← All vessels
SNOOPY V
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Oceania District (CGD-O) · Other hulls named SNOOPY V
SNOOPY V is a 1998 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 1998, most recently in March 2026, along with 119 deficiencies, 1 operational control and 3 casualty investigations between 2014 and 2019.
Records from 1998 to 2026. Most recent: inspection, 13 March 2026.
- Built
- 1998
- Last inspected
- 13 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 119 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2014–2019
Identity
1073110
WDE6687
484097
Flag
UNITED STATES
367383390, 368492820
Maury page id
psix-484097
Inspections, by type
…with no type recorded5
Years with a record
25 calendar years (1998–2026)
The 49 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)39.0 ft × 11.5 ft × 6.0 ft
Registered tonnagegross 18 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFORCE MARINE INC · HILO, HI, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKANEOHE, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDR3856MMSI 368492820 · active · voluntarily equipped · granted 18 August 2026, expires 18 August 2036
WDE6687MMSI 367383390 · active · compulsorily equipped · granted 9 November 2018, expires 5 November 2028
WDD2715MMSI 367118870 · expired · compulsorily equipped · granted 2 June 2006, cancelled 6 August 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCB8360MMSI not assigned · expired · compulsorily equipped · granted 27 October 1998, cancelled 27 December 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 49
13 March 2026
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8325883
17 November 2025
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8261141
20 August 2025
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8214671
19 November 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8037733
23 April 2024
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7900459
6 February 2024
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7847422
15 November 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7794151
25 October 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7559253
9 March 2022
In-Service Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7408243
24 February 2022
Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7401761
21 October 2021
Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7336754
20 August 2021
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7285159
19 November 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7098224
24 August 2020
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7021426
19 May 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6956261
11 December 2019
Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6871534
4 November 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6850288
25 July 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6766914
2 June 2019
Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 6701743
2 June 2019
Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 6701745
5 December 2018
Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6592598
9 May 2018
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6408615
6 December 2017
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6321178
8 February 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6084836
14 September 2016
COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6002047
26 July 2016
Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5954005
10 May 2016
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5873952
4 November 2015
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5784671
7 May 2014
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4874769
18 May 2012
Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4315064
6 September 2011
DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4137631
17 November 2010
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3893319
1 December 2009
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3642092
6 November 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3358094
21 July 2008
Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3261120
26 November 2007
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3104591
8 September 2006
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2733314
7 July 2006
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2739496
11 January 2002
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1477996
2 October 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1073788
26 September 2001
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1429626
19 April 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1061678
2 April 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1060401
2 April 2001
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1060404
29 March 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1061884
31 October 2000
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1384625
17 November 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 810285
7 October 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369373
8 October 1998
Hull Examination · Plan Review "T" Boat · Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1438771
Deficiency record · 119
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 November 2025
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Five battery terminals (four on port and one on starboard engine batteries) were found with wing nuts installed to secure connections. Install permanent type connectors to the satisfaction of the attending marine inspector.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 17 November 2025
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. On board alcohol testing kits were expired. Replace kits to the satisfaction of the attending marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 November 2025
Resolved
A vessel must carry a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10). Vessel did not have 48 doses of analgesic medication on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 November 2024
Resolved
A vessel must carry one floating water-light. Floating water light was inoperable.
705- Day light operations only
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 November 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Engine room ventilation was unable to be closed off.
46 CFR 182.465(h)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 November 2024
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Fire extinguishers are not installed in designated locations.
46 CFR 181.520
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 November 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Fire buckets were not on board.
46 CFR 181.610
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 November 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. The indicating panel light was inoperable and the panel was not labeled.
46 CFR 182.530(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 November 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) ... provided that:(1) The pump is listed by an independent laboratory as meeting the requirements in UL 1113. Installed bilge pumps were not UL rated.
46 CFR 182.520(e)(1)
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 March 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must be capable of manual actuation from outside the space. The manual pull cable for the pre-engineered system has a significant spot of rust and wear affecting its serviceability. Replace cable to the satisfaction of the attending Marine Inspector. 46 CFR 181.420(a)(2)
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 November 2023
Resolved
Shutoff valves, installed to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Remote fuel shut off cable snapped. Repair or replace vessel’s means of fuel shutoffs for both engines.
46 CFR 182.455(b)(4)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 November 2023
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Strainers in engine compartment are missing bottom plugs. Install plugs onto the bottom of each strainer.
46 CFR 182.455(b)(6)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 November 2023
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Sixteen adult and two child sized life jackets had deteriorated retroreflective material. Renew retroreflective material to the satisfaction of MI.
46 CFR 185.604
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 October 2022
Resolved
Each watertight compartment must be permanently fitted with a means to dewater that space. The provided independent, electric, submersible bilge pump in the engine room was not capable of dewatering the space due to excessive debris in the bilge. Remove the debris and prove proper operation of the bilge pump.
46 CFR 176.830
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 October 2022
Resolved
Normally unmanned spaces with through-hull fittings or non-watertight closures must be fitted with a bilge high level alarm that activates an audible and visual alarm at the operating station. The lazarette and the forward crew compartment bilge high level alarms were not operational. One additional crew member, in addition to those already required on the COI, shall be required when passengers have access to the vessel to conduct rounds of the lazarette and forward crew compartment bilges. Rounds shall be conducted every 15 minutes when the vessel is away from the dock. Prove proper operation of the bilge high level alarms in those spaces.
46 CFR 182.530
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 October 2022
Resolved
Vessel not required to have a power driven fire pump must have at least 3 - 2.5 gallon fire buckets. Only 2 fire buckets were provided. Provide 1 additional fire bucket.
46 CFR 181.610
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 25 October 2022
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. The provided float-free link was not attached to the vessel. Vessel is restricted to a limited coastwise route no more than 3 NM from shore.
46 CFR 180.130(a)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 25 October 2022
Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free. The provided buoyant apparatus is secured to the vessel with a strap and an expired hydrostatic release. Vessel is restricted to a limited coastwise route no more than 3 NM from shore.
46 CFR 180.130(a)(2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 October 2022
Resolved
All machinery and equipment on board the vessel must be installed and maintained in such a manner as to afford adequate protection from machinery failure. The provided hose end fitting on for the steering system in the rudder room are severely corroded. Renew hose end fittings.
46 CFR 182.100
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 March 2022
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended and the owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. The owner or managing operator failed to provide servicing records for the portable fire extinguishers. Provide servicing records in accordance with NFPA 10. 46 CFR 176.810(b)(iv)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 March 2022
Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06. The marine employer did not have a procedure in place for testing crew members following marine incidents. Provide written procedures for post-incident chemical testing. 46 CFR 16.240
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 March 2022
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel does not have any means to test for presence of alcohol. Provide valid alcohol test devices.
46 CFR 4.06-15 (a)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 March 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating the purpose of the valve and direction of operation. The vessels fuel shutoff valves are not labeled. Properly label fuel shutoff valves. 46 CFR 185.608
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 9 March 2022
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. The hydrostatic release for the EPIRB is expired and shall be replaced. Vessel shall not operate more than 3 nautical miles from land and not more than 20 miles from a harbor of safe refuge until the hydrostatic release is replaced. 46 CFR 185.740(b)
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 March 2022
Resolved
Equipment and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The vessel did not have oxygen onboard as required by Work Instruction 31. The vessel’s crew is prohibited from entering the water until the provisions of Work Instruction 31 are met.46 CFR 176.800 (a)
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 October 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel suffered damaged to the port hull following an allision with the pier while mooring. Vessel is restricted from operating until deemed safe by Marine Inspector, to include inspection of the hull and repairs.
46 CFR 176.600
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 August 2021
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets were not stowed separately from adult size life jackets. Separate child life jackets from adult life jackets.
46 CFR 180.78
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2021
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Three of the four fuel shut off valves did not close properly. Ensure proper closure of manually operated fuel shut off valves.
46 CFR 182.435
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2021
Resolved
Valves for removing water or impurities in fuel strainers must be provided with caps or plugs to prevent fuel leakage. Installed valves did not have plugs. Provide plugs for drain valves for fuel strainers.
46 CFR 182.455(b)(9)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2020
Resolved
The fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The starboard aft fuel tank emergency shut off valve was inoperable. Provide proper operation of the fuel shutoff valve prior to carriage of passengers for hire.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 November 2020
Resolved
Vapor barriers must be provided where flammable and combustible liquids or vapors are present, such as machinery spaces. The forward bulkhead of the engine room was fitted with a vent leading to an unsealed compartment. Seal the forward engine room bulkhead to ensure it is vapor tight prior to carrying passengers for hire.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 November 2020
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. The vessel’s floating waterlight was found to be inoperable. Vessel is restricted to daylight operations only until proper operation of the floating waterlight is proven.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 November 2020
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional inspection deemed reasonable and necessary to determine that the vessel is suitable for the service in which it is employed. The vessel’s AED is expired, and no longer meets the requirements of Work Instruction 31. Vessel must be manned with full complement listed on COI until a new AED is provided onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 November 2020
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart in such a manner to avoid chafing. The electrical wiring under the forward starboard cabinet was not supported. Provide supports IAW 46CFR183.340.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 November 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and the vessel from electrical hazards. The oil pump wiring in the engine room was unconnected and exposed. Remove, properly terminate, or reinstall the oil pump wiring to the satisfaction of the Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2020
Resolved
Flexible nonmetallic hose used in fuel oil systems must meet SAE J-1942. The vessel had an unauthorized priming bulb in the port fuel line. Remove the priming bulb and reinstall the fuel line.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 November 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. The port and starboard battery banks have unmounted, exposed switches. Mount the switch in appropriate enclosures to prevent accidental contact.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 November 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. The vessel’s chart was expired. Provide an up-to-date chart onboard to the satisfaction of the Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 November 2020
Resolved
A hatch exposed to the weather must be watertight. The forward anchor locker hatch on the bow was removed. Reinstall the forward anchor locker hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 August 2020
Resolved
For the purposes of flexibility only, flexible hose installed in lengths of not more than 30 inches and subject to a pressure of not more than 5 psi may meet the following requirements: USCG type A1, A2, B1, or B2 may be accepted in accordance with 33 CFR 183, subpart J. Vessels fuel hose from tank worn and cracking. Hose must be USCG A1 in accordance with 183.558 (b)(2).
43 CFR 182.720 (e)(3)(v)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2020
Resolved
The owner or operator shall make a vessel available for drydock examinations. In accordance with U.S. Coast Guard Marine Safety Information Bulletin 09-20 "Vessel Inspections, Exams, and Documentation", the vessel's required drydock inspection has been deferred 90 days based on objective evidence provided by the owner and/or operator attesting to the vessel being fit for its intended route and service. The vessel's owner or operator shall ensure that the vessel completes a USCG Marine Inspector drydock inspection within 90 days of the drydock due date listed on the its COI. Failure to complete a USCG Marine Inspector attended drydock inspection may result in the vessel being restricted from carrying passengers.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 December 2019
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other
standard specified by the Commandant. The port running
light has 3 out of the 5 LEDs inoperable. It no longer
meets the standard.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 11 December 2019
Resolved
Vessels operated solely within 20 nautical miles of land
must be equipped with a VHF-DSC radiotelephone
installation meeting the requirements of §80.1101(c)(2).
The vessel's VHF-DSC is not properly configured to show/
broadcast the vessel's GPS coordinates and MMSI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 December 2019
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Found the fuel shut off covers require to be screwed off using a crank handle. Establish a more readily accessible method to quickly utilize the fuel shut off valves in the event of a fire.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 December 2019
Resolved
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retro-reflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16) (incorporated by reference; see 46 CFR 175.600). Half of the life jackets have retro-reflective tape that is wore and unsat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2018
Resolved
On a vessel of at least 26 ft in length, a visual and audible alarm must be provided at the operating statoin to indicate high water level; vessel's midships and fwd visual indicators are not functioning. Prove proper operation of visual indicators.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2018
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating; vessel's fwd bilge pump indicator light is not working. Prove proper operation of visual indicator.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 December 2018
Resolved
A hydrostatic release unit when used in a float free arrangement must be approved under approval series 160.062 or 160.162 or other standard specified by the commandant; vessel hydrostatic release unit for life float is expired. Replace HRU. Vessel route restricted to not more than 3 NM from shore
Lifesaving › Lifefloat › Float-free Link
Issued 6 December 2017
Resolved
Replace weak link for life float with model rated for 18 persons.
Lifesaving › Lifefloat › Markings
Issued 6 December 2017
Resolved
Permanently mark name of vessel on life float
Lifesaving › Lifefloat › Paddle
Issued 6 December 2017
Resolved
Lash paddles to life float
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 6 December 2017
Resolved
Emergency escape up forward must be made operable from both sides
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 December 2017
Resolved
Provide fully stocked, approved first aid kit
Navigation › Piloting/Steering › Marine Charts
Issued 6 December 2017
Resolved
Provide up to date charts for areas in which the vessel operates
Engineering › Bilge Water Management System › Not Operational
Issued 6 December 2017
Resolved
Repair visual indicator for forward bilge high water alarm
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 14 September 2016
Resolved
Coaming and gasket for engine hatch damaged, ensure repaired to meet requirements. 46 CFR 179.360
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 September 2016
Resolved
Location of batteries provided no venting, ensure venting for batteries meets requirement. 46 CFR 183.350 (a)
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 September 2016
Resolved
Retro-reflective tape on child size life jacket worn, replace tape to meet requirement. 46 CFR 185.604 (h)
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 14 September 2016
Resolved
Child size life jackets not stowed separately from adult jackets, meet stowage requirements. 46 CFR 180.78 (a)(5)
Documentation › Markings/Placards › Lifejacket Placard
Issued 14 September 2016
Resolved
Ensure life jacket donning instructions posted are for the model of life jackets carried. 46 CFR 185.516
Lifesaving › Lifefloat › Serviceable
Issued 14 September 2016
Resolved
Life float cracked, damaged, and faded, ensure life float meets requirements. 46 CFR 180.175
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 September 2016
Resolved
Circuit breakers shall meet US 489 standard, ensure all circuit breakers meet requirement. 46 CFR 183.380 (m)
Electrical › Electrical Distribution System (service) › Conductor
Issued 14 September 2016
Resolved
Electrical equipment must be protected from corrosive environment, water noted in space for inverter. 46 CFR 183.210
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 September 2016
Resolved
Ensure electrical equipment is maintained, remove corrosion from electrical connectors. 46 CFR 183.200
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 14 September 2016
Resolved
Exposed portion of engine exhaust must be protected, install lagging accordingly. 46 CFR 182.425
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 September 2016
Resolved
Electrical arrangement does not match current line diagram; provide updated line diagram. 46 CFR 177.202
Electrical › Electric Generation Source (service) › Power Requirement
Issued 14 September 2016
Resolved
Current load analysis is incomplete in reflecting current equipment on board. Provide updated load analysis to accurately reflect installed equipment on board. 46 CFR 177.202
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 17 November 2010
Resolved
Found corroded attachment bolt for pilot house overhead hand rail. Replace as original.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 1 December 2009
Resolved
Provide emergency fuel shutoff valve at port forward fuel tank.
Engineering › Bilge Water Management System › Not Operational
Issued 1 December 2009
Resolved
Prove proper operation of high water alarm in the engine room.
Engineering › Bilge Water Management System › Not Installed
Issued 1 December 2009
Resolved
Install high water alarm in forward compartment.
Engineering › Bilge Water Management System › Interface Detector
Issued 1 December 2009
Resolved
Provide visual indicator for automatic bilge pumps, indicating when in operation.
Lifesaving › Lifefloat › Float Free
Issued 1 December 2009
Resolved
Provide float free arrangement for 8 man life float.
Lifesaving › Lifefloat › Painter
Issued 1 December 2009
Resolved
Attach 8 man life float to main painter.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 1 December 2009
Resolved
Renew retro reflective tape for 3 adult and 1 child PFD.
Stability › Watertight Integrity › General
Issued 1 December 2009
Resolved
Verify watertight fit for steering space hatch.
Deck/Cargo › Holds/Tanks › Hatch
Issued 1 December 2009
Resolved
Provide securing device for fish hold hatch.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 1 December 2009
Resolved
Renew missing fasteners for deck hatch hinges.
Engineering › Bilge Water Management System › Pump
Issued 1 December 2009
Resolved
Mount forward and steering space bilge pumps.
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 December 2009
Resolved
Double hose clamp for sewage system hoses.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 1 December 2009
Resolved
Renew fish hold hatch gasket.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 December 2009
Resolved
Remove dead-end wiring at distribution panel.
Lifesaving › Lifefloat › Serviceable
Issued 5 November 2008
Resolved
Found (4) small punctures in the 22 person lifefloat and (1) small puncture in the 8 person lifefloat. Repair using an authorized kit.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 November 2008
Resolved
Found corroded clip attachment between the 8 person lifefloat and the waterlight. Replace clip.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 November 2008
Resolved
Found lifefloats blocking the all-around white nav light. Make alterations to light or lifefloat stowage arrangement to permit 360 degree visibility.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 5 November 2008
Resolved
Found the B-I portable fire extinguisher undercharged. Bottle was recently serviced, 8/08, Owner believe bottle to be leaking. Replace same.
Engineering › Steering Gear System › Linkage
Issued 5 November 2008
Resolved
Found excessive movement at the connection between the steering ram and the tie-rod end. Repair to reduce/eliminate movement of the bolt.
Documentation › Certificates/Documents › FCC SSL
Issued 5 November 2008
Resolved
FCC Staition license and Safety Cert are not onboard. Documents recently ordered. Provide proof of same.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 November 2008
Resolved
Found dead-end wires on stbd side of each propulsion engine. Secure/remove same.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 November 2008
Resolved
Found grounding wire for engine battery system laying in bilge water. Relocate wire to safe location.
Engineering › Fuel Oil Service System › Hose
Issued 5 November 2008
Resolved
Found stbd eng fuel line laying in water in bilge. Relocate/secure same to safe location.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 November 2008
Resolved
Found battery charging wires at batteries in eng compartment in manner of falling into wet bilge. Secure same to secure location.
Navigation › Piloting/Steering › Magnetic Compass
Issued 5 November 2008
Resolved
Found magnetic compass light inop. Make repairs to ensure illumination.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 21 July 2008
Resolved
The grounding strap between the rudder post and hull was broken off. Replace grounding strap for the rudder post.
Documentation › Markings/Placards › Official Number (US)
Issued 21 July 2008
Resolved
The document number for the vessel could not be located in the interior. Permanently mark the vessel interior with the document number. 46CFR67.121.
Documentation › Markings/Placards › Warning Signs
Issued 21 July 2008
Resolved
The emergency escape from the cabin was not marked. Mark the cabin (salon) hatch "EMERGENCY EXIT KEEP CLEAR". (2" high, clearly legible, both sides of hatch)
Construction/Loadline › Hull › Side Shell
Issued 21 July 2008
Resolved
Found delaminating fiberglass port and stbd in the anchor well, forward of the collision bulkhead. Grind to good layer of laminate, and re-glass. Recommend consultation with Force 25 (builders), to determine a preferred lay-up schedule.
Navigation
Issued 26 September 2001
Resolved
PROVIDE LIGHTLIST FOR VESSEL OPERATING AREA IAW 46CFR184.420.
Lifesaving
Issued 26 September 2001
Resolved
PROVIDE HYDRO RELEASE THAT HAS A CURRENT EXPIRATION DATE IAW 46CFR180.64.
Lifesaving
Issued 26 September 2001
Resolved
MARK EMERGENCY ESCAPE IAW 46CFR185.606.
Fire Fighting
Issued 31 October 2000
Resolved
Found vessel to have its fixed fire fighting system agent bottle out of service, required vsl rep to service it to the satisfactiion of the cognizant [name withheld] 46 CFR 176.810 (b).
Lifesaving
Issued 31 October 2000
Resolved
Found vsl to not have PFD donning instructions posted, required vsl rep to post them to the satisfaction of the cognizant [name withheld] 46 CFR 185.516.
Lifesaving
Issued 31 October 2000
Resolved
Found vessel to not have a waterlight for its life ring buoy, required vessel rep to install one to the satisfaction of the [name withheld] 46 CFR 180.70.
Construction/Loadline
Issued 31 October 2000
Resolved
Found vessel to have inoperable high water alarm, required vsl rep to proveit is operable to the satisfaction of the cognizant [name withheld] 46 CFR 182.530.
Documentation
Issued 31 October 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 31 October 2000
Resolved
Found vsl to not have a ship's whistle, required vessel rep to obtain one to the satisfaction of the cognizant [name withheld] 46 CFR Part 86.
Lifesaving
Issued 31 October 2000
Resolved
Found vsl to not have emergency instructions posted, required vsl rep to post them to the satisfaction of the cognizant [name withheld] 46 CFR 185.510.
Navigation
Issued 31 October 2000
Resolved
Found vessel to not have chart of operating area, required vsl rep to obtain one to the satisfaction of the cognizant [name withheld] 46 CFR 184.420.
Lifesaving
Issued 31 October 2000
Resolved
Vessel not ready to perform emergency drills, required vsl rep to perform drills to the satisfaction of the cognizant [name withheld] 46 CFR 176.808 (g).
Fire Fighting
Issued 31 October 2000
Resolved
Found vessel to have inoperable fixed fire fighting system alarms - visual and audible, required vsl rep to prove they are operable to the satisfaction of the cognizant [name withheld] 46 CFR 181.420.
Lifesaving
Issued 7 October 1999
Resolved
Conduct emergency drills to the satisfaction of an attending marine inspector, IAW 46 CFR 185.520, 185.524.
Lifesaving
Issued 7 October 1999
Resolved
Obtain six hand red flares, IAW 46 CFR 180.68.
Lifesaving
Issued 7 October 1999
Resolved
POST PFD DONNING INSTRUCTIONS, IAW 46 CFR 185.516.
Lifesaving
Issued 7 October 1999
Resolved
Attatch 60' lifeline to ring life buoy, IAW 46 CFR 180.70.
Unknown
Issued 7 October 1999
Resolved
Prove compliance with drug testing requirements, IAW 16.230.
Fire Fighting
Issued 8 October 1998
Resolved
Bring fixed fire extinguishing system into compliance with requirements of Subchapter T (181.420).
Engineering
Issued 8 October 1998
Resolved
Label remote fuel shut-offs.
Lifesaving
Issued 8 October 1998
Resolved
Provide retro-reflective tape for ring bouy.
Lifesaving
Issued 8 October 1998
Resolved
Provide 10 adult PFDs and 1 child PFD.
Casualty record · 3
10 September 2014Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 injured · activity 4981059
25 July 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6766914
4 November 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6850288
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.