MAURY USCG vessel records
← All vessels

WILHELM SCHULTE

WILHELM SCHULTE is a 1998 tank ship. The Coast Guard has recorded 12 inspections since 2019, most recently in January 2021, along with 7 deficiencies and 2 operational controls.

Records from 2019 to 2021. Most recent: inspection, 28 January 2021.

Built
1998
Last inspected
28 January 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 January 2021
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2019–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9155626
484312
Flag
ISLE OF MAN
Maury page id
psix-484312

Documentation record

Tonnage as PSIX records it15180 - Convention (Subpart B), Gross Ton
18045 - Dead Weight, Ton
27720 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

28 January 2021 Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7132296
10 December 2020 Deficiency Check · PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7108909
10 December 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7109603
9 December 2020 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7109212
13 January 2020 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7014073
27 December 2019 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6879607
27 December 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6879756
27 December 2019 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7014208
14 November 2019 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6855436
13 November 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6855157
13 May 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6682741
7 March 2019 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6636362

Deficiency record · 7

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 December 2020 Resolved
Emergency shutdown valves in liquid piping should fully close under all conditions within 30 seconds of activation. The number 2 starboard liquid cargo line did not close in over four minutes. The number 2 port liquid cargo line did not close in over 45 seconds, and the number 2 starboard cargo tank top did not close in over one munute. correct prior to conducting cargo
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2020
Resolved 12 December 2020
Resolution: Class Report recieved and approved by the COPT.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 December 2020 Resolved
Firefighting systems and appliances shall be kept in working order and available for immediate use. PSCO observed all dry powder boxes were tied closed in a manner that could delay their use in an emergency.
Action required: 10 - Deficiency Rectified
Due 10 December 2020
Resolved 10 December 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 December 2020 Resolved
Each cargo tank should be provided with a high pressure alarm that sounds on the bridge. PSCO observed the number 3 port tank's high pressure alarm did not activate when tested. Correct prior to conducting cargo.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2020
Resolved 12 December 2020
Resolution: Class Report recieved and approved by the COPT.
01 - Certificates & Documentation › 011 - Ships Certificates › Liquefied Gases in Bulk (CoF/GC Code)
Issued 10 December 2020 Resolved
Information should be onboard and available to all concerned, giving the necessary data for the safe carriage of the cargo. PSCO observed that pentane and pentene are listed on the vessel's certificate of fitness but are not covered in the vessel's operations manual.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2021
Resolved 28 January 2021
Resolution: Received Class Report attesting to cargo information of Pentanes and Pentene was included in cargo operation manual, special requirement for these two cargoes as required in IGC code 18.1.1 was reviewed and found satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 10 December 2020 Resolved
Guardrails fitted on superstructure and freeboard decks shall have at least three courses. PSCO observed the port side deck rail in the vicinity of the cargo heater had two broken courses.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2020
Resolved 28 January 2021
Resolution: Received Class Report attesting to repairs on the broken courses in the rail in the vicinity of the cargo heater.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 10 December 2020 Resolved
After any survey of the ship no changes shall be made without the sanction of the administration, the vessel's IOPP Form A stated the vessel is equipeed with a MEPC.60(33) content meter. PSCO observed the vessel is equipped with a MEPC.107(49) content meter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2021
Resolved 12 December 2020
Resolution: Class Report recieved and approved by the COPT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 December 2020 Resolved
The condition of the ship and its equipment shall be mantained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed the sealing wire for the number 1 starboard cargo tank pressure relief auxiliary setter was installed incorrectly. Additionally the auxillary setter is missing the identification and data plate. Correct prior to conducting cargo.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2020
Resolved 12 December 2020
Resolution: Class Report recieved and approved by the COPT.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.