VIKING SUPERSTAR

VIKING SUPERSTAR is a 1975 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1981, most recently in May 2026, along with 127 deficiencies, 1 operational control and 2 casualty investigations between 2001 and 2010.

Records from 1981 to 2026. Most recent: inspection, 21 May 2026.

Built
1975
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8950940 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDI5096
Flag
UNITED STATES
367705130
Maury page id
psix-48474

Inspections, by type

…with no type recorded19
Years with a record 31 calendar years (1981–2026)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)101.0 ft × 24.3 ft × 9.5 ft
Registered tonnagegross 92 / net 63
ITC dimensions (L × B × D)101.0 ft × 24.3 ft × 9.5 ft
ITC tonnagegross 188 / net 90
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTAUK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
188 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
90 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI5096MMSI 367705130 · active · compulsorily equipped · granted 18 September 2025, expires 2 December 2035
WDC7422MMSI 367071160 · expired · compulsorily equipped · granted 12 October 2005, cancelled 12 December 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

21 May 2026 Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8359325
22 May 2025 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8140766
30 April 2025 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8126269
16 January 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8060035
2 May 2024 Deficiency Check · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7904797
31 May 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7678676
7 February 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7639603
9 January 2023 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7613775
19 May 2022 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7454347
6 December 2021 Examination of Repairs · Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7363309
12 July 2021 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7257108
28 May 2021 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7078339
4 May 2021 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7175964
26 January 2021 Plan Review "T" Boat
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7130982
30 January 2020 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6902193
18 November 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6841868
10 October 2019 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6831938
26 April 2019 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6663342
4 February 2019 Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6656486
20 November 2018 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6571773
13 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6539769
8 November 2017 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6294345
28 September 2017 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6277205
1 February 2017 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6080316
14 November 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6040985
6 June 2016 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5899187
23 May 2016 Drydock Extension
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5884199
16 November 2015 Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5764370
14 January 2011 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3926778
30 November 2010 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3900100
9 March 2010 Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3692330
17 December 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3651661
13 April 2009 Damage Survey · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3451853
18 November 2008 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3365250
26 February 2008 Hull Examination · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3153613
26 October 2007 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3086858
3 April 2007 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2901610
19 January 2007 Deficiency Check · Plan Review "T" Boat
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2812421
23 October 2006 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2810756
25 May 2006 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2658401
24 February 2006 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2591506
6 October 2004 Construction Oversight · Deficiency Check · Plan Review "T" Boat · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2307094
8 October 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1626098
7 June 1991 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1240514
5 June 1990 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1244693
1 May 1990 COI Inspection · Drydock Extension
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1215220
2 May 1989 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 892865
19 December 1988 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1039993
9 November 1988 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 891408
12 May 1988 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1352493
15 May 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333776
3 July 1986 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1297023
25 June 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302073
10 April 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 999008
31 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977969
10 May 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1285630
29 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 979883
17 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973490
30 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973489
14 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973543
21 November 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964551
10 August 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967151
8 August 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966839
3 August 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 971407
19 May 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964800
4 May 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 967367
7 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965222
21 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272791
20 May 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278306

Deficiency record · 127

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 May 2025 Resolved
Replace/repair water light lines on L/F lights.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 22 May 2025
Resolution: Corrected prior to the end of the inspection
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 May 2025 Resolved
repair or replace 2 of the water lights for L/F's
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 22 May 2025
Resolution: Item corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 January 2025 Resolved
Remove excess electrical cord for prior bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 29 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 January 2025 Resolved
Remove the wasted bilge pipe suction coupling for further inspection in the tank void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 29 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 January 2025 Resolved
Remove the starboard inboard exhaust bellows for further inspection. (to be issued as deficiency following DD)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 January 2025 Resolved
Grind and reweld the marked welds on the rails and bulwarks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 29 April 2025
Resolution: Witnessed approx 12 locations. All SAT.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 January 2025 Resolved
Renew the door knob on the port emergency escape door on the 01 deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 29 April 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 January 2025 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. At fire inspection conducted on 30Jan25 time delay and audible siren in engine room failed to operate as designed. Vessel is authorized to make one time transit to home berth. Satisfactory operation of installed fire system to be witnessed by an attending Coast Guard Marine Inspector.
Action required: 15 - Rectify deficiencies by next port
Due 15 February 2025
Resolved 30 April 2025
Resolution: Witnessed. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 May 2024 Resolved
One of the vessels liferafts' waterlights was inop. restricted to daylight ops.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2024
Resolved 14 May 2024
Resolution: Battery replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 May 2024 Resolved
The fire pumps' gauge was inop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 14 May 2024
Resolution: Replaced gauge and tested. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2023 Resolved
An electric water heater is also acceptable if it is listed under UL174, UL1453 or other standard specified by the Commandant. On board Water heater is listed as UL 786H. Replace water heater with a compliant unit or provide evidence of historical acceptance by the Commandant. Replaced. Proivded documentation that heater meets regulations prior to usage.
Action required: 705 - Other - as specified
Due 10 February 2023
Resolved 7 February 2023
Resolution: MI attended vessel and noted the installation of a satisfactory UL approved Hot water Heater
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2023 Resolved
When the exhaust cooling water system is separate from the engine cooling water system a suitable warning device, visible or audible must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system. Prior to departure from dry dock and repairs to the system, operationally test generator exhaust water cooling alarm to the satisfaction of an attending Marine Inspector. Awaiting parts. Vessel authorized to make a one time transit to homeport in Montauk, NY. Vessel required to make continuous rounds of engine room during transit.
Action required: 705 - Other - as specified
Due 9 January 2023
Resolved 6 March 2023
Resolution: MI recieved video proof of satisfactory operation of alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2021 Resolved
Provide programed set points and parameters on the new engines...ie High jacket water temp alarm set points etc (and enabled safeties such as engine derate or shutdowns) to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2021
Resolved 25 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2021 Resolved
Conduct sea trials and testing of the new engines to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2021
Resolved 25 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2021 Resolved
Identified PFE;NFPA UL 40 B:C/ 4A for the passenger compartment with the gauge needle reading in the discharged zone. Company representative [name withheld] was able to provide a new and serviced PFE of the same rating.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2021 Resolved
Identified PFE;NFPA UL 40 B:C/ 4A for the passenger compartment with the gauge needle reading in the discharged zone. Company representative [name withheld] was able to provide a new and serviced PFE of the same rating.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2021 Resolved
Identified dead end wiring for lighting on the PORT side by the pilot house cat walk. Issued requirement to remove of secure dead end wiring where risk of shock would exist if energized.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
Resolution: Dead end wiring removed and the port where the wiring came through was closed and secured using elec. cover
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2021 Resolved
Identified on the STBD side in the passenger cabin, at the forward entry way a plug hanging from wires where terminals were exposed posing risk of electrical shock.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
Resolution: Plug removed, Wires were capped off and a cover was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 July 2021 Resolved
Identified covers over all of the vessel's life floats provided IAW the COI. This cover would have either prevented or at a minimum hindered float free deployment. Issued requirement to remove covers to allow for float free deployment
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
Resolution: Covers were removed and life floats were set up in a float free condition when I departed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 July 2021 Resolved
EPIRB was kept in the vessel's pilot house and not set up for float free deployment. The vessel operator stated he kept the equipment there and in case of emergency he would take it. Additionally he stated stowed IAW regulations the EPIRB would blow off.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
Resolution: Installed the EPIRB in the case as required with the hydrostatic release and designed for float free operation.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 May 2021 Resolved
Remove temporary lighting above stbd mde.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2021
Resolved 28 May 2021
Resolution: Fixture was removed
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 May 2021 Resolved
Install capture device on steering hatch cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 28 May 2021
Resolution: Corrected on the spot
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2021 Resolved
Correctly label upperdeck capacity.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 28 May 2021
Resolution: Corrected on the spot
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 May 2021 Resolved
An inspection for renewal of a COI is conducted to determine if the vessel is in satisfactory condition. COI is expired. Conduct renewal inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2021
Resolution: MI attended vessel and conducted a satisfacory COI
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 January 2020 Resolved
Repair or replace life floats on the 02 deck. Life floats grab lines and outer shells were identified as "dry rotted" due to excessive sun damage and exposure to the elements. The life floats in service dates was December 2004. Life Floats are not IAW Q specs 46 CFR 160.027-2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2020
Resolved 7 April 2020
Resolution: O/O replaced 07 life floats. 1 of the existing lifefloats remains servicable and 7 new were added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 January 2020 Resolved
6 adult life jackets were identified in unserviceable condition. All 06 were Kapok type I, where the closed cell was discovered compromised. Destroyed and removed the deficient PFDs. PFDs were carried in excess to regulation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 January 2020
Resolved 30 January 2020
Resolution: PFDs were carried in excess of regulation. PFDs were removed and destroyed. //s// [name withheld], GS-12, USCG
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 30 January 2020 Resolved
Label paddles for the life floats with the vessel's name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed re-labeled paddles for life-floats.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 30 January 2020 Resolved
Identified EPIRB hydrostatic release expired in December 2018. Vessel representative stated he marked the install date on the hydro static release and thought he had 2 years after that date. This was a self marking system used on older hydrostatic releases. Vessel representative replaced the hydrostatic release on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 January 2020
Resolved 30 January 2020
Resolution: New hydro-static release purchased and installed. //s// [name withheld], GS-12, USCG
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
Properly abandon or terminate all dead end wiring. 02 areas identified were where fishing lights have been removed and over the port generator in the machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 7 April 2020
Resolution: Properly abandoned or terminated all dead end wiring.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 30 January 2020 Resolved
Link the MMSI VHF-fm radio to a position source in accordance with 47 CFR 80.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Witnessed MMSI and position information installed on VHF radio.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
Non-conductive matting is required where switchboards are3 operated from. Place or install non conductive matting where the primary switchboard is operated from.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Witnessed newly installed electrical matting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
Secure power cables to the starboard VHF-fm radio using butt end type connectors. VHF-fm radio power wires were secured with screw type connectors.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed approved electrical connections installed in VHF wiring.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
All electrical outlets on weather decks must be watertight. Starboard side outlet is open and exposed to the elements.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed newly installed electrical outlet outside of wheelhouse.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
Re-wire public address speaker on the 2nd deck passenger area. Prove public address system can be operated from the primary operating station and heard in all areas of the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Witnessed approved elecrtrical connections installed on PA speakers.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 January 2020 Resolved
Secure lighting fixture cover in the steering space where the cover is designed to protect the fluorescent tube bulbs (the fixture's diffuser).
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Witnessed light fixture properly secured in laz.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2020 Resolved
Mount the size 6A-120 B:C portable fire extinguisher for the machinery space with an approved bracket.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed fire extinguisher properly mounted in mach space.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 January 2020 Resolved
Install guards for exposed rotating hazards on both generators.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed guards installed on both gen sets.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 November 2019 Resolved
Vessel undergoing dockside maintenance period where life saving, firefighting, main propulsion, electrical and vital systems were found not operational and undergoing maintenance. Make available for inspection all systems and equipment applicable and required prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 30 January 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019 Resolved
Crop and renew wasted bottom plate as marked in lazarette. Starting at aft bulkhead thru fwd bulkhead approximately 18" outboard either side of the keel in laz. Continuing forward into MSD space starting at the aft blkhd crop and renew bottom plate forward to first transverse frame and outboard from keel 3 frame spaces to port and 1 to starboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 22 May 2019
Resolution: Renewed wasted bottom plate as marked in lazarette.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 April 2019 Resolved
Repair cracked weld as marked in port quarter of laz transverse frame.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Repaired cracked weld as marked in port quarter of laz transverse frame.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 26 April 2019 Resolved
Crop and renew wasted metal as marked in MSD space in way of both the port and starboard outboard stern tubes where they penetrate the hull. Starting in the engine room coming thru the fwd bulkhead in aft 4 transverse frame bays on both P/S.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Renewed wasted metal as marked in MSD space in way of both the port and starboard outboard stern tubes.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019 Resolved
Crop and renew wasted metal in engine room as marked at aft bulkhead spanning approximately 1.5 frame bays at 18" by 18".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 22 May 2019
Resolution: Renewed wasted metal in engine room as marked at aft bulkhead spanning approximately 1.5 frame bays at 18" by 18".
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019 Resolved
In the pump room starting approximately 4" aft of the forward bulkhead crop and renew wasted metal as marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 22 May 2019
Resolution: Renewed wasted metal as marked.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019 Resolved
In pump room make clad weld repairs to the 3 pitts indicated forward of the bilge suction manifold and 1 pitt located below what appears to be a previous battery box storage foundation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Witnessed sat clad welds.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 April 2019 Resolved
In Bunk room re-weld cracked frame, 4th frame forward of the aft bulkhead port of keel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Winessed renewed section of frame.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 April 2019 Resolved
In the forward void repair cracked welds on overhead bracket starboard side as marked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 22 May 2019
Resolution: Witnessed weld repairs as marked.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019 Resolved
In fore-peak make clad repair starboard side as marked underneath hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Witnessed sat clad repair.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 20 November 2018 Resolved
46 CFR 182.465(L)- Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Conditions found had security camera wires run through the damper exhaust area that whould have prevented the dampers from closing.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2018
Resolved 30 November 2018
Resolution: Wires were secured to a bulkhead away from the fire damper door allowing for free opening and closing of the fire dampers installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 20 November 2018 Resolved
46 CFR 161.010-2 -Floating electric water light shall meet requirements of ANSI/ UL 1196, where stated (1.4) the product must prevent electric shock or injury. 03 floating electric marker lights attached to the vessel's BAs were found not water tight due to casing hardware missing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 November 2018
Resolved 20 November 2018
Resolution: O/O had spares on hand and spliced the new floating electric marker lights to the BAs IAW 46 CFR 180.175(4).
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 November 2018 Resolved
46 CFR 185.700 - Operational Readiness - survival craft(s) must be in good working order and ready for immediate use. 01 BA on the vessel was found with about a 1x1 " tear in the polyurethane cover.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2018
Resolved 30 November 2018
Resolution: the tear in the BA was repaired using the manufacturer's product to effect such repairs to polyurathane BAs
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 November 2018 Resolved
46 CFR 184.710 - First aid kit found with contents missingand contents expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2018
Resolved 30 November 2018
Resolution: A new first aid kit was purchased and placed on the vessel. All contents were present and unexpired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2018 Resolved
46 CFR 182.530- (a) On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:...2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. Foundthe Engine room and forepeak high water alarms were inoperable; no visual or audible alarms for either space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2018
Resolved 30 November 2018
Resolution: High water alarm wiring for these spaces were checked and repaired. both space high water alarms operate IAW CFR with audio and visual
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
Vsl is broadcasting no IMO #, Vsl is broadcasting greater than expected vessel length, Vsl is broadcasting no static draft information and Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 27 June 2019
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Lifesaving › Lifefloat › Paddle
Issued 13 November 2017 Resolved
Provide 05 lifefloat paddles so that each lifefloat has 02 paddles. 46CFR180.175(d)
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 21 November 2017
Resolution: Provided
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 13 November 2017 Resolved
Repair/Replace fire detection panel in the bridge and prove operation to U.S.C.G. 46CFR181.400(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2017
Resolved 21 November 2017
Resolution: Provided
Engineering › Steering Gear System › Rudder
Issued 13 November 2017 Resolved
Repair/Replace nuts on port side steering platform and find permanent means to secure nuts to bolts. 46CFR176.814
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 21 November 2017
Resolution: Provided
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 November 2017 Resolved
Provide emergency escape light in forward passenger accommodation space. Prior to carrying overnight pax. 46CFR183.432(a)
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 21 November 2017
Resolution: Installed
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 November 2017 Resolved
Clean bilges in the engine room and properly dispose of oily debris. 46CFR176.830(b)
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 21 November 2017
Resolution: Removed
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 13 November 2017 Resolved
Provide instructions and labeling of fixed CO2 system. 46CFR485.612
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 21 November 2017
Resolution: Provided
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 November 2017 Resolved
Provide smoke detector in accommodation space (UL 217). Prior to carrying overnight pax. 46CFR181.450(a)
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 21 November 2017
Resolution: Installed
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 13 November 2017 Resolved
Replace port engine exhaust due to epoxy patch. 46CFR182.430(b)
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 21 November 2017
Resolution: Replaced
Operations/Management › Vessel Activity › Other
Issued 14 November 2016 Resolved
Credit drydock never completed. Vessel must complete credit drydock prior to any commercial operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2016
Resolved 22 February 2017
Resolution: MI attended vessel, cleared necessary requirements to credit Hull Exam.
Communications › Radio Communications › EPIRB
Issued 14 November 2016 Resolved
EPIRB registration expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement had been completed.
Communications › Radio Communications › EPIRB
Issued 14 November 2016 Resolved
EPIRB battery expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Lifesaving › Lifefloat › Retroreflective Material
Issued 14 November 2016 Resolved
Renew all retro tape on all lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2017
Resolution: Cleared [name withheld]
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 14 November 2016 Resolved
Starboard and Port FRP wet elbows water into the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 November 2016 Resolved
Starboard exhaust piping is leaking water. Vessel modified existing exhaust from dry into wet.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Construction/Loadline › Hull › Transverse Frame
Issued 14 November 2016 Resolved
Frame and stiffeners aft of port generator are cracked. Old repairs have failed. Grind and reweld all cracked areas.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 14 November 2016 Resolved
2015 MIS report missing.
Due 14 December 2016
Resolved 15 November 2016
Resolution: Received MIS report.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 June 2016 Resolved
Make temp repair to both MDE exhaust piping, and make avail for inspection w/vessel in the water.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: Temp repair had been made prior to MI attending vessel and permanent repairs were being carried out.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 June 2016 Resolved
Make permanent repairs to MDE exhaust piping. Crop/renew piping.
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Engineering › Fuel Oil Service System › Suction Strainer
Issued 7 June 2016 Resolved
Repair/renew wasted weld on port MDE Strainer.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: witnessed repair
Construction/Loadline › Hull › Weld
Issued 7 June 2016 Resolved
Repair cracked weld on fwd entrance way (stbd side).
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: Witnessed repair
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 June 2016 Resolved
Remove or repair outlet on stbd side of pilot house.
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Lifesaving › Lifefloat › Serviceable
Issued 7 June 2016 Resolved
Perform maintenance on all life floats. Clean
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Construction/Loadline › Hull › Weld
Issued 7 June 2016 Resolved
Clad weld plate port side just fwd of rudder post.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: This requirement had been completed at last dry docking. Found no need for "cladding" anything...
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 7 June 2016 Resolved
Replace both MDE spool/flanges with approved material and make available for inspection in the water. Prior to Credit Dry Dock
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 7 June 2016 Resolved
Replace both outboard MDE spool/flanges with approve material.
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 June 2016 Resolved
Replace hose portside on board MDE muffler. Prior to credit dry dock.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Construction/Loadline › Hull › Transverse Frame
Issued 27 May 2016 Resolved
Drill stop crack in #3 and #4 transverse frame just below the chine in compartment #3. Gouge out weld and reweld. Make avaialble for inspection PTCHE
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Engineering › Bilge Water Management System › Valve
Issued 27 May 2016 Resolved
Repair or replace bilge suction valve in collison compartment.
Due 30 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed. Reach rod was reconnected and a satisfactory test was completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 23 May 2016 Resolved
Remove metal exhaust section ends for inspection on #2 and #3 MDE wet exhaust. All the piping ends shows signes of wasteage (leaking water & sealent added to ends of hoses) PTCHE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed. New piping was being installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 23 May 2016 Resolved
#2 MDE sea suction valve shows signes of wastage. Remove sea vale and spool piece for inspection. PTCHE
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 1 February 2017
Resolution: Spool piece repaired.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 30 November 2015 Resolved
Fire detection system found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 14 December 2015
Resolution: New fire control panel changed out, reprogrammed, and functionally tested by Fortress Security Systems, INC.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 30 November 2015 Resolved
No valid certificate of documentation on board.
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 14 December 2015
Resolution: Vessel has been issued COD on 03DEC15 expiring on 31OCT16.
Lifesaving › Lifefloat › Paddle
Issued 30 November 2015 Resolved
12 paddles for life floats found unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2015
Resolved 14 December 2015
Resolution: Operator has replaced 12 wasted paddles with new ones.
Documentation › Certificates/Documents › FCC SSL
Issued 30 November 2015 Resolved
No FCC station license onboard.
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 14 December 2015
Resolution: Vessel provided with FCC station license issued on 12-02-2015.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 November 2010 Resolved
Service Fixed Fire fighting system.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Resolution: O/O provided a valid servicing report for system
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 30 November 2010 Resolved
Provide a valid FCC Safety certificate
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Resolution: O/O provided a valid FCC Radio safety cert
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 30 November 2010 Resolved
Provide a valid FCC radio station license
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Resolution: O/O provided a valid FCC station license for vessel
Engineering › Sea-water System (primary cooling) › Piping
Issued 17 December 2009 Resolved
Fabricate/replace PVC raw water to exhaust riser firrings on both center engines (with stainless).
Action required: 705 - Other - as specified
Due 17 January 2010
Resolved 22 January 2010
Construction/Loadline › Hull › Transverse Frame
Issued 13 April 2009 Resolved
Make proper repairs to the following areas in the forepeak: Cracked weld on stbd transverse frame, 3rd aft IWO chine; cracked weld on port transverse frame, 5th aft IWO chine and crack at bottom of stbd most vertical angle on aft bulkhead where conection to horizontal shelf.
Action required: 705 - Other - as specified
Due 17 April 2009
Resolved 17 April 2009
Resolution: Corrected
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 18 November 2008 Resolved
Provide servicing report to CG Marine Inspector for Fixed CO2 fire extinguishing system prior to 30 November 2008. If servicing report is not recieved by 30 November 2008, vessel will not be permitted to operate until completed.
Due 30 November 2008
Resolved 30 November 2008
Resolution: Servicing report for fixed CO2 fire extinguishing system was provided to Coast Guard detailing all tests that were performed.
Engineering › Fuel Oil Service System › Hose
Issued 25 October 2007 Resolved
Repair fuel oil leak on the Stbd. outboard propulsion engine fuel return hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2007
Engineering › Fuel Oil Service System › Piping
Issued 25 October 2007 Resolved
Repair fuel oil leak on the Stbd. inboard propulsiion engine supply pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 October 2007 Resolved
Service the fixed CO2 fire fighting system and fire detection system.
Due 1 December 2007
Resolved 30 November 2007
Resolution: CO2 fixed system and fire detection were serviced as required.
Construction/Loadline › Structures › Cofferdam
Issued 3 April 2007 Resolved
Make repairs to deck insert IWO STBD side MSD space. Insert had tack welding instead of a solid weld like the rest of the frame.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2007
Resolved 24 April 2007
Resolution: Insert was welded completely IWO STBD side MSD space.
Construction/Loadline › Structures › Deck Plating
Issued 3 April 2007 Resolved
Make repairs to two fractured frames IWO FWD peak. Found two welds that were cracked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2007
Resolved 24 April 2007
Resolution: Fractured frames were welded IWO FWD peak.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 23 October 2006 Resolved
Provide metallic pipe clamps on fuel return lines.
Condition: Improper/Lack of Maintenance
Due 27 November 2006
Resolved 1 November 2006
Resolution: Visited vsl and examined fuel pipe support installed for MDE''s.
Lifesaving › Buoyant Apparatus › Painter
Issued 23 October 2006 Resolved
Provide painter line for life float stowage to meet 46 CFR180.137.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 October 2006
Resolved 24 October 2006
Resolution: Rcv''d verbal notice that painters have been re-installed and inspector verified during visit on 1NOV.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 October 2006 Resolved
Post drug and alcohol policy and 800 hotline number
Due 27 November 2006
Resolved 1 November 2006
Resolution: Visited vsl and observed information posted.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 October 2006 Resolved
Display employee assistance program training material and provide training records req by 46 CFR 16.401
Due 27 November 2006
Resolved 1 November 2006
Resolution: Visited vsl and witnessed training information.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 23 October 2006 Resolved
Provide written procedures for alcohol testing for serious marine incidents to meet the 2 hr test requirements.
Due 24 October 2006
Resolved 25 October 2006
Resolution: Rcv''''d verbal from master that the alcohol test kits were on board and 11/1 inspector visited and cleared item.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 23 October 2006 Resolved
Provide deviation table for magnetic compass.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 15 May 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 October 2006 Resolved
Vessel is restricted to carrying 142 total persons until 10 additional USCG Type I lifejackets are provided with USCG approved lights for the vessel's Ocean's route.
Due 27 November 2006
Resolved 19 January 2007
Resolution: Visited vsl and observed additional lights provided for lifejackets.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 23 October 2006 Resolved
Replace starboard outboard main exhaust coupling clamp.
Due 27 November 2006
Resolved 1 November 2006
Resolution: Visited vsl and examined exhaust clamps renewed.
Construction/Loadline › Hull › Weld
Issued 23 October 2006 Resolved
Make repairs to holes in stbd deck rub rail IWO embarkation area by replacing boarding ramp pins by welding. Make temporary repairs prior to sailing.
Due 27 November 2006
Resolved 1 November 2006
Resolution: Rcv''d verbal notice that temporary repairs were made and inspector observed permanent welding of repairs on 1NOV.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 23 October 2006 Resolved
Make permanent repair to make bulkhead piping penetration starboard side fwd pumproom watertight. Make temporary repair prior to carrying passengers for hire.
Due 24 October 2006
Resolved 24 October 2006
Resolution: Rcv''d verbal notice of temporary repair prior to sailing and inspector witnessed permanent repair on 1NOV.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 23 October 2006 Resolved
Provide approved plans for bunk room and approval form mattresses.
Due 27 November 2006
Resolved 6 December 2006
Resolution: Plans submitted and under review.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 23 October 2006 Resolved
Prove firelite fire detection system and components required by 46 CFR 181.400 are CG approved and provide CG approved plans as listed on Fire and Safety plan notes as drawing C197-404 to be provided by vendor.
Action required: 705 - Other - as specified
Resolved 13 November 2017
Resolution: Discussed fire monitoring system w/ CID and determined to renwew current system w/ CG approved when system fails.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 23 October 2006 Resolved
No overnight passengers are permitted in the below deck Bunk Room (as listed on vessel plans) until CG approved plans and approval letter from the cognizant OCMI have been received meeting 46 CFR 177.800.
Action required: 705 - Other - as specified
Resolved 26 January 2007
Resolution: Rcv''d plans and OCMI/CID have accepted arrangements. Plan approval letter issued.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 23 October 2006 Resolved
Re-install metallic piing per CG approved plans at the port & stbd generator exhaust cooling pumps located at the stbd side of the pump room and remove all unauthorized non-metallic piping (PVC piping) in this vital system (generator exhaust cooling) as required by 46 CFR 182.700.
Due 27 November 2006
Resolved 19 January 2007
Resolution: Visited vessel and witnessed PVC piping replaced with galvanized piping.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 23 October 2006 Resolved
Make written request to cognizant OCMI for permission to carry overnight passengers. Request watchmen endorsement be added to vessel's COI per 46 CFR 185.410
Due 27 November 2006
Resolved 6 November 2006
Resolution: Rcv''d written request for addition of roving watchman to be added to the COI per 46 CFR 185.410.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 23 October 2006 Resolved
Provide CG approved plans for crew berthing located aft of the pilot house.
Due 27 November 2006
Resolved 6 November 2006
Resolution: Rcv''d plan submittal for crew berthing behind the pilothouse.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 25 May 2006 Resolved
Provide documented proof showing vessel is less than 100 gross tons.
Due 1 June 2006
Resolved 9 June 2006
Resolution: Per fax ltr fm O/O, ltr includes tonnage certificate and revised document with 92 GRT listed. Ltr scanned into documents for this activity.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 6 October 2004 Resolved
Prior to the carriage of passengers, provide a 40 amp overcurrent protector and associated wiring size for the fire pump as per MSC direction. Pump has a 24 amp system installed.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2005
Resolved 18 November 2005
Resolution: VERIFIED CHANGE IN PROTECTOR AND WIRE SIZE.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 6 October 2004 Resolved
Prior to the carriage of passengers, provide a 20 amp overcurrent protector and associated wiring size for the bilge pump as per MSC direction. Pump has a 15 amp system installed.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2005
Resolved 18 November 2005
Resolution: VERIFIED PROTECTOR CHANGE AND WIRE SIZE.
Engineering › Steering Gear System › Interlock
Issued 6 October 2004 Resolved
Provide a 200 - 250 amp over current protector for back-up steering pump, and make it a low-volt release switch as per MSC direction. Pump has to automatically come back on line when power is restored. As is, the pump has to manually restarted, plus the over current protection amps are to low as per MSC electrical plan reviewer.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2005
Resolved 18 November 2005
Resolution: VERIFIED SWITCH CHANGE OUT AND TESTED PUMP ON POWER FAILURE/START-UP, ALL SAT.
Engineering
Issued 9 November 1988 Resolved
MAKE FUEL COMPARTMENT & FRESH WATER COMPARTMENT GAS FREE. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Construction/Loadline
Issued 9 November 1988 Resolved
REPAIR FRACTURE IN STBD BERTHING AREA SHELL PLATE BY GRINDING OUT FRACTURE & WELDING.
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Construction/Loadline
Issued 9 November 1988 Resolved
REWELD FRACTURED BOTTOM FRAME IN ENGINE ROOM AFT PORT SIDE.
Condition: Unknown
Due 9 November 1988
Resolved 9 November 1988
Fire Fighting
Issued 29 April 1985 Resolved
PROVIDE A NEW FLAME SCREEN FOR THE FUEL OIL VENT.
Condition: Unknown
Due 29 April 1985
Resolved 29 April 1985
Navigation
Issued 29 April 1985 Resolved
INSTALL COTTER PINS ON THE BOLTS TO THE STEERING GEAR.
Condition: Unknown
Due 29 April 1985
Resolved 29 April 1985
Unknown
Issued 10 August 1983 Resolved
THE FOLLOWING DEFICIENCY IS FOR THE LINDA G., DN567912.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Unknown
Issued 10 August 1983 Resolved
LAG THE EXHAUST PIPING ON THE STARBOARD INBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 10 August 1983
Resolved 10 August 1983
Unknown
Issued 8 August 1983 Resolved
THE FOLLOWING DEFICIENCY IS FOR THE LINDA G, DN567912.
Condition: Unknown
Due 8 August 1983
Resolved 8 August 1983
Unknown
Issued 8 August 1983 Resolved
PRIOR TO DEPARTING PORT, MAKE PERMANENT REPAIRS TO THE ENGINE ROOM EQUIP- MENT DAMAGED IN THE FIRE AND DEMONSTRATE ITS SATISFACTORY OPERATION.
Condition: Unknown
Due 8 August 1983
Resolved 8 August 1983

Casualty record · 2

8 October 2001Routine · role: Involved in a Marine Casualty · activity 1626098
3 July 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3924255
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

WAVE DANCER (2001). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.