PARAMOUNT

PARAMOUNT is a 1975 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1985, most recently in May 2026, along with 117 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1985 to 2026. Most recent: inspection, 11 May 2026.

Built
1975
Last inspected
11 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYP6419
Flag
UNITED STATES
367077580 (licence lapsed)
Maury page id
psix-48437

Inspections, by type

…with no type recorded6
…past their stated due date1
Years with a record 39 calendar years (1985–2026)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)84.7 ft × 22.5 ft × 9.9 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROBERT E. DERECKTOR, INC. · MAMARONECK, NY, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBRIELLE, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 18 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WYP6419MMSI 367077580 · expired · compulsorily equipped · granted 28 October 2015, cancelled 14 March 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 82

11 May 2026 Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8371086
7 April 2026 Deficiency Check · Administrative Inspection · Annual Inspection · Vessel Attendance
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8320077
1 April 2025 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8103545
7 March 2025 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8089880
7 January 2025 COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8057152
1 April 2024 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7887872
20 June 2023 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7719188
6 April 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7668508
13 March 2023 Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7650914
3 January 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7615735
12 May 2022 Inclining Experiment
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7454212
14 April 2022 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7431370
15 March 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7156599
13 January 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7123628
1 April 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6934570
3 January 2020 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6882075
3 October 2019 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6831456
10 May 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6681017
28 February 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6634363
3 February 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6619326
26 March 2018 Annual Inspection · DAPI Audit · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6377156
29 March 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6111111
3 March 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5826011
10 February 2016 Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5812936
6 January 2012 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4219573
1 December 2011 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4199079
20 January 2010 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3666641
9 December 2009 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3647170
8 April 2009 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3448969
26 February 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3152936
5 December 2007 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3109053
29 March 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2896635
5 January 2006 Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2560319
24 January 2005 Deficiency Check · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2279710
7 December 2004 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2255191
13 January 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1982232
10 April 2003 Periodic Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1770360
20 November 2002 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1708870
4 February 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1483850
13 February 2001 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1062788
27 January 2000 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 813938
28 January 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 789574
18 December 1998 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1429058
29 January 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1107454
6 March 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1108977
28 January 1997 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1374854
8 January 1997 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1099012
12 February 1996 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 877265
29 January 1996 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1079210
29 January 1996 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1090095
30 January 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 834677
13 January 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 827340
15 February 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1164072
1 February 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1163920
29 March 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1149791
23 February 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 839408
2 February 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 830426
16 November 1992 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1133917
17 June 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 7808
17 June 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 146356
3 June 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944900
9 March 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1260555
3 February 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1259247
19 September 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 938496
8 May 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 900018
4 February 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 909434
4 April 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223417
5 February 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 905156
5 April 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342671
7 February 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199514
19 April 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206713
23 March 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986769
8 March 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340765
29 February 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1027601
29 February 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1295874
27 October 1987 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020302
4 March 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1317698
27 June 1986 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1296963
11 March 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993268
7 March 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993263
27 March 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1293640
21 February 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1286475

Deficiency record · 117

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 April 2026 Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. COI is not posted in passenger accommodation space. 46 CFR 176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2026
Resolved 22 April 2026
Resolution: COI posted
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 April 2026 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Electrical wiring insulation is worn exposing wires on the port generator starter and starboard main engine starter. Repair/replace to satisfaction of MI. 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2026
Resolved 22 April 2026
Resolution: Electrical wiring replaced or taped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 April 2026 Resolved
Diesel engine exhaust cooling installation shall be in accordance with 182.15-15. Temporary repair (patch) found on port side main engine sea suction cooling piping. Submit repair proposal and make repairs to satisfaction of MI. 46 CFR 182.20-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2026
Resolved 19 May 2026
Resolution: Aluminum patch welded onto suction piping.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 April 2026 No resolution recorded
Have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection and operation of all weathertight closures above the weather deck and the provisions for drainage of sea water from the exposed decks. Port side window in passenger accommodation space is cracked through. Replace window to satisfaction of MI. 46 CFR 176.802
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 10 April 2026 Resolved
All ducts shall be of rigid permanent construction of fire proof material and reasonably gastight from end to end. Ducting for mechanical blowers for engine room are fitted with duct tape. Remove duct tape and repair ducts as required by MI. 46 CFR 182.45(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2026
Resolved 19 May 2026
Resolution: Duct repair sheet metal installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 April 2026 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment under all practical conditions. During testing, vessel could not satisfactorily dewater lazarette due to failed bilge pipe coupling. Repair and test bilge system to satisfaction of MI. 46 CFR 182.25-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2026
Resolution: Repaired and tested to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 April 2026 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Port side generator was disassembled for repair. Repair and demonstrate proper operation of generator to satisfaction of MI. 46 CFR 183.01-15 (a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2026
Resolution: Repaired and tested to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 April 2026 Resolved
Each survival craft on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Two of four life floats found deteriorated with broken bights for grab lines and inner basket. Replace life floats to satisfaction of MI. 46 CFR 185.700 (a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2026
Resolution: New lifefloats installed onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 January 2025 Resolved
Fire hose shall be 1.5 inches in diameter and 50 feet in length. Port side fire hose had multiple pin hole leaks at base of fire station coupling. Replace fire hose. 46 CFR 181.15-10(c) Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 13 January 2025
Resolution: Owner replaced with new hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 January 2025 Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Four bilge suction intakes in the engine room had clogged strainers. Clean strainers on main bilge suction and emergency bilge line. 46 CFR 182.25-5(b) Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 13 January 2025
Resolution: Owner cleaned strainers.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 7 January 2025 Resolved
The owner shall ensure vessel is equipped with a vessel master key control system. Vessel must have list of all crew (identified by position) allowed to access key and kept in a logbook with dates/times, rooms, and name/rank of crew member when crew utilizes master key (can be electronic, must be readily available). 46 USC 3106 Policy Letter: 23-06
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 7 March 2025
Resolution: Logs in daily captains log
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 January 2025 Resolved
Auxiliary machinery of the internal combustion piston type shall comply with the provisions of this part. Starboard main engine had temporary patch on piping feeding into jacket water expansion tank. Replace or repair piping component. 46 CFR 182.05-1(a) Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 7 March 2025
Resolution: Welded new pipe on starboard main engine heat exchanger
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 January 2025 Resolved
A battery charger intended for connection to a commercial supply voltage shall employ a transformer of the isolating type. The voltmeter gauge on the battery charger was broken. Replace gauge or battery charger installation. 46 CFR 183.05-20(f) Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 13 January 2025
Resolution: Owner replaced battery charge voltmeter.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 January 2025 Resolved
The switchboards shall be adequately protected. The operating station distribution panel had missing circuit breaker cover. Install cover or spare breaker. 46 CFR 183.05-15(a) Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 13 January 2025
Resolution: Owner placed blank circuit breaker in switchboard opening.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 April 2024 Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. The PORT side generator was inoperable. Repair to satisfaction of USCG in-person
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2024
Resolved 3 April 2024
Resolution: See description in narrative.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 1 April 2024 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. The pressure gauge at the fire pump read 40 psi consistently.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2024
Resolved 3 April 2024
Resolution: See deficiency description.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2024 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 13 adult sized life jackets had worn/deteriorated reflective material that needed to be replaced with new. Vessel's crew replaced retro-reflective material on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 April 2024
Resolved 1 April 2024
Resolution: Crew replaced retro-reflective material on 13 lifejackets on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 April 2022 Resolved
02 lifefloats were not primarily vivid reddish orange. Paint 02 discolored lifefloats and provide pictures to the USCG to rectify deficiency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2022
Resolved 6 May 2022
Resolution: Operator provided pictures attesting to the repair of life floats
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 March 2021 Resolved
Each vessel must have 1)permanent draft marks at each end of the vessel or alternatively 2)have permanent loading marks placed on each side of the vessel fwd and aft to indicate maximum allowable trim and amidships to indicate maximum allowable draft. Provide permanent Draft marks or loading Marks for the vessel.
Action required: 705 - Other - as specified
Resolved 17 April 2021
Resolution: Permanent draft marks installed and verified by Naval Architect.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2021 Resolved
AC 110V electrical panel in engine room, inboard STBD side, near entrance ladder has an unlabeled circuit (10 listed, 11 breakers in panel). Identify and label circuit on breaker panel. 46CFR183.10-10(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 22 March 2021
Resolution: Picture of 11th breaker on panel labled
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2021 Resolved
STBD engine fuel shut off is stuck in the open position, make functional. 46CFR182.20-40(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 26 January 2021
Resolution: [name withheld] was able to work the valve and it closes now.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2021 Resolved
Feed fresh water line, STBD side, passing through the forward engine room watertight bulkhead,has 3 sections of non-metallic piping (both flexible hose and PVC) fitted (1 in fwd engine room, 2 in aft boiler room). Replace these sections with original in-kind aluminum piping, alternatively fit metallic shut off valves directly connecting to bulkhead on both sides of the fwd engine room bulkhead, or one metallic valve on one side of bulkhead if it is made operable from the deck above. 46CFR182.115(b) & 46CFR182.720(e)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 14 April 2022
Resolution: During the annual inspection on 22APR2022, the condition of the forward engine room watertight bulkhead was satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 April 2020 Resolved
Structure in way of cable hangers is deteriorating; replace hangers with compatible materials or isolate hangers from structure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 20 July 2020
Resolution: Cable and associated hangers removed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 April 2020 Resolved
Provide repair proposal/mitigation plan for pitting identified under fixed ballast.
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 2 May 2020
Resolution: Area under ballast cleaned and recoated with coating system to preserve. To be checked at next annual and repaired at subsequent drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 April 2020 Resolved
Fuel sounding pipe terminates at top of fuel tank inside laz space. Filling and sounding pipes shall be so arranged that overflow of liquid or vapor cannot escape to the inside of the vessel. Sounding pipes may be omitted where sounding can be accomplished through the fill pipe or where marine type fuel gages are installed. Where sounding pipes are used, their openings shall be at least as high as the opening of the fill pipe and they shall be kept closed at all times except during sounding. Provide modification plan for meeting requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 20 July 2020
Resolution: Fuel sounding tube capped with spring loaded flapper.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 March 2020 Resolved
Provide a gauging report of the hull plate located underneath the fixed ballast in the #3 compartment. - 46 CFR 177.300
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 6 April 2020
Resolution: Area was measured with UT meter.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 January 2020 Resolved
A visual and audible bilge alarm to indicate high water in the void space must be provided at the operating station. Provide operable bilge alarm. - 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2020
Resolved 11 February 2020
Resolution: Verified with O/O via email that the issue was resolved.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 7 January 2020 Resolved
Outlets for the coffee pot and refrigerator are no longer serviceable. Replace outlets in kind. - 46 CFR 183.01-15 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2020
Resolved 11 February 2020
Resolution: O/O sent photographs of replaced outlets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 7 January 2020 Resolved
The floating water lights must be attached around the body of the life floats. Attach water lights as specified. - 46 CFR 180.175(f)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2020
Resolved 11 February 2020
Resolution: O/O sent photographs of re-attached water lights.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 January 2020 Resolved
Each life float must be individually attached to the painter by a line and long enough that each life float can float freely. Life float painter arrangement was incorrect. 46 CFR 180.137(e)(3)
Action required: 10 - Deficiency Rectified
Due 7 January 2020
Resolved 11 February 2020
Resolution: Resolved on the spot.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 January 2020 Resolved
A vessel on an oceans route is required a reserve power supply or handheld VHF radio telephone. Provide appropriate arrangement. - 46 CFR 184.25-1 (a) and 47 CFR 80.917
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2020
Resolved 11 February 2020
Resolution: Received photographs from the O/O, handheld radio placed on the vessel.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 January 2020 Resolved
Repair or reweld indicated areas in the void space at the April 2020 drydock. - 46 CFR 176.05-10
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 6 April 2020
Resolution: Welds were repaired.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 October 2019 Resolved
Required monthly EPIRB test has not been logged since the month of MAY. Conduct and record the monthly test. Present evidence of logged test to marine inspector. 46 CFR 185.728
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 6 November 2019
Resolution: Provided proof.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 October 2019 Resolved
Fire axe is being stowed in storeroom. Locate the axe in or adjacent to the operating station. 46 CFR 181.35-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 6 November 2019
Resolution: Provided proof of mounting.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 October 2019 Resolved
Vessel fire hydrants do not have spanner wrenches. Procure spanners and locate them at the fire hydrants. 46 CFR 181-310(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 6 November 2019
Resolution: Provided evidence of spanner wrenches being present.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 October 2019 Resolved
Fire hoses are not attached to the fire hydrants at all times. Hoses were stowed in storeroom. Attach hoses to hydrants to satisfaction of attending marine inspector. 46 CFR 181.15-10 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 6 November 2019
Resolution: Provided evidence of hoses being stowed in location under benches. Hoses are stowed in designated location that they were intended for.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 October 2019 Resolved
Labeling for fuel shutoff valves has become illegible. Renew labeling. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 6 November 2019
Resolution: Fuel shut off labeling has been renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2019 Resolved
Master indicated that a passenger safety orientation public announcement is not made prior to voyages. Provide to the attending marine inspector, a copy of the announcement that is to be made prior to embarking on a voyage. Hard copy is due in 14 days. Announcement to be made immediately.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 6 November 2019
Resolution: Provided proof of having a printed emergency announcement.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 June 2019 Resolved
Secure the painter line assembly for the forward two life floats onto a more sturdy platform. 46 CFR 180.130(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 4 June 2019
Resolution: Received an email from the master.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 4 June 2019 Resolved
Patch one identified life float and make orange. Limit to carrying 63 passengers until complete. 46 CFR 180.202(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 4 June 2019
Resolution: Received an email from the master with a photograph of the life float.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2019 Resolved
Cap identified dead end wires under the operating station. 46 CFR 183.200(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2019
Resolved 4 June 2019
Resolution: Received an email from the master.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 June 2019 Resolved
Provide spanner wrenches for both fire stations. 46 CFR 181.310(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2019
Resolved 9 January 2020
Resolution: Administratively closed following 2020 COI.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 June 2019 Resolved
Provide FCC Bridge to Bridge Radiotelephony certificate. 46 CFR 80.1005
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2019
Resolved 7 June 2019
Resolution: Received a photograph of the certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 May 2019 Resolved
The vessel failed to undergo an annual inspection within three months of its anniversary date. Satisfactory inspection must be completed prior to the carriage of passengers. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 May 2019 Resolved
Vessel is unable to complete the annual inspetion within the 15th month of the COI anniversary date. Owner has requested, and has been granted a deferment past the 15th month. The annual inspection must be completed no later than June 4, 2019.
Action required: 705 - Other - as specified
Due 4 June 2019
Resolved 9 January 2020
Resolution: Administratively closed after 2020 COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 May 2019 Resolved
Vessel is unable to complete the annual inspection within the 15th month of the COI anniversary date. Owner has requested, and has been granted a deferment past the 15th month. The annual inspection must be completed no later than June 4th, 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2019
Resolved 4 June 2019
Resolution: Vessel received annual inspection, COI endorsed, on 04JUN.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 February 2019 Resolved
Clad weld 02 pits as marked in starboard forepeak, near chine. More permanent repair to be made at next drydock. 46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 12 June 2019
Resolution: Received photographs from the master of the clad welds. Added special note to make permanent repairs at next dry dock.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 26 March 2018 Resolved
Strap broken on port side stuffing box; remove and replace broken strap.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 4 April 2018
Resolution: Verified install of new metallic strap.
Engineering › Fuel Oil Service System › Hose
Issued 26 March 2018 Resolved
Add chafing gear to hoses on both engines
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 4 April 2018
Resolution: Verified installation of chaffe gear on main engines.
Fire Fighting › Remote Fuel Shutoff › General
Issued 29 March 2017 Resolved
AB01: Vessel's Emergency Fuel shut off's must be marked. 46 CFR 185.608
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 19 April 2017
Resolution: [name withheld] verified in person
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 29 March 2017 Resolved
AB02: Vessel must have current/up to date charts of Area of Operation. 46 CFR 184.410
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 19 April 2017
Resolution: [name withheld] verified in person
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 29 March 2017 Resolved
AB03: Vessel must conduct general crew and supervisory drug awareness training. 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 19 April 2017
Resolution: [name withheld] verified in person
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 March 2017 Resolved
AB04: Starboard Life Ring must have vessels name on it.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 19 April 2017
Resolution: [name withheld] verified in person
Engineering › Bilge Water Management System › Piping
Issued 11 February 2016 Resolved
Replace all non-metallic material including flexible piping in bilge and fire system piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 24 March 2016
Resolution: Removed flexible piping
Fire Fighting › Fire Main › Condition
Issued 11 February 2016 Resolved
Repair or replace fire main piping in damaged area.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 24 March 2016
Resolution: Replaced piping and tested sat.
Lifesaving › Lifefloat › Painter
Issued 8 April 2009 Resolved
Lifefloat painters found tangled and knotted together. vsl owner corrected the issue on spot. He also stated that he plans to install spool devices for L/F painters to avoid any future problems. Issued CG-835 to track installation and inspection purpose. Properly arrange L/F painter IAW 46CFR180.175(f)(3)(iv) within 10 days or by 18 Apr 2009.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 16 April 2009
Resolution: Owner has arranged painters to life floats to release freely.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 26 February 2008 Resolved
Prove proper operation of STBD MDE tachometer/
Due 11 March 2008
Resolved 11 March 2008
Resolution: Owner replaced broken tach shaft at engine.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 26 February 2008 Resolved
Re-install missing lagging on port MDE exhaust.
Action required: 705 - Other - as specified
Due 11 March 2008
Resolved 11 March 2008
Resolution: Lagging observed in place as required.
Communications › Radio Communications › EPIRB
Issued 25 January 2005 Resolved
EPIRB battery past expiration date. Vsl restricted from carriage beyond 3NM.
Due 25 February 2005
Resolved 25 January 2005
Resolution: Recieved fax from Marine Safety Corp. showing satisfactory testing of EPIRB.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 January 2005 Resolved
Provide two (02) additional child life preservers for a total of eleven (11) for warm water route passenger counts. Vessel is currently restricted to carriage of 88 total for cold water.
Due 25 February 2005
Resolved 15 February 2005
Resolution: Vessel provided (02) new child life preservers.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 25 January 2005 Resolved
Provide proof of hydrostatic testing of the three (03) B-II CO2 extinguishers onboard. (1is dated 1998 and 2 are 1999)
Due 25 February 2005
Resolved 15 February 2005
Resolution: Witnessed new hydro dates on bottles and servicing report. New hydro date for CO2 bottles is 05.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 January 2005 Resolved
Provide lead lining or other suitable corrosion resistant material in Port battery box.
Due 25 February 2005
Resolved 15 February 2005
Resolution: Vessel provided suitable wood box that is fiberglass lined with 4 layers each of glass mat and epoxy.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 January 2005 Resolved
Properly secure safety guard on air compressor in engine room.
Due 25 February 2005
Resolved 15 February 2005
Resolution: Guard is properly secured.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 January 2005 Resolved
Provide adequate means of retrieving a helpless person from water in leiu of rescue boat requirement (i.e., platform at base of rescue ladder with retrieval harness).
Due 25 February 2005
Resolved 15 February 2005
Resolution: Vessel provided new rescue ladder/platform with rescue harness. Performed dockside drill for recovery, all sat.
Lifesaving
Issued 27 January 2000 Resolved
Provide second life ring to serve as primary life saving.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Lifesaving
Issued 27 January 2000 Resolved
Provide suitable emergency broadcast placard in wheelhouse IAW 46CFR184.506
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Engineering
Issued 27 January 2000 Resolved
Prove proper operation of starboard MDE RPM gauge.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Engineering
Issued 27 January 2000 Resolved
Renew Port MDE cooling water intake hose connection.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Lifesaving
Issued 27 January 2000 Resolved
Replace unservicable ring buoy located on port side aft superstructure.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Electrical
Issued 18 December 1998 Resolved
Provide metal wire retention brackets every 24 inches on the "New" wire installations, at the entrance to the engine room, in the engine room, and in the lazarette.
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Construction/Loadline
Issued 18 December 1998 Resolved
Provide strainers for the "aux" bilge suction in the engine room, both the port and the stbd side at entrance.
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Fire Fighting
Issued 18 December 1998 Resolved
Provide double clamping on the port clutched/engine driven fire pump flexible hoses located on both the intake and discharge sides of the pump.
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Construction/Loadline
Issued 18 December 1998 Resolved
Provide proper wire splices with UL marine connectors for the bilge high level alarms where float switch leads are connected.
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Electrical
Issued 18 December 1998 Resolved
Provide double clamping on the the flexible section of the coolant line forthe port generator.
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Electrical
Issued 18 December 1998 Resolved
Make repairs to stbd generator to reduce/secure the excessive oil leaks. (Fire hazard due to oil leaking/being sprayed onto exhuast manifold)
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Engineering
Issued 18 December 1998 Resolved
V & weld - cracked welds located on the top and outboard sides of both the port and the stbd exhaust, at the inboard side of the transom where the alluminum angle stringers are attached.
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Construction/Loadline
Issued 28 January 1997 Resolved
THREE RULE BILGE ALRM SWITCHES BROKEN. ROCKER COVER BROKEN OFF/REMOVED.
Condition: Unknown
Due 28 January 1997
Resolved 28 January 1997
Navigation
Issued 28 January 1997 Resolved
1990 LIGHT LIST WAS UNCORRECTED
Condition: Unknown
Due 28 January 1997
Resolved 28 January 1997
Navigation
Issued 28 January 1997 Resolved
CHARTS NOT CURRENTLY CORRECTED, CHART MISSING FOR OPERATING AREA BETWEEN EGG HARBOR AND CAPE MAY
Condition: Unknown
Due 28 January 1997
Resolved 28 January 1997
Construction/Loadline
Issued 29 January 1996 Resolved
VEE AND WELD PORT MAIN ENGINE REACH ROD GUIDE.
Condition: Unknown
Due 7 February 1996
Resolved 12 February 1996
Lifesaving
Issued 29 January 1996 Resolved
PROVIDE EMERGENCY CHECK-OFF LIST TO INCLUDE USE OF RESCUE LADDER.
Condition: Unknown
Due 7 February 1996
Resolved 12 February 1996
Construction/Loadline
Issued 29 January 1996 Resolved
VEE AND WELD CRACKS IN AFT ENGINE ROOM BULKHEAD IN VICINITY OF PORT AND STARBOARD MAIN DIESEL ENGINE EXHAUST PIPING AS MARKED.
Condition: Unknown
Due 7 February 1996
Resolved 12 February 1996
Accommodation/Occupational Safety
Issued 15 February 1994 Resolved
PROVIDE A MEANS OF SECURING OVERBORRED VALVES FROM BEING OPEN ON MSD TANKS.
Condition: Unknown
Due 25 February 1994
Resolved 25 February 1994
Engineering
Issued 15 February 1994 Resolved
REPLACE AND INSTALL FLAME SAFETY SCREEN ON FUEL VENT.
Condition: Unknown
Due 25 February 1994
Resolved 25 February 1994
Lifesaving
Issued 15 February 1994 Resolved
LIFE JACKET LOCKERS NEED TO BE MARKED CHILD/ADULT AND AMOUNT AND CHILD LIFEJACKETS SHALL BE SEPERATED FROM ADULT JACKETS.
Condition: Unknown
Due 25 February 1994
Resolved 25 February 1994
Lifesaving
Issued 15 February 1994 Resolved
LIFE RINGS NEED RETROREFLECTIVE MATERIAL AND NAME OF VESSEL ON EACH.
Condition: Unknown
Due 25 February 1994
Resolved 25 February 1994
Lifesaving
Issued 15 February 1994 Resolved
STENCIL LIFEFLOATS WITH NAME AND AMOUNT OF PEOPLE.
Condition: Unknown
Due 25 February 1994
Resolved 25 February 1994
Electrical
Issued 15 February 1994 Resolved
REPLACE BROKEN GLOBE ON EXTERIOR LIGHT ON STBD SIDE.
Condition: Unknown
Due 25 February 1994
Resolved 25 February 1994
Accommodation/Occupational Safety
Issued 1 February 1994 Resolved
PROVIDE A MEANS OF SECURING OVERBOARD VALVES FOR THE MSD TANKS._x001C_ MAKE THE OPENING OF THE VALVES A TWO STEP OPERATION.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Lifesaving
Issued 1 February 1994 Resolved
LIFE JACKET LOCKERS NEED TO BE MARKED CHILD/ADULT AND AMOUNT. SEPERATE CHILD LIFE JACKETS FROM ADULT JACKETS.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Engineering
Issued 1 February 1994 Resolved
REPLACE AND INSTALL FLAME SAFETY SCREEN ON FUEL TANK VENT.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Lifesaving
Issued 1 February 1994 Resolved
LIFE RINGS NEED RETROREFLECTIVE MATERIAL AND NAME OF VESSEL ON EACH.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Lifesaving
Issued 1 February 1994 Resolved
STENCIL LIFEFLOATS WITH NAME AND AMOUNT OF PEOPLE.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Electrical
Issued 1 February 1994 Resolved
REPLACE BROKEN GLOBE ON EXTERIOR LIGHT ON STBD SIDE.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Electrical
Issued 23 February 1993 Resolved
REINSTALL BELT GUARD ON ENGINE ROOM AIR COMPRESSOR.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Construction/Loadline
Issued 23 February 1993 Resolved
REPAIR CRACKED WELD OVER PORT EXHAUST IN AFT COMPT.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Electrical
Issued 23 February 1993 Resolved
REPAIR/REPLACE BRAIDED COVER ON WIRING TO COMPRESSOR MOTOR SO ENTIRE LENGTHOF WIRING IS PROTECTED.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Electrical
Issued 23 February 1993 Resolved
REPLACE ELECTRIC POWER CORD ON ENGINE ROOM HEATER WITH PROPERLY SHIELDED CABLE.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Construction/Loadline
Issued 23 February 1993 Resolved
REPAIR CRACKED WELDS IN 2ND COMPARTMENT - FRAMES 5-8 STBD AND PORT.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Electrical
Issued 23 February 1993 Resolved
REPAIR/REPLACE MOUNTING FOR AIR COMPRESSOR MOTOR IN ENGINE ROOM SO AS TO PREVENT ROTATION OF MOTOR.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Deck/Cargo
Issued 2 February 1993 Resolved
REPLACE HOSE FITTINGS FOR ANCHOR HYDRAULIC LINES ABOVE WEATHER DECK.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Lifesaving
Issued 2 February 1993 Resolved
PROVIDE NEW RETRO REFLECTIVE TAPE ON ALL PFD'S. OPERATION WITH PASSENGERS RESTRICTED TO DAYLIGHT OPERATIONS UNTIL THIS IS CORRECTED.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Fire Fighting
Issued 2 February 1993 Resolved
PROVIDE PRESSURE GAUGE ON PUMP OUTLET ON FIRE MAIN PUMP.
Condition: Unknown
Due 10 March 1993
Resolved 10 March 1993
Construction/Loadline
Issued 16 November 1992 Resolved
DRYDOCK EXTENSION GRANTED. MAKE VESSEL AVAILABLE FOR CREDIT DRYDOCK EXAM NO LATER THAN 31MAR93.
Condition: Unknown
Due 16 November 1992
Resolved 16 November 1992
Lifesaving
Issued 3 February 1992 Resolved
VESSEL RESTRICTED TO COASTWISE<20 UNTIL REPLACEMENT OF (2) 25-MAN L/F'S TO SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 3 February 1992
Resolved 3 February 1992
Engineering
Issued 3 February 1992 Resolved
PROVE PROPER OPERATION OF PORT MDE TACH IN WHEELHOUSE.
Condition: Unknown
Due 3 February 1992
Resolved 3 February 1992
Electrical
Issued 3 February 1992 Resolved
PLACE BLANK IN PLACE OF MISSING BREAKER IN MAIN ELECTRIC PANEL.
Condition: Unknown
Due 3 February 1992
Resolved 3 February 1992
Electrical
Issued 3 February 1992 Resolved
REPAIR BOTTOMS OF STBD SIDE BATTERY BOXES IN ENGINE ROOM.
Condition: Unknown
Due 3 February 1992
Resolved 3 February 1992
Lifesaving
Issued 4 February 1991 Resolved
PROVIDE 2 LIFE FLOATS FOR INSPECTION FOR A TOTAL OF FOUR. VESSEL IS LIMITEDTO THE CARRIAGE OF 50 TOTAL PERSONS ON AN OCEAN ROUTE UNTIL THIS REQUIRMENTIS CORRECTED. THIS SHALL BE DONE TO THE SATISFACTION OF THE COGNIZANT OCMINEW YORK.
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Construction/Loadline
Issued 23 March 1988 Resolved
INSTALL HARD PIPING IN WAY OF THE OVERBOARD DISCHARGE PIPING FROM THE PORT AND STARBOARD SANITATION HOLDING TANKS.
Condition: Unknown
Due 23 March 1988
Resolved 23 March 1988
Lifesaving
Issued 29 February 1988 Resolved
REPLACE THE LIFELINES ON FOUR (4) LIFE FLOATS.
Condition: Unknown
Due 29 February 1988
Resolved 29 February 1988
Navigation
Issued 29 February 1988 Resolved
PROVIDE AN OPERATIONAL TEST OF THE SSB RADIO. VESSELS ROUTE IS RESTRICTED TO COASTWISE: NOT MORE THAN TWENTY (20) MILES FROM A HARBOR OF SAFE REFUGE,UNTIL A SSB IS INSTALLED TO THE SATISFACTION OF A MARINE INSPECTOR.
Condition: Unknown
Due 29 February 1988
Resolved 29 February 1988
Lifesaving
Issued 29 February 1988 Resolved
PROPERLY MARK THE AMOUNT OF ADULT AND CHILDREN PFD'S ON THE STOWAGE CONTAINERS.
Condition: Unknown
Due 29 February 1988
Resolved 29 February 1988
Navigation
Issued 29 February 1988 Resolved
REPLACE EXISTING NAVIGATION LIGHTS WITH COAST GUARD APPROVED LIGHTS.
Condition: Unknown
Due 29 February 1988
Resolved 29 February 1988
Electrical
Issued 29 February 1988 Resolved
REPLACE MISSING GLOBE/GUARDS FOR LIGHT FIXTURES IN THE #2 COMPARTMENT AND FOREPEAK.
Condition: Unknown
Due 29 February 1988
Resolved 29 February 1988
Lifesaving
Issued 29 February 1988 Resolved
REPLACE THE THREE MISSING ORANGE DISTRESS FLARES.
Condition: Unknown
Due 29 February 1988
Resolved 29 February 1988
Accommodation/Occupational Safety
Issued 21 February 1985 Resolved
1. PROVIDE VENTILATION EXAUST DUCT IN ENGINE ROOM EXTENDING TO THE BOTTOM OF THE COMPARTMENT. THIS MUST BE COMPLETED TO THE SATISFACTION OF A COAST GUARD INSPECTOR NOT LATER THAN 25 MARCH 1985.
Condition: Unknown
Due 21 February 1985
Resolved 21 February 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.