MAURY USCG vessel records
← All vessels

BAYVIEW

Built
1998
Last inspected
10 June 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 June 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ8599
484541
Flag
UNITED STATES
Maury page id
psix-484541

Documentation record

Registered dimensions (L × B × D)38.0 ft × 11.0 ft × 3.0 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCANAL BOATS INC · FORT LAUDERDALE, FL, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portFORT LAUDERDALE, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 20 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
8 - Simplified, Net Ton
18 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

10 June 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8156240
10 October 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8009100
2 October 2024 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8031052
9 November 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7832124
11 October 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7574635
23 September 2022 Administrative Inspection · Simplified Stability Test
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7570287
3 June 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7467348
1 September 2021 COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7289128
5 January 2021 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7121581
7 October 2020 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7072469
18 December 2019 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6875526
8 January 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6605500
26 September 2018 Internal Structural Exam · Administrative Inspection · Drydock Exam · Re-Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6548253
4 January 2018 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6332352
6 October 2016 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5990490
29 September 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6013054
4 January 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5795653

Deficiency record · 10

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 10 June 2025 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. MOB emergency procedures needs to be posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 14 July 2025
Resolution: Placard replaced, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 June 2025 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. Multiple rails on the bow need to be secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 14 July 2025
Resolution: Weld repairs made, all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 June 2025 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Over ride switch at the operating station needs to be operable.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 June 2025
Resolved 10 June 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 June 2025 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. The vessel master/crew lacked training in their responsibilities during man overboard drill due to the man overboard platform.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2025
Resolved 14 July 2025
Resolution: Training conducted, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 September 2021 Resolved
... The condition of all parts of the vessel and its machinery may be checked to determine if the vessel is Satisfactory in all respects for the service intended. During the inspection latches and gaskets on engine room hatches need to be replace to ensure a good seal to prevent water intrusion into the engine room. 46 CFR 176.402
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 29 September 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 September 2021 Resolved
Penetrations and openings in watertight bulkheads must; have means to make them water tight. There are penetrations on engine room bulkheads. Seal with approve material. 46 CFR 171.114(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 29 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 September 2021 Resolved
... The pump outlet must be fitted with a pressure gauge. Pressure gauge on pump outlet is inop. Additionally, Overboard valve handle needs to be replace to ensure full closure of valve when hose is being use. Replace both and test to ensure proper operation.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 29 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 January 2021 Resolved
Each lifejacket must be marked with type i retroreflective material approved in 46 CFR 164.018. 24 lifejackets require new retroreflective tape. 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2021
Resolved 8 January 2021
Resolution: MI verified retroreflective tape replaced while conducting COI Renewal on 08JAN2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 December 2019 Resolved
Safety Radiotelephony Certificate is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 January 2020
Resolution: obtained copy of new FCC radiotelephony certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 December 2019 Resolved
Retro-reflective tape is worn on identified lifejackets. Replace Solas approved tape.
Action required: 10 - Deficiency Rectified
Resolved 18 December 2019
Resolution: Company has extra rolls of Solas retro-reflective tape and replaced all identified lifejackets with new tape prior to the conclusion of the inspection.