Inspection history · 14
22 June 2026
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8409920
21 April 2026
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8353283
7 May 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8130131
6 March 2024
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7874532
21 March 2023
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7654596
15 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7412407
10 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7409647
15 March 2021
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7156651
26 March 2020
Drydock Exam · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6931893
1 April 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6654011
13 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6510230
20 February 2018
Hull Examination · Administrative Inspection · COI Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6355530
6 April 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6118690
25 January 2016
Internal Structural Exam · Administrative Inspection · DAPI Audit · Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5802984
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 June 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. MI observed two outlets improperly connected in series via non-permanent, pigtailed cordage. Operator must establish a permanent electrical connection between two outlets prior to usage of main block heater.
46CFR183.200(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 26 June 2026
Resolution: MI received repair completion report with photos.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 June 2026
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150 F, must be suitably insulated where necessary to prevent injuries. Install appropriate exhaust lagging on port and stbd side aft bulkhead of engine room and port side of shaft compartment. MI observed missing or damaged lagging material on main engine exhaust piping on both sides.
46 CFR 177.970
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 July 2026
Resolution: MI received two photos of newly installed lagging materials on both (p/s) exhaust pipes.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 April 2026
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel is currently operating without a current drydock/ISE. Vessel is not authorized to operate in commercial service until a credit drydock/ISE is completed by a Coast Guard Marine Inspector. 46CFR176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2026
Resolved 22 April 2026
Resolution: Drydock/ISE complete.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 May 2025
Resolved
"...each vessel constructed of a material other than wood certified to operate on a limited coastwise route in cold water must be provided with life floats...that will accommodate at least 100% of the total number of persons permitted..." vessel had expired HRU on IBA. Ensure vessel has adequate lifesavings onboard.
46 CFR 180.205(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2025
Resolution: Locate photographic correction under "Documents" tab.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 March 2024
Resolved
...vessel not required to have a power driven fire pump... must have at least three 9.5 liter buckets...vessel has 2 fire buckets.
Action required: 10 - Deficiency Rectified
Resolved 21 March 2024
Resolution: Received photographic evidence.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 March 2022
Resolved
Vessel needs updated DAPI consortium enrollment for 2022.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2022
Resolution: Operator sent verification that the vessel is currently enrolled in a consortium for 2022.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 March 2022
Resolved
In void space forward of engine room compartment spray foam was used to seal an opening between void space and engine room just above the bilge pick up.
VSL representative is to provide proof foam is sufficient to remain watertight and the foam used is applicable for intended use.
Vsl is to complete work list items prior to credit dry dock.
Action required: 705 - Other - as specified
Due 10 March 2022
Resolved 17 March 2022
Resolution: Attending MI verified insulation between void space and engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2021
Resolved
Port fuel filter is dripping and bottom plug is not secure. Fix plug to mitigate leakage. 46 CFR 182.455(b)(9).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 22 March 2021
Resolution: Owner sent photos of new fuel filter plugs
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 March 2021
Resolved
Provide proof that current crew are enrolled in the DAPI program as well as a record of random testing. 46 CFR 16.230.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 1 April 2021
Resolution: O/O Sent documents from consortium that listed crew members enrolled as well as provided history of random drug testing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2021
Resolved
2x life jackets have had their retro reflective tape spray painted over. Retro reflective tape must re-applied. 46 CFR 185.604(h).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 22 March 2021
Resolution: Owner sent photos of the life jackets in question with new retro reflective tape applied.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 March 2021
Resolved
Aspirin, Eyewash, and disinfectant were expired from the first aid kit in the operation station. Replace all expired products. 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2021
Resolved 1 April 2021
Resolution: O/O Submitted invoice of replaced items
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 March 2021
Resolved
Vessel's log did not contain EPIRB test. Corrected on the spot.46 CFR 185.728.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 16 March 2021
Resolved 16 March 2021
Resolution: Corrected on the spot by having the crew fill out their vessel log with EPIRB test.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 March 2020
Resolved
Vessel did not complete a credit hull inspection prior to 29FEB2020 as required on it's COI. Complete a credit hull inspection prior to carrying passengers. - 46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2020
Resolution: Completed credit DD/ISE
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2019
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with an attached lanyard. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. Vsl did not have fire buckets on board. Vsl cannot carry passengers until fire buckets are provided.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 April 2019
Resolved 16 April 2019
Resolution: Received picture from vsl rep of Fire Buckets. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2019
Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that a positive shutoff valve is installed at the hull penetration. The submersible electric bilge pump in the lazerette does not have a positive shutoff valve at the hull penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2019
Resolved 24 April 2019
Resolution: Received picture of satisfactory installation of positive action valve at the hull penetration.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2019
Resolved
Each ring buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel's life ring buoy was not marked with vessel's name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2019
Resolved 16 April 2019
Resolution: Received picture from vsl rep of life ring marked with vsl's name. All Sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 August 2018
Resolved
Vsl is broadcasting: Invalid IMO #, no dimension information (AIS Antenna Position ABCD values equals 0), and not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 September 2018
Resolved 6 November 2018
Resolution: AIS information is updated.
Fire Fighting › Fire Bucket › Availability
Issued 10 April 2018
Resolved
Vessel is missing one fire bucket. Provide new fire bucket.
Action required: 705 - Other - as specified
Due 17 April 2018
Resolved 11 April 2018
Resolution: Additional fire bucket provided.
Stability › Watertight Integrity › General
Issued 10 April 2018
Resolved
Lazarette and engine room hatches are not tightly dogged. Make adjustemtns or replace with new to restore watertight integrity.
Action required: 705 - Other - as specified
Due 17 April 2018
Resolved 11 April 2018
Resolution: New hatches were installed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 April 2018
Resolved
One adult PFD is missing strap for securing. Provide new PFD.
Action required: 705 - Other - as specified
Due 17 April 2018
Resolved 11 April 2018
Resolution: New PFD provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 February 2018
No resolution recorded
Submit electrical one-line to marine safety center for electrical installations.
Action required: 705 - Other - as specified
Due 20 March 2018 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 28 January 2016
Resolved
46CFR 185.510: Update/replace MOB/emergency instructions to reflect how vessel/crew actually conducts drills/MOB. Current placard is standard verbiage from CFR & does not/ is not applicable to vessel ALEXIS.
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 24 April 2019
Resolution: Received picture from vsl rep with procedures for vessel. All Sat.