Records from 1986 to 2015. Most recent: inspection, 14 August 2015.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 44
14 August 2015
Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5216178
3 February 2012
Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4238061
6 July 2011
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4070766
11 February 2010
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3678865
25 June 2008
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3249676
14 June 2007
Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2966144
25 April 2007
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2919117
24 May 2005
Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2367201
16 June 2004
Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2134714
27 May 2003
Hull Examination · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1816168
23 May 2002
Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1626432
16 May 2001
Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1373476
8 May 2000
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1436371
26 April 1999
Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1429132
7 September 1998
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 179435
24 April 1998
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 789407
20 August 1997
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 42970
29 May 1997
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1107698
15 April 1997
Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1368159
28 May 1996
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1469464
7 July 1995
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 883346
28 May 1995
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 22842
25 May 1995
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1182952
24 April 1995
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 871444
19 December 1994
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1156595
5 October 1994
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 684738
21 September 1994
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1172410
19 September 1994
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1180835
6 August 1994
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 12869
8 February 1994
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 852751
1 February 1993
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1412467
2 December 1992
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1408930
2 October 1992
Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1271083
23 March 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1257760
20 March 1991
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 928728
10 April 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 921494
20 February 1990
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 929694
11 October 1989
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1345976
6 March 1989
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1201672
11 April 1988
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1339473
23 February 1988
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1334520
3 March 1987
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1319550
30 April 1986
Credit Drydock
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 989347
26 February 1986
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 988419
Documentation › Certificates/Documents › FCC SSL
Issued 6 July 2011
Resolved
Obtain FCC ship station license-compulsory.
Due 1 May 2012
Resolved 20 August 2012
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 6 July 2011
Resolved
Obtain FCC safety radio certificate.
Due 1 May 2012
Resolved 20 August 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 July 2011
Resolved
Replace Anchor light.
Due 13 July 2011
Resolved 8 July 2011
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 July 2011
Resolved
Provide alcohol test strips.
Due 13 July 2011
Resolved 8 July 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 July 2011
Resolved
Update 1st aid kit-asprin.
Due 13 July 2011
Resolved 8 July 2011
Construction/Loadline › Structures › Transverse Bulkhead
Issued 6 July 2011
Resolved
Fwd BLKHD on STBD side in engine space rotted. Repair to original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2011
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 June 2008
Resolved
There was no proof that the deckhand had successfully passed a pre-employment drug test. Owner required to provide proof of satisfactory pre-employment drug test prior to serving as deckhand with pax on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2008
Resolution: Rcvd emailed copy of enrollment ltr from consortium with deckhand showing "enrolled".
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 June 2008
Resolved
Vsl had 10 serviceable lifejackets. Vsl restricted to 10 total persons onboard until full compliment of life jackets is provided.
Action required: 705 - Other - as specified
Resolved 25 June 2008
Resolution: Owner bought 10 new life jackets.
Engineering › Bilge Water Management System › Pump
Issued 25 June 2008
Resolved
Mid space void electric bilge pump was not funtioning properly. Pump would not turn on with float switch. Vsl required to ensure proper operation of bilge pump prior to carrying pax for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2008
Resolution: Held phone convo with owner that stated he had filled space
Fire Fighting › Nozzles › Approval
Issued 25 June 2008
Resolved
Fire Hose did not have approved nozzle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2008
Resolution: Rcvd photo of approved nozzle on hose.
Construction/Loadline › Structures › Deck Plating
Issued 25 June 2008
Resolved
Port aft deck had an insert (12"x12") that was "spongy" (see attached photo). Issued requirement for owner to make temp repairs until vsl is pulled from water after operation season and permanent repairs can be made.
Action required: 705 - Other - as specified
Due 24 July 2008
Resolved 30 June 2008
Resolution: Held phone con with owner who stated that patch was screwed down and caulking was applied.
Communications › Radio Communications › EPIRB
Issued 14 June 2007
Resolved
Hydrostatic release was expired for EPIRB. Issued requirement to ensure EPIRB is in a float-free arrangement until hydrostatic release is replaced.
Action required: 705 - Other - as specified
Resolved 17 August 2007
Resolution: Owner faxed copy of receipt for hydrostatic release.
Communications › Radio Communications › EPIRB
Issued 16 June 2004
Resolved
Replace expired EPIRB battery and hydro release. Vessel not to operate as an inspected passenger vessel outside of Kachemak Bay until corrected.
Due 30 June 2004
Resolved 25 June 2004
Lifesaving › Hand Flares
Issued 27 May 2003
Resolved
Provide 6 red distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2003
Resolved 6 June 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 27 May 2003
Resolved
Weigh all portable and fixed fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2003
Resolved 6 June 2003
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 16 May 2001
Resolved
Remove duct tape port side exhaust system and properly repair as needed.
Condition: Unknown
Due 15 June 2001
Resolved 17 August 2007
Resolution: There is no duct tape on the exhaust tube.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 16 May 2001
Resolved
Prove proper operation of forward masthead light.
Condition: Unknown
Due 15 June 2001
Resolved 17 August 2007
Documentation
Issued 26 April 1999
Resolved
PROVIDE CURRENT FCC RADIO OPERTOR PERMIT IAW 47 CFR 80
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Fire Fighting
Issued 26 April 1999
Resolved
INSTALL AND PROVE PROPER OPERATION OF FIXED FIRE EXTINGUISHING SYSTEM. PROVIDE SPACE CALCULATIONS AND SYSTEM DESIGN SPECS
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Engineering
Issued 15 April 1997
Resolved
Conduct operational drills in the presence of a marine inspector
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Navigation
Issued 15 April 1997
Resolved
Prove proper operatio of all electronic and navigational equipment
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Navigation
Issued 15 April 1997
Resolved
Repair or replace and prove operation of the anchor light
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Lifesaving
Issued 15 April 1997
Resolved
Procure and install a new battery for the EPIRB
Condition: Unknown
Due 28 May 1997
Resolved 28 May 1997
Electrical
Issued 15 April 1997
Resolved
Install metal straps on electrical cable runs in the engine compartment_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Construction/Loadline
Issued 15 April 1997
Resolved
Repair or replace deck drains in engine compartment
Condition: Unknown
Due 15 April 1997
Resolved 15 April 1997
Navigation
Issued 28 May 1996
Resolved
Repair/replace anchor light and prove operation
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Lifesaving
Issued 28 May 1996
Resolved
Conduct satisfactory underway operational and man overboaerd drills
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Lifesaving
Issued 28 May 1996
Resolved
Label/stencil life float and ring bouy IAW current Coast Guard regulations
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Navigation
Issued 28 May 1996
Resolved
Procure/install a bell IAW Coast Guard regulations
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Engineering
Issued 28 May 1996
Resolved
Label/stencil remote fuel shut off valves IAW current Coast Guard regulations
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Accommodation/Occupational Safety
Issued 25 May 1995
Resolved
Provide installation plans for the new vessel heating system. Plans must include electrical supply system, fuel piping system, exhaust system, compartment ventilation, equipment list and manufacturer's data on heater. System must be approved before being energized with passengers aboard.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Engineering
Issued 25 May 1995
Resolved
Provide hard piping for fuel supply system to main engines and diesel firedvessel heater.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Electrical
Issued 25 May 1995
Resolved
Provide battery trays lined with lead or a similar acid resistant durable material.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Documentation
Issued 20 February 1990
Resolved
PROVIDE A COPY OF THE INLAND NAV RULES AND KEEP ON BOARD VESSEL.
Condition: Unknown
Due 20 February 1990
Resolved 20 February 1990