Records from 1985 to 1994. Most recent: inspection, 28 February 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
28 February 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 855417
22 February 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1164079
22 November 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 844754
18 August 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 831999
13 January 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1136663
2 January 1992
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1007241
22 January 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906502
8 January 1991
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239854
26 March 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 927030
21 March 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1224147
4 January 1990
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 909453
2 March 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1197145
17 February 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1039129
9 September 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1041123
27 May 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1194986
10 February 1988
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1327230
13 January 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1011114
7 January 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1317564
16 January 1987
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1007004
16 January 1987
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1315454
8 January 1987
Deficiency Check · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1005832
19 June 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1309183
10 January 1986
Credit Drydock · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1304463
22 May 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 984025
29 April 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1287049
19 February 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1285184
Deck/Cargo
Issued 2 January 1992
Resolved
REPAIR BRAKE ON PORT ANCHOR WINDLOSS AND PROVE PROPER OPERATION OF ANCHOR AND WINDLOSS.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Engineering
Issued 2 January 1992
Resolved
HYDROSTATICS TESTING OF FOUR (4) AIR RECEIVERS WITNESSED BY THE ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Navigation
Issued 2 January 1992
Resolved
REPLACE ALL NAVIGATIONAL LIGHT BULBS AND CONNECTORS WITH APPROVAL MARINE LIGHTING.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Navigation
Issued 2 January 1992
Resolved
PROVIDE COPY OF RULES OF THE ROAD.
Condition: Unknown
Due 2 February 1992
Resolved 31 January 1992
Deck/Cargo
Issued 2 January 1992
Resolved
INTERNALLY EXAMINE PORT AND STARBOARD AFT BULY TANKS WITNESSED BY THE ATTENDING USCG MARINE INSPECTORS.
Condition: Unknown
Due 2 January 1992
Resolved 2 January 1992
Lifesaving
Issued 2 January 1992
Resolved
PROVIDE ONE ADDITIONAL PARACHUTE FLARES.
Condition: Unknown
Due 2 February 1992
Resolved 3 February 1992
Documentation
Issued 8 January 1991
Resolved
PROVIDE SOLID WASTE MANAGEMENT PLAN AND APPROVED AS PER 33 CFR 151.57 &.59.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Documentation
Issued 8 January 1991
Resolved
PROVIDE UPDATED FIRE CONTROL SAFETY PLAN FOR APPROVAL AS PER 46 CFR 97.36- 1.
Condition: Unknown
Due 8 January 1991
Resolved 8 January 1991
Navigation
Issued 4 January 1990
Resolved
REPAIR LEAKING STEERING RAM ON PORT SIDE.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Accommodation/Occupational Safety
Issued 4 January 1990
Resolved
REPAIR AND PROVE PROPER OPERATION OF VESSELS POTABLE WATER SYSTEM.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Electrical
Issued 4 January 1990
Resolved
REPAIR AND PROVE PROPER OPERATION OF GROUND FAULT DETECTION SYSTEM.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Engineering
Issued 4 January 1990
Resolved
REPAIR AND PROVE PROPER OPERATION OF BOTH MAIN ENGINE REDUCTION GEAR HIGH LUBE OIL TEMPERATURE ALARMS.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Electrical
Issued 4 January 1990
Resolved
PROVIDE EMERGENCY LIGHTING FOR ENGINEROOM.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Electrical
Issued 4 January 1990
Resolved
PROVIDE COVERS FOR GENERATORS OVERSPEED TRIPS.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Engineering
Issued 4 January 1990
Resolved
CLEAN OILY-WATER MIXTURE FROM ENGINEROOM BILGES.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Electrical
Issued 4 January 1990
Resolved
REPAIR AND PROVE PROPER OPERATION OF PORT GENERATOR HIGH JACKET WATER TEMP-ERATURE ALARM.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Navigation
Issued 4 January 1990
Resolved
PROVIDE VESSEL WITH UP TO DATE/CURRENT MAGNETIC COMPASS DEVIATION TABLE.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Construction/Loadline
Issued 4 January 1990
Resolved
REPAIR FRACTURED FRAMES IN STARBOARD AFTER PEAK TANK.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Construction/Loadline
Issued 4 January 1990
Resolved
REPAIR WASTED HOLE IN STERN PLATING STARBOARD SIDE AFTER PEAK TANK IN WAY OF STERN ROLLER.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Construction/Loadline
Issued 4 January 1990
Resolved
REPAIR FRACTURED UNDERDECK BEAM IN FOREPEAK. BEAM IS FORWARD MOST TRANS- VERSE BEAM.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Electrical
Issued 4 January 1990
Resolved
PROVIDE COVERS FOR JUNCTION BOXES ABOVE A/C UNIT ON MESS DECK.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Electrical
Issued 4 January 1990
Resolved
MAKE PROPER ELECTRICAL CONNECTIONS IN JUNCTION BOXES ABOVE A/C UNIT ON MESSDECK.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Electrical
Issued 4 January 1990
Resolved
PROPERLY SUPPORT ELECTRICAL WIRING THROUGH-OUT THE VESSEL IN ACCORDANCE WITH IEEE-45.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Electrical
Issued 4 January 1990
Resolved
REPAIR OR REMOVE UNUSED AND INCOMPLETE READING LAMP IN [name withheld].
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Electrical
Issued 17 February 1989
Resolved
RENEW CORRODED BATTERY BOX NEXT TO FIRE PUMP.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Lifesaving
Issued 17 February 1989
Resolved
REPAIR RESCUE BOAT DAVITS.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Accommodation/Occupational Safety
Issued 17 February 1989
Resolved
REPAIR ALL VENT COVERS TO FWD DECKHOUSE.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Electrical
Issued 17 February 1989
Resolved
PROVIDE PROTECTIVE GUARD FOR #2 GENERATOR FLYWHEEL.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Navigation
Issued 17 February 1989
Resolved
END-FOR-END PIN TO STEERING GEAR RAM.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Fire Fighting
Issued 17 February 1989
Resolved
RENEW FIRE PUMP.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Engineering
Issued 17 February 1989
Resolved
TIGHTEN SHAFT PACKING GLAND TO STARBOARD SHAFT.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Deck/Cargo
Issued 7 January 1988
Resolved
MARK LOCATIONS FOR STOWAGE OF FIXED INDEPENDENT TANKS, AS PER VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Deck/Cargo
Issued 7 January 1988
Resolved
FREE UP AND PROVE OPERATION OF PORT ANCHOR.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Electrical
Issued 7 January 1988
Resolved
PROVIDE METALIC CABLE HANGERS FOR ELECTRICAL WIRES ON MAIN DECK PORT SIDE, JUST AFT OF SUPERSTRUCTURE.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Navigation
Issued 7 January 1988
Resolved
PROVIDE MEANS OF LOCKING NUT ON PORT RUDDER YOKE.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Construction/Loadline
Issued 7 January 1988
Resolved
RENEW BROKEN DRAIN LINE IN STBD AFT BULKTANK VOID SPACE, ON MAIN DECK.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Construction/Loadline
Issued 7 January 1988
Resolved
REMOVE WOODEN PLUG FROM PORT MAIN DECK BALLAST TANK VENT.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Fire Fighting
Issued 7 January 1988
Resolved
PROVIDE UP TO DATE FIRE CONTROL PLAN, MARK LOCATIONS FOR THE 4 B-V FIRE EXTINGUISHERS AND PROVIDE SECURING DEVICES FOR SAME.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Construction/Loadline
Issued 8 January 1987
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF THE AFT, PORT SIDE ENGINEROOM WTD AND THE FORWARD, CENTERLINE ENGINEROOM WTD.
Condition: Unknown
Due 8 January 1987
Resolved 8 January 1987
Electrical
Issued 8 January 1987
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF THE EMERGENCY LIGHTING IN THE CREW'S MESS AND THE GALLEY.
Condition: Unknown
Due 8 January 1987
Resolved 8 January 1987