BARVIC

BARVIC is a 1975 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1985, most recently in May 2012, along with 79 deficiencies and 2 casualty investigations between 2011 and 2013.

Records from 1985 to 2013. Most recent: casualty investigation, 8 June 2013.

Built
1975
Last inspected
18 May 2012
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD7460
Flag
UNITED STATES
367186750 (licence lapsed)
Maury page id
psix-48443

Inspections, by type

…with no type recorded5
Years with a record 27 calendar years (1985–2012)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.3 ft × 17.7 ft × 5.3 ft
Registered tonnagegross 40 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · DELTAVILLE, VA, UNITED STATES · built 1975
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Regulatory (Subpart C or D), Gross Ton
27 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD7460MMSI 367186750 · expired · compulsorily equipped · granted 11 May 2007, cancelled 15 July 2017
WAY3928MMSI not assigned · expired · compulsorily equipped · granted 28 August 1996, cancelled 21 October 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 53

18 May 2012 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4308848
8 May 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4304792
17 August 2011 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4118204
4 July 2011 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4068489
4 July 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4074383
29 July 2009 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3548185
16 April 2009 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3453295
5 August 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3290052
3 May 2007 COI Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2919309
7 June 2006 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2670501
1 September 2005 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2480404
18 May 2005 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2360844
9 June 2004 Deficiency Check · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2093387
11 August 2003 Annual Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1872883
11 July 2003 Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1842886
15 May 2003 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1793470
21 May 2002 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1618584
31 July 2001 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1070797
15 May 2001 Deficiency Check · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1453895
14 February 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1058302
6 June 2000 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 821650
27 May 1999 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1084834
12 May 1999 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 798475
28 May 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 792436
4 June 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 776953
20 May 1997 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1398685
26 August 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1258678
14 June 1996 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1416327
31 May 1996 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084954
31 May 1996 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1090050
13 June 1995 Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 880236
23 May 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 875634
7 June 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869968
8 June 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158874
28 May 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158873
9 June 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1257823
2 June 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 947511
25 October 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006205
17 June 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249898
6 June 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246036
13 June 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 930325
30 May 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 911483
12 June 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1203154
7 June 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1198300
22 June 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1208297
26 May 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 893513
24 July 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1333855
6 July 1987 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1014478
6 June 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1302186
20 May 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991007
20 May 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1302191
7 June 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1285846
23 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979546

Deficiency record · 79

Construction/Loadline › Hull › Hull Plating
Issued 4 July 2011 Resolved
Vessel was struck by another vessel causing a cracked plank and a hole in the vessel. Plank needs to be repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2011
Resolved 17 August 2011
Resolution: Vessel was repaired in accordance w/ [name withheld] was completed by 01 Aug 2011, and vessel was allowed to sit in the water for 2 days prior to check ride. Vsl was inspected during operation, and reinspected on 17 August 11 during annual inspection. All Sat
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 29 July 2009 Resolved
Properly service the fixed fire fighting system.
Action required: 705 - Other - as specified
Due 6 August 2009
Resolved 25 August 2009
Resolution: System properly serviced by qualified technician.
Lifesaving › Lifefloat › Float-free Link
Issued 29 July 2009 Resolved
Install properly sized weak link on forward Lifefloat.
Action required: 705 - Other - as specified
Due 6 August 2009
Resolved 25 August 2009
Resolution: Owner installed [name withheld] weak link of appropriate size.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 July 2009 Resolved
Secure wiring in #1 compartment.
Action required: 705 - Other - as specified
Due 6 August 2009
Resolved 25 August 2009
Resolution: Wiring secured using metallic clips. Install sat.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 July 2009 Resolved
Properly secure battery for the anchor hauling gear.
Action required: 705 - Other - as specified
Due 6 August 2009
Resolved 25 August 2009
Resolution: Battery is located in a battery box, secured to the deck with a bungee cord. All sat.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 29 July 2009 Resolved
Adjust port shaft packing so that the ingress of water in minimized.
Action required: 705 - Other - as specified
Due 6 August 2009
Resolved 25 August 2009
Resolution: Observed shaft operating both ahead and astern. All sat.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 29 July 2009 Resolved
Make the clamps for Port exhaust silencer available for inspection by removing the duct tape covering.
Action required: 705 - Other - as specified
Due 6 August 2009
Resolved 25 August 2009
Resolution: Observed exhaust clamps on port exhaust system. All sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 July 2009 Resolved
Remove dead end wire runs from enging room main cable run.
Action required: 705 - Other - as specified
Due 6 August 2009
Resolved 25 August 2009
Resolution: Engine room cable run inspected, all sat.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 July 2009 Resolved
Prove proper operation of the fixed fire fighting systems engine room shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2009
Resolution: Conducted operational test of system. All sat.
Operations/Management › Drug and Alcohol Testing › Testing, Reasonable Cause
Issued 5 August 2008 Resolved
A chemical testing program as required by 46CFR16 is not in place.
Action required: 705 - Other - as specified
Due 14 August 2008
Resolved 13 August 2008
Resolution: Proof sent to CG via fax
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 5 August 2008 Resolved
Generator exhaust hose is excessively deteriorated. Replace with acceptable hose and prove proper operation of exhaust system.
Action required: 705 - Other - as specified
Due 14 August 2008
Resolved 14 August 2008
Resolution: Inspected the new flexible hose for the exhaust. All sat
Stability › Watertight Integrity › General
Issued 1 September 2005 Resolved
Water leak at top of stbd chine plank located in E/R, 1" above waterline.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2005
Resolution: Owner corrected during inspection at the pier. Recaulked and sealed seam. Tested u/w, repairs complete.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 1 September 2005 Resolved
L/F float light line inadequate length (8'), owner to replace with minimal length of 18'.
Action required: 705 - Other - as specified
Due 7 October 2005
Resolved 7 October 2005
Resolution: corrected
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 September 2005 Resolved
Throw ring line inadequate length (40'). Owner to replace with correct length of 60'
Action required: 705 - Other - as specified
Due 7 October 2005
Resolved 7 October 2005
Resolution: Corrected
Electrical › Electric Generation Source (service) › Panelboard
Issued 1 September 2005 Resolved
Generator Herz gauge inoperable.
Action required: 705 - Other - as specified
Due 7 October 2005
Resolved 7 October 2005
Resolution: Corrected
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 1 September 2005 Resolved
Failed two child life jackets. Owner has 3 onboard, vsl restricted to carriage of 3 children/persons under 90 pounds.
Action required: 705 - Other - as specified
Due 7 October 2005
Resolved 7 October 2005
Resolution: Corrected
Engineering › Freshwater System (intermediary cooling) › Fitting
Issued 1 September 2005 Resolved
Port MDE exhaust muffler has small leak of R/W at aft clamp.
Action required: 705 - Other - as specified
Due 7 October 2005
Resolved 7 October 2005
Resolution: Corrected, received tech repair report dtd 27 Sep 05
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 1 September 2005 Resolved
Excessive water flow from both shaft packings. Owner to repack, unable to further compress packing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2005
Resolution: Owner sent faxed statement attesting to proper repairs.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 September 2005 Resolved
Vessel owner operated the vessel beyond the 90 day re-inspection window of his COI anniversary date.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2005
Resolution: Re-inspection complete.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 18 May 2005 Resolved
Replace damaged bilge pump float switch in compartment #2.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: Installed new float switch, tested sat.
Engineering › Bilge Water Management System › Hose
Issued 18 May 2005 Resolved
Replace hose and rusted clamps on bilge piping in compartment #2.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: corrected.
Construction/Loadline › Penetrations › Pipe Flange
Issued 18 May 2005 Resolved
Cap off side shell through hull fitting (stbd side) for r/w discharge from old gen set.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: fitting capped.
Engineering › Freshwater System (intermediary cooling) › Hose
Issued 18 May 2005 Resolved
Install double hose clamps on all r/w hoses outboard of stbd MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 18 May 2005 Resolved
Secure engine mounts for stbd MDE (fwd, outboard) and generator (aft).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: Lag bolt tightened on MDE, new lag bolt installed on gen set mount.
Construction/Loadline › Hull › Hull Plating
Issued 18 May 2005 Resolved
Make proper repairs to butt end of planks (2) on stbd aft quarter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: Winters wood boat repair specialist, [name withheld], assessed damage and made repairs outlined in narrative.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 18 May 2005 Resolved
Renew both strut bearings due to excessive play.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: Owner installed new bearings and verified with Winter''s Marina and given receipt for repairs.
Construction/Loadline › Structures › Scuttle
Issued 18 May 2005 Resolved
Replace worn deck hatch gaskets, lazarette and forepeak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: Gaskets replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2005 Resolved
Correct stray wiring in aft tank space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: removed.
Construction/Loadline › Penetrations › Pipe Flange
Issued 18 May 2005 Resolved
Cap off side shell through hull fitting (port side) for r/w discharge from old gen set.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: capped off.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2005 Resolved
Remove or properly tagout dead end wiring, port side E/R
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: removed.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 18 May 2005 Resolved
Re-attach reach rod for bilge valve in fwd compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: Corrected.
Construction/Loadline › Hull › Hull Plating
Issued 18 May 2005 Resolved
Complete worklist and perform u/w checkride on wood hull prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2005
Resolution: completed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 June 2004 Resolved
Water light working sporadically.
Condition: Improper/Lack of Maintenance
Due 26 June 2004
Resolved 22 June 2004
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 June 2004 Resolved
Replace 3 adult life jackets worn and wasted straps
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 June 2004
Resolved 22 June 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 9 June 2004 Resolved
Service fixed fire fighting system prior to 01 Aug 2004. A faxed copy of a service inspection report from a certified fire system company will be acceptable. This report must be received by the Marine Inspection Dept. in Philadelphia office NLT the date specified.
Action required: 705 - Other - as specified
Due 1 August 2004
Resolved 28 July 2004
Resolution: Received a faxed copy from the vessel owner confirming the inspection of the vessel''''s installed fixed Halon system. System was inspected and all sat. A copy of the receipt for services attached to case.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 9 June 2004 Resolved
Repack port rudder shaft packing.
Due 26 June 2004
Resolved 22 June 2004
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 June 2004 Resolved
Prove proper operation of emergency fuel shut-offs.
Due 26 June 2004
Resolved 22 June 2004
Engineering › Bilge Water Management System › Piping
Issued 9 June 2004 Resolved
Clear fixed bilge system by way of forward comp. Bilge line working but appears partially clogged.
Due 26 June 2004
Resolved 22 June 2004
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 June 2004 Resolved
Treat angel hair in crash, forward and laz compartment as discussed.
Due 26 June 2004
Resolved 22 June 2004
Operations/Management › Drug and Alcohol Testing
Issued 11 August 2003 Resolved
Provide proof of enrollment for employees in Drug Testing Consortium. LEGACY COMPONENT DESC: Proof of Enrollment
Due 13 September 2003
Resolved 16 September 2003
Documentation › Logs/Records
Issued 11 August 2003 Resolved
Mount Passenger count box on pier.
Due 13 September 2003
Resolved 16 September 2003
Navigation › Collision/Grounding Avoidance
Issued 11 August 2003 Resolved
Repair Stbd running light. LEGACY COMPONENT DESC: Navigation Lights
Due 13 September 2003
Resolved 16 September 2003
Communications › Alarms/Indicators
Issued 11 August 2003 Resolved
Label bilge alarm panel on bridge. LEGACY COMPONENT DESC: Bilge Alarm
Due 13 September 2003
Resolved 16 September 2003
Engineering › Fuel Oil Service System
Issued 11 August 2003 Resolved
Label Emergency fuel shut off valve location. LEGACY COMPONENT DESC: Valve
Due 13 September 2003
Resolved 16 September 2003
Communications › Alarms/Indicators
Issued 11 August 2003 Resolved
Prove proper operation of bilge alarm switch in fwd crash compartment. LEGACY COMPONENT DESC: Bilge Alarm
Due 13 September 2003
Resolved 16 September 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 11 August 2003 Resolved
Prove proper operation of Stbd MDE.
Due 13 September 2003
Resolved 16 September 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 11 August 2003 Resolved
Repair port MDE exhaust riser R/W leak. LEGACY COMPONENT DESC: Piping (exhaust)
Due 13 September 2003
Resolved 16 September 2003
Construction/Loadline › Structures
Issued 14 May 2003 Resolved
REPAIR WORM DAMAGE ON KEEL BEHIND WORM SHOE. LEGACY COMPONENT DESC: Keel
Due 15 July 2003
Resolved 16 May 2003
Resolution: Scarfed in new section of keel approx. 2 ft in length, 1 3/4 inch thick.
Construction/Loadline
Issued 14 May 2003 Resolved
REPAIR ROTTED WOOD BACKING ON ALL THREE HATCHES IN WAY OF LAZARETTE AND TANK SPACE.
Due 15 July 2003
Resolved 15 June 2003
Resolution: Renewed with sound wood backing.
Construction/Loadline
Issued 14 May 2003 Resolved
REMOVE ANGEL HAIR AND PRESERVE ALL STRUCTURAL MEMBERS IN ENGINE ROOM.
Due 15 July 2003
Resolved 15 June 2003
Resolution: Corrected.
Communications › Radio Communications
Issued 21 May 2002 Resolved
PROVIDE PROOF OF NEW EPIRB BATTERY. LEGACY COMPONENT DESC: EPIRB
Due 30 June 2002
Resolved 1 July 2002
Resolution: VESSEL PROVIDED PROOF OF NEW EPIRB BATTERY WITH RENEWAL DATE OF 6/07
Construction/Loadline
Issued 15 May 2001 Resolved
ENTIRE HULL RE-FASTENED DURING THIS CREDITED DRY DOCK. REQUIRE A VESSEL CHECK RIDE AND COMPARMENT INSPECTION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
Lifesaving
Issued 14 February 2001 Resolved
PROVIDE APPROVED METHOD OF MEETING COLD WATER LIFESAVING REQUIREMENTS BY 11MARCH 2001. IF UNABLE TO MEET REQUIREMENTS VESSEL IS RESTRICTED TO LIMITEDCOASTWISE ROUTE NOT MORE THAN THREE NAUTICAL MILES FROM SHORE AND PASSENGERCOUNT TO 25 UNTIL 01 JUNE 2001.
Condition: Unknown
Due 1 June 2001
Resolved 11 July 2003
Resolution: Vessel COI changed to reflex cold water lifesaving requirements. Vessel is restricted warm water operating only.
Lifesaving
Issued 28 May 1998 Resolved
PRIOR TO OPERATING WITH MORE THAN 44 ADULTS, PROVIDE 6 ADULT PFD'S.
Condition: Unknown
Due 10 June 1998
Resolved 22 June 1998
Lifesaving
Issued 28 May 1998 Resolved
PROVIDDE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PROOF OF ENROLLMENT IN A DRUG PROGRAM NO LATER THAN 10 JUNE 1998.
Condition: Unknown
Due 10 June 1998
Resolved 22 June 1998
Construction/Loadline
Issued 28 May 1998 Resolved
AT NEXT DRYDOCK, NO LATER THAN 10 JUNE 1998, REPLACE BUTT BLOCKS IN ENGINE ROOM PORT SIDE BAY 4 AND STBD SIDE BAY 6 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 June 1998
Resolved 22 June 1998
Construction/Loadline
Issued 4 June 1997 Resolved
REBOLT HALF BULKHEAD IN #2 COMPARTMENT, PORT SIDE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Navigation
Issued 4 June 1997 Resolved
PORT RUDDER POST FOUND CRACKED BY OWNER, AND NEEDS TO BE REPLACED.
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Construction/Loadline
Issued 4 June 1997 Resolved
REPAIR SMALL LEAK ABOVE WATERLINE IN #2 COMPARTMENT ON THE PORT SIDE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Lifesaving
Issued 4 June 1997 Resolved
REPAIR OR REPLACE 10 ADULT AND TWO CHILD PFD'S._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 1997
Resolved 9 June 1997
Engineering
Issued 31 May 1996 Resolved
INSTALL BONDING WIRE ON BOTH F/O FILL PIPES.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Unknown
Issued 31 May 1996 Resolved
PROVIDE PROOF OF COMPLIANCE OF CREW TRAINING IAW 46 CFR 185.420
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Engineering
Issued 31 May 1996 Resolved
REPAIR STBD COOLING WATER LEAK ON MANIFOLD TRANSITION PIECE.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Unknown
Issued 31 May 1996 Resolved
PROVIDE PROOF OF COMPLIANCE OF EMERGENCY DRILLS IAW 46 CFR 185.520 & 185.524
Condition: Unknown
Due 31 May 1996
Resolved 31 May 1996
Construction/Loadline
Issued 31 May 1996 Resolved
RESEAL LEAKING PLANKS IN E/R AS NOTED DURING INSPECTION AT UPCOMING NONCREDIT DRYDOCKING.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Construction/Loadline
Issued 31 May 1996 Resolved
RECAULK ENTIRE CHINE AT UPCOMING NON CREDIT DRYDOCKING.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Fire Fighting
Issued 13 June 1995 Resolved
PROVIDE DOCUMENTATION FOR 6 YEAR SERVICE ON DRY CHEM BII EXTINGUISHER IN ACCOMODATION SPACE.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Lifesaving
Issued 13 June 1995 Resolved
RENEW LIFELINES BY BOTH LIFEFLOATS (10MAN FORWARD).
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Lifesaving
Issued 13 June 1995 Resolved
PROVIDE 19 ADULT LIFE JACKETS. NUMBER OF PASSENGERS THAT MAY BE CARRIED ISREDUCED TO 31 UNTIL REPLACEMENT JACKETS ARE PROVIDED.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Lifesaving
Issued 13 June 1995 Resolved
PROVIDE ONE ADDITIONAL PADDLE FOR FORWARD LIFEFLOAT.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Lifesaving
Issued 13 June 1995 Resolved
NUMBER OF PASSENGERS THAT MAY BE CARRIED IS REDUCED TO 28 POB UNTIL LIFELINES ON LIFEFLOATS ARE REPAIRED.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Navigation
Issued 13 June 1995 Resolved
PROVIDE CHARTS FOR ENTIRE OPERATING AREA.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Electrical
Issued 17 June 1991 Resolved
DEMONSTRATE PROPER OPERATION OF AN 3KW GENERATOR (PORTSIDE)
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Construction/Loadline
Issued 17 June 1991 Resolved
RENEW AS ORIGINAL IN LIKE QUALITY AND KIND. THE REACH ROD FOR BILGE VALVE LOCATED FWD OF COLLISON BULKHEAD.
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Unknown
Issued 7 June 1989 Resolved
REPAIR REMOTE VALVE TO BILGE LINE FORWARD MOST COMPARTMENT.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Engineering
Issued 7 June 1989 Resolved
REPLACE AS NEEDED STAINLESS STEEL HOSE CLAMPS ON PORT/STARBOARD FLEXIBLE EXHAUST HOSE IN AFT COMPARTMENT.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Unknown
Issued 7 June 1989 Resolved
REATTACH BILGE STRAINER TO BILGE LINE IN FORWARD MOST COMPARTMENT.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Navigation
Issued 6 July 1987 Resolved
PROVIDE TWO MILE STERN, THREE MILE MAST AND ANCHOR LIGHTS.
Condition: Unknown
Due 6 July 1987
Resolved 6 July 1987
Lifesaving
Issued 6 July 1987 Resolved
MARK OR STENCIL STOWAGE COMPARTMENT FOR FIVE CHILD PFDS WHERE MISSING.
Condition: Unknown
Due 6 July 1987
Resolved 6 July 1987

Casualty record · 2

4 July 2011Routine · role: Involved in a Marine Casualty · 1 injured · activity 4074383
8 June 2013Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 4616768
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.