MAURY USCG vessel records Sign in
← All vessels

LIONEL B

LIONEL B is a 1998 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2001, most recently in March 2010, along with 47 deficiencies — 2 with no resolution recorded —.

Records from 2001 to 2010. Most recent: inspection, 25 March 2010.

Built
1998
Last inspected
25 March 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA6065
484609
Flag
UNITED STATES
—
Maury page id
psix-484609

Inspections, by type

…with no type recorded1
…past their stated due date2
Years with a record 6 calendar years (2001–2010)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it42 - Simplified, Gross Ton
33 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 12

25 March 2010 DAPI Audit · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3698884
9 March 2010 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3690387
11 March 2008 Administrative Inspection · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3158856
10 October 2006 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2797896
20 November 2003 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1952592
8 September 2003 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1899726
20 August 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1881801
14 August 2003 Examination of Repairs · In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1875925
20 September 2002 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1678168
30 August 2002 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1668690
17 July 2002 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1648016
23 November 2001 Initial Construction-Excluding Oversight · Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1445902

Deficiency record · 47

Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 25 March 2010 Resolved
Repair/Replace shore tie and generator interlock.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 30 March 2010
Resolution: Repaired shore tie and generator interlock.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 25 March 2010 No resolution recorded
Demonstrate proper operation of fire boy system.
Action required: 705 - Other - as specified
Due 25 April 2010 — due date passed with no resolution recorded
Resolution: Demonstrated proper operation of fire boy system.
Lifesaving › Launching Appliances › Release Mechanism
Issued 25 March 2010 Resolved
Replace hydrostatic release for EPIRB.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 30 March 2010
Resolution: Replaced hydrostatic release for EPIRB.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 March 2010 Resolved
Relabeled lifejacket stowage to reflect correct number.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 30 March 2010
Resolution: Relabeled lifejacket stowage to reflect correct number.
Deck/Cargo › Holds/Tanks › Hatch
Issued 25 March 2010 No resolution recorded
Properly secure hatches with lanyards.
Action required: 705 - Other - as specified
Due 25 April 2010 — due date passed with no resolution recorded
Resolution: Properly secured hatches with lanyards.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 March 2010 Resolved
Provide valid COD.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 30 June 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 March 2010 Resolved
Double clamp R/W hoses on generator.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 30 March 2010
Resolution: Double clamped R/W hoses on generator.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 March 2010 Resolved
Drain battery box in steering compartment.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 30 March 2010
Resolution: Drained battery box in steering compartment.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 March 2010 Resolved
Mount fire extinguisher in engine room.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 30 March 2010
Resolution: Mounted fire extinguisher in engine room.
Lifesaving › Lifebuoys › Stowage
Issued 25 March 2010 Resolved
Secure oars to life floats.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 30 March 2010
Resolution: Secured oars to life floats.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 March 2010 Resolved
Secure battery located under console.
Action required: 705 - Other - as specified
Due 25 April 2010
Resolved 30 March 2010
Resolution: Secured battery located under console.
Communications › Alarms/Indicators
Issued 20 November 2003 Resolved
Properly mount bilge alarm floats in engine room and fore peak before carrying passengers LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2003
Construction/Loadline › Hull
Issued 11 September 2003 Resolved
Make proper repair to welds on generator cradle (aft corners). LEGACY COMPONENT DESC: Weld
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 26 September 2003
Resolution: Owner properly repaired welds on generator cradle (aft corners).
Pollution Prevention/Response › Prevention Equipment
Issued 11 September 2003 Resolved
Properly mount high level bilge alarm in lazarette. LEGACY COMPONENT DESC: Bilge Monitor
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 26 September 2003
Resolution: Owner properly mounted high level bilge alarm in lazarette.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 11 September 2003 Resolved
Prove annual fire extinguisher servicing on lazarette extinguisher. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 26 September 2003
Resolution: Owner proved annual fire extinguisher servicing on lazarette extinguisher.
Engineering › Bilge Water Management System
Issued 11 September 2003 Resolved
Properly install hose clamps on bilge pump discharge in engine room. LEGACY COMPONENT DESC: Hose
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2003
Resolved 26 September 2003
Resolution: Owner properly installed hose clamps on bilge pump discharge in engine room.
Engineering › Sea-water System (primary cooling)
Issued 11 September 2003 Resolved
Properly install hose clamps on raw water pump discharge on generator. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2003
Resolved 26 September 2003
Resolution: Owner properly installed hose clamps on raw water pump discharge on generator.
Lifesaving › Hand Flares
Issued 11 September 2003 Resolved
Provide proper flares for route/conditions. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 26 September 2003
Resolution: Owner provided proper flares for route/conditions.
Deck/Cargo › Holds/Tanks
Issued 11 September 2003 Resolved
Make proper repairs to fuel tank to eliminate leaks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2003
Resolved 26 September 2003
Resolution: Owner made proper repairs to fuel tank.
Operations/Management › Drills/Instruction
Issued 11 September 2003 Resolved
Conduct underway drills. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 26 September 2003
Resolution: Lionel B conducted satisfactory underway drills.
Pollution Prevention/Response › Prevention Equipment
Issued 11 September 2003 Resolved
Prove proper operation of MSD. LEGACY COMPONENT DESC: Marine Sanitation Device, Type 1
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 11 September 2003
Resolution: Vsl
Lifesaving › Buoyant Apparatus
Issued 11 September 2003 Resolved
Provide proper retro-reflective tape for life floats.
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 26 September 2003
Resolution: Owner provided proper retro-reflective tape for life floats.
Accommodation/Occupational Safety › Medical/First Aid
Issued 11 September 2003 Resolved
Prove 50% of crew to be First Aid/CPR certification.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2003
Resolved 26 September 2003
Resolution: Owner proved 50% of crew to be First Aid/CPR certified.
Personnel › Manning/Qualifications
Issued 11 September 2003 Resolved
Prove compliance with company drug testing program.
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 26 September 2003
Resolution: Owner proved master and crew to be in compliance with company drug testing program.
Construction/Loadline › Hull
Issued 11 September 2003 Resolved
Properly repair broken weld, stbd side, second longitudinal from deck. LEGACY COMPONENT DESC: Longitudinal Frame
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 26 September 2003
Resolution: Owner properly repaired broken weld, stbd side, second longitudinal from deck.
Construction/Loadline › Hull
Issued 8 September 2003 Resolved
Properly repair broken weld transom, port side, first stiffener and crossbeam. LEGACY COMPONENT DESC: Stiffener
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 26 September 2003
Resolution: Owner properly repaired broken weld transom, port side, first stiffener and crossbeam.
Construction/Loadline › Hull
Issued 8 September 2003 Resolved
Make proper repairs to port stern rail thru deck mount.
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 26 September 2003
Resolution: Owner made proper repairs to port stern rail thru deck mount.
Navigation › Piloting/Steering
Issued 8 September 2003 Resolved
Properly install codder pin on steering ram.
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 26 September 2003
Resolution: Owner properly installed codder pin on steering ram.
Engineering › Sea-water System (primary cooling)
Issued 8 September 2003 Resolved
Properly replace port engine raw water discharge hose from transmission cooler. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 25 September 2003
Resolved 26 September 2003
Resolution: Owner properly replaced port engine raw water discharge hose from transmission cooler.
Construction/Loadline › Hull
Issued 14 August 2003 Resolved
Vsl master or owner identified three cracks in bottom plate. [name withheld] verified cracks and oversaw proper repairs. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 August 2003
Resolved 14 August 2003
Resolution: [name withheld] witnessed vaccum box test (3) on the three identified cracks.
Fire Fighting › Fixed Fire Detection System
Issued 20 September 2002 Resolved
Prove proper operation of E/R fixed fire fighting system IAW 46CFR181.410 (automated engine shut down not installed.) LEGACY COMPONENT DESC: Control Panel
Condition: Improper Installation
Due 15 October 2002
Resolved 8 October 2002
Resolution: Owner/Operator proved proper operation of E/R fixed fire fighting system (i.e., audiable alarm, visual alarm, w/ automatic shutdowns and reset capabilities.
Fire Fighting › Ventilation Systems
Issued 30 August 2002 Resolved
Prove proper operation of E/R ventilation shut down (closures) LEGACY COMPONENT DESC: Ducts
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2002
Resolved 20 September 2002
Resolution: Operator added a mechanical device consisting of a bolt and wing nut for manual shut off control.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 30 August 2002 Resolved
Prove proper operation of E/R fixed fire fighting system IAW 46 CFR 181.410 ( automatic engine shutdown not installed)
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2002
Resolved 20 September 2002
Resolution: Operator proved proper operation of E/R fixed fire fighting system and provided paper work of installation from Coastal Fire Systems. [phone withheld]
Construction/Loadline › Markings
Issued 30 August 2002 Resolved
Remove incorrect name from stern of vesel
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2002
Resolved 20 September 2002
Resolution: Owner removed incorrect name from stern of vessel.
Engineering › Bilge Water Management System
Issued 30 August 2002 Resolved
Prove proper operation of all high level bilge alarms
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2002
Resolved 20 September 2002
Resolution: Tested operation of all high level bilge alarms; all sat.
Engineering › Steering Gear System
Issued 30 August 2002 Resolved
replace both port and starboard rudder posts LEGACY COMPONENT DESC: Rudder Bearing
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2002
Resolved 20 September 2002
Resolution: Owner replaced both port and starboard rudder posts, utilizing a packing material. Tested steering systems, all sat.
Documentation › Certificates/Documents
Issued 30 August 2002 Resolved
Provide proof of current enrollment in DOT drug and alcohol program.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2002
Resolved 20 September 2002
Resolution: Owner provided proof of current enrollment in DOT drug and alcohol program. Drug and alcohol program is through American Drug Testing, Robert B. Dodenhoff (President), [phone withheld].
Communications › Radio Communications
Issued 30 August 2002 Resolved
Provide current EPIRB Hydrostatic release LEGACY COMPONENT DESC: EPIRB
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2002
Resolved 20 September 2002
Resolution: Current EPIRB Hydrostatic release was provided. Date of expiration is 5/03.
Communications › Alarms/Indicators
Issued 30 August 2002 Resolved
Provide audible High level bilge alarm LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2002
Resolved 20 September 2002
Resolution: Operator installed new alarms that were extremely loud.
Communications › Radio Communications
Issued 30 August 2002 Resolved
Provide proof of current EPIRB registration. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2002
Resolved 20 September 2002
Resolution: Owner provided proof of current EPIRB registration. Date of expiration 9/30/04
Electrical
Issued 17 July 2002 Resolved
Provide a blank on the pilot house electrical panel LEGACY COMPONENT DESC: ELECTRICAL PANEL
Condition: Unknown
Due 24 July 2002
Resolved 18 July 2002
Resolution: Provided meter on
Lifesaving › Lifejacket/PFD (General)
Issued 17 July 2002 Resolved
Properly install a PFD donning placard.
Condition: Unknown
Due 24 July 2002
Resolved 18 July 2002
Resolution: Completed
Navigation
Issued 17 July 2002 Resolved
Provide current charts for Charleston Harbor. LEGACY COMPONENT DESC: Missing Charleston charts
Condition: Unknown
Due 24 July 2002
Resolved 18 July 2002
Resolution: Completed
Operations/Management › Drug and Alcohol Testing
Issued 17 July 2002 Resolved
Provide documentation that the vessel crew are enrolled in a Coast Guard approved Drug and Alcohol program. LEGACY COMPONENT DESC: Employee Coverage
Condition: Unknown
Due 24 July 2002
Resolved 18 July 2002
Construction/Loadline › Markings
Issued 17 July 2002 Resolved
Place the correct name on the vessel. LEGACY COMPONENT DESC: Vessel Name/Home Port
Due 24 July 2002
Resolved 18 July 2002
Resolution: Proper name painted on vsl
Lifesaving
Issued 23 November 2001 Resolved
NOTIFY [name withheld] A NEW TO ZONE INSPECTION PRIOR TO CARRYING PASSENGERS IN THEIR ZONE.
Condition: Unknown
Due 23 December 2001
Resolved 17 July 2002
Electrical
Issued 23 November 2001 Resolved
PROVIDE FREQUENCY METER FOR AC ELECTRICAL SYSTEM.
Condition: Unknown
Due 23 December 2001
Resolved 17 July 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.