01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 April 2026
Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. COI is not posted in passenger accommodation space. 46 CFR 176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2026
Resolved 22 April 2026
Resolution: COI posted
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 April 2026
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Electrical wiring insulation is worn exposing wires on the port generator starter and starboard main engine starter. Repair/replace to satisfaction of MI. 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2026
Resolved 22 April 2026
Resolution: Electrical wiring replaced or taped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 April 2026
Resolved
Diesel engine exhaust cooling installation shall be in accordance with 182.15-15. Temporary repair (patch) found on port side main engine sea suction cooling piping. Submit repair proposal and make repairs to satisfaction of MI. 46 CFR 182.20-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2026
Resolved 19 May 2026
Resolution: Aluminum patch welded onto suction piping.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 April 2026
No resolution recorded
Have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection and operation of all weathertight closures above the weather deck and the provisions for drainage of sea water from the exposed decks. Port side window in passenger accommodation space is cracked through. Replace window to satisfaction of MI. 46 CFR 176.802
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 10 April 2026
Resolved
All ducts shall be of rigid permanent construction of fire proof material and reasonably gastight from end to end. Ducting for mechanical blowers for engine room are fitted with duct tape. Remove duct tape and repair ducts as required by MI. 46 CFR 182.45(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2026
Resolved 19 May 2026
Resolution: Duct repair sheet metal installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 April 2026
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment under all practical conditions. During testing, vessel could not satisfactorily dewater lazarette due to failed bilge pipe coupling. Repair and test bilge system to satisfaction of MI.
46 CFR 182.25-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2026
Resolution: Repaired and tested to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 April 2026
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Port side generator was disassembled for repair. Repair and demonstrate proper operation of generator to satisfaction of MI.
46 CFR 183.01-15 (a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2026
Resolution: Repaired and tested to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 April 2026
Resolved
Each survival craft on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Two of four life floats found deteriorated with broken bights for grab lines and inner basket. Replace life floats to satisfaction of MI.
46 CFR 185.700 (a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2026
Resolution: New lifefloats installed onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 January 2025
Resolved
Fire hose shall be 1.5 inches in diameter and 50 feet in length. Port side fire hose had multiple pin hole leaks at base of fire station coupling. Replace fire hose.
46 CFR 181.15-10(c)
Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 13 January 2025
Resolution: Owner replaced with new hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 January 2025
Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Four bilge suction intakes in the engine room had clogged strainers. Clean strainers on main bilge suction and emergency bilge line.
46 CFR 182.25-5(b)
Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 13 January 2025
Resolution: Owner cleaned strainers.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 7 January 2025
Resolved
The owner shall ensure vessel is equipped with a vessel master key control system. Vessel must have list of all crew (identified by position) allowed to access key and kept in a logbook with dates/times, rooms, and name/rank of crew member when crew utilizes master key (can be electronic, must be readily available).
46 USC 3106
Policy Letter: 23-06
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 7 March 2025
Resolution: Logs in daily captains log
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 January 2025
Resolved
Auxiliary machinery of the internal combustion piston type shall comply with the provisions of this part. Starboard main engine had temporary patch on piping feeding into jacket water expansion tank. Replace or repair piping component.
46 CFR 182.05-1(a)
Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 7 March 2025
Resolution: Welded new pipe on starboard main engine heat exchanger
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 January 2025
Resolved
A battery charger intended for connection to a commercial supply voltage shall employ a transformer of the isolating type. The voltmeter gauge on the battery charger was broken. Replace gauge or battery charger installation.
46 CFR 183.05-20(f)
Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 13 January 2025
Resolution: Owner replaced battery charge voltmeter.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 January 2025
Resolved
The switchboards shall be adequately protected. The operating station distribution panel had missing circuit breaker cover. Install cover or spare breaker.
46 CFR 183.05-15(a)
Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2025
Resolved 13 January 2025
Resolution: Owner placed blank circuit breaker in switchboard opening.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 April 2024
Resolved
The intent of this part is to insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery
failure and personnel injury. The PORT side generator was inoperable. Repair to satisfaction of USCG in-person
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2024
Resolved 3 April 2024
Resolution: See description in narrative.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 1 April 2024
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. The pressure gauge at the fire pump read 40 psi consistently.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2024
Resolved 3 April 2024
Resolution: See deficiency description.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2024
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 13 adult sized life jackets had worn/deteriorated reflective material that needed to be replaced with new. Vessel's crew replaced retro-reflective material on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 April 2024
Resolved 1 April 2024
Resolution: Crew replaced retro-reflective material on 13 lifejackets on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 April 2022
Resolved
02 lifefloats were not primarily vivid reddish orange. Paint 02 discolored lifefloats and provide pictures to the USCG to rectify deficiency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2022
Resolved 6 May 2022
Resolution: Operator provided pictures attesting to the repair of life floats
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 March 2021
Resolved
Each vessel must have 1)permanent draft marks at each end of the vessel or alternatively 2)have permanent loading marks placed on each side of the vessel fwd and aft to indicate maximum allowable trim and amidships to indicate maximum allowable draft. Provide permanent Draft marks or loading Marks for the vessel.
Action required: 705 - Other - as specified
Resolved 17 April 2021
Resolution: Permanent draft marks installed and verified by Naval Architect.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2021
Resolved
AC 110V electrical panel in engine room, inboard STBD side, near entrance ladder has an unlabeled circuit (10 listed, 11 breakers in panel). Identify and label circuit on breaker panel. 46CFR183.10-10(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 22 March 2021
Resolution: Picture of 11th breaker on panel labled
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2021
Resolved
STBD engine fuel shut off is stuck in the open position, make functional. 46CFR182.20-40(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 26 January 2021
Resolution: [name withheld] was able to work the valve and it closes now.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2021
Resolved
Feed fresh water line, STBD side, passing through the forward engine room watertight bulkhead,has 3 sections of non-metallic piping (both flexible hose and PVC) fitted (1 in fwd engine room, 2 in aft boiler room). Replace these sections with original in-kind aluminum piping, alternatively fit metallic shut off valves directly connecting to bulkhead on both sides of the fwd engine room bulkhead, or one metallic valve on one side of bulkhead if it is made operable from the deck above. 46CFR182.115(b) & 46CFR182.720(e)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 14 April 2022
Resolution: During the annual inspection on 22APR2022, the condition of the forward engine room watertight bulkhead was satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 1 April 2020
Resolved
Structure in way of cable hangers is deteriorating; replace hangers with compatible materials or isolate hangers from structure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 20 July 2020
Resolution: Cable and associated hangers removed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 April 2020
Resolved
Provide repair proposal/mitigation plan for pitting identified under fixed ballast.
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 2 May 2020
Resolution: Area under ballast cleaned and recoated with coating system to preserve. To be checked at next annual and repaired at subsequent drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 April 2020
Resolved
Fuel sounding pipe terminates at top of fuel tank inside laz space. Filling and sounding pipes shall be so arranged that overflow of liquid or vapor cannot escape to the inside of the vessel. Sounding pipes may be omitted where sounding can be accomplished through the fill pipe or where marine type fuel gages are installed. Where sounding pipes are used, their openings shall be at least as high as the opening of the fill pipe and they shall be kept closed at all times except during sounding. Provide modification plan for meeting requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 20 July 2020
Resolution: Fuel sounding tube capped with spring loaded flapper.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 March 2020
Resolved
Provide a gauging report of the hull plate located underneath the fixed ballast in the #3 compartment. - 46 CFR 177.300
Action required: 705 - Other - as specified
Due 1 April 2020
Resolved 6 April 2020
Resolution: Area was measured with UT meter.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 January 2020
Resolved
A visual and audible bilge alarm to indicate high water in the void space must be provided at the operating station. Provide operable bilge alarm. - 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2020
Resolved 11 February 2020
Resolution: Verified with O/O via email that the issue was resolved.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 7 January 2020
Resolved
Outlets for the coffee pot and refrigerator are no longer serviceable. Replace outlets in kind. - 46 CFR 183.01-15 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2020
Resolved 11 February 2020
Resolution: O/O sent photographs of replaced outlets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 7 January 2020
Resolved
The floating water lights must be attached around the body of the life floats. Attach water lights as specified. - 46 CFR 180.175(f)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2020
Resolved 11 February 2020
Resolution: O/O sent photographs of re-attached water lights.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 January 2020
Resolved
Each life float must be individually attached to the painter by a line and long enough that each life float can float freely. Life float painter arrangement was incorrect. 46 CFR 180.137(e)(3)
Action required: 10 - Deficiency Rectified
Due 7 January 2020
Resolved 11 February 2020
Resolution: Resolved on the spot.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 January 2020
Resolved
A vessel on an oceans route is required a reserve power supply or handheld VHF radio telephone. Provide appropriate arrangement. - 46 CFR 184.25-1 (a) and 47 CFR 80.917
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 February 2020
Resolved 11 February 2020
Resolution: Received photographs from the O/O, handheld radio placed on the vessel.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 January 2020
Resolved
Repair or reweld indicated areas in the void space at the April 2020 drydock. - 46 CFR 176.05-10
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 6 April 2020
Resolution: Welds were repaired.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 October 2019
Resolved
Required monthly EPIRB test has not been logged since the month of MAY. Conduct and record the monthly test. Present evidence of logged test to marine inspector. 46 CFR 185.728
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 6 November 2019
Resolution: Provided proof.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 October 2019
Resolved
Fire axe is being stowed in storeroom. Locate the axe in or adjacent to the operating station. 46 CFR 181.35-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 6 November 2019
Resolution: Provided proof of mounting.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 October 2019
Resolved
Vessel fire hydrants do not have spanner wrenches. Procure spanners and locate them at the fire hydrants. 46 CFR 181-310(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 6 November 2019
Resolution: Provided evidence of spanner wrenches being present.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 October 2019
Resolved
Fire hoses are not attached to the fire hydrants at all times. Hoses were stowed in storeroom. Attach hoses to hydrants to satisfaction of attending marine inspector. 46 CFR 181.15-10 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 6 November 2019
Resolution: Provided evidence of hoses being stowed in location under benches. Hoses are stowed in designated location that they were intended for.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 October 2019
Resolved
Labeling for fuel shutoff valves has become illegible. Renew labeling. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 6 November 2019
Resolution: Fuel shut off labeling has been renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2019
Resolved
Master indicated that a passenger safety orientation public announcement is not made prior to voyages.
Provide to the attending marine inspector, a copy of the
announcement that is to be made prior to embarking on a
voyage. Hard copy is due in 14 days. Announcement to be
made immediately.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 6 November 2019
Resolution: Provided proof of having a printed emergency announcement.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 June 2019
Resolved
Secure the painter line assembly for the forward two life floats onto a more sturdy platform. 46 CFR 180.130(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 4 June 2019
Resolution: Received an email from the master.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 4 June 2019
Resolved
Patch one identified life float and make orange. Limit to carrying 63 passengers until complete. 46 CFR 180.202(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 4 June 2019
Resolution: Received an email from the master with a photograph of the life float.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2019
Resolved
Cap identified dead end wires under the operating station. 46 CFR 183.200(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2019
Resolved 4 June 2019
Resolution: Received an email from the master.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 June 2019
Resolved
Provide spanner wrenches for both fire stations. 46 CFR 181.310(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2019
Resolved 9 January 2020
Resolution: Administratively closed following 2020 COI.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 June 2019
Resolved
Provide FCC Bridge to Bridge Radiotelephony certificate. 46 CFR 80.1005
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2019
Resolved 7 June 2019
Resolution: Received a photograph of the certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 May 2019
Resolved
The vessel failed to undergo an annual inspection within three months of its anniversary date. Satisfactory inspection must be completed prior to the carriage of passengers. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 May 2019
Resolved
Vessel is unable to complete the annual inspetion within the 15th month of the COI anniversary date. Owner has requested, and has been granted a deferment past the 15th month. The annual inspection must be completed no later than June 4, 2019.
Action required: 705 - Other - as specified
Due 4 June 2019
Resolved 9 January 2020
Resolution: Administratively closed after 2020 COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 May 2019
Resolved
Vessel is unable to complete the annual inspection within the 15th month of the COI anniversary date. Owner has requested, and has been granted a deferment past the 15th month. The annual inspection must be completed no later than June 4th, 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2019
Resolved 4 June 2019
Resolution: Vessel received annual inspection, COI endorsed, on 04JUN.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 February 2019
Resolved
Clad weld 02 pits as marked in starboard forepeak, near chine. More permanent repair to be made at next drydock. 46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2019
Resolved 12 June 2019
Resolution: Received photographs from the master of the clad welds. Added special note to make permanent repairs at next dry dock.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 26 March 2018
Resolved
Strap broken on port side stuffing box; remove and replace broken strap.
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 4 April 2018
Resolution: Verified install of new metallic strap.
Engineering › Fuel Oil Service System › Hose
Issued 26 March 2018
Resolved
Add chafing gear to hoses on both engines
Action required: 705 - Other - as specified
Due 6 April 2018
Resolved 4 April 2018
Resolution: Verified installation of chaffe gear on main engines.
Fire Fighting › Remote Fuel Shutoff › General
Issued 29 March 2017
Resolved
AB01: Vessel's Emergency Fuel shut off's must be marked. 46 CFR 185.608
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 19 April 2017
Resolution: [name withheld] verified in person
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 29 March 2017
Resolved
AB02: Vessel must have current/up to date charts of Area of Operation. 46 CFR 184.410
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 19 April 2017
Resolution: [name withheld] verified in person
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 29 March 2017
Resolved
AB03: Vessel must conduct general crew and supervisory drug awareness training. 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 19 April 2017
Resolution: [name withheld] verified in person
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 29 March 2017
Resolved
AB04: Starboard Life Ring must have vessels name on it.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2017
Resolved 19 April 2017
Resolution: [name withheld] verified in person
Engineering › Bilge Water Management System › Piping
Issued 11 February 2016
Resolved
Replace all non-metallic material including flexible piping in bilge and fire system piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 24 March 2016
Resolution: Removed flexible piping
Fire Fighting › Fire Main › Condition
Issued 11 February 2016
Resolved
Repair or replace fire main piping in damaged area.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 24 March 2016
Resolution: Replaced piping and tested sat.