Records from 1998 to 2025. Most recent: inspection, 30 September 2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 May 2025
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alterations are made. Repairs or alterations that affect the safety of the vessel include, but are not limited to, the: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of livesaving, fire detecting, or fire extinguishing equipment.
Owner/Operator must notify local [name withheld] once repairs have been made in accordance with 46 CFR 119.220 and request Marine Inspector attendance to verify repairs and conduct operational testing.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2025
Resolved 5 June 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 18 February 2025
Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity:
(i) The vital systems listed in § 119.710 of this chapter;
(ii) Interior lighting except for decorative lights;
(iii) Communication systems including a public address system required under § 121.610 of this chapter; and
(iv) Navigation equipment and lights.
(2) Except as provided in § 120.312 of this part, a vessel with batteries of adequate capacity to supply the loads specified in paragraph (a)(1) of this section for three hours, and a generator or alternator driven by a propulsion engine, complies with the requirement in paragraph (a)(1) of this section.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2025
Resolved 19 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 November 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to:
(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical
Vessel has unsafe electrical equipment consisting of exposed wires, open junction boxes, and wires pulled from stuffing tubes etc. Receptacles panels and various portable electrical equipment pose significant safety issues with exposed wiring and improper installation.
Condition: Improper Installation
Action required: 30 - Ship detained
Due 3 December 2024
Resolved 13 December 2024
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 November 2024
Resolved
System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant.
Identified 03 main co2 hoses leaking at the fittings. Additionally CO2 did not discharge in bow thruster room.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 10 December 2024
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 November 2024
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space.
Ventilation was not secured as designed when testing the protected space.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 10 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the
weather deck.
Valve handle did not fully close when exercised.
valve condition is rusted and unreliable.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 10 December 2024
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 November 2024
Resolved
A vessel must be operated in accordance with applicable
and regulations and in such a manner as to afford
adequate precaution against hazards that might endanger
the vessel and the persons being transported.
Vessel failed a fire drill twice showing insufficient knowledge to fight a fire in the engine room. Training was conducted and concepts were still not grasped.
Action required: 30 - Ship detained
Resolved 10 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2024
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Protection must be provided in compliance with § 116.970 of this chapter at such locations where persons or equipment might come in contact with an exhaust pipe.
Vessel's main engine exhaust shows signs of a leak allowing exhaust air to enter the steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Sanitary Facilities
Issued 4 November 2024
Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2024
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 4 November 2024
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2024
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 November 2024
Resolved
46 CFR 114.400 (b)
Accommodation space (5, 6, or 7 depending on size, fire load, and furnishings) means a space that does not contain any cooking appliance other than a microwave oven or other low heat (maximum heating element temperature less than 121 °C (250 °F)) appliance used as a—
(1) Public space;
(2) Hall;
(3) Dining room and messroom;
(4) Lounge or cafe;
(5) Public sales room;
(6) Overnight accommodation space;
(7) Barber shop or beauty parlor;
(8) Office or conference room;
(9) Medical treatment room or dispensary; or
(10) Game or hobby room.
Please refer to both tables 46 CFR 116.415 (b)
and 46 CFR 116.415 (c) as defined by definitions located in 46 CFR 114.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2025
Resolved 15 January 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 October 2024
Resolved
In response to your requested extension to repairs: You have been granted a 45-day extension to conduct repairs by Diversified Fabricators and Erectors in Brunswick, GA. A repair proposal must be submitted to MSU Savannah for review. After approval, coordinate with the local marine inspector during critical repair stages, including crop out and renewal, fit-up, and final weld, along with any other necessary oversight. All other dry dock items should be managed with Sector Charleston.
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years
Action required: 705 - Other - as specified
Due 16 December 2024
Resolved 7 July 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2023
Resolved
46 CFR § 161.002-6
(b) Each fire detection device must comply with the following standards (incorporated by reference, see § 161.002–1) as appropriate:
(c) All devices must be tested by an accepted independent laboratory, as defined in § 159.010 of this subchapter, to meet the marine environment testing requirements in Table 161.002–6(c) of this section. The test parameters are found in IEC 60092–504 (incorporated by reference, see § 161.002–1).
Ships fire detection panel is not operating. IDS came on board and determined the system needs a new panel. Vessel rep instructed to replace in kind/ with USCG approved panel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 November 2023
Resolved 21 November 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2023
Resolved
46 CFR § 119.600
A self-propelled vessel must meet the applicable requirements for main and auxiliary steering apparatus in subchapters F (Marine Engineering) and J (Electrical Engineering) of this chapter.
Vessels rudder angle indicator is not reflecting accurate due to a malfuntioning piece in the steering gear compartment. Vessel has ordered replacement part to ensure accurate rudder angle positions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 November 2023
Resolved 21 November 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2023
Resolved
46 CFR 116.415 (i)
A-Class bulkheads or decks must be composed of steel or equivalent material, suitably stiffened and made intact with the main structure of the vessel, such as the shell, structural bulkheads, and decks. They must be so constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. In addition, they must be so insulated with approved structural insulation, bulkhead panels, or deck covering so that, if subjected to the standard fire test for the applicable time period listed below, the average temperature on the unexposed side does not rise more than 139 °C (250 °F) above the original temperature, nor does the temperature at any one point, including any joint, rise more than 181 °C (325 °F) above the original temperature:
Repair missing and warn insulation in engine room under ladder well on starboard side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2023
Resolved 21 November 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2023
Resolved
Vessel needs to complete underway MOB Drill and sea trials prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 November 2023
Resolved 21 November 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 August 2023
Resolved
46CFR115.700; Permission for repairs and alterations.(a) Repairs or alterations to the hull,machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2023
Resolved 9 November 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 August 2023
Resolved
46CFR121.300;A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2023
Resolved 9 November 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 November 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to: Prevent electrical ignition of flammable vapors. Lazarette port aft light is missing the seal where the electrical cabling enters the light assembly. Complete repairs within 14-days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 13 December 2022
Resolution: Seal replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 November 2022
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Four (04) lights in lazarette are missing the guards. Complete repairs within 14-days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 13 December 2022
Resolution: New light installations with guards installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2022
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Stbd steering gear motor fan inoperable; port steering gear and auxiliary steering gear operable. Complete repairs within 14-days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 13 December 2022
Resolution: Replacement fan installed; tested steering gear, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 November 2022
Resolved
Each outlet or junction box must have a cover unless a fixture canopy, switch cover, receptacle cover, or other cover is used. The cover for junction box in lazarette space was missing post-dry dock, new junction box to be ordered. Complete repair within 14-days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 13 December 2022
Resolution: New junction box installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following: Operational test of all emergency electrical systems. Switchboard indicated a hard ground, diagnosis and repair within 14-days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 13 December 2022
Resolution: Hard ground indictor was blown light, light replaced and generator operational.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 November 2022
Resolved
On vessels with no overnight accommodation; public spaces that may be assumed to be occupied by a large number of persons when passengers are on board need only be served by a manual alarm system that meets the requirements in part 76 in subchapter H of this chapter. The alarm boxes must be located in the vicinity of each required exit, and easily seen in case of need. Engine room manual pull alarm box unable to latch, secured with tape. System operational, replaced pull box within 14-days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 13 December 2022
Resolution: Technician attended 5DEC22, replaced manual pull alarm box. System tested as operational.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 8 November 2022
Resolved
The construction and arrangement of the vessel must allow for safe operation of the vessel in accordance with the terms of its COI. Vessel is safe to transit from Sector Charleston AOR to Savannah in order to complete all final repairs and checks. Vessel needs an in-service exam by MSU Savannah prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2023
Resolution: Final repair checks were inspected from last drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 14 September 2022
Resolved
Each survival craft must be stowed in a position that is readily accessible to crew members for launching and be ready for immediate use, so that crew members can carry out preparations for embarkation and launching in less than 5 minutes. While securing the rescue boat back in the cradle, after the man overboard drill, the wire rope on the winch snapped rendering the rescue boat to be launched in the event of a man overboard. Make appropriate repairs and demonstrate satisfactory operation to the satisfaction of the attending MI prior to carrying passengers.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 September 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2022
Resolved
Unless otherwise specified, vessel owners must pay the fees required by this subpart before inspection or examination services are provided. There is no evidence that vessel inspection user fees were paid. Pay all user fees and provide documentary proof that payment was submitted before any further inspection or examination services are provided to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 19 September 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Enclosure for smoke detector number 48 in engine room had a broken cover plate. Make appropriate repairs to the satisfaction of the attending MI prior to October 13, 2022, otherwise the vessel will be restricted from the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 13 October 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Light fixture was broken behind generator switchboard. Make appropriate repairs demonstrate satisfactory operation to the satisfaction of the attending MI prior to October 13, 2022, otherwise the vessel will be restricted from the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 19 September 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2022
Resolved
Electrical equipment exposed to the weather must be watertight. Electrical outlet by fire station number 9 is not watertight. Make appropriate repairs to the satisfaction of the attending MI prior to October 13, 2022, otherwise the vessel will be restricted from the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 19 September 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Port side main electrical panel was exposed. Make appropriate repairs demonstrate satisfactory operation to the satisfaction of the attending MI prior to October 13, 2022, otherwise the vessel will be restricted from the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 19 September 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 September 2022
Resolved
Nonconducting mats or grating must be provided on the deck in front of each switchboard and, if accessible from the rear, on the deck in the rear of the switchboard. Nonconducting mats were missing from switchboards in engine room. Make appropriate repairs to the satisfaction of the attending MI prior to October 13, 2022, otherwise the vessel will be restricted from the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 19 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 September 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Deck plates in the engine room were not secured creating a trip hazard. Make appropriate to the satisfaction of the attending MI prior to October 13, 2022, otherwise the vessel will be restricted from the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 13 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 September 2022
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. The high jacket water temperature and low oil pressure gauges for the starboard main engine were inoperable. Make appropriate repairs demonstrate satisfactory operation to the satisfaction of the attending MI prior to October 13, 2022, otherwise the vessel will be restricted from the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 19 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2022
Resolved
Nonmetallic piping materials, including nonmetallic flexible hose assemblies, must meet the requirements of § 56.60–25 in subchapter F. 3 inch flex hose on Portside forward bow thruster engine is degraded and needs to be replaced. Make appropriate repairs demonstrate satisfactory operation to the satisfaction of the attending MI prior to October 13, 2022, otherwise the vessel will be restricted from the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 13 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2022
Resolved
Nonmetallic piping materials, including nonmetallic flexible hose assemblies, must meet the requirements of § 56.60–25 in subchapter F. Portside steering gear ram flex hose is degraded and needs to be replaced. Make appropriate repairs demonstrate satisfactory operation to the satisfaction of the attending MI prior to October 13, 2022, otherwise the vessel will be restricted from the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 13 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operations. Bow thruster shut off not marked. Make appropriate repairs demonstrate satisfactory operation to the satisfaction of the attending MI prior to October 13, 2022, otherwise the vessel will be restricted from the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 19 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 September 2022
Resolved
Auxiliary machinery of the internal combustion piston type must comply with the provisions of this part. Bow thruster engine is discharging exhaust in to the space, ensure engine is arranged in accordance with manufacture. Make appropriate repairs demonstrate satisfactory operation to the satisfaction of the attending MI prior to October 13, 2022, otherwise the vessel will be restricted from the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 13 October 2022
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 14 September 2022
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan is on the ship and that each person handling garbage follows the plan. The master was unable to produce a waste management plan during the inspection. Develop a garbage management plan to the satisfaction of the attending MI prior to October 13, 2022, otherwise the vessel will be restricted from the carriage of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 19 September 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 September 2022
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. During a test of the emergency lighting, the exit sign and emergency light on the aft stairwell on the main deck was inoperable. Crew replaced the light and it was found to be fully operational – corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 19 September 2022
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2022
Resolved
If during the inspection of a vessel, the vessel or its equipment is found not to conform to the requirements of law or the regulations in this subchapter, the marine inspector will point out deficiencies observed and discuss all requirements with the owner, managing operator, or a representative thereof. Attending MI identified a fault for the "first deck bathroom head pull-station" on the fire alarm detection panel. Require third-party technician report of functionality.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2022
Resolved 20 May 2022
Resolution: Attending MI received third-party technician report stating pull-station had been replaced and system fully operational.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Procedure for inspection, reporting and correcting unsafe conditions and for investigating a
Issued 5 May 2022
Resolved
Immediately after addressing resultant safety concerns, the owner or master shall notify the nearest OCMI whenever a vessel is involved in a marine casualty consisting of an occurrence adversely affecting the vessel's seaworthiness or fitness for service... marine casualty includes: fire, flooding, [or] damage to fixed fire extinguishing systems, lifesaving equipment, power-generating equipment, or bilge pumping systems. On 04/30/2022, the vessel had an unintended ingress of water into the engine room due to a failed plug on the port generator heat exchanger. This failure caused flooding of the engine room to a level exceeding the high water level alarm in the bilge. The vessel used the bilge discharge to de-water the space, discharging into the Brunswick River, a navigable waterway of the U.S. The cognizant OCMI was not notified of the marine casualty.
Action required: 30 - Ship detained
Resolved 12 May 2022
Resolution: SIO attended vessel and started investigation proceedings.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 May 2022
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each normally unmanned engine space. Attending MI tested the high water level alarm in the engine room bilge and observed a only visual alarm at the operating station, the audible alarm was inoperable.
Action required: 30 - Ship detained
Resolved 6 May 2022
Resolution: Attending MI witnessed satisfactory operation of high level alarm for engine bilge.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 5 May 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel may not be made without the approval of the OCMI, except during an emergency. When repairs are made during an emergency, the owner, operator, or master shall notify the OCMI as soon as practicable. Attending MI identified holes on the aft deck which had been patched with an unapproved epoxy repair. The aft deck is above the lazarette space and is normally only accessible to crew to transit to the engine room. In an abandon ship situation, passengers would egress from the vessel into liferafts from the aft deck. The OCMI had not been notified of these repairs. Provide repair plan to cognizant OCMI for approval prior to beginning repair work. Repairs affected will be of a temporary nature until vessel enters drydock on 11/01/2022 to conduct crop and renew of aft deck metal plating.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 May 2022
Resolution: Attending MI verified installation of plates over back deck, deemed a suitable temporary repair until vessel attends dry dock (Nov 2022).
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2022
Resolved
Piping used in a vital system must meet the requirements of Subchapter F. Attending MI identified a soft patch on the raw water discharge pipe for the port main engine. Additionally, the raw water discharge pipe for the port generator had two welds wrapped with flex-tape. The OCMI had not been notified of these repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 May 2022
Resolution: Attending MI verified piping had been replaced, conducted satisfactory opertional test.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2022
Resolved
Exhaust gas must not leak from the piping or any connections. Attending MI identified an exhaust leak into the lazarette space. The following defects were found: port generator exhaust muffler - 2 cracked welds; port main engine exhaust muffler - 3 cracked welds and a hole on top of the muffler under the outboard bracket; and stbd generator exhaust muffler - 01 cracked weld. Provide repair plan to cognizant OCMI for approval prior to start of work. Repairs must be verified complete by attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 May 2022
Resolution: Attending MI verified suitable repairs, witnessed satisfactory operational test and observed no leaks.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 5 May 2022
Resolved
The person in charge of an oceangoing ship that cannot discharge oily mixtures into the sea in compliance with paragraphs (a), (b), (c), or (d) of this section, must ensure that those oily mixtures are: (1) retained on board; or (2) discharged to a reception facility. Attending MI identified oily-water mixture in the engine room bilge at a level that required discharge to reception facility. Provide evidence of discharge of oily-water mixture to authorized reception facility prior to movement. In addition, Owner or Master shall provide a plan that describes the retention and disposal of oily-water mixture created by vessel, to the satisfaction of the OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2022
Resolved 17 June 2022
Resolution: O/O provided oily-water management plan to the satisfaction of the attending MI.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 14 September 2021
Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. During a review of the marine employers drug and alcohol program, it was discovered that eleven (11) persons with safety sensitive positions had no proof of preemployment testing/ or in random program . Provide preemployment and Random enrollment for all persons assigned to safety sensitive duties to the satisfaction of an attending Coast Guard Marine Inspector prior to October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 14 October 2021
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 14 September 2021
Resolved
Vessels to which sub chapter K applies must meet the applicable provisions in sub chapter S (Subdivision and Stability) of this chapter. The company made several changes to the second deck as documented in the vessel's stability letter and stability information. Vessel was calculated for stability indicating 11 tables on the second deck. These tables were replaced by 43 slot machines. Provide updated calculations with the weight changes by the addition of 43 slot machines on the second deck and provide an amended stability letter to the satisfaction of an attending Coast Guard Marine Inspector prior to October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 7 December 2021
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 14 September 2021
Resolved
The hull, structural bulkheads, columns and stanchions, superstructures, and deck houses on a sub chapter K vessel must be composed of steel or equivalent material to provide adequate structural fire protection. There was a small hole identified inside the forward overhead, starboard side leading into the steering gear compartment as pointed out to the vessel representative. Make necessary and adequate repairs to the small hole as identified to the satisfaction of an attending Coast Guard Marine Inspector prior to
October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 7 December 2021
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 14 September 2021
Resolved
The hull, structural bulkheads, columns and stanchions, superstructures, and deck houses on a sub chapter K vessel must be composed of steel or equivalent material to provide adequate structural fire protection. There was a small hole identified on the back deck on the open deck as pointed out to the vessel representative. Make necessary and adequate repairs to the small hole as identified to the satisfaction of an attending Coast Guard Marine Inspector prior to October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 7 December 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 14 September 2021
Resolved
Windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions. The windows on the navigation bridge did not provide adequate protection from the elements and showed signs of leaking. Address all the leaks and ensure all windows on the navigation bridge are weather tight to the satisfaction of an attending Coast Guard Marine Inspector prior to October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 14 October 2021
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 14 September 2021
Resolved
Each vessel that relies on electricity to power the electrical loads must be arranged so that the loads can be energized from two sources of electricity. None of the gauges on the standby generator were operating properly while under load. Make repairs to the standby generator and demonstrate proper operation to the satisfaction of an attending Coast Guard Marine Inspector prior to October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 7 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 September 2021
Resolved
A door in a stair tower, stairway, and main vertical zone bulkhead of a sub chapter K Vessel must have a hold back mechanism for a door that will allow the door to be released locally, on loss of power or upon signal from the control space. The hold back devices on doors in the main vertical zone on two doors were manual release only. Remove all hold back devices and test all fire screen doors to the satisfaction of an attending Coast Guard Marine Inspector prior to October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 14 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 September 2021
Resolved
A door in a stair tower, stairway, and main vertical zone bulkhead of a sub chapter K Vessel must have a hold back mechanism for a door that will allow the door to be released locally, on loss of power or upon signal from the control space. The hold back device on FSD #3 on the third deck was not releasing upon control from the operating station. Make repairs to the controls for the fire screen door releases and demonstrate proper operation of all fire screen doors to the satisfaction of an attending Coast Guard Marine Inspector prior to October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 14 October 2021
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 14 September 2021
Resolved
Materials used in piping systems on a sub chapter K vessel must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] an operational test of the port side ship service generator, a leak was observed at the raw water intake of the generator. Arrest the leak in way of the raw water intake and make necessary repairs to the satisfaction of an attending Coast Guard Marine Inspector prior to October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 14 October 2021
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 14 September 2021
Resolved
Materials used in piping systems on a sub chapter K vessel must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] an operational tests in the machinery space, a leak was observed in both the port and starboard side main heat exchangers. Arrest the leak in way of the raw water intake and make necessary repairs to the satisfaction of an attending Coast Guard Marine Inspector prior to October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 14 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 14 September 2021
Resolved
At each inspection for certification and at every other vessel inspection of a sub chapter K vessel, the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. During a walk through of the machinery space there was a significant accumulation of oil in the engine room bilge. Remove all excess oil and properly dispose any oil or oily rads and pads. Ensure bilges have been cleaned to the satisfaction of an attending Coast Guard Marine Inspector prior to October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 14 October 2021
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 14 September 2021
Resolved
Indication of the rudder angle on a sub chapter K vessel must be provided both at the main steering station in the pilothouse and in the steering-gear compartment. The rudder-angle indicator must be independent of control systems for steering gear. The rudder angle indicator on the bridge was not properly mounted or secured. Properly mount the rudder angle indicator in a position where the person on the helm can visually see the degree of rudder applied to the satisfaction of an attending Coast Guard Marine Inspector prior to October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 14 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 September 2021
Resolved
Materials used in piping systems on a sub chapter K vessel must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] a walk through of the steering compartment, a small raw water leak was observed on the port side, outboard main engine exhaust. Arrest the leak in way of the main engine exhaust and make necessary repairs to the satisfaction of an attending Coast Guard Marine Inspector prior to October 13, 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 14 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 July 2021
Resolved
Fire detection panel was displaying a trouble alarm, smoke detector on main deck near cash window was faulty.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2021
Resolved 26 July 2021
Resolution: Fire servicing technician replaced smoke detector and reset panel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 July 2021
Resolved
Emergency escape lighting over STBD generator was inoperative.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 6 August 2021
Resolved 26 July 2021
Resolution: Light was replaced prior to completing inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2021
Resolved
STBD generator fuel filters are missing the heat shield on the fuel bowls.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2021
Resolved 3 August 2021
Resolution: Picture verification, Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 January 2021
Resolved
Each vessel operating in warm water may be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. 9 out of 18 - 22 Person life floats were found in serviceable. Vessel is restricted to 396 total people to include passengers and crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2021
Resolved 18 May 2021
Resolution: Vessel installed 7 - 50 person IBAs and removed Life floats.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 January 2021
Resolved
A weathertight door must be provided for each opening located in a deck house or companionway. Both starboard and port weathertight doors on the main were found to not be weathertight as light could be seen from the outside. Also, gasket material was missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2021
Resolved 1 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2021
Resolved
All cable and wire must be protected from the weather. Vessel's shore tie receptacle is missing its weathertight caps and enclosures to ensure protection from the elements.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2021
Resolved 1 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2021
Resolved
Equipment mounted on a hinged door of an enclosure must be constructed or shielded so that a person will not accidentally contact energized parts of the door mounted
equipment when the door is open and the circuit is
energized. Panelboards are missing blanks and/or breaker
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2021
Resolved 1 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Electrical fan in the galley port side wss found to have exposed wiring and capacitors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2021
Resolved 1 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Freshwater system in the engine room pressure switch was missing a cover plate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2021
Resolved 1 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 January 2021
Resolved
Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. On the main deck aft overhead, wire cable was found hanging by its wire and the conduit was not properly mounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2021
Resolved 1 March 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 January 2021
Resolved
The certificate of inspection (COI) issued by an Officer in Charge, Marine Inspection (OCMI), to a vessel required to be inspected under 46 U.S.C. 3301 specifies
the minimum complement of officers and crew necessary for
the safe operation of the vessel. After reviewing the
logbook, it was determined the crew was working beyond
the 12 hour within 24 hour work/rest requirement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2021
Resolved 1 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 January 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. The electrical fan over the waterheater on the second deck next to the lifejackets had exposed wires.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2021
Resolved 1 March 2021
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 6 January 2021
Resolved
Users must always maintain their Automatic Identification System in an effective operating condition and ensure the accuracy of all broadcasted dynamic, static and voyage information in accordance with 33 CFR 164.46(d). This vessel currently is transmitting a wrong value for the vessel’s IMO number and all the Antenna Distances (ANT A, ANT B, ANT C, and ANT D) are showing zero values. Load the correct data for the vessel into the AIS to the satisfaction of an attending Coast Guard Marine Inspector prior to
February 6, 2021.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2021
Resolved 1 March 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 December 2020
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is overdue for an Annual Inspection. Vessel is restricted from carrying passengers until an Annual Inspection is completed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 December 2020
Resolved 7 January 2021
Resolution: Vessel completed an Annual Inspection on 07Jan2021.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 December 2019
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each normally unmanned space. Bilge high level alarm failed to activate in the Bow Thruster Room, Main Engine Room, Aux Engine Room (AC Room) and the Steering Gear Room and does not meet the minimum requirements as required by 46CFR119.530(a)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 12 December 2019
Resolution: On site def check, Sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 11 December 2019
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Vessel's main engine exhaust has a leak in the lazarette/steering compartment that allows seawater to enter the space from the stern/transom of the vessel. The exhaust piping penetrates the stern of the vessel roughly 6 inches above the waterline. The hole in the exhaust piping allows water into one of the vessel's watertight compartments. The hole is roughly 1/4" by 6" long
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 December 2019
Resolution: Vessel replaced the exhaust pipe; all sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 11 December 2019
Resolved
Fuel Piping shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Vessels Fuel Oil Shut off in engine room was not operating properly and does not meet the minimum requirements as required by 46CFR119. 455(b)(3).
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 20 December 2019
Resolution: Tested operation, Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 December 2019
Resolved
Piping used in a vital system must meet 46CFR56.60 in subchapter F of this chapter. Vessels vital raw water discharge metallic piping was modified to include PVC (Plastic) piping and does not meet the minimum requirements as required by 46CFR119.710(c).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 December 2019
Resolved
Piping used in a vital system must meet 46CFR56.60 in subchapter F of this chapter. Vessels vital raw water metallic discharge piping aft port side engine room was modified to include a nonmetallic soft patch and does not meet the minimum requirements as required by 46CFR119.720. The vessel will be restricted from departure and carrying passengers after January 11, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 10 January 2020
Resolution: Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 December 2019
Resolved
Nonmetallic piping materials, including nonmetallic flexible hose assemblies, must meet the requirements of 46CFR56.60–25 in subchapter F of this chapter. Vessel’s raw water discharge piping for generator in the engine room was modified to include nonmetallic piping materials and does not meet the minimum requirements as required by 46CFR119.720. The vessel will be restricted from departure and carrying passengers after January 11, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 10 January 2020
Resolution: Sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 December 2019
Resolved
A hatch exposed to the weather must be watertight. Vessels steering gear escape hatch coaming is wasted and not providing watertight integrity as required by 46CFR 116.1160 (a).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2019
Resolution: Vessel repaired the aft steering gear watertight hatch.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2019
Resolved
Electrical equipment used in the machinery space must be dripproof. Vessel has failed drip proof and abrasion protection wiring leading in to top aft engine in the bow thruster space and does not meet the minimum requirements as required by 46CFR120.210.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating able seafarer deck/engine and electro-technical
Issued 11 December 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2019
Resolution: Vessel provided a QMED.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 11 December 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel has dead end wiring starboard side aft engine in the bow thruster space and does not meet the minimum requirements as required by 46CFR120.200(a).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 December 2019
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. Vessels vital raw water discharge piping was leaking inlet side of cooler on the engine in the bow thruster space and does not meet the minimum requirements as required by 46CFR119.200 (a). The vessel will be restricted from departure and carrying passengers after January 11, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 10 January 2020
Resolution: Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 December 2019
Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, cover, or rail. Vessels turbo air inlet for bow thruster engine is exposed does not meet the minimum requirements as required by 46CFR116.960.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2019
Resolution: Sat
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 11 December 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel has dead end wiring port side forward engine in the bow thruster space and does not meet the minimum requirements as required by 46CFR120.200(a).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 11 December 2019
Resolved
Each pressure type wire connector and lug must meet UL 486A, Wire Connectors and Soldering Lugs for Use With Copper Conductors, Vessel is utilizing unapproved pressure wire connectors in the bow thruster space and does not meet minimum standard as required by 46CFR120.340(i). The vessel will be restricted from departure and carrying passengers after January 11, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 10 January 2020
Resolution: Sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 11 December 2019
Resolved
Each window must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Vessels window on the main deck starboard side forward is broken and does not meet the minimum requirements as required by 46CFR116.1020.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2019
Resolved
Electrical equipment exposed to the weather must be watertight. Electrical cable leading in to anchor winch enclosure on the forecastle is not watertight and does not meet the minimum requirements as required by 46CFR120.210(b).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2019
Resolved
Electrical equipment exposed to the weather must be watertight. Electrical cable leading in to and out of anchor winch box controller on the forecastle is not watertight and does not meet the minimum requirements as required by 46CFR120.210(b).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel has un supported light fixture and junction box located on the forecastle of the vessel and does not meet the minimum requirements as required by 46CFR120.200. The vessel will be restricted from departure and carrying passengers after January 11, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 10 January 2020
Resolution: Sat
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 11 December 2019
Resolved
The use of twist-on type wire nuts is permitted as long as it is made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Vessel is utilizing twist-on type wire nuts for light fixtures but are not in an enclosure and further does not meet minimum standard as required by 46CFR120.340(i).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 11 December 2019
Resolved
The use of twist-on type wire nuts is permitted as long as it is made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Vessel is utilizing twist-on type wire nuts for the HVAC chiller pump and it is not in an enclosure and further does not meet minimum standard as required by 46CFR120.340(i) and (g).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The 2 HVAC control panels covers in way of HAVAC units did not have covers on the control panels located in the HVAC control space in accordance with 46 CFR120.200(b).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 December 2019
Resolved
The dimensions of a means of escape must be such as to allow easy movement of persons when wearing life jackets. There must be no protrusions in means of escape that could cause injury, ensnare clothing, or damage life jackets. Vessel’s means of escape pathways are limited in the AC Room due to storage of boxes and general lack of cleanliness (Refrigerant bottles that are not secure) and does not meet the minimum requirements as required by 46CFR116.500(e).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2019
Resolved
Electrical equipment used in a machinery space must be dripproof. Vessel has failed dripproof on number 49 heat/smoke detector in the engine room that does not meet the minimum requirements of electrical equipment used in machinery spaces as required by 46CFR120.210. The vessel will be restricted from departure and carrying passengers after January 11, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 10 January 2020
Resolution: Sat
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 December 2019
Resolved
The dimensions of a means of escape must be such as to allow easy movement of persons when wearing life jackets. There must be no protrusions in means of escape that could cause injury, ensnare clothing, or damage life jackets. Vessel’s means of escape pathways are limited in the Engine Room due to storage of un secured drums and general lack of cleanliness and does not meet the minimum requirements as required by 46CFR116.500.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 11 December 2019
Resolved
Each pressure type wire connector and lug must meet UL 486A, “Wire Connectors and Soldering Lugs for Use With Copper Conductors,” or other standard specified by the Commandant. Vessel is utilizing unapproved pressure wire connectors aft port side generator battery box and the wire is not protected by sheathing and does not meet minimum standard of splices shall be made by a pressure wire connector (UL 486A) as required by 46CFR120.340(i). The vessel will be restricted from departure and carrying passengers after January 11, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 10 January 2020
Resolution: Sat
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 11 December 2019
Resolved
Tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant materials, adequately protected from mechanical damage, and provided at the tank connections with devices that will automatically close in the event of rupture of the gauge or gauge lines. Vessel’s Tubular gauge glass is not adequately protected from mechanical damage due to loose fittings as required by 46CFR119.440(a)(7).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 December 2019
Resolved
A hatch exposed to the weather must be watertight. Vessel’s engine room escape hatch coaming is wasted and a securing dog is missing and not providing watertight closure as required by 46CFR 116.1160. The vessel will be restricted from departure and carrying passengers after January 11, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 10 January 2020
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2019
Resolved
Electrical equipment used in a machinery space must be dripproof. Vessel has failed drip proof and missing a control switch for the potable water system and does not meet the minimum requirements of electrical equipment used in machinery spaces as required by 46CFR120.210.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2019
Resolved
Electrical equipment used in a machinery space must be dripproof. Vessel has failed drip proof protection for the HVAC panel (Water in the panel) and does not meet the minimum requirements of electrical equipment used in machinery spaces as required by 46CFR120.210.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2019
Resolved
Electrical equipment used in a machinery space must be dripproof. Vessel has failed drip proof on 2 lights that does not meet the minimum requirements of electrical equipment used in machinery spaces as required by 46CFR120.210.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 December 2019
Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. Vessels electrical shore tie penetrations (2 locations) in steering gear room do not prevent the passage of flame and smoke for one hour as required by 46CFR116.415. The vessel will be restricted from departure and carrying passengers after January 11, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 10 January 2020
Resolution: Sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2019
Resolved
Electrical equipment used in a machinery space must be dripproof. Vessel has failed drip proof on port side steering control box and does not meet the minimum requirements of electrical equipment used in machinery spaces as required by 46CFR120.210.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 11 December 2019
Resolved
Electrical equipment used in a machinery space must be dripproof. Vessel has dead end wiring inside starboard steering control box and does not meet the minimum requirements of electrical equipment used in machinery spaces as required by 46CFR120.210. The vessel will be restricted from departure and carrying passengers after January 11, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 10 January 2020
Resolution: Sat
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 11 December 2019
Resolved
Each distribution panel or switchboard must be totally enclosed and of dead front type. The panel board located on the starboard side main deck going below decks has missing breakers that exposes the internals of the panel board as required by 46CFR120.330(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 11 December 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions, protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock, minimize accidental personnel contact with energized parts; and prevent electrical ignition of flammable vapors. The number 1 shore tie is spliced and unprotected and does not meet the minimum requirements as required by 46CFR120.200. The vessel will be restricted from departure and carrying passengers after January 11, 2020 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2020
Resolved 10 January 2020
Resolution: Sat
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 December 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 11 December 2019
Resolved
When life floats are stowed in tiers, the separate units must be kept apart by spacers. Vessel’s life floats are not properly spaced with a spacer by 46CFR117.137(f).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 December 2019
Resolved
Each lifejacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel’s name. Lifejackets located on the 2nd deck aft located on the weatherdeck need to be relabeled with the vessel’s name as the name of vessel is not clearly legible as required by 46CFR122.604(b).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 11 December 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. The electrical junction box located on the aft stairwell between the 2nd and 3rd deck is not properly mounted to the vessel’s structure as required by 46CFR120.200(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 December 2019
Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. The expiration date of the battery may be marked on the battery in clearly legible letters or the owner or managing operator may have a record of the expiration date from the manufacturer of a battery marked with a serial number. The vessel’s lifefloat batteries were found expired as required by 46CFR122.726(d).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 11 December 2019
Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. The expiration date of the battery may be marked on the battery in clearly legible letters or the owner or managing operator may have a record of the expiration date from the manufacturer of a battery marked with a serial number. The vessel’s aft lifering waterlight battery was found expired with the the incorrect type of battery as determined by the waterlight manufacturer as required by 46CFR122.726(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
Resolution: Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 December 2019
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Vessel has a bag covering the bow thruster bilge suction rendering the system ineffective and does not meet the minimum requirements as required by 46CFR119.500(a)
Action required: 10 - Deficiency Rectified
Resolved 12 December 2019
Resolution: Marine Inspector directed vessel rep to remove the bag, they were unaware the bag was covering it.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 10 December 2018
Resolved
Update/Evaluate the approved Fire Control Plan for the vessel to reflect the space designation of the small galley space on the third deck, port side. This space was initially designated as a low risk service space (08) but has an oven in the space that has capability to produce heat above 250 degrees Fahrenheit. According to the definitions in 46 CFR 114.400 this space should be designated as a high risk service space (09). Upon
determination/clarification of this space, ensure the suitability of the fire doors within the space. This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 10 December 2018
Resolved
The coaming in the doorway to the machinery space from the main deck aft is wasted. Make permanent repairs to the coaming to ensure the watertight integrity of the vessel in accordance with 46 CFR 116.116 (d)(1).
This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 December 2018
Resolved
Identify and secure the ground fault observed on the vessel as indicated on the generator switchboard in accordance with 46 CFR 120.378
This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 December 2018
Resolved
Repair or replace four emergency escape lighting in accordance with 46 CFR120.432. This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2018
Resolved
Properly secure the cover in way of the electrical panel located in the third deck small galley in accordance with 46 CFR 120.330. In addition, provide a suitable door that closes and is capable of being secured. This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 December 2018
Resolved
Remove all dead end wiring in the galley located on the third deck, port side aft in accordance with 46 CFR 120.200(b).
This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2018
Resolved
Properly secure the cover in way of the electrical panel located in the Engine Room in accordance with 46 CFR 120.330. This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 December 2018
Resolved
Provide suitable lagging around the dry exhaust piping in way of the bow thruster in accordance with 46 CFR 116.970. This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2018
Resolved
Identify and eliminate water leaking on top of generator battery box in accordance with 46 CFR 120.200. This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 10 December 2018
Resolved
Demonstrate proper operation of the mechanical ventilation damper located in the machinery space, port side in accordance with 46 CFR 119.465(h). The dampers were not closing to ensure an airtight seal in the event the fixed gas fire extinguishing system is engaged. This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 10 December 2018
Resolved
Demonstrate proper operation of the mechanical ventilation damper located in the galley on the third deck, port side, aft in accordance with 46 CFR 116.610. This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 10 December 2018
Resolved
Make repairs and demonstrate proper operation of the ventilation fan located in the CO2 cylinder storage space in accordance with 46 CFR 116.600. This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 December 2018
Resolved
Provide Spanner Wrenches for each fire hydrant in accordance with 46 CFR 118.310(e). This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 December 2018
Resolved
Properly mount in an approved bracket for the portable fire extinguisher located at the exit to the machinery space in accordance with 46 CFR 118.500(d). This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 December 2018
Resolved
Provide a life line in way of one (01) life ring buoy that is at least 60 feet in accordance with 46 CFR 117.70(c)
This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 December 2018
Resolved
Properly mark the life jacket storage locker located on the second deck, aft weather deck with the total number of adult lifejackets stowed inside in accordance with 46 CFR 122.604(f) This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not
corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 10 December 2018
Resolved
Properly demonstrate the deployment of a sampling of the life floats located on the upper deck of the vessel to ensure the operational readiness and current arrangement and to ensure the familiarity of the vessel's crew in
accordance with 46 CFR 117.130(a) This deficiency must be corrected no later than January 9, 2019 to the
satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: Did not conduct due to weather conditions, reschedule TBD
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 10 December 2018
Resolved
Provide a corrosion resistant tag with permanently marked on it the date the new fall was installed and If the fall has been turned end for end, the date it was turned in accordance with 46 CFR 122.704(c). This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: Owner provided evidence of purchase date, and will be provided at future inspections vice the tag.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 10 December 2018
Resolved
Make necessary repairs to the broken t-handle in way of the emergency fuel shut down servicing the tank in the bow thruster space and demonstrate proper operation of the shut down in accordance with 46 CFR 119.455(b)(3)
This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 December 2018
Resolved
During a walk around of the vessel spaces, there was no fire detection system as indicated on the vessels fire control plan in the galley space on the third deck port side. Provide an approved fire detection system in accordance with the Fire Control Plan as required in 46 CFR 116.530 or provide documentation that fire detection is not needed in this space.
This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 December 2018
Resolved
Provide an additional portable fire extinguisher classified as a 40 B:C in the vicinity of the exit to the bow thruster space in accordance with the required portable fire extinguisher table in 46 CFR 118.500(a). This space is classified as as a machinery space as defined in 46 CFR 114.400 and is required to be protected by a portable 40 B:C fire extinguisher near the exit. This deficiency must be corrected no later than January 9, 2019 to the satisfaction of an attending Coast Guard Marine Inspector. If it is not corrected by this date, the vessel will not be authorized to carry passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2019
Resolved 9 January 2019
Resolution: On scene verification satisfactory
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 November 2018
Resolved
All vessels except unmanned barges shall be provided with a satisfactory bilge pumping plant capable of pumping from and draining any water tight compartment
Vessel bilge piping was missing multiple strainer boxes and had piping alterations. Vessel must prove system operation in each watertight space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2018
Resolution: Onsite verification sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 November 2018
Resolved
The installation of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph.
There is a fuel leak in bow thruster fuel piping by the tank. Epoxy installed has to be removed and fuel leak corrected.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2018
Resolved 10 December 2018
Resolution: Onsite Checked, Sat
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 November 2018
Resolved
Fire control boundaries must be so insulated with approved structural insulation, bulkhead panels, or deck coverings.
Bow thruster space the A-60 insulation by the hatch has improper repair with unapproved materials
E/R port side underside of stair case by the vent the A-60 insulation is missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2018
Resolved 10 December 2018
Resolution: Onsite checked, Sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 November 2018
Resolved
Cable and wiring be installed with metal supports spaced not more than 24inch apart, in such a manner to avoid chafing and other damage.
Through out vessel wire supports are missing, worn or improperly installed. Plastic wire tie wraps are being used in lieu of the metal supports. Main areas of focus should be Thruster room and E/R.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2018
Resolved 10 December 2018
Resolution: Onsite checked, sat
Communications › Radio Communications › VHF Radiotelephone
Issued 19 December 2017
Resolved
Provide a VHF Marine Radio that is properly Programmed with the vessel’s MMSI number and interfaces with the vessel’s GPS to provide an accurate position in accordance with 47 CFR 80.905(a)(1) prior to January 19, 2018 and to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 24 January 2018
Resolution: Onsite verification SAT
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 December 2017
Resolved
During a test of the vessel’s bilge high level alarms, the crew had to manipulate the alarm to get it to sound. Some of the alarms continue to sound after the crew reset the. Prior to January 19, 2018, demonstrate the proper operation and dependability of the bilge high level alarms in all spaces in accordance with 46 CFR 119.530 and to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 24 January 2018
Resolution: Onsite verification SAT, ER bilge alarm has instant visual and built in delay for audible.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 19 December 2017
Resolved
Observed a fuel leak on the fuel supply line leading to the bow thruster. Prior to carrying passengers, make permanent repairs to the leaking pipe in accordance with 46 CFR 119.455 to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 20 December 2017
Resolution: Fuel piping was removed and a new threaded pipe was fitted in. Tested the fuel supply system under pressure with no further leaks observed.
Engineering › Feedwater/Condensate Water System › Piping
Issued 19 December 2017
Resolved
Observed a leak and a temporary repair soft patch on the raw water intake pipe from the sea valve to the strainer in way of the bow thruster. Prior to carrying passengers, make permanent repairs to the leaking pipe in accordance with 46 CFR 119.700 to the satisfaction of an attending Coast Guard Marine Inspector.
Due 20 December 2017
Resolved 20 December 2017
Resolution: A new pipe was fitted on both sides of the strainer. Pipes were tested while bow thruster was running and no leaks were observed.
Engineering › Fuel Oil Service System › Valve
Issued 19 December 2017
Resolved
The emergency fuel shutoff valve in way of the fuel tank in the bow thruster space was broken. Prior to carrying passengers, make necessary repairs to the remote fuel shut off in accordance with 46 CFR 119.455(b)(3) to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: Repairs were made to the remote fuel shut off and crew tested the system in presence of the Marine Inspector.
Engineering › Bilge Water Management System › Not Operational
Issued 26 September 2016
Resolved
The high level alarm IWO the bow thruster space failed to properly operate. Prove proper operation of the bilge high level alarm to the satisfaction of the attending CG Marine Inspector. 46CFR119.530
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Resolution: Onsite Verification.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 26 September 2016
Resolved
The exhaust pipe IWO the lazarette space has approx. 5 in. crack at the weld seam causing a leak of exhaust gas into the space. Prove proper repair of exhaust piping to the satisfaction of the the attending CG Marine Inspector. 46CFR119.430(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Resolution: Onsite Verification.
Engineering › Bilge Water Management System › Strainer
Issued 26 September 2016
Resolved
The bilge suction IWO of the HVAC compartment does not have a strainer fitted (flex hose connected to the end of the pipe). Provide proper installation of the a strainer to the satisfaction of the attending CG Marine Inspector.
46CFR119.510; 46CFR56.50-50(g)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Resolution: Onsite Verification.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 September 2016
Resolved
Excessive oil was found IWO the lazarette and engine room space that prevented the testing of the bilge suctions. Remove excessive oil and prove proper operation of bilge suctions in the two aforementioned spaces to the satisfaction of the attending CG Marine Inspector. 46CFR115.820(b), 46CFR119.520
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Resolution: Onsite Verification.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 September 2016
Resolved
Electrical box IWO the lazarette has been secured with plastic zip ties. Provide proper installation of the electrical box IWO the lazarette to the satisfaction of the attending CG Marine Inspector.46CFR120.220(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Lifesaving › Lifefloat › Serviceable
Issued 26 September 2016
Resolved
The lifefloats installed on the vessel have numerous items that require attention such as faded retro reflective tape, webbing for grablines worn/torn, missing paddles, paddles w/o names, repairs with the foam,mark with vessel. 46CFR117.175(f)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Resolution: Onsite Verification.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 26 September 2016
Resolved
The electrical panel IWO of the galley space are not marked for the spaces/equipment being utilized. Prove proper labeling of circuit breakers in the galley electrical panel to the satisfaction of the attending CG Marine Inspector.
46CFR120.220(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Lifesaving › Rescue Boat › Markings
Issued 26 September 2016
Resolved
The rescue markings are worn off. Prove proper markings of the rescue boat to the satisfaction of the attending CG Marine Inspector. 46CFR122.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 26 September 2016
Resolved
Two (2) light fixtures IWO the bow thruster space does not have suitable guards. Provide proper installation of lens guard to the lights in the bow thruster space to the satisfaction of the attending CG Marine Inspector. 46CFR120.410(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Resolution: Onsite Verification.
Engineering › Compressed Air System (start air) › Valve
Issued 26 September 2016
Resolved
The safety relief valve was found inoperable. Prove proper operation of the safety relief valve to the satisfaction of the attending CG Marine Inspector. 46CFR115.812, 46CFR61.10-5(i)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Resolution: Onsite Verification.
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 26 September 2016
Resolved
Oil level in the containment has reached the drainage hole for the containment area. Prove proper disposal/cleanup of the containment space to the satisfaction of the attending CG Marine Inspector. 46CFR115.830(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Resolution: Onsite Verification.
Navigation › Piloting/Steering › Magnetic Compass
Issued 26 September 2016
Resolved
Vessel does not have a magnetic compass installed; vessel had the required compass installed when it was delivered to Sector Miami's AOR in NOV 1998. Prove proper installation of marine type magnetic compass with proper illumination to the satisfaction of the attending CG Marine Inspector. 46CFR121.402
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Resolution: Onsite Verification.
Construction/Loadline › Structures › Manhole
Issued 26 September 2016
Resolved
Hatch exposed to the weather must be watertight. The hatch knife edge (cover & deck) IWO the lazarette is worn. Provide gasket for the hatch ensuring watertight integrity is met to the satisfaction of the attending CG Marine Inspector. 464CFR116.1160
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Resolution: Onsite Verification.
Engineering › Bilge Water Management System › Not Operational
Issued 26 September 2016
Resolved
The high level alarm IWO the lazarette space failed to properly operate. Prove proper operation of the bilge high level alarm to the satisfaction of the attending CG Marine Inspector. 46CFR119.530
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2016
Resolved 1 November 2016
Resolution: Onsite Verification.
Engineering › Steering Gear System › Ram
Issued 13 June 2016
Resolved
Provide a specification sheet (cut sheet) for the new hydraulic rams and associated parts in way of the steering gear Upon Coast Guard approval of the material and installation on board, demonstrate the effectiveness of the steering system during underway sea trials prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 17 June 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 June 2016
Resolved
Remove all damaged wiring for the lighting system and the rescue boat winch and replace with UL approved marine grade, copper strand wiring to the satisfaction of an attending Coast Guard Marine Inspector. In addition, provide a cut sheet with the wiring to be used to ensure compliance with 46 CFR 120.340.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 17 June 2016
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 June 2016
Resolved
Remove all damaged wiring for the lighting system and the rescue boat winch and replace with UL approved marine grade, copper strand wiring to the satisfaction of an attending Coast Guard Marine Inspector. In addition, provide a cut sheet with the wiring to be used to ensure compliance with 46 CFR 120.340.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 17 June 2016
Engineering › Steering Gear System › Hydraulic Hose
Issued 13 June 2016
Resolved
Remove all damaged wiring for the lighting system and the rescue boat winch and replace with UL approved marine grade, copper strand wiring to the satisfaction of an attending Coast Guard Marine Inspector. In addition, provide a cut sheet with the wiring to be used to ensure compliance with 46 CFR 120.340.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 17 June 2016
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 13 June 2016
Resolved
Remove and replace all oil soaked and/or damged lagging in way of the exhaust piping in the lazarette to the satisfaction of an attending Coast Guaard Marine Inspector. In addition, ensure all exposed sections/area on the dry exhaust pipes that penetrate the space are suitably protected with sufficient lagging material.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 17 June 2016
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 June 2016
Resolved
Remove all released/spilled hydraulic oil that accumulated in the forward bilge of the lazarette as a result of the seal failure in the steering gear system to the satisfaction of an attending Coast Guard Marine Inspector. In addition, ensure the recovered product is properly disposed of.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 17 June 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 June 2016
Resolved
Crop and Renew wasted section of the sea water supply piping located in the forward lazarette to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 17 June 2016
Construction/Loadline › Structures › Deck Plating
Issued 13 June 2016
Resolved
Submit a repair proposal for the holed section of the overhead in the lazarette which penetrates into the CO2 storage space on the deck above.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 17 June 2016
Construction/Loadline › Structures › Scuttle
Issued 13 June 2016
Resolved
Make proper repairs and demonstrate watertight integrity of two (02) hatches on the aft deck in way of the lazarette. At a minimum, the gasket material needs to be replaced and the dogging devices renewed to ensure the hatches provide a watertight seal.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 17 June 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 13 June 2016
Resolved
Provide servicing for a total of five (05) portable fire extinguishers that were discharged while the crew attempted to extinguish the fire in the lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 17 June 2016
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 13 June 2016
Resolved
Owner, Operator and Master are reminded that any repairs or alterations to the hull, machinery or equipment on an inspected passenger vessel must be made only with prior approval of the Coast Guard.
Due 14 June 2016
Resolved 13 June 2016
Resolution: Deficiency was recorded to ensure the Owner, Operator and Master are aware of their responsibilities to obtain prior approval from the OCMI.
Accommodation/Occupational Safety › Ventilation › General
Issued 12 February 2016
Resolved
Ensure all ventilation louvers close upon power loss for the main casino deck and the 01 casino deck. 12 total ventilation closures, 6 on each side.
Action required: 705 - Other - as specified
Resolved 21 April 2016
Resolution: Corrected.
Engineering › Bilge Water Management System › Not Operational
Issued 14 December 2015
Resolved
Prove proper operation of bilge pump to take suction from #1 void, bow thruster room and engine room.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Engineering › Bilge Water Management System › Strainer
Issued 14 December 2015
Resolved
Properly install bilge strainers on all bilge suction lines where missing.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 December 2015
Resolved
Properly repair emergency fuel shutdown in engine room.
Action required: 705 - Other - as specified
Due 14 December 2015
Resolved 25 January 2016
Resolution: Corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 14 December 2015
Resolved
Re-attach (weld) CO2 line in bow thruster room that broke away from bracket.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 14 December 2015
Resolved
Properly adjust and prove proper operation of engine room and 02 deck stern air handler room ventilation closures.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Construction/Loadline › Hull › Weld
Issued 14 December 2015
Resolved
Submit proposal to properly repair wasted/holed deck in main deck air handler space.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 27 April 2016
Documentation › Markings/Placards › Warning Signs
Issued 14 December 2015
Resolved
Properly mark engine room "Emergency Exit Keep Closed" on maindeck.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 December 2015
Resolved
Clean stern light lens.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 14 December 2015
Resolved
Properly remove and clean oil in engine room bilge.
Action required: 705 - Other - as specified
Due 28 December 2015
Resolved 25 January 2016
Resolution: Corrected.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 14 December 2015
Resolved
Replace both main engine raw water cooling hoses for transmission.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Construction/Loadline › Structures › Ventilators
Issued 14 December 2015
Resolved
Properly repair lazarette ventilation goose neck that is wasted/holed.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Engineering › Fuel Oil Service System › Hose
Issued 14 December 2015
Resolved
Renew No. 2 generator fuel hose that has a screwhead indent (replace with SAE- J1942 hose)
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 December 2015
Resolved
Properly repair and prove proper operation of all inop emergency lights.
Action required: 705 - Other - as specified
Due 28 December 2015
Resolved 25 January 2016
Resolution: Corrected.
Fire Fighting › Ventilation Systems › Fans
Issued 14 December 2015
Resolved
Renew screen for galley exhaust ventilation fan.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Construction/Loadline › Penetrations › Pipe Flange
Issued 14 December 2015
Resolved
Repair/replace wasted drain pipe in engine room port side ventilation duct.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Construction/Loadline › Penetrations › Pipe Flange
Issued 14 December 2015
Resolved
Properly repair bow thruster raw water overboard piping (pin hole leak).
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Engineering › Pressure Vessel › Foundation
Issued 14 December 2015
Resolved
Make available for internal inspection engine room pressure vessels (air tank).
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 18 April 2016
Resolution: Inspected sat with borescope.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 December 2015
Resolved
Properly renew or repair electrical junction box on bow.
Action required: 705 - Other - as specified
Due 13 January 2016
Resolved 25 January 2016
Resolution: Corrected.
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 27 January 2012
Resolved
Port generator exhaust collecter wasted; resleeved and tested sat.
Condition: Improper/Lack of Maintenance
Due 27 January 2012
Resolved 27 January 2012
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 September 2011
Resolved
Remove wire splice prior to outlet box in way of the steam table on the third deck. Make proper connections inside box.
Condition: Improper Installation
Due 5 October 2011
Resolved 5 October 2011
Electrical › Electrical Distribution System (service) › Switch
Issued 15 September 2011
Resolved
Properly fasten the thermostatic switch that is loose inside the exhaust fan cowling located in the galley bulkhead aft of the ovens.
Condition: Improper/Lack of Maintenance
Due 5 October 2011
Resolved 5 October 2011
Electrical › Electrical Distribution System (service) › Switch
Issued 15 September 2011
Resolved
Hard wire a switch using appropriate marine grade cable to the galley exhaust fan above the convection oven. Currently a plug is being used to turn it on and off.
Condition: Improper Installation
Due 5 October 2011
Resolved 5 October 2011
Electrical › Electric Supply System (service) › Cable
Issued 15 September 2011
Resolved
Remove extension cord from cold box (refrigerator) located in the galley port side. use a direct connection to the outlet or hard wire.
Condition: Improper Installation
Due 5 October 2011
Resolved 5 October 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 September 2011
Resolved
Provide safety latches for the convection oven doors.
Condition: Placed in Improper Service
Due 5 October 2011
Resolved 5 October 2011
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 September 2011
Resolved
Insure outlets and junction boxes are properly secured in the slot machine bases.
Condition: Improper Installation
Due 29 October 2011
Resolved 3 December 2012
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 September 2011
Resolved
Ensure Uninterupted power supllies (UPS) in the bases of the slot machines are secured. Remove surge protection for UPSs if surge protection is built in to the unit
Condition: Improper Installation
Due 5 October 2011
Resolved 3 December 2012
Electrical › Lighting (service) › Conductor
Issued 15 September 2011
Resolved
Remove loose gear from under the control station in the wheel house. e.g. spool of electrical cable and spool of line.
Due 5 November 2011
Resolved 5 October 2011
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 15 September 2011
Resolved
Renew Life jacket boxes on second deck with boxes that will prevent the life jackets from being in direct contact with the carpet .
Additionally redistribute Life jackets and annotate safety plan as discussed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 October 2011
Resolved 3 December 2012
Construction/Loadline › Penetrations › Gasket
Issued 15 September 2011
Resolved
Install Gland gasket in the stuffing tube in way of the engine room escape and the air handing room located aft port side of the main deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 October 2011
Resolved 5 October 2011
Construction/Loadline › Penetrations › Gasket
Issued 15 September 2011
Resolved
Repair Cable Penetration starboard side forward BHD in the engine room. (Roxtec?)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 October 2011
Resolved 3 December 2012
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 September 2011
Resolved
Ensure raw water line hoses are double clamped at both ends.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 3 December 2012
Engineering › Bilge Water Management System › Pump
Issued 15 September 2011
Resolved
Test Bilge Pump in the presence of a marine inspector.
Action required: 705 - Other - as specified
Due 5 October 2011
Resolved 5 October 2011
Fire Fighting › Fire Pumps › Pressure
Issued 15 September 2011
Resolved
Test Fire pump in the presence of a marine inspector.
Action required: 705 - Other - as specified
Due 5 October 2011
Resolved 5 October 2011
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 15 September 2011
Resolved
Renew damaged and missing fire insullation in way of the intake vent damper in kind.
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 18 December 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 September 2011
Resolved
Renew the water light on the bridge ring buoy.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 October 2011
Resolved 5 October 2011
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 15 September 2011
Resolved
Re map addressable components of the Intelleknight fire detection panel to indicate location of component or zone covered.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2011
Resolved 18 December 2014
Construction/Loadline › Penetrations › Pipe Flange
Issued 15 September 2011
Resolved
Renew Deck Penetration for camera wires to engine room located in main deck port air handler room.
stuffing tube/pipe to be a minimum of 12 inches high, welded on bot side of the penetration sfp insulation installed and fire stop.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2011
Resolved 3 December 2012
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 September 2011
Resolved
Increase the length of hose on the aft generator raw water intake and double clamp the same.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2011
Resolved 30 April 2013
Engineering › Bilge Water Management System › Interface Detector
Issued 20 January 2011
Resolved
Reinstall Bilge level alarms, i.e. Water bugs, with proper wiring techniques and affixing the detector to a sound structure vice allowing them to hang on the signal wire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 February 2011
Resolved 3 December 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 20 January 2011
Resolved
Renew starboard main diesel engines lube oil line. (leaking)
Due 20 February 2011
Resolved 3 December 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 January 2011
Resolved
Repair and reinstall the flywheel guard on the port generator .
Condition: Improper/Lack of Maintenance
Due 20 February 2011
Resolved 3 December 2012
Engineering › Fuel Oil Service System › Valve
Issued 20 January 2011
Resolved
Renew/repair the fuel oil cut off valve so that it does not pass the fully closed position when it is remotely closed.
Due 20 February 2011
Resolved 18 December 2014
Construction/Loadline › Penetrations › Pipe Flange
Issued 20 January 2011
Resolved
Renew the through hull fire main overboard penetration on the port side engine room. Piping to be not less than schedule 80
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2011
Resolved 3 December 2012
Engineering › Bilge Water Management System › Piping
Issued 20 January 2011
Resolved
Remove soft patch on bilge line in way of the bilge manifold. Make permanent repairs to the same.
Condition: Improper/Lack of Maintenance
Due 20 February 2011
Resolved 3 December 2012
Engineering › Bilge Water Management System › Strainer
Issued 20 January 2011
Resolved
Replace bilge strainers on bilge lines. the aggregate area of openings in strainers must be equivalent to three times the area of the sanction area.
Condition: Placed in Improper Service
Due 20 February 2011
Resolved 3 December 2012
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 20 January 2011
Resolved
Gauge - Unknown Cause/Condition
Due 11 February 2011
Resolved 11 February 2011
Engineering › Fuel Oil Service System › Gauge
Issued 20 January 2011
Resolved
Provide self closing valves on the fuel tank gauge glasses at next dry dock availability. Until these valves are replaced apply a sign to the tank requiring valves to be closed except when gauging or filling tank.
Condition: Improper Installation
Due 31 December 2012
Resolved 18 December 2014
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 January 2010
Resolved
Renew/Repair inoperable emergency light fixture in the refridgeration compressor compartment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2010
Resolved 9 February 2010
Electrical › Electrical Distribution System (service) › Cable
Issued 4 January 2010
Resolved
Refasten electrical wire currently made fast to other cables vice appropriate supports through out the refrigeration compressor room using good marine practice.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 February 2010
Resolved 4 January 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 January 2010
Resolved
Arrange for a marine inspector to attend the servicing and testing of the fixed CO2 at next service interval. Currently due on or aboout 22 January 2010.
Action required: 705 - Other - as specified
Resolved 9 February 2010
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 January 2010
Resolved
Provide for the storage and availabilty of 75 to 100 life jackets on the main deck (a primary refuge area).
Action required: 705 - Other - as specified
Due 15 February 2010
Resolved 9 February 2010
Engineering › Pressure Vessel › Shell Plate
Issued 4 January 2010
Resolved
Make service air pressure vessel available for internal exam by USCG inspector.
Action required: 705 - Other - as specified
Due 15 February 2010
Resolved 9 February 2010
Documentation › Certificates/Documents › FCC SSL
Issued 9 January 2008
Resolved
Provide a Comunications Act Safety Certificate.
Action required: 705 - Other - as specified
Resolved 4 January 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 3 December 2007
Resolved
Ensure release of bow thruster compartment CO2 flooding system shuts down the bow thruster prime mover and mechanical ventilation.
Condition: Improper Installation
Due 15 December 2007
Resolved 14 December 2007
Resolution: Tested Satisfactorily
Fire Fighting › Fixed Fire Detection System › Approval
Issued 3 December 2007
Resolved
Provide proof that Silent Knight 5808 Fire detection system, associated sensors and appurtenances are a USCG approved installation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 14 November 2014
Resolution: Old Def, closed.
Electrical › Electric Generation Source (service) › Panelboard
Issued 3 December 2007
Resolved
Repair/renew Woodward generator Monitoring system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 20 January 2011
Resolution: Rescinded, Company no longer has monitor receiving equipment.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 November 2007
Resolved
Renew/Repair light fixture located on the port side vent stack
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2007
Resolved 14 December 2007
Resolution: Noted renewed light fixture.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 27 November 2007
Resolved
Ensure all receptacles located under the third deck service bar are permanently fastened, properly enclosed and not over loaded.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 December 2007
Resolved 14 December 2007
Resolution: Noted proper installation
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 27 November 2007
Resolved
Provide proof that small waste receptacles in the salon are of non-combustable material.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 December 2007
Resolved 5 December 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 27 November 2007
Resolved
Provide wiring schematic or instructions for CO2 shutdowns for the Main Diesel Engines and the Main Diesel Generators
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 3 December 2007
Resolution: Engine shut downs reconnected.
Engineering › Fuel Oil Service System › Valve, Control
Issued 27 November 2007
Resolved
Repair/renew reset circut on starboard Main diesel for CO2 shut down.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 December 2007
Resolved 14 December 2007
Construction/Loadline › Hull › Hull Plating
Issued 18 July 2007
Resolved
The bow is holed approximately 10 inch X 10 inch about three (3) foot above the water line right where the keel runs. The damage was caused by a collision with a pontoon for a dredge pipe. This keel is also tripped and broke from its welds along the bottom plate which will require cropping and renewing. A temporary concrete patch shall be placed over the holed area prior to the vessel leaving.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2007
Resolved 19 July 2007
Resolution: A temporary cement patch has been placed over area and the vessel will travel to Jacksonville, FL for permanent repairs.
Construction/Loadline › Hull › Keel
Issued 18 July 2007
Resolved
Permanent repairs will need to be completed iwo the holed area and damaged keel. This area will need to be cropped and renewed.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2007
Resolved 25 July 2007
Resolution: Satisfactory weld examination and Hose test completed
Engineering › Compressed Air System (control) › Piping
Issued 4 January 2007
Resolved
Air hose installed in service air system runs from engine room to forward bow thurster compartment is not of approved type. Remove and replace with approved hose according to 46 CFR 56.60.25 or metal piping as per 46 CFR 119.730.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 February 2007
Resolved 3 December 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 4 January 2007
Resolved
Light fixtures in lazarette are missing globes and guards, install proper globes and guards.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 February 2007
Resolved 3 December 2007
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 5 October 2006
Resolved
Test all engine alarms at next dry dock.
Action required: 705 - Other - as specified
Due 30 January 2007
Resolved 3 December 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 5 October 2006
Resolved
Have current tide/tidal current tables onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2006
Resolved 15 December 2006
Fire Fighting › Nozzles › Type
Issued 5 October 2006
Resolved
Provide spanner wrenches at all fire stations.
Due 1 December 2006
Resolved 15 December 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 October 2006
Resolved
Repair/Renew outlet box in main deck bar over sink
Action required: 705 - Other - as specified
Due 15 December 2006
Resolved 15 December 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 October 2006
Resolved
Remove power strip in main deck bar area, make outlets permanent.
Action required: 705 - Other - as specified
Due 1 December 2006
Resolved 15 December 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 October 2006
Resolved
Properly mount outlet in 2nd deck bar area.
Action required: 705 - Other - as specified
Due 1 December 2006
Resolved 15 December 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 October 2006
Resolved
Renew cable for port engine room fuel shutdown.
Action required: 705 - Other - as specified
Due 1 December 2006
Resolved 15 December 2006
Engineering › Bilge Water Management System › Manifold
Issued 5 October 2006
Resolved
Install check valves in bilge system manifold.
Action required: 705 - Other - as specified
Due 1 December 2006
Resolved 15 December 2006
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 5 October 2006
Resolved
Tighten/re-pack starboard stuffing box for propulsion shaft.
Action required: 705 - Other - as specified
Due 15 December 2006
Resolved 15 December 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 September 2005
Resolved
Relocate emergency Fuel oil shut off pull stations outside Machinery space and Bow thruster space.
Condition: Improper Installation
Due 22 October 2005
Resolved 7 February 2006
Resolution: Fuel oil shut offs have been satisfactorily rerouted.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 21 September 2005
Resolved
Resize Anchor and ground tackle for appropriate size vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 January 2007
Resolved 4 January 2010
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 21 September 2005
Resolved
Ensure all ventilation dampers are operational on all decks.
Condition: Improper/Lack of Maintenance
Due 22 October 2005
Resolved 7 February 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 September 2005
Resolved
Reassess location and storage of lifejackets.
Condition: Design Flaw
Due 22 October 2005
Resolved 6 July 2006
Resolution: A total of 236 life jackets have been relocated to the second deck (safe refuge area) from the original location on the aft deck.
Operations/Management › Passenger Operations › Safety Orientation
Issued 21 September 2005
Resolved
Resubmit the following to MSC: Evacuation plan to include safe refuge area, location of Fuel Shut off valves and relocation of life jackets.
Condition: Unknown
Due 22 October 2005
Resolved 6 July 2006
Resolution: Completed safety plan verification and found it accurate.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 21 September 2005
Resolved
Provide annual service report for Fire Detection System.
Condition: Unknown
Due 22 October 2005
Resolved 7 February 2006
Resolution: New system installed.
Lifesaving › Lifefloat › Markings
Issued 15 October 2004
Resolved
Non Type II 164.018 approved retroreflective tape found in some lifefloats. Replace tape with approved Type II retroreflective tape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 November 2004
Resolved 16 November 2004
Communications › Alarms/Indicators › General Alarm
Issued 15 October 2004
Resolved
Public Address system found inoperatrive in 3rd deck. Make proper repairs to attest proper operation of the system.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 November 2004
Resolved 16 November 2004
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 15 October 2004
Resolved
While starting the motor it was noted that it took six attempts to get it started and while underway the motor stopped and restarted again. Make proper to reflect proper starting system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2004
Resolved 16 November 2004
Lifesaving › Rescue Boat › Markings
Issued 15 October 2004
Resolved
Non Type II 164.018 approved retroreflective tape found in rescue boat. Replace tape with approved Type II retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2004
Resolved 16 November 2004
Lifesaving › Rescue Boat Equipment › Buoyant Line
Issued 15 October 2004
Resolved
Found hand rope grablines worned. Replace lines with new ones.
Action required: 705 - Other - as specified
Due 15 November 2004
Resolved 16 November 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 15 October 2004
Resolved
Provide correct/actual circuit breaker legends at L9 and L8.
Action required: 705 - Other - as specified
Due 15 November 2004
Resolved 16 November 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 October 2004
Resolved
Provide one tourniquet for the First-Aid kit.
Action required: 705 - Other - as specified
Due 15 November 2004
Resolved 16 November 2004
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 October 2004
Resolved
Found Fire doors 1) Stbd side between stairs and bridge and 2) Aft of 3rd deck iwo galley not self-closing properly. Make proper adjustment on doors so they can self-close properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2004
Resolved 16 November 2004
Lifesaving › Visual Distress Signals (General) › Expired
Issued 15 October 2004
Resolved
Smoke distress signals will expire in February 2005. Replace distress signals prior to Feb 2005.
Action required: 705 - Other - as specified
Due 31 January 2005
Resolved 16 November 2004
Engineering › Bilge Water Management System › Pump
Issued 15 October 2004
Resolved
Test bilge system on each compartment for proper suction during next dry dock in November 2004.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 19 October 2004
Resolution: Completed satisfactory test.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 October 2004
Resolved
Properly instal computer cable runs in Camera Room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 November 2004
Resolved 19 November 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 October 2004
Resolved
Provide permanent repair for raw water discharge piping at chiller.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 November 2004
Resolved 11 July 2005
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 October 2004
Resolved
Properly repair A-30 fire door leading to engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2004
Resolved 11 July 2005
Fire Fighting › Fire Pumps › Impeller
Issued 15 October 2004
Resolved
Properly repair main fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2004
Resolved 22 October 2004
Fire Fighting › Fire Pumps › Arrangement
Issued 15 October 2004
Resolved
Properly attach pump motor to pump foundation (missing bolts
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 16 November 2004
Fire Fighting › Fire Pumps › Pressure
Issued 15 October 2004
Resolved
Provide a gauge with proper range of pressure graduation.
Action required: 705 - Other - as specified
Due 22 November 2004
Resolved 11 July 2005
Operations/Management › Drills/Instruction
Issued 21 October 2003
Resolved
Update fire control plan I.A.W. 46CFR 116.530
Due 28 November 2003
Resolved 20 December 2003
Electrical › Electric Supply System (service)
Issued 21 October 2003
Resolved
Remove electrical extension cables from DJ area and renew wiring I.A.W. 46CFR 120 LEGACY COMPONENT DESC: Cable
Due 18 November 2003
Resolved 15 November 2003
Personnel
Issued 21 October 2003
Resolved
Provide means for escape from walk-in freezer LEGACY COMPONENT DESC: Freezer
Due 4 November 2003
Resolved 18 November 2003
Engineering › Pressure Vessel › Relief Valve
Issued 21 October 2003
Resolved
Provide relief valve for compressed air reciever
Due 4 November 2003
Resolved 18 November 2003
Deck/Cargo
Issued 5 October 2001
Resolved
Repair leaking oil seal on bow thruster.
Condition: Unknown
Due 19 October 2001
Resolved 18 October 2001
Engineering
Issued 5 October 2001
Resolved
Permanently repair cooling leak on port main engine cooling line.
Condition: Unknown
Due 19 October 2001
Resolved 18 October 2001
Engineering
Issued 5 October 2001
Resolved
Remove/replace deteriorated exhaust lagging in aft steering; notify Coast Guard when space is ready for inspection.
Condition: Unknown
Due 5 April 2002
Resolved 8 April 2002
Lifesaving
Issued 5 October 2001
Resolved
Replace "D" rings on rescue boat hoist & level rescue boat from a slant_x001C_ angle.
Condition: Unknown
Due 19 October 2001
Resolved 18 October 2001
Fire Fighting
Issued 5 October 2001
Resolved
Provide documentation for approval of fixed fire-fighting system to ensure it meets regulatory standards.
Condition: Unknown
Due 19 October 2001
Resolved 18 October 2001
Accommodation/Occupational Safety
Issued 5 October 2001
Resolved
Provide PA speaker for second deck stariway.
Condition: Unknown
Due 19 October 2001
Resolved 18 October 2001
Engineering
Issued 5 October 2001
Resolved
Provide chaffing gear for fuel hoses in E/R as needed.
Condition: Unknown
Due 19 October 2001
Resolved 18 October 2001
Engineering
Issued 31 October 2000
Resolved
F/O Tank sightglass protective shield is missing.
Condition: Unknown
Due 16 November 2000
Resolved 17 November 2000
Engineering
Issued 29 July 2000
Resolved
Prior to getting under way effect permanent repairs to starboard engine in way of oil leak to satisfaction of the OCMI
Condition: Unknown
Due 30 July 2000
Resolved 7 August 2000
Engineering
Issued 30 May 2000
Resolved
Prior to the carriage of passengers, provide a written report from the portengineer attesting to the repairs made to #1 & #2 GENSETS.
Condition: Unknown
Due 31 May 2000
Resolved 31 May 2000
Documentation
Issued 5 October 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Lifesaving
Issued 5 October 1999
Resolved
PROVIDE 47 ADULT PFD,S. TOTAL POB ALLOWED REDUCED TO 711 UNTIL REPLACED ANDINSPECTED.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Documentation
Issued 5 October 1999
Resolved
PROVIDE A DRUG TESTING PROGRAM IAW 46 CFR PART 16.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Construction/Loadline
Issued 5 October 1999
Resolved
PROVIDE SELF PRIMING BILGE PUMPS.
Condition: Unknown
Due 5 October 1999
Resolved 5 October 1999
Accommodation/Occupational Safety
Issued 7 May 1999
Resolved
Prior to 07 JUN 99, provide a Public Address System IAW 46CFR184.610(b).
Condition: Unknown
Due 7 May 1999
Resolved 7 May 1999
Fire Fighting
Issued 28 April 1999
Resolved
Prior to the carriage of passengers, prove proper operation of the fixed fire extinguishing shut down system.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Engineering
Issued 17 February 1999
Resolved
PROVIDE A REPAIR REPORT FROM TECHNICAL REPRESENTATIVE AND PROVE PROPER OPERATION OF ENGINE TO A USCG MARINE INSPECTOR.
Condition: Unknown
Due 17 March 1999
Resolved 5 March 1999
Navigation
Issued 5 November 1998
Resolved
Provide approved rudder design from CG Marine Safety Center, welding procedures and welders quals prior to rudder fabrication/installation. Upon installation prove proper operation of all steering equipment through a dynamic underway test.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Deck/Cargo
Issued 5 November 1998
Resolved
Provide adequate anchor and chain prior to the carriage of passengers.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Navigation
Issued 5 November 1998
Resolved
DISASSEMBLE AND PRESENT FOR INSPECTION RUDDER POST/STOCK PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Documentation
Issued 5 November 1998
Resolved
Provide FCC Safety Certificate.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Lifesaving
Issued 5 November 1998
Resolved
Provide safety railings around walkways located in ac space.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Deck/Cargo
Issued 5 November 1998
Resolved
Submit proposal to eliminate anchor chain hang up and anchor line chaffingon anchor hawser.
Condition: Unknown
Due 12 November 1998
Resolved 16 November 1998
Fire Fighting
Issued 5 November 1998
Resolved
Prove proper operation of the fixed CO2 system IAW 46 CFR 118.410 prior to the carriage of passengers.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Navigation
Issued 5 November 1998
Resolved
Provide suitable magnetic compass IAW 46 CFR 121.402.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Fire Fighting
Issued 5 November 1998
Resolved
Make valve leading to fire main pressure gauge near fire pump fully operational.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Engineering
Issued 5 November 1998
Resolved
Prove proper operation of emergency stop to MDE's prior to the carriage of passengers.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Deck/Cargo
Issued 5 November 1998
Resolved
Properly secure to bulkhead all refrigerators located in bartenders stations prior to the carriage of passengers._x001C_
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Electrical
Issued 5 November 1998
Resolved
Provide electrical matting around control panel in the engine room.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Lifesaving
Issued 5 November 1998
Resolved
Provide safety hand railing on ladder and around upper deck leading into engine room.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Electrical
Issued 5 November 1998
Resolved
Remove/replace all plastic wire tie supports in engine room per_x001C_ 46CFR120.340.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Lifesaving
Issued 5 November 1998
Resolved
Provide retroreflective tape on life rings prior to the carriage of passengers.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Electrical
Issued 5 November 1998
Resolved
Remove all deadend wiring.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Lifesaving
Issued 5 November 1998
Resolved
Remove all excess flammable liquids (5 gal containers) in engine room priorto the carriage of passengers.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Electrical
Issued 5 November 1998
Resolved
Mount two broken light fixtures, and check/secure all remaining light_x001C_ fixture in engine room.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Engineering
Issued 5 November 1998
Resolved
Provide tech report addressing cooling and oil pressure issues on both P/S MDE.
Condition: Unknown
Due 5 November 1998
Resolved 8 November 1998
Deck/Cargo
Issued 5 November 1998
Resolved
Provide means of quick disconnecting bow anchor by ways of pelican hook arrangement.
Condition: Unknown
Due 12 November 1998
Resolved 16 November 1998
Construction/Loadline
Issued 5 November 1998
Resolved
Provide locking mechanism's on all doors leading outside prior to the carriage of passengers.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Lifesaving
Issued 5 November 1998
Resolved
Provide light for each lifefloat, proper sized weak link and sea painter, and properly stencil both sides of lifefloat.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Lifesaving
Issued 5 November 1998
Resolved
Remove/relabel #'s on lifefloats.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Electrical
Issued 5 November 1998
Resolved
Provide guard around switches within HVAC electrical panel in Engine Room.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Accommodation/Occupational Safety
Issued 5 November 1998
Resolved
Remove equipment blocking emergency exits and label emergency exits in engine room and AC space prior to the carriage of passengers.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Lifesaving
Issued 5 November 1998
Resolved
Provide paded guards that are readily noticeable around guy wire supports to top deck nav light pole prior to the carriage of passengers..
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Engineering
Issued 5 November 1998
Resolved
Inspect exhaust system in lazerette space for exhaust leak IAW 46 CFR 119.430.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Electrical
Issued 5 November 1998
Resolved
Secure all gauges/meters/indicators on bridge console.
Condition: Unknown
Due 5 November 1998
Resolved 5 November 1998
Documentation
Issued 5 October 1998
Resolved
PERMANENTLY POST STABILITY AS REQ'D BY 46 CFR 115.306 PRIOR TO THE CARRIAGEOF PASSENGERS.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Fire Fighting
Issued 5 October 1998
Resolved
PROVIDE BOLTED COVERS FOR 7 ALUMINUM VENTILATION LOUVER FRAMES ON THE 4TH DECK A/C ENCLOSURES AS REQ'D BY 46 CFR 116.610(d).
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Documentation
Issued 5 October 1998
Resolved
RESUBMIT CORRECTED NAVIGATION LIGHT AND FIRE SAFETY PLAN DIAGRAMS TO [name withheld] AND FINAL APPROVAL.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Electrical
Issued 5 October 1998
Resolved
PERMANENTLY MARK ALL MOTOR CONTROLLERS AND IDENTIFY ALL BREAKER PANEL CIRCUITS INSIDE PANEL DOORS AS REQ'D BY 46 CFR 120.220.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Lifesaving
Issued 5 October 1998
Resolved
PROVE PROPER OPERATION OF THE 4 EMBARKATION STATON ILLUMINATION LIGHTS AS REQ'D BY 46 CFR 116.510(b)(3) PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Lifesaving
Issued 5 October 1998
Resolved
ATTACH 6 LIFE FLOAT WATERLIGHTS TO LIFE FLOATS WITH 18 FT LINES AS REQ'D BY46 CFR 117.175(f)(4) PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Lifesaving
Issued 5 October 1998
Resolved
PROVIDE MANUAL WINCH ON THE RESCUE BOAT DAVIT.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Lifesaving
Issued 5 October 1998
Resolved
PROPERLY STENCIL EACH RING BUOY, PROVIDE ONE WITH A 60' LIFELINE AND ATTACHA WATERLIGHT TO ONE WITH A 3' - 6' LINE AS REQUIRED BY 46 CFR 117.70 PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Fire Fighting
Issued 5 October 1998
Resolved
INSTALL USCG APPROVED FIRE STOP MATERIAL IN THE FOLLOWING 3 WIRING COLLARS:(1) 1 COLLAR MAIN DK PORT SIDE FORWARD BLKHD 10_x001C_ (2) 2 COLLARS 3RD DK FORWARD BLKHD 36_x001C_ INSTALLATION SHALL BE ACCOMPLISHED PRIOR TO THE CARRIAGE OF PASSENGERS._x001C_
Condition: Unknown
Due 16 October 1998
Resolved 6 October 1998
Lifesaving
Issued 5 October 1998
Resolved
PROPERLY MARK PFD STOWAGE AREAS AS REQ'D BY 46 CFR 122.604 AND POST PFD PLACARDS AS REQ'D BY 46 CFR 122.516 PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Fire Fighting
Issued 5 October 1998
Resolved
MOTORIZE STARBOARD ENGINE ROOM SUPPLY VENT LOUVERS TO CLOSE UPON CO2 ACTIVATION, BRIDGE VENT REMOTE SHUT-DOWN OR LOSS OF POWER AS REQ'D BY _x001C_ 46 CFR 119.465(h) & 116.610(d).
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Documentation
Issued 5 October 1998
Resolved
PROVIDE CREW TRAINING LOG, PASSENGER ORIENTATION VIA SUITABLE PUBLIC ANNOUNCEMENTS, POSTED EMERGENCY INSTRUCTIONS, POSTED STATION BILL, DRILL LOGS, WASTE MANAGEMENT PLAN AND POSTED FIRE CONTROL PLAN PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Navigation
Issued 5 October 1998
Resolved
PROPERLY MOUNT RITCHIE ILLUMINATED COMPASS AND PROVIDE DEVIATION TABLE PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 5 October 1998
Resolved 5 October 1998
Electrical
Issued 5 October 1998
Resolved
PROVIDE PIPE CAPS ON 4 PIPE PENETRATION NIPPLES ADJACENT TO RADAR CABLE PENETRATIONS ON 4TH DK.
Condition: Unknown
Due 5 October 1998
Resolved 6 October 1998
Lifesaving
Issued 5 October 1998
Resolved
PROPERLY STENCIL VESSEL NAME & TOTAL CAPACITY ON EACH SIDE OF RESCUE BOATS BOW AS REQ'D BY 46 CFR 122.604 PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Documentation
Issued 5 October 1998
Resolved
PERMANENTLY MARK OFFICIAL NUMBER OF VESSEL ON INTERIOR OF HULL AS REQ'D BY 46 CFR 67.121 IN 3" NUMBERS/LETTERS.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Lifesaving
Issued 5 October 1998
Resolved
PROPERLY MARK 2 EMERGENCY ESCAPES MANHOLES, 2 REMOTE FUEL SHUT-OFF PULLS AND POST EMERGENCY BROADCAST INSTRUCTION ADJACENT 5T6O VHF RADIOS PRIOR TO THE CARRIAGE O PASSENGERS.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Documentation
Issued 5 October 1998
Resolved
AFFIX NOAA REGISTRATION STICKER ON 406 MHZ EPIRB UPON RECEIPT OF SAME.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Fire Fighting
Issued 5 October 1998
Resolved
PROPERLY LABEL VENTILATION FIRE DAMPERS IN MEN AND WOMEN HEADS AS REQ'D BY 46 CFR 116.610(g)(4) PRIOR TO THE CARRIAGE OF PASSENGERS._x001C_ _x001C_
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Documentation
Issued 5 October 1998
Resolved
PROVIDE DOCUMENTATION THAT THE VESSEL IS ENROLLED IN A DRUG TESTING PROGRAMPRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Lifesaving
Issued 5 October 1998
Resolved
PROVE PROPER OPERATION OF PA SYSTEM AS REQ'D BY 46 CFR 121.610 PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Documentation
Issued 5 October 1998
Resolved
PROVIDE U.S.C.G. MSC-1 APPROVED STRUCTURAL DRAWINGS TO [name withheld].
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Lifesaving
Issued 5 October 1998
Resolved
CONDUCT FIRE AND BOAT DRILLS PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998