MATT'S CAT is a 1998 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in October 2025, along with 66 deficiencies and 3 casualty investigations between 2007 and 2017.

Records from 2007 to 2025. Most recent: inspection, 2 October 2025.

Built
1998
Last inspected
2 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 October 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF3469
484726
Flag
UNITED STATES
Maury page id
psix-484726

Documentation record

Registered dimensions (L × B × D)38.2 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 12 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENCHMARK BOATS INC · STUART FL, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeSail (Faired Keel)
Hull configurationTwin Hull
Hailing portHUMACAO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

2 October 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8245225
7 August 2025 Deficiency Check · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8167297
30 September 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8012994
17 October 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7810082
26 September 2023 Drydock Exam · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7780646
6 September 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7548536
6 October 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7326950
1 September 2021 Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7300978
8 September 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7053217
11 October 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6826803
2 October 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6825264
4 October 2018 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6554920
31 October 2017 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6298088
11 October 2017 Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6286847
20 September 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6289283
22 September 2016 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6007062
25 January 2016 Deficiency Check · Deadweight Survey · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5922425

Deficiency record · 66

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 October 2025 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Provide a servicing certificate, and a servicing report detailing what type of service and tests were conducted on the pre-engineerd CO2 gas fire extinguishing system. 46 CFR 176.810
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 10 October 2025
Resolution: Evidence of certificate of servicing and report was provided.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 2 October 2025 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. Drills are not being recorded in the log following the above format as required above. 46 CFR 185.524
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 10 October 2025
Resolution: Proper drill formatting was followed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 October 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority.(b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Vessel is missing tide tables, current tables, light list and coast pilot publications. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 10 October 2025
Resolution: Publications were placed on board.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 2 October 2025 Resolved
An Employment Assiatnce Program (EAP) training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Provide evidence of training for owner/captain (Supervisory), and crewmembers (non-supervisory), and provide evidence of training to the USCG. 46 CFR 16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2025
Resolved 15 October 2025
Resolution: Evidence of training has been provided for both supervisory and non-supervisory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2025 Resolved
Piping, including valves, pipe fittings and flanges, the temperature of which exceeds 150 degrees Fahrenheit must be suitably insulated where necessary to prevent injuries. The lagging on the exhaust hose on the port side engine was severely deteriorated and no longer maintained its original integrity. Replace the lagging to the satisfaction of the marine inspector.
Action required: 705 - Other - as specified
Resolved 2 October 2025
Resolution: Corrected during annual exam.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 August 2025 Resolved
Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q of this chapter. The insulation in generator compartment and both the port and starboard side engine compartments had missing pieces of insulation. Replace the insulation in the three compartments to the satisfaction of the marine inspector.
Action required: 705 - Other - as specified
Resolved 2 October 2025
Resolution: Other: Clear during next annual exam. Witness to be in good condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 August 2025 Resolved
A hatch exposed to the weather must be watertight. All the hatches on the main deck allowed water to ingress due to gaps on the gaskets. Replace all of the gaskets on all of the hatches to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 2 October 2025
Resolution: Other: Clear during next annual exam. Found correct.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 September 2024 Resolved
harts and nautical publications.(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Update Charts, Tide Tables and coast pilot to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2024
Resolved 25 October 2024
Resolution: Updates were made.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 September 2024 Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Grab line found deteriorated and broke when inspecting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2024
Resolved 25 October 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 September 2024 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Visual indicator inoperable at lower control station.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2024
Resolved 25 October 2024
Resolution: Light was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 30 September 2024 Resolved
The master of the vessel shall ensure that:(a) Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative;(b) The EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner; and(c) The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Captain did not have monthly test logged.
Action required: 10 - Deficiency Rectified
Resolved 30 September 2024
Resolution: Conducted the monthly test of EPIRB.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 October 2023 Resolved
46 CFR 181.420 (a) (3) The installed fixed fire system did not secure the port engine when testing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 October 2023
Resolved 18 October 2023
Resolution: Repairs were made to the fire system and a operational test was witnessed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 October 2023 Resolved
46 CFR 182.530 (a) On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm most be provided at the operating station to indicate high water level. The port aft bile alarm failed to operate at the fly bridge; fly bridge is lacking visual alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2023
Resolved 30 October 2023
Resolution: Tested bilge alarms and visual and audible alarm were present at the fly bridge.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 October 2023 Resolved
46 CFR 184.402 Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Compass is difficult to read due to uv damage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2023
Resolved 30 October 2023
Resolution: Compass was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 October 2023 Resolved
46 cfr 183.200 electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2023
Resolved 18 October 2023
Resolution: Wire was properly secured.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 September 2022 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have a means to reset devices used to automatically shut down ventilation systems and engines as required. The pre-engineered fixed gas system was unable to be reset at the operating station after manually activating the shut down inside the machinery space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2022 Resolved
Shutoff valves must be fitted in the fuel supply lines and installed so as to close against the fuel flow and must be manually operable from outside the compartment. The starboard emergency fuel shutoff valve was unable to be closed due to a cable restriction inside the machinery space.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 September 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. The visual indicator for the port mid bilge high water level alarm was not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2022
Resolved 21 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 September 2022 Resolved
Each item of survival craft equipment must be of good quality and efficient for the purpose it is intended to serve. Lifefloat painters must meet the following specifications: (i) The painter must be at least 100 feet in length, but not less than 3 times the distance between the deck where the life float or buoyant apparatus it serves is stowed and the lowest load waterline of the vessel; (ii) Have a breaking strength of at least 1,500 pounds; (iii) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light; and (iv) Be stowed in such a way that it runs out freely when the life float floats away from a sinking vessel. The painter currently attached to the lifefloat must be replaced due to UV light deterioration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2022
Resolved 21 September 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 September 2022 Resolved
On each container for life jackets, the number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers at least 2 inches high. The stowage containers for the adult and child life jackets must be marked in accordance with the regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2022
Resolved 21 September 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 September 2021 Resolved
Marine employers must ensure that they and their crew members meet the requirements of a drug and alcohol detection program. Employers are responsible for all the actions of their officials, representatives in carrying out the requirements of a drug and alcohol program in all its parts and requirements. Vessel licensed captain failed upon asking to demonstrate knowledge and proficiency in: a. implementation and required testing time frame following a marine casualty, b. implementation of an Employment Assistance Program, c. not able to mention an approved testing facility as designated by its maritime consortium. d. did not have available any means to conduct an alcohol testing device following a marine casualty, e. failed in provide evidence of drug and alcohol training conducted for both supervisory and nonsupervisory personnel. 46CFR16.203
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2021
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 1 September 2021 Resolved
Survival craft must be in good quality, and efficient for the purpose of it is intended to serve. Lifefloat was found to have fractures and large areas of exiting repairs. Replace exiting with a USCG approve lifefloat. 46 CFR180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 7 January 2022
Resolution: Lifefloat has been delivered to vessel owner after a long timed delivery due to COVID afecting the delivery chain.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 September 2021 Resolved
Each portable fire extinguisher on board a vessel must be of an approved type. Vessel was found to have two plastic made, 10-B:C portable fire extinguishers that were passed due their 6 years manufacturing date and were found to be still in service on board the vessel in accordance with NFPA code, incorporated by reference. Replace with new and USCG/NFPA approved portable fire extinguishers. 46 CFR 181.500/ NFPA 10.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2021
Resolution: Two new 10 B:C portable fire extinguishers of an approved type have been placed in service on board the vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 September 2021 Resolved
A vessel must carry either a first-aid kit approved under the approval series 160.041 or a kit with equivalent contents in a suitable watertight container marked "First-Aid Kit". Vessel was found to have missing and expired items that required. Provide an approved type first-aid kit. 46 CFR184.710.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2021
Resolution: A new approved kit under series 160.041 first-aid kit was placed on board for service. Markings on the watertight containers displayed expiration date YR2022 and 160.041 approval number.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 September 2021 Resolved
A vessel must carry adequate and up-to-date: updated nautical chart, Coast pilot, light list, tide and current tables. Extracts from these publications for the area to be transited may be provided instead of the complete publication. Vessel existing publication on board were either missing or dated on YR2017. Provide up-to-date publications or extracts as required by CFR. 46CFR1084.420.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 27 September 2021
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 September 2021 Resolved
EPIRB must be tested monthly and test shall be logged or otherwise documented. USCG Marine Inspector found that the EPIRB is not being tested monthly and test not being logged. Conduct an EPIRB testing each month and log it for the satisfaction of USCG Marine Inspector. 46 CFR185.728
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 14 September 2021
Resolution: Enty was found on one of vessel logs that an EPIRB Testing was conducted on August 2021. This log was not on board during the COI exam, but was available during the Deficiency Check.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 September 2021 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include date of training, a general description of the training topics. Exiting crew drill and training logged was found not to have current dates, and several entries were found to have dates for Yrs 2007, and 2008. Provide a current drills and training log, and carry out training in accordance with the CFR. 46CFR185.420 (c).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 14 September 2021
Resolution: An entry with crew training in MOB and Fire was found on a vessel log that was not available during COI exam, but was availabe during the deficiency check exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 September 2021 Resolved
Gauges to indicate lubrication oil pressure must be provided for all propulsion engines. The lubrication oil pressure located in the lower operating station for the starboard side main diesel engine was found not operable. Demonstrate proper operation of oil pressure gauge. 46CFR182.410(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 14 September 2021
Resolution: The lubrication gaguge was found to be fully operational.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 September 2021 Resolved
Master shall keep a correct and written passenger count and shall be available to USCG upon request. No passenger count was being kept documented and not provided, Conduct passenger count as required by CFR. 46CFR185.504.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 14 September 2021
Resolution: Master provided electronic evidence that passenger count was being conducted and kept ashore.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 September 2021 Resolved
Fire fighting and man over board drills shall be logged or documented for review of the USCG upon request. The drill shall include date of drill and general description of scenario. Conduct drills and provide drill logs for the satisfaction of USCG. 46CFR185.524
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 14 September 2021
Resolution: An entry was found on a vessel log that was not availabe during the COI but was available during the deficiency check.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 September 2021 Resolved
A visual an audible alarm must be provided at the operating station to indicate high water bilge level. The bilge audio alarm was inoperable in both starboard side steering compartment and port side forward compartment. Prove proper operation of these audible alarms. 46CFR185.530.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 27 September 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 September 2021 Resolved
Vessel must be equipped with at least two operable portable battery lights. One must be located at the operating station and the other at the access to the propulsion machinery. One portable light was inoperable and none of the portable lights were found installed in accordance with the regulation. 46CFR183.430.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 14 September 2021
Resolution: Two portable lights were found fully operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 September 2021 Resolved
A hatch exposed to the weather must be watertight and be attached to the hatch frame or coaming by hinges, captive chains or other devices of strength to prevent its loss. Both port & stbd hatches aren't secured. Properly secure hatches according with requirements. 46 CFR179.360.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 27 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 September 2021 Resolved
Vessels of more than 26 feet but not more than 65 feet must carry a minimum of one life ring of not less than 24 inches in diameter. Life ring on board was found deteriorated. Replace the life ring in accordance with the regulation. 46CFR180.70(2).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 14 September 2021
Resolution: A new 24" approved type lifering was found to be installed on board vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 September 2021 Resolved
Placard containing instructions for the donning and use of life jackets must be posted. Current placard displays a different life jacket model ([name withheld]), different from the ones carried on board. Replace current donning placard with the model currently being carried on board. 46CFR185.516.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 14 September 2021
Resolution: PFD donning placard was found to be installed and also of the same model of PFD available on board.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 September 2021 Resolved
At each inspection for certification and at every other inspection, bilges and other spaces may be examined to see that there is no excess of oil, debris, trash or other matter that might create a fire hazard. A large plastic combustible storage bin and a diesel plastic gasoline portable tank were found in the engine room. Remove all combustible materials to prevent fire risks.46CFR176.840.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 27 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 1 September 2021 Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Provide a means easily deployable to close both port & starboard ventilation cowls that is efficient in preventing the exchange of air upon actuation of the pre-engineered fixed fire extinguishing system. 46CFR182.465 (h).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 6 October 2021
Resolution: A new means on how to close ventilation in both port & starboard side of the vessel has been installed and found satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 September 2021 Resolved
All around light means a light showing an unbroken light over an arc of the horizon of 360. Current all around light is installed underneath the flying bridge operating station and incapable of being seen from vessel navigating in the vicinity. All around light must be relocated in a visible location as required by regulation and navigation rules. Vessel is limited to daylight operations only, until deficiency is corrected. 33CFR83.21/83.23/84.03.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 6 October 2021
Resolution: An approved light has been re-intalled in the highest center location above the upper operating station.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 September 2021 Resolved
Stern light means a white light placed as nearly as practicable at the stern showing an unbroken light over an arc of the horizon of 135 degrees and so fixed as to show the light 67.5 degrees from right aft on each side of the vessel. The stern light is located close to mid ship and underneath the operating station, close to the all around light. 33CFR83.21/84.03.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 27 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 September 2021 Resolved
The rules concerning shapes shall be complied with by day. Vessel was found not having the following day shapes: a. one diamond shape; b. one ball shape. 33CFR83.20.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2021
Resolved 1 October 2021
Resolution: Vessel was provided with day shapes placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2020 Resolved
Batteries expired and cracked
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 21 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 September 2020 Resolved
Life float has unauthorized repairs
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2020
Resolved 16 September 2020
Resolution: Silicon 5200 Exelelon is acceptable
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 October 2019 Resolved
1.Each ring life buoy must be marked with Type II retroflective material. The ring life buoy needs to have suitable type II retroflective tape IAW 46 CFR 185.604.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 14 October 2019
Resolution: CLEARED
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 11 October 2019 Resolved
2.Each pendant for buoyant apparatus must be secured by not more than two turns of twine. Pendants are currently sectured by zip ties.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 October 2019
Resolved 27 October 2019
Resolution: Cleared.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 October 2018 Resolved
A vessel must comply with applicable requirements for radio installations as set forth in 47 CFR 80. Vessel must have a radio telephony certificate, must connect GPS to VHF Radio and must enter MMSI Number in VHF Radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2019
Resolution: Vessel provided proof of radio/GPS connection, mmsi number and radiotelephony certificate.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 4 October 2018 Resolved
Operator must secure MSD in a manner which prevents discharge of treated or untreated sewage. Vessel must secure sewage overboard discharge valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2019
Resolution: Owner added a new valve and zipped tied it in the closed position.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 October 2018 Resolved
A vessel on a Limited Coastwise Route must have 6 hand red flares and six orange smoke signals or any combination thereof. Vessel only has on board 8 red hand distress signals. Provide either 4 additional red hand flares or 4 orange smoke signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 October 2018
Resolution: Owner sent in photos of new red hand flares.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 October 2018 Resolved
General purpose resin may be used instead of fire retardant resin if non-combustible panels/insulation is installed in machinery space boundaries with accommodation spaces. Stbd side machinery space does not have non-combustible insulation installed. Install by next dry dock.
Action required: 705 - Other - as specified
Resolved 15 March 2019
Resolution: Non-combustible insulation was installed on the stbd side machinery space.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 October 2017 Resolved
Prove proper operation of VHF Radio
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 7 November 2017
Electrical › Electric Supply System (service) › Cable
Issued 31 October 2017 Resolved
Install metal clamps to support wiring in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 7 November 2017
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 31 October 2017 Resolved
Replace battery in smoke detector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 7 November 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 October 2017 Resolved
Display all pages of the COI
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 16 November 2017
Communications › Radio Communications › EPIRB
Issued 31 October 2017 Resolved
Replace the hydrostatic release for EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 7 November 2017
Lifesaving › Lifefloat › Serviceable
Issued 31 October 2017 Resolved
Fix cracks on life float IAW manufacturer
Action required: 705 - Other - as specified
Due 22 November 2017
Resolved 16 November 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 October 2017 Resolved
Replace lifeline on life ring buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 16 November 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 31 October 2017 Resolved
Provide visual and audio alarm at operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2017
Resolved 7 November 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 September 2016 Resolved
Provide a means of alcohol testing onboard. 46 CFR 4.06-15.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2016
Resolution: New alcohol swabs were purchased and placed on board.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 22 September 2016 Resolved
Provide arrangements for post-casualty testing. 46 CFR 16.240.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2016
Resolution: The consortium informed the owner/operator/captain where he and/or the crew should go for post-casualty testing.
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 September 2016 Resolved
Prove remote operation of fuel shut-off valve safely. 182.455(b)(4).
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 17 October 2016
Resolution: installed remote fuel shutoff system.
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 September 2016 Resolved
Provide access to fuel shut-off valve. 182.455(b)(4).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2016
Resolution: Operator provided access to the valve by hammering the stuck screw-on cover.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 September 2016 Resolved
Prove proper operation of starboard navigation light. Vessel is restricted from night operations. 33 CFR 84.
Action required: 705 - Other - as specified
Resolved 23 September 2016
Resolution: The operator removed and cleaned the navigation light and reenergized the assembly in the presence of an attending inspector with satisfactory results.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 22 September 2016 Resolved
Install gasket material on aft deck hatches. 46 CFR 179.360(a)(2).
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 5 October 2016
Resolution: Verified new gasket material was installed.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 22 September 2016 Resolved
Prove operation of RPM gauge at 2nd operating station. 46 CFR 182.410(b).
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 5 October 2016
Resolution: A new RPM gauge was installed and tested.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 22 September 2016 Resolved
Update Coast Pilot/Nav. Rules. 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 5 October 2016
Resolution: Updated publications were purchased and brought on board.
Communications › Audible Communications › Horn/Whistle
Issued 22 September 2016 Resolved
Provide sound signal audible for half a mile. 33 CFR 86.01, Table 86.01(c).
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 5 October 2016
Resolution: An airhorn certified for .5 mile audible range was purchased and provided on board.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 22 September 2016 Resolved
Correct DAPI audit results. See audit form.
Action required: 705 - Other - as specified
Due 20 October 2016
Resolved 17 October 2016
Resolution: provided.

Casualty record · 3

5 August 2007Routine · role: Involved in a Marine Casualty · activity 3030820
6 April 2015Routine · role: Involved in a Marine Casualty · activity 5102003
20 September 2017Routine · role: Involved in a Marine Casualty · activity 6289283
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.