MAURY USCG vessel records
← All vessels

VIKING SUPERSTAR

VIKING SUPERSTAR is a 1975 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in May 2026, along with 83 deficiencies, 1 operational control and 2 casualty investigations between 2001 and 2010.

Records from 2001 to 2026. Most recent: inspection, 21 May 2026.

Built
1975
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8950940
WDI5096
Flag
UNITED STATES
Maury page id
psix-48474

Documentation record

Registered dimensions (L × B × D)101.0 ft × 24.3 ft × 9.5 ft
Registered tonnagegross 92 / net 63
ITC dimensions (L × B × D)101.0 ft × 24.3 ft × 9.5 ft
ITC tonnagegross 188 / net 90
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMONTAUK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
188 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
90 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

21 May 2026 Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8359325
22 May 2025 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8140766
30 April 2025 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8126269
16 January 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8060035
2 May 2024 Deficiency Check · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7904797
31 May 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7678676
7 February 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7639603
9 January 2023 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7613775
19 May 2022 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7454347
6 December 2021 Examination of Repairs · Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7363309
12 July 2021 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7257108
28 May 2021 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7078339
4 May 2021 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7175964
26 January 2021 Plan Review "T" Boat
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7130982
30 January 2020 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6902193
18 November 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6841868
10 October 2019 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6831938
26 April 2019 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6663342
4 February 2019 Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6656486
20 November 2018 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6571773
13 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6539769
8 November 2017 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6294345
28 September 2017 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6277205
1 February 2017 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6080316
14 November 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6040985
6 June 2016 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5899187
23 May 2016 Drydock Extension
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5884199

Deficiency record · 83

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 May 2025 Resolved
Replace/repair water light lines on L/F lights.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 22 May 2025
Resolution: Corrected prior to the end of the inspection
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 May 2025 Resolved
repair or replace 2 of the water lights for L/F's
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 22 May 2025
Resolution: Item corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 January 2025 Resolved
Remove excess electrical cord for prior bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 29 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 January 2025 Resolved
Remove the wasted bilge pipe suction coupling for further inspection in the tank void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 29 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 January 2025 Resolved
Remove the starboard inboard exhaust bellows for further inspection. (to be issued as deficiency following DD)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 January 2025 Resolved
Grind and reweld the marked welds on the rails and bulwarks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 29 April 2025
Resolution: Witnessed approx 12 locations. All SAT.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 January 2025 Resolved
Renew the door knob on the port emergency escape door on the 01 deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 29 April 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 January 2025 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. At fire inspection conducted on 30Jan25 time delay and audible siren in engine room failed to operate as designed. Vessel is authorized to make one time transit to home berth. Satisfactory operation of installed fire system to be witnessed by an attending Coast Guard Marine Inspector.
Action required: 15 - Rectify deficiencies by next port
Due 15 February 2025
Resolved 30 April 2025
Resolution: Witnessed. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 May 2024 Resolved
One of the vessels liferafts' waterlights was inop. restricted to daylight ops.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2024
Resolved 14 May 2024
Resolution: Battery replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 May 2024 Resolved
The fire pumps' gauge was inop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 14 May 2024
Resolution: Replaced gauge and tested. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2023 Resolved
An electric water heater is also acceptable if it is listed under UL174, UL1453 or other standard specified by the Commandant. On board Water heater is listed as UL 786H. Replace water heater with a compliant unit or provide evidence of historical acceptance by the Commandant. Replaced. Proivded documentation that heater meets regulations prior to usage.
Action required: 705 - Other - as specified
Due 10 February 2023
Resolved 7 February 2023
Resolution: MI attended vessel and noted the installation of a satisfactory UL approved Hot water Heater
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2023 Resolved
When the exhaust cooling water system is separate from the engine cooling water system a suitable warning device, visible or audible must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system. Prior to departure from dry dock and repairs to the system, operationally test generator exhaust water cooling alarm to the satisfaction of an attending Marine Inspector. Awaiting parts. Vessel authorized to make a one time transit to homeport in Montauk, NY. Vessel required to make continuous rounds of engine room during transit.
Action required: 705 - Other - as specified
Due 9 January 2023
Resolved 6 March 2023
Resolution: MI recieved video proof of satisfactory operation of alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2021 Resolved
Provide programed set points and parameters on the new engines...ie High jacket water temp alarm set points etc (and enabled safeties such as engine derate or shutdowns) to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2021
Resolved 25 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2021 Resolved
Conduct sea trials and testing of the new engines to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2021
Resolved 25 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2021 Resolved
Identified PFE;NFPA UL 40 B:C/ 4A for the passenger compartment with the gauge needle reading in the discharged zone. Company representative [name withheld] was able to provide a new and serviced PFE of the same rating.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2021 Resolved
Identified PFE;NFPA UL 40 B:C/ 4A for the passenger compartment with the gauge needle reading in the discharged zone. Company representative [name withheld] was able to provide a new and serviced PFE of the same rating.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2021 Resolved
Identified dead end wiring for lighting on the PORT side by the pilot house cat walk. Issued requirement to remove of secure dead end wiring where risk of shock would exist if energized.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
Resolution: Dead end wiring removed and the port where the wiring came through was closed and secured using elec. cover
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2021 Resolved
Identified on the STBD side in the passenger cabin, at the forward entry way a plug hanging from wires where terminals were exposed posing risk of electrical shock.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
Resolution: Plug removed, Wires were capped off and a cover was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 July 2021 Resolved
Identified covers over all of the vessel's life floats provided IAW the COI. This cover would have either prevented or at a minimum hindered float free deployment. Issued requirement to remove covers to allow for float free deployment
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
Resolution: Covers were removed and life floats were set up in a float free condition when I departed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 July 2021 Resolved
EPIRB was kept in the vessel's pilot house and not set up for float free deployment. The vessel operator stated he kept the equipment there and in case of emergency he would take it. Additionally he stated stowed IAW regulations the EPIRB would blow off.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
Resolution: Installed the EPIRB in the case as required with the hydrostatic release and designed for float free operation.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 May 2021 Resolved
Remove temporary lighting above stbd mde.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2021
Resolved 28 May 2021
Resolution: Fixture was removed
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 May 2021 Resolved
Install capture device on steering hatch cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 28 May 2021
Resolution: Corrected on the spot
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2021 Resolved
Correctly label upperdeck capacity.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 28 May 2021
Resolution: Corrected on the spot
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 May 2021 Resolved
An inspection for renewal of a COI is conducted to determine if the vessel is in satisfactory condition. COI is expired. Conduct renewal inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2021
Resolution: MI attended vessel and conducted a satisfacory COI
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 January 2020 Resolved
Repair or replace life floats on the 02 deck. Life floats grab lines and outer shells were identified as "dry rotted" due to excessive sun damage and exposure to the elements. The life floats in service dates was December 2004. Life Floats are not IAW Q specs 46 CFR 160.027-2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2020
Resolved 7 April 2020
Resolution: O/O replaced 07 life floats. 1 of the existing lifefloats remains servicable and 7 new were added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 January 2020 Resolved
6 adult life jackets were identified in unserviceable condition. All 06 were Kapok type I, where the closed cell was discovered compromised. Destroyed and removed the deficient PFDs. PFDs were carried in excess to regulation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 January 2020
Resolved 30 January 2020
Resolution: PFDs were carried in excess of regulation. PFDs were removed and destroyed. //s// [name withheld], GS-12, USCG
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 30 January 2020 Resolved
Label paddles for the life floats with the vessel's name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed re-labeled paddles for life-floats.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 30 January 2020 Resolved
Identified EPIRB hydrostatic release expired in December 2018. Vessel representative stated he marked the install date on the hydro static release and thought he had 2 years after that date. This was a self marking system used on older hydrostatic releases. Vessel representative replaced the hydrostatic release on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 January 2020
Resolved 30 January 2020
Resolution: New hydro-static release purchased and installed. //s// [name withheld], GS-12, USCG
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
Properly abandon or terminate all dead end wiring. 02 areas identified were where fishing lights have been removed and over the port generator in the machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 7 April 2020
Resolution: Properly abandoned or terminated all dead end wiring.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 30 January 2020 Resolved
Link the MMSI VHF-fm radio to a position source in accordance with 47 CFR 80.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Witnessed MMSI and position information installed on VHF radio.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
Non-conductive matting is required where switchboards are3 operated from. Place or install non conductive matting where the primary switchboard is operated from.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Witnessed newly installed electrical matting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
Secure power cables to the starboard VHF-fm radio using butt end type connectors. VHF-fm radio power wires were secured with screw type connectors.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed approved electrical connections installed in VHF wiring.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
All electrical outlets on weather decks must be watertight. Starboard side outlet is open and exposed to the elements.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed newly installed electrical outlet outside of wheelhouse.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
Re-wire public address speaker on the 2nd deck passenger area. Prove public address system can be operated from the primary operating station and heard in all areas of the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Witnessed approved elecrtrical connections installed on PA speakers.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 January 2020 Resolved
Secure lighting fixture cover in the steering space where the cover is designed to protect the fluorescent tube bulbs (the fixture's diffuser).
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Witnessed light fixture properly secured in laz.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2020 Resolved
Mount the size 6A-120 B:C portable fire extinguisher for the machinery space with an approved bracket.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed fire extinguisher properly mounted in mach space.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 January 2020 Resolved
Install guards for exposed rotating hazards on both generators.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed guards installed on both gen sets.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 November 2019 Resolved
Vessel undergoing dockside maintenance period where life saving, firefighting, main propulsion, electrical and vital systems were found not operational and undergoing maintenance. Make available for inspection all systems and equipment applicable and required prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 30 January 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019 Resolved
Crop and renew wasted bottom plate as marked in lazarette. Starting at aft bulkhead thru fwd bulkhead approximately 18" outboard either side of the keel in laz. Continuing forward into MSD space starting at the aft blkhd crop and renew bottom plate forward to first transverse frame and outboard from keel 3 frame spaces to port and 1 to starboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 22 May 2019
Resolution: Renewed wasted bottom plate as marked in lazarette.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 April 2019 Resolved
Repair cracked weld as marked in port quarter of laz transverse frame.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Repaired cracked weld as marked in port quarter of laz transverse frame.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 26 April 2019 Resolved
Crop and renew wasted metal as marked in MSD space in way of both the port and starboard outboard stern tubes where they penetrate the hull. Starting in the engine room coming thru the fwd bulkhead in aft 4 transverse frame bays on both P/S.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Renewed wasted metal as marked in MSD space in way of both the port and starboard outboard stern tubes.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019 Resolved
Crop and renew wasted metal in engine room as marked at aft bulkhead spanning approximately 1.5 frame bays at 18" by 18".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 22 May 2019
Resolution: Renewed wasted metal in engine room as marked at aft bulkhead spanning approximately 1.5 frame bays at 18" by 18".
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019 Resolved
In the pump room starting approximately 4" aft of the forward bulkhead crop and renew wasted metal as marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 22 May 2019
Resolution: Renewed wasted metal as marked.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019 Resolved
In pump room make clad weld repairs to the 3 pitts indicated forward of the bilge suction manifold and 1 pitt located below what appears to be a previous battery box storage foundation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Witnessed sat clad welds.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 April 2019 Resolved
In Bunk room re-weld cracked frame, 4th frame forward of the aft bulkhead port of keel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Winessed renewed section of frame.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 April 2019 Resolved
In the forward void repair cracked welds on overhead bracket starboard side as marked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 22 May 2019
Resolution: Witnessed weld repairs as marked.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019 Resolved
In fore-peak make clad repair starboard side as marked underneath hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Witnessed sat clad repair.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 20 November 2018 Resolved
46 CFR 182.465(L)- Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Conditions found had security camera wires run through the damper exhaust area that whould have prevented the dampers from closing.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2018
Resolved 30 November 2018
Resolution: Wires were secured to a bulkhead away from the fire damper door allowing for free opening and closing of the fire dampers installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 20 November 2018 Resolved
46 CFR 161.010-2 -Floating electric water light shall meet requirements of ANSI/ UL 1196, where stated (1.4) the product must prevent electric shock or injury. 03 floating electric marker lights attached to the vessel's BAs were found not water tight due to casing hardware missing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 November 2018
Resolved 20 November 2018
Resolution: O/O had spares on hand and spliced the new floating electric marker lights to the BAs IAW 46 CFR 180.175(4).
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 November 2018 Resolved
46 CFR 185.700 - Operational Readiness - survival craft(s) must be in good working order and ready for immediate use. 01 BA on the vessel was found with about a 1x1 " tear in the polyurethane cover.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2018
Resolved 30 November 2018
Resolution: the tear in the BA was repaired using the manufacturer's product to effect such repairs to polyurathane BAs
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 November 2018 Resolved
46 CFR 184.710 - First aid kit found with contents missingand contents expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2018
Resolved 30 November 2018
Resolution: A new first aid kit was purchased and placed on the vessel. All contents were present and unexpired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2018 Resolved
46 CFR 182.530- (a) On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:...2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. Foundthe Engine room and forepeak high water alarms were inoperable; no visual or audible alarms for either space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2018
Resolved 30 November 2018
Resolution: High water alarm wiring for these spaces were checked and repaired. both space high water alarms operate IAW CFR with audio and visual
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
Vsl is broadcasting no IMO #, Vsl is broadcasting greater than expected vessel length, Vsl is broadcasting no static draft information and Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 27 June 2019
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Lifesaving › Lifefloat › Paddle
Issued 13 November 2017 Resolved
Provide 05 lifefloat paddles so that each lifefloat has 02 paddles. 46CFR180.175(d)
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 21 November 2017
Resolution: Provided
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 13 November 2017 Resolved
Repair/Replace fire detection panel in the bridge and prove operation to U.S.C.G. 46CFR181.400(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2017
Resolved 21 November 2017
Resolution: Provided
Engineering › Steering Gear System › Rudder
Issued 13 November 2017 Resolved
Repair/Replace nuts on port side steering platform and find permanent means to secure nuts to bolts. 46CFR176.814
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 21 November 2017
Resolution: Provided
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 November 2017 Resolved
Provide emergency escape light in forward passenger accommodation space. Prior to carrying overnight pax. 46CFR183.432(a)
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 21 November 2017
Resolution: Installed
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 November 2017 Resolved
Clean bilges in the engine room and properly dispose of oily debris. 46CFR176.830(b)
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 21 November 2017
Resolution: Removed
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 13 November 2017 Resolved
Provide instructions and labeling of fixed CO2 system. 46CFR485.612
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 21 November 2017
Resolution: Provided
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 November 2017 Resolved
Provide smoke detector in accommodation space (UL 217). Prior to carrying overnight pax. 46CFR181.450(a)
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 21 November 2017
Resolution: Installed
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 13 November 2017 Resolved
Replace port engine exhaust due to epoxy patch. 46CFR182.430(b)
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 21 November 2017
Resolution: Replaced
Operations/Management › Vessel Activity › Other
Issued 14 November 2016 Resolved
Credit drydock never completed. Vessel must complete credit drydock prior to any commercial operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2016
Resolved 22 February 2017
Resolution: MI attended vessel, cleared necessary requirements to credit Hull Exam.
Communications › Radio Communications › EPIRB
Issued 14 November 2016 Resolved
EPIRB registration expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement had been completed.
Communications › Radio Communications › EPIRB
Issued 14 November 2016 Resolved
EPIRB battery expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Lifesaving › Lifefloat › Retroreflective Material
Issued 14 November 2016 Resolved
Renew all retro tape on all lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2017
Resolution: Cleared [name withheld]
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 14 November 2016 Resolved
Starboard and Port FRP wet elbows water into the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 November 2016 Resolved
Starboard exhaust piping is leaking water. Vessel modified existing exhaust from dry into wet.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Construction/Loadline › Hull › Transverse Frame
Issued 14 November 2016 Resolved
Frame and stiffeners aft of port generator are cracked. Old repairs have failed. Grind and reweld all cracked areas.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 14 November 2016 Resolved
2015 MIS report missing.
Due 14 December 2016
Resolved 15 November 2016
Resolution: Received MIS report.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 June 2016 Resolved
Make temp repair to both MDE exhaust piping, and make avail for inspection w/vessel in the water.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: Temp repair had been made prior to MI attending vessel and permanent repairs were being carried out.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 June 2016 Resolved
Make permanent repairs to MDE exhaust piping. Crop/renew piping.
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Engineering › Fuel Oil Service System › Suction Strainer
Issued 7 June 2016 Resolved
Repair/renew wasted weld on port MDE Strainer.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: witnessed repair
Construction/Loadline › Hull › Weld
Issued 7 June 2016 Resolved
Repair cracked weld on fwd entrance way (stbd side).
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: Witnessed repair
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 June 2016 Resolved
Remove or repair outlet on stbd side of pilot house.
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Lifesaving › Lifefloat › Serviceable
Issued 7 June 2016 Resolved
Perform maintenance on all life floats. Clean
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Construction/Loadline › Hull › Weld
Issued 7 June 2016 Resolved
Clad weld plate port side just fwd of rudder post.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: This requirement had been completed at last dry docking. Found no need for "cladding" anything...
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 7 June 2016 Resolved
Replace both MDE spool/flanges with approved material and make available for inspection in the water. Prior to Credit Dry Dock
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 7 June 2016 Resolved
Replace both outboard MDE spool/flanges with approve material.
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 June 2016 Resolved
Replace hose portside on board MDE muffler. Prior to credit dry dock.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Construction/Loadline › Hull › Transverse Frame
Issued 27 May 2016 Resolved
Drill stop crack in #3 and #4 transverse frame just below the chine in compartment #3. Gouge out weld and reweld. Make avaialble for inspection PTCHE
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Engineering › Bilge Water Management System › Valve
Issued 27 May 2016 Resolved
Repair or replace bilge suction valve in collison compartment.
Due 30 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed. Reach rod was reconnected and a satisfactory test was completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 23 May 2016 Resolved
Remove metal exhaust section ends for inspection on #2 and #3 MDE wet exhaust. All the piping ends shows signes of wasteage (leaking water & sealent added to ends of hoses) PTCHE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed. New piping was being installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 23 May 2016 Resolved
#2 MDE sea suction valve shows signes of wastage. Remove sea vale and spool piece for inspection. PTCHE
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 1 February 2017
Resolution: Spool piece repaired.

Casualty record · 2

8 October 2001Routine · role: Involved in a Marine Casualty · activity 1626098
3 July 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3924255
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

WAVE DANCER (2001). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.