs.
Engineering › Fuel Oil Service System › Hose
Issued 28 May 2008
Resolved
Ensure all fuel lines and fittings meet SAE J-1942, and provide brackets and chafing protection throughout the system.
Stability › Intact Righting Energy › General
Issued 28 May 2008
Resolved
Provide weight difference data from last haul out, and vessel's light ship displacement.
Stability › Watertight Integrity › General
Issued 28 May 2008
Resolved
Make watertight all bulkhead penetrations in E/R.
Engineering › Fuel Oil Service System › Tank
Issued 28 May 2008
Resolved
Provide static protection for day fuel tank, and install vent line and remote fuel shut-off valve.
Engineering › Bilge Water Management System › Pump
Issued 28 May 2008
Resolved
Re-install pulley-driven bilge pump.
Construction/Loadline › Hull › Bracket
Issued 28 May 2008
Resolved
Re-weld overhead bracket as identified.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 May 2008
Resolved
Install lagging for exhaust piping.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 15 May 2007
Resolved
Six (6) adult PFDs rejected; replace w/new PFDs.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 15 May 2007
Resolved
Upon completion of servicing, install liferafts (2).
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 15 May 2007
Resolved
Repair/replace leaking exhaust line on the stbd MDE.
Fire Fighting › Fire Hoses › Condition
Issued 15 May 2007
Resolved
Replace leaking fire hose (portside).
Fire Fighting › Ventilation Systems › Stairway Enclosure Ventilation
Issued 15 May 2007
Resolved
Prove proper operation of (all) ventilation shut-downs (closures) to the engine-room space.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 May 2007
Resolved
Replace missing guard on overhead light fixture (stbdside) in the engine-room.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 May 2007
Resolved
Repair/make operable lazarette bilge alarm.
Engineering › Steering Gear System › Ram
Issued 15 May 2007
Resolved
Replace missing cotter-pin on the stbd steering ram and clean (rust).
Navigation › Piloting/Steering › Magnetic Compass
Issued 15 May 2007
Resolved
Repair in-operable light on magnetic steering compass.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 15 May 2007
Resolved
Install SSB w/DSC capability per FCC requirement for voyages that extend beyond 100 NM fm shore.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 May 2007
Resolved
Update first aid kit per CG guidelines and discard all expired items.
Communications › Audible Communications › Bell
Issued 15 May 2007
Resolved
Re-install ship's bell (missing).
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 May 2006
Resolved
Crop & renew approximately ten (10) inches of the #3 longitudinal frame, portside engineroom bulkhead, with dime-sized corrosion hole & severe pitting. Sandblast frames on both sides that also have pitting and have electrician conduct testing to determine if stray electrical current exists in that area from bait tank pump.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 May 2006
Resolved
Remove water fm fwd bunkroom & forepeak bilges.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 May 2006
Resolved
Rejected twenty (20) adult & one (1) child PFD. Vsl is limited to NMT twenty-eight (28) total persons until new PFDs acquired.
Lifesaving › Inflatable Liferafts › Servicing
Issued 15 May 2006
Resolved
Vsl's two (2) liferafts (25 pers/each) have been removed for servicing. Vsl is prohibited fm carrying pax until re-installed o/b.
Lifesaving › Hand Flares › Quantity
Issued 15 May 2006
Resolved
Six (6) additional parachute flares needed. Vsl is restricted fm int'l voyages until additional flares acquired.
Navigation › Piloting/Steering › Marine Charts
Issued 15 May 2006
Resolved
Navigational chart/s & pubs (coast pilot, light list) need to be updated or replaced with new (up-to-date) versions.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 May 2006
Resolved
The vsl's 360* white mast-head light is inoperable. Repair/replace bulb.
Electrical › Lighting (emergency) › Outlet Box
Issued 15 May 2006
Resolved
Replace fuse housing for emergency lights electrical panel damaged when owner accidentally broke it.
Fire Fighting › Grease Extraction Hood › General
Issued 15 May 2006
Resolved
Thoroughly clean galley hood, vents, grill and surrounding cooking surfaces.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 26 May 2005
Resolved
Replace two worn lifejackets.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 May 2005
Resolved
Replace retro-tape on four lifejackets as noted and replace/re-label lifejacket with "shogun" markings.
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 26 May 2005
Resolved
Ensure SART battery is replaced by the end of May.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 26 May 2005
Resolved
Label emergency escape hatches in accommodation spaces.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 May 2005
Resolved
Repair/replace water light on port side lifebuoy.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 May 2005
Resolved
Secure wiring on bait pump and salt water pressure pump.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 26 May 2005
Resolved
Label draft marks on hull. Complete at dry-dock.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 26 May 2005
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation › Piloting/Steering › Marine Charts
Issued 26 May 2005
Resolved
Provide "current" charts for areas transited.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 May 2005
Resolved
Provide "current" Coast Pilot and Light List for areas transited.
Communications › Internal Communications System › Sound-powered Telephone
Issued 26 May 2005
Resolved
Repair P.A. system mic on the bridge/control station.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 26 May 2005
Resolved
Repair/replace fire ext. in galley.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 26 May 2005
Resolved
Prove proper operation of emergency lighting/system during dead ship.
Engineering › Fuel Oil Service System › Filter
Issued 26 May 2005
Resolved
Provide shield for stbd generator fuel filter.
Engineering › Fuel Oil Service System › Valve, Control
Issued 26 May 2005
Resolved
Repair aft fuel shut off.
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 May 2005
Resolved
Repair leaks on stbd M/E cooling line.
Communications › Radio Communications › EPIRB
Issued 14 June 2004
Resolved
Register EPIRB with NOAA.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 June 2004
Resolved
Repair lagging in Engine room.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 14 June 2004
Resolved
Blank all unused penitration in engine room gauge panels.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2004
Resolved
Remove deadended wires or properly terminate.
Engineering › Steering Gear System › Rudder
Issued 24 May 2004
Resolved
Temporary rudder repair, to the stbd rudder, with maxtech-epoxy-was approved for one year by CID. Epoxy is not normally acceptable for aluminum repairs. Proposal for permanent repairs-welding/renewal-must be submitted to and approved by CG. Wastage was on side shell towards leading edge of rudder. LEGACY COMPONENT DESC: Rudder
Lifesaving › Buoyant Apparatus
Issued 28 May 2003
Resolved
Provide adequate lifesaving. IBA's were missing due to servicing.
Personnel › Training
Issued 28 May 2003
Resolved
Perform satisfactory manoverboard and fire drills.
Engineering › Bilge Water Management System
Issued 28 May 2002
Resolved
Make engine room bilge alarm operable. LEGACY COMPONENT DESC: Alarm
Navigation › Collision/Grounding Avoidance
Issued 28 May 2002
Resolved
Make compass light operable. LEGACY COMPONENT DESC: Compass
Lifesaving › Lifebuoys
Issued 28 May 2002
Resolved
Install retro tape on ring buoys. LEGACY COMPONENT DESC: Retro tape
Fire Fighting › Fire Hoses
Issued 28 May 2002
Resolved
Replace fire hose from starb. station. LEGACY COMPONENT DESC: Condition
Engineering › Fuel Oil Service System
Issued 28 May 2002
Resolved
Make after most emergy fuel stop operable. Lube all U-Joints on reach rods. LEGACY COMPONENT DESC: Valve
Electrical › Electric Generation Source (service)
Issued 28 May 2002
Resolved
Install blanks on power panels in engine room. LEGACY COMPONENT DESC: Panelboard
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 28 May 2002
Resolved
Repair salt water leak on port exhaust pipe. LEGACY COMPONENT DESC: Piping (exhaust)
Electrical › Lighting (service)
Issued 28 May 2002
Resolved
Install globe on light fixture in laz. LEGACY COMPONENT DESC: Lighting Fixture
Construction/Loadline
Issued 7 June 2001
Resolved
Provide metallic penetrations (with metallic shut-off valves) for PVC piping traversing through watertight bulkheads.
Lifesaving
Issued 7 June 2001
Resolved
Provide Damage Control Kit consisting of varies wood plugs, okum and a hammer in a labeled container marked ("DAMAGE CONTROL KIT") and stow above main deck.
Navigation
Issued 4 October 2000
Resolved
Need NAV rules, Tide Table, Light List and Pilot book on board.
Lifesaving
Issued 4 October 2000
Resolved
EPIRB release nedds to be up dated.
Lifesaving
Issued 4 October 2000
Resolved
Separate Child PFDs from Adult PFDs
Lifesaving
Issued 4 October 2000
Resolved
Ned PFD Placard instructions posted near PFD stowage aft of bridge.
Navigation
Issued 4 October 2000
Resolved
Keep up-to-date charts for navigation.
Engineering
Issued 8 June 1999
Resolved
INSTALL FUEL BOWL GUARDS.
Fire Fighting
Issued 8 June 1999
Resolved
REMOVE DEEPFAT FRYER OR INSTALL FIXED FIREFIGHTING SYSTEM FOR DEEPFAT FRYER.
Navigation
Issued 8 June 1999
Resolved
REPAIR STARBOARD STEERING RAM MOUNT.
Fire Fighting
Issued 29 June 1998
Resolved
Install automatic actuation for fixed fire fighting system in engine room. Also, install time delay and siren for system as well as pneumatic switch (or similar) shutdowns for engines taking air from protected space. Submit plans for alteration to USCG for approval prior to completing work.
Construction/Loadline
Issued 18 June 1998
Resolved
Make watertight WTDBHD through hull piping in way of freshwater tank compartment portside.
Construction/Loadline
Issued 18 June 1998
Resolved
make watertight unused overboard discharge piping in way of port side shellplating over 6" above the waterline freshwater tank compartment.
Construction/Loadline
Issued 18 June 1998
Resolved
Gouged and reweld approximately 2" cracked weld in way of portside deck beam forepeak compartment.
Construction/Loadline
Issued 18 June 1998
Resolved
Crop out to the good metal and renew as original shell plating in way of holed starboard bottom keel aft of starboard integral fresh water tank.
Lifesaving
Issued 24 June 1997
Resolved
PROPERLY SERVICE AND INSTALL INFLATABLE LIFEFLOATS TO THE SATISFACTION OF CG MARINE INSPECTOR.
Construction/Loadline
Issued 24 June 1997
Resolved
CROP OUT TO GOOD METAL AND RENEW IN KIND AS ORIGINAL SHARP INDENTATION IN WAY OF PORT TRANSOM JUST ABOVE THE EXHAUST PIPING THROUGH HULL PENETRATION.
Fire Fighting
Issued 29 April 1997
Resolved
Install and demonstrate proper operation of fixed fire extinguishing systemincluding fire detection system, closures of ventilation, generator and main propulsion shutdown if air intake for engines are supplied from the engine room compartment. _x001C_
Fire Fighting
Issued 24 June 1996
Resolved
Relocate Fixed CO2 bottles outside the engine room, or properly install automatic release mechanism, time delay, siren and blower shutdown for fixed CO2 system.
Fire Fighting
Issued 5 July 1995
Resolved
Renew one (50') fire hose due to severe wear and tear.
Documentation
Issued 5 July 1995
Resolved
Required to provide proof that vessel can safely carry upto 40 passengers on the bridge deck. (i. e. statement that vessel can safely carry passengers on the bridge deck and remain stable.)
Construction/Loadline
Issued 4 June 1991
Resolved
REPAIR CRACKED WELD APPROXIMATELY THREE (3) INCHES LONG IN WAY OF THE _x001C_ FORWARD TRANSVERSE FRAME IN THE FORWARD COLLISION COMPARTMENT. _x001C_ _x001C_ _x001C_
Unknown
Issued 8 June 1990
Resolved
CLEAN STEERING COMPARTMENT FREE OF FUEL OIL RESIDUE AND SOOT FROM THE LEAKING EXHAUST TAIL PIPES.
Navigation
Issued 8 June 1990
Resolved
REPLACE LEAKING & CORRODED HYDRAULIC HOSES FOR THE STEERING GEAR SYSTEM IN THE STEERING COMPARTMENT WITH A COAST GUARD APPROVED HYDRAULIC HOSES.
Construction/Loadline
Issued 8 June 1990
Resolved
REPLACE FLEXIBLE RUBBER HOSE FITTINGS CONNECTING OVERBOARD DISCHARGE VALVES TO THE THROUGH HULL FITTINGS IN THE ENGINEEROOM & OTHER PARTS OF THEVESSEL WITH METAL PIPE FITTINGS EQUIVALENT TO THE MATERIAL OF THE THROUGH HULL FITTINGS EXCEPT CAST IRON.
Construction/Loadline
Issued 8 June 1990
Resolved
INSTALL A SHUT OFF VALVE IMMEDIATELY AFT OR FORWARD OF THE COLLISION BULK- HEAD FOR THE BILGE PICK-UP PIPING LINE PENETRATING THROUGH THE COLLISION BULKHEAD. A REMOTE REACH ROAD TO OPERATE THE VALVE ON THE MAIN DECK SHALL ALSO BE INSTALLED TO FACILITATE EASY OPERATION OF THE SHUT-OFF VALVE.
Engineering
Issued 8 June 1990
Resolved
REPLACE CORRODED AND LEAKING PORT AND STARBOARD MAIN DIESEL ENGINES EXHAUSTTAIL PIPES IN THE STEERING COMPARTMENT.
Documentation
Issued 27 June 1989
Resolved
PROVIDE WEIGHT CHANGE INFORMATION FROM THE CHANGE OUT OF THE PROPUSION ENGINES.
Construction/Loadline
Issued 26 April 1989
Resolved
SEPARATE STOWAGE OF CHILD LIFE JACKETS FROM ADULT LIFE JACKETS.
Documentation
Issued 26 April 1989
Resolved
POST ALL SOLAS CERTIFICATES ON BOARD.
Fire Fighting
Issued 26 April 1989
Resolved
REPAIR BRACKET TO FIXED CO2 PIPING SYSTEM.
Fire Fighting
Issued 26 April 1989
Resolved
REPAIR BROKEN GAUGE FOR THE FIRE PUMP.
Navigation
Issued 26 April 1989
Resolved
REPLACE BATTERY ON THE EPIRB.
Lifesaving
Issued 26 April 1989
Resolved
PROVIDE TWO RING BUOY EACH EQUIPPED WITH LIGHT.
Lifesaving
Issued 15 June 1988
Resolved
COMPLETE MARKING AND LABELING OF EMERGENCY ESCAPES, FUEL OIL SHUT OFFS,ETC.
Lifesaving
Issued 15 June 1988
Resolved
PROVIDE TWO LIFE RINGS.
Fire Fighting
Issued 15 June 1988
Resolved
SERVICE ALL PORTABLE AND FIXED FIRE FIGHTING EQUIPMENT.
Documentation
Issued 15 June 1988
Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION ON BOARD THE VESSEL.
Navigation
Issued 15 June 1988
Resolved
PROVIDE CURRENT LIGHT LIST AND COLREGS.
Casualty record · 5
5 August 2006Routine · role: Involved in a Marine Casualty · 1 injured · activity 2744072
11 August 2006Routine · role: Involved in a Marine Casualty · 1 dead · activity 2744168
24 September 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 3065490
12 May 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5875214
26 July 2019Routine · role: Involved in a Marine Casualty · activity 6766678
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.