PICOCAT

PICOCAT is a 1998 passenger vessel (uninspected). The Coast Guard has recorded 20 inspections since 1998, most recently in September 2017, along with 21 deficiencies — 2 with no resolution recorded — and 1 casualty investigation in 2017.

Records from 1998 to 2017. Most recent: inspection, 6 September 2017.

Built
1998
Last inspected
6 September 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH5542
484725
Flag
UNITED STATES
366761760, 366901180 (licence lapsed)
Maury page id
psix-484725

Inspections, by type

…with no type recorded3
…past their stated due date2
Years with a record 11 calendar years (1998–2017)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it6 - Simplified, Gross Ton
5 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB4684MMSI 366901180 · expired · compulsorily equipped · granted 11 July 2003, cancelled 14 September 2013
WCY8837MMSI 366761760 · expired · compulsorily equipped · granted 12 February 1999, cancelled 18 April 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 20

6 September 2017 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6624667
3 October 2016 Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6013981
5 October 2014 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5018288
9 May 2014 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4854031
31 May 2006 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2666497
16 December 2004 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2265567
22 September 2004 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2201955
6 November 2003 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1943348
29 September 2003 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1916083
26 September 2002 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1683150
12 September 2002 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1673674
1 February 2002 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1485514
8 March 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1060212
12 February 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1461358
5 October 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1054958
27 September 2000 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1458799
23 February 2000 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1454805
7 February 1999 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1126212
7 February 1999 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1432064
9 July 1998 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 793904

Deficiency record · 21

Construction/Loadline › Hull › Bottom Plating
Issued 3 October 2016 Resolved
Bottom plating unavailable for inspection on port hull due to fresh paint. Remove paint on forward section of port hull to facilitate inspection.
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 18 November 2016
Resolution: Report provided.
Construction/Loadline › Hull › Bottom Plating
Issued 3 October 2016 Resolved
Remove salt, scale, and water from interior of both hulls to facilitate inspection.
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 18 November 2016
Resolution: Vessel removed paint.
Construction/Loadline › Hull › Bottom Plating
Issued 3 October 2016 Resolved
Observed excessive pitting on forward section of both hulls and stern bottom plating of starboard hull. Provide repair proposal and/or gauge report.
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 18 November 2016
Resolution: Vessel removed water and scale.
Construction/Loadline › Hull › Bottom Plating
Issued 3 October 2016 Resolved
After removing scale/salt/water, provide repair proposal to repair internal pitting in both hulls.
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 28 November 2016
Resolution: Vessel provided remapir proposal and cropped and renewed pitted areas.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 October 2016 Resolved
Repair hole through port side of collision bulkhead.
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 28 November 2016
Resolution: Vessel made insert into hole.
Construction/Loadline › Structures › Deck Plating
Issued 3 October 2016 Resolved
Repair hole in stern deck.
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 28 November 2016
Resolution: Vessel patched hole.
Construction/Loadline › Hull › Weld
Issued 3 October 2016 Resolved
Hose test all new hull welds. Marine Inspector observed hull to deck welds and new through hull penetration mountings with excessive porosity. Conduct NDT to demonstrate watertight integrity of welds.
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 28 November 2016
Resolution: Hose tests and dye pentetrant testing completed as appropriate.
Construction/Loadline › Hull › Side Shell
Issued 3 October 2016 Resolved
Remove wiring to stern lighting penetrating hull.
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 28 November 2016
Resolution: Wiring removed and holes plugged.
Construction/Loadline › Hull › Hull Plating
Issued 18 June 2014 No resolution recorded
Provide report from "Corrosion Specialist" in regards to the current pitting of interior bottom hull plating within port and stbd hulls.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2014 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 May 2014 No resolution recorded
Provide Electrical "AS BUILT" drawings and submit to USCG Marine Safety Center for review and approval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2014 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2014 Resolved
Remove all water from bilges, pressure wash interior bottom plating with fresh water, dry and make available for further inspection due to excessive pitting of bottom plating, port and stbd hulls.
Action required: 705 - Other - as specified
Due 9 May 2014
Resolved 18 June 2014
Construction/Loadline › Hull › Hull Plating
Issued 9 May 2014 Resolved
Remove fractured hull plate coating in way of port bow to allow further inspection of hull plate.
Action required: 705 - Other - as specified
Due 9 May 2014
Resolved 18 June 2014
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 29 September 2003 Resolved
Verify that fixed fire fighting system for starboard engine room is correctly sized.
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 7 November 2003
Resolution: Reviewed with MSO Tampa ACID calcs from original plan review case and compared to exisitng dimensions, all sat.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 29 September 2003 Resolved
Demonstrate that installed fixed firefighting system meets CG regulations per 46CFR182.420 and label override toggle switches.
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 7 November 2003
Resolution: System meets intent of regs, will add special note to install CG approved system when existing system becomes unserviceable.
Communications › Alarms/Indicators
Issued 29 September 2003 Resolved
Demonstrate proper operation of high water bilge alarm in starboard fresh water tank void. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 7 November 2003
Resolution: Tested alarm, all sat.
Construction/Loadline › Structures
Issued 12 September 2002 Resolved
PROPERLY FILL 1/4" DRILLED HOLE IN STARBOARD COLLISION BULKHEAD. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 12 October 2002
Resolved 26 September 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 September 2002 Resolved
REMOVE OIL FROM BOTH ENGINEROOM BILGES/REPAIR OIL LEAKS ON ENGINES AS REQUIRED.
Due 12 October 2002
Resolved 26 September 2002
Fire Fighting
Issued 12 February 2001 Resolved
SERVICE ALL FIXED FIRE FIGHTING SYSTEMS.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Documentation
Issued 12 February 2001 Resolved
PROVIDE A FCC MARINE RADIO OPERATORS PERMIT.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Documentation
Issued 12 February 2001 Resolved
PROVIDE SERVICE CERTIFICATE FOR FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Engineering
Issued 27 September 2000 Resolved
REPLACE/RECONDITION STARBOARD PROP
Condition: Unknown
Due 6 October 2000
Resolved 6 October 2000

Casualty record · 1

6 September 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6624667
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.