MAURY USCG vessel records Sign in
← All vessels

CAPTAIN WHITEY GROS

CAPTAIN WHITEY GROS is a 1975 offshore supply vessel. The Coast Guard has recorded 42 inspections since 1984, most recently in June 2012, along with 102 deficiencies and 6 casualty investigations between 2002 and 2014.

Records from 1984 to 2014. Most recent: casualty investigation, 24 July 2014.

Built
1975
Last inspected
17 June 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7417159 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE8889
Flag
UNITED STATES
367087030, 367410880, 368347000 (licence lapsed)
Maury page id
psix-48419

Inspections, by type

…with no type recorded12
Years with a record 20 calendar years (1984–2012)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1022 - Convention (Subpart B), Gross Ton
306 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE8889MMSI 367410880 · expired · compulsorily equipped · granted 20 May 2009, cancelled 20 July 2019
WDC8432MMSI 367087030 · expired · compulsorily equipped · granted 18 January 2006, cancelled 19 March 2016
WCW9766MMSI 368347000 · cancelled · compulsorily equipped · granted 30 June 1997, cancelled 20 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS EMMA MCCALL Research Vessel · MISLE 606642 · 27 October 2006 · activity 2810429

Inspection history · 42

17 June 2012 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4374154
23 January 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4231007
20 September 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4148916
15 July 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3534649
6 August 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3290939
23 April 2007 Deficiency Check · Hull Examination · Cargo Tank Internal · Examination of Repairs · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2914062
12 February 2007 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2871106
11 January 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2854218
30 October 2006 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2810560
27 October 2006 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2810429
24 April 2006 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2632520
17 January 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2567807
16 January 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2567484
12 January 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2565957
15 May 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2362200
5 April 2005 Hull Examination · Re-Inspection · MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2326416
29 April 2004 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2055134
7 April 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2039386
7 April 2004 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2087424
23 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972181
13 February 2003 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1744030
25 December 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1774100
4 March 2002 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1493506
20 July 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448324
20 September 2000 Re-Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1389167
8 December 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812731
29 September 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 788846
6 August 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458665
11 June 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 29608
16 September 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 800790
5 August 1998 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1406362
24 April 1998 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1123978
16 March 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 773209
22 October 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1114994
9 August 1997 COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1388356
2 September 1992 Type not recorded
No type recorded · USCG Arctic District (dp) · USCG Arctic District (CGD-A) · Activity 671174
19 March 1988 Permit to Proceed
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1347985
2 December 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1335342
30 April 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1322159
13 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1288413
21 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287636
15 October 1984 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1283995

Deficiency record · 102

Stability › Watertight Integrity › General
Issued 15 July 2009 Resolved
Hole drilled in bulkhead ivo emergency escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2009
Resolution: Hole was welded closed.
Engineering › Compressed Air System (start air) › Valve
Issued 15 July 2009 Resolved
Pressure relief valve needs replacing, not working properly
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2009
Resolution: New pop off valves installed
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 15 July 2009 Resolved
Excess oil in the bilges need to be removed
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2009
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 15 July 2009 Resolved
No Lifesaving Maintenance record being kept.
Due 15 July 2010
Resolved 19 September 2011
Resolution: Lifesaving Maintenance record onboard. All Sat.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 July 2009 Resolved
Log doesn't contain arrival/departure info IAW 46CFR131.620
Due 15 July 2010
Resolved 19 September 2011
Resolution: Reviewed vessel logs, arrival/departure info contained, but needs additional info. Advised master [name withheld]
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 28 August 2007 Resolved
Remount fire ext #7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Fire Fighting › Fire Hoses › Location
Issued 28 August 2007 Resolved
Remark fire fighting stations
Due 3 September 2007
Resolved 19 September 2011
Resolution: Cleared outstanding deficiency. All Sat.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 August 2007 Resolved
tighten and rehang panal box door at bottom of fwd ladder
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Stability › Watertight Integrity › General
Issued 28 August 2007 Resolved
Seal all cable penetrations in E/R and all other WTB's
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Engineering › Generator (propulsion/auxiliary-electric) › Reverse Power Protection Relay Circuitry
Issued 28 August 2007 Resolved
Repair reverse power relay in #1 & #2 gens
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 28 August 2007 Resolved
Place blanks in all open positions in breaker boxes
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 August 2007 Resolved
clean and remount all E/R deck plates
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 August 2007 Resolved
Cover overhead junction box next to port MDE
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 August 2007 Resolved
Install fuel transfer pump & liquid mud shutdowns that must be reset after operations to prevent being restarted in E/R after being tripped on main deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 August 2007 Resolved
Rework reach rod deck plugs for emergency fuel shutdowns and demonstrate proper use
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 August 2007 Resolved
Remove dead wiring throughout vessel
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Board
Issued 28 August 2007 Resolved
Relabel #3 generator removed E. generator marking. Vsl is not equipped with e. generator
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 August 2007 Resolved
Remove spare batteries from E/R deck and store properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 28 August 2007 Resolved
Reseal wiring case on stbd MDE
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 August 2007 Resolved
Re-fix exhaust lagging throughout E/R
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 28 August 2007 Resolved
Clean off excess oil from stbd MDE and montior for leak
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 28 August 2007 Resolved
reweld pipe support under fire pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2007
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 28 August 2007 Resolved
Seal leak on slop tank piping on port side of E/R
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 August 2007 Resolved
Place cover over battery box under fwd ladder
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Fire Fighting › Fire Pumps › Pressure
Issued 28 August 2007 Resolved
Renew E. fire pump guage
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Engineering › Lubricating Oil Service System › Hose
Issued 28 August 2007 Resolved
Repair hydraulic leak on aft end of stbd MDE
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Lifesaving › Inflatable Liferafts › Servicing
Issued 28 August 2007 Resolved
Reservice both liferafts. Annual service expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 28 August 2007 Resolved
Provide license for chief enginner
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Personnel › Manning/Qualifications › Citizenship Requirements
Issued 28 August 2007 Resolved
Ensure foregn crewmembers do not exceed 25% of required manning as per 46 USC 8103
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 August 2007 Resolved
Tighten up 120V panal on bridge next tp #1 fire ext and seal old screw holes to prevent exposed wiring.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 August 2007 Resolved
Repair leak on OWS and demonstrate proper use.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 August 2007 Resolved
Reseal all ballast and void access plates
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 28 August 2007 Resolved
Remove microwave oven extension cord from galley
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Stability › Watertight Integrity › General
Issued 28 August 2007 Resolved
Adjsut watertight door on 01 aft deck
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Communications › Radio Communications › EPIRB
Issued 28 August 2007 Resolved
Renew EPIRB hydrostatic release
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 August 2007 Resolved
Remove dead wiring from under bridge console
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Stability › Weathertight Integrity › General
Issued 28 August 2007 Resolved
Seal A/C cable bridge bulkhead penetrations and remove old cables
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Construction/Loadline › Penetrations › Weld
Issued 28 August 2007 Resolved
C/R softpatch on vent pipe at stbd overhead next to MDE
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2007
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 11 January 2007 Resolved
PAINT DRAFT MARKS ON BOW AND STERN.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 11 January 2007 Resolved
PROFIDE UPDATED COAST PILOT AND LIGHT LIST.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Operations/Management › Vessel Safety Management › Designated Person(s)
Issued 11 January 2007 Resolved
PROVIDE 1 LIFEOBATMAN
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 11 January 2007 Resolved
REMOVE ALL EXTENSIONS CORDS AND THREE WAY PLUGS.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 11 January 2007 Resolved
REMOVE PAINT FROM BELL
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 January 2007 Resolved
PAINT RUNNING LIGHT BACKGROUND BRACKET MATTE BLACK.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Construction/Loadline › Structures › Superstructure
Issued 11 January 2007 Resolved
REPAIR TONNAGE DOOR ON O1 DECK.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2007 Resolved
INSTALL COVER ON RANGE HOOD LIGHT FIXTURE.
Action required: 705 - Other - as specified
Due 11 February 2007
Resolved 30 August 2007
Fire Fighting › Fire Main › Condition
Issued 11 January 2007 Resolved
SECURE FIRE PUMP GUARD IN ENGINE ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 January 2007 Resolved
REPAIR ELECTRICAL BOX PORT MAIN DECK LOCKER.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 11 January 2007 Resolved
POST FUEL OIL TRANSFER PROCEDURES AT TRANSFER PUMP IN ENGINE ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 January 2007 Resolved
DEMONSTRATE PROPER OPERATION OF OWS.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 11 January 2007 Resolved
DEMONSTRATE PROPER OPERATION OF BOTH MAIN ENGINES.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 11 January 2007 Resolved
INSTALL CHAFFING ON ALL HOSES AS DISCUSSED.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 11 January 2007 Resolved
LABEL ALL ELECTRICAL BOXES AS MARKED AND DISCUSSED.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 11 January 2007 Resolved
DEMONSTRATE PROPER OPERATION OB BOTH GENERATOR OVERSPEED PROTECTION.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2007
Resolved 30 August 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 30 October 2006 Resolved
Prior to departure and cargo operations remove all fuel from starboard day tank.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2006
Resolved 3 November 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 30 October 2006 Resolved
Proceed directly to Bollinger Shipyard to affect permanent repairs to starboard fuel day tank and provide repair proposal to the satisifaction of local OCMI.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 November 2006
Resolved 3 November 2006
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 30 October 2006 Resolved
During transit have dewatering pump on standby.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 November 2006
Resolved 3 November 2006
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 30 October 2006 Resolved
Within 14 days provide local OCMI a copy of oil transfer procedures containing all requirements IAW 33 CFR 155.750.
Condition: Unknown
Due 10 November 2006
Resolved 9 November 2006
Resolution: Reviewed and approved new transfer proceedures.
Construction/Loadline › Penetrations › Weld
Issued 30 October 2006 Resolved
Make permanent repairs to starboard fuel day tank prior to operating under COI.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 November 2006
Resolved 3 November 2006
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 April 2006 Resolved
Radar was not refreshing image.
Condition: Unknown
Due 24 May 2006
Resolved 27 October 2006
Stability › Watertight Integrity › Deadlight Cover
Issued 24 April 2006 Resolved
Provide dogs for OS stateroom port light cover.
Condition: Unknown
Due 24 May 2006
Resolved 27 October 2006
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Number
Issued 24 April 2006 Resolved
Provide 2 additional B-iii extinguishers for machinery spaces.
Condition: Unknown
Due 24 May 2006
Resolved 25 April 2006
Resolution: Provided.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 24 April 2006 Resolved
Stencil life raft stations.
Condition: Unknown
Due 24 May 2006
Resolved 25 April 2006
Stability › Watertight Integrity › Weathertight Enclosure
Issued 24 April 2006 Resolved
Repair all ventilation vent closures (incl 01 level) prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2006
Deck/Cargo › Ballast › Vents
Issued 24 April 2006 Resolved
Provide and install ball checks with goose neck vents.
Condition: Improper Installation
Due 24 May 2006
Resolved 25 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 April 2006 Resolved
Remove extension cord used as permanent wiring to the oiler's stateroom.
Condition: Improper Installation
Due 24 May 2006
Resolved 25 April 2006
Engineering › Fuel Oil Service System › Hose
Issued 24 April 2006 Resolved
Provide chaffing gear on flexible fuel hoses as discussed.
Condition: Improper/Lack of Maintenance
Due 24 May 2006
Resolved 25 April 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 April 2006 Resolved
Seal forward rudder room bulkhead-upper right hand of WTD prior to sailing.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 May 2006
Resolved 25 April 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 24 April 2006 Resolved
Repair all exhaust leaks.
Condition: Improper/Lack of Maintenance
Due 24 May 2006
Resolved 25 April 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 April 2006 Resolved
Repair and label breakers in main deck power panel near engine room exit.
Condition: Unknown
Due 24 May 2006
Resolved 25 April 2006
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 24 April 2006 Resolved
Provide current FCC License and Cargo Ship Safety Radio Certificate.
Condition: Unknown
Due 24 May 2006
Resolved 27 October 2006
Engineering › Fuel Oil Service System › Filter
Issued 13 February 2003 Resolved
REPLACE PLASTIC PLUG ON RACOR UNIT ON PORT GENERATION USING A METALLIC PLUG.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2003
Resolved 13 February 2003
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 13 February 2003 Resolved
ADD 2 BLANKS TO THE 440 VOLT ELECTRICAL PANEL NEAR THE BOW THRUSTER UNIT ON STARBOARD BULKHEAD.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2003
Resolved 13 February 2003
Lifesaving
Issued 6 August 1999 Resolved
DEMONSTRATE COMPLIANCE WITH 8TH COAST GUARD DISTRICT POLICY FOR RESCUE BOATREQUIREMENTS FOR OFFSHORE SUPPLY VESSELS DATED 12NOV98 TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Construction/Loadline
Issued 6 August 1999 Resolved
DEMONSTRATE PROPER OPERATION OF OILY WATER SEPARATOR TO THE SATISFACTION OFATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Engineering
Issued 6 August 1999 Resolved
PROVIDE APPROVED TEST PROCEDURES FOR AUTOMATION OF UNATTENDED MACHINERY SPACES IAW WITH 46 CFR 130.480 TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Fire Fighting
Issued 5 August 1998 Resolved
Repair/replace fire pump pressure guage on bridge
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Electrical
Issued 5 August 1998 Resolved
Missing normal power available indicator bulb on rear electrical switchboard
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Electrical
Issued 5 August 1998 Resolved
Missing ground indicator bulb on rear electrical switchboard
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Deck/Cargo
Issued 5 August 1998 Resolved
REPAIR/REPLACE ANCHOR WINDLASS MOTOR TO WINCH DRIVE CHAIN.
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Deck/Cargo
Issued 5 August 1998 Resolved
REPAIR ANCHOR WINDLASS CONTROLLER FOR MOTOR
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Navigation
Issued 5 August 1998 Resolved
Correct magnetic compass and prove illumination works
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Navigation
Issued 5 August 1998 Resolved
Repair/replace anchor light receptacle
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Electrical
Issued 5 August 1998 Resolved
Provide overspeed trip on #1 and #2 ship service generators in compliance with ABS rule 35.21
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Electrical
Issued 5 August 1998 Resolved
Repair loose wiring in AB room on 01 deck in way of electrical outlet
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Engineering
Issued 5 August 1998 Resolved
Jacket water leak at stbd main diesel engine turbocharger
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Engineering
Issued 5 August 1998 Resolved
Jacket water leak at stbd main diesel engine gauge line to pressure gauge
Condition: Unknown
Due 6 August 1998
Resolved 6 August 1998
Accommodation/Occupational Safety
Issued 9 August 1997 Resolved
PROVIDE/INSTALL VENT SCREEN OVER THE GALLEY STOVE.
Condition: Unknown
Due 9 August 1997
Resolved 9 August 1997
Electrical
Issued 9 August 1997 Resolved
PROVIDE PROPER BLANK FOR VENTILLATION CONTROL PANEL BESIDE WATER TIGHT DOOR, MAIN DECK, LEADING TO ENGINE ROOM.
Condition: Unknown
Due 9 August 1997
Resolved 9 August 1997
Navigation
Issued 9 August 1997 Resolved
MAKE PERMANENT REPAIRS TO STEEIRNG PUMP #1.
Condition: Unknown
Due 9 August 1997
Resolved 9 August 1997
Electrical
Issued 9 August 1997 Resolved
MAKE REPAIRS TO PORT DAY TANK HIGH LEVEL ALARM - DOES NOT ALARM AT PANELS.
Condition: Unknown
Due 9 August 1997
Resolved 9 August 1997
Documentation
Issued 9 August 1997 Resolved
PROVIDE CURRENT DOCUMENTATION CERTIFICATE SHOWING CORRECT TONNAGE & LENGTH.TO BE COMPLETED PRIOR TO OPERATION AS AN OFFSHORE SUPPLY VESSEL.
Condition: Unknown
Due 9 August 1997
Resolved 9 August 1997
Documentation
Issued 9 August 1997 Resolved
PROVIDE AND POST AN APPROVED FIRE CONTROL PLAN PRIOR TO OPERATION.
Condition: Unknown
Due 9 August 1997
Resolved 9 August 1997
Engineering
Issued 9 August 1997 Resolved
MAKE PERMANENT REPAIRS TO THE BOW THRUSTER.
Condition: Unknown
Due 9 August 1997
Resolved 9 August 1997
Documentation
Issued 9 August 1997 Resolved
PROVIDE APPROVED OIL TRANSFER PROCEDURES SPECIFIC FOR VESSEL.
Condition: Unknown
Due 9 August 1997
Resolved 9 August 1997
Documentation
Issued 15 October 1984 Resolved
PERMANENTLY MARK LOADLINE ON HULL.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Electrical
Issued 15 October 1984 Resolved
PROVIDE OPERATIONAL TACHOMETER FOR #2 S/S GENERATOR.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Documentation
Issued 15 October 1984 Resolved
PROVIDE ANNUAL ENDORSEMENT FOR LOADLINE CERTIFICATE.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Construction/Loadline
Issued 15 October 1984 Resolved
EFFECT PERMANENT REPAIRS TO PORT BOLLARD.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Deck/Cargo
Issued 15 October 1984 Resolved
CLEAN OR REPLACE FLAME SCREEN ON FUEL TANK VENTS.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Accommodation/Occupational Safety
Issued 15 October 1984 Resolved
REPAIR OR PROVIDE NEW APPROVED RELIEF VALVES FOR #1 FOR #2 AIR RECEIVERS.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Lifesaving
Issued 15 October 1984 Resolved
PROVIDE LIGHTS AND WHISTLES FOR LIFE JACKETS WHERE MISSING.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984

Casualty record · 6

25 December 2002Routine · role: Involved in a Marine Casualty · activity 1774100
7 April 2004Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2039386
27 October 2006Routine · role: Involved in a Marine Casualty · activity 2810429
7 May 2011Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4008709
23 January 2012Routine · role: Involved in a Marine Casualty · activity 4231007
24 July 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4932775
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

SEABULK NEW JERSEY (2002–2004), MAAD-HUNTER (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.