Records from 2001 to 2026. Most recent: inspection, 21 May 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 May 2025
Resolved
Replace/repair water light lines on L/F lights.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 22 May 2025
Resolution: Corrected prior to the end of the inspection
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 May 2025
Resolved
repair or replace 2 of the water lights for L/F's
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 22 May 2025
Resolution: Item corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 January 2025
Resolved
Remove excess electrical cord for prior bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 29 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 January 2025
Resolved
Remove the wasted bilge pipe suction coupling for further inspection in the tank void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 29 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 January 2025
Resolved
Remove the starboard inboard exhaust bellows for further inspection. (to be issued as deficiency following DD)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 January 2025
Resolved
Grind and reweld the marked welds on the rails and bulwarks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 29 April 2025
Resolution: Witnessed approx 12 locations. All SAT.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 January 2025
Resolved
Renew the door knob on the port emergency escape door on the 01 deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2025
Resolved 29 April 2025
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 January 2025
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. At fire inspection conducted on 30Jan25 time delay and audible siren in engine room failed to operate as designed. Vessel is authorized to make one time transit to home berth. Satisfactory operation of installed fire system to be witnessed by an attending Coast Guard Marine Inspector.
Action required: 15 - Rectify deficiencies by next port
Due 15 February 2025
Resolved 30 April 2025
Resolution: Witnessed. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 May 2024
Resolved
One of the vessels liferafts' waterlights was inop. restricted to daylight ops.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2024
Resolved 14 May 2024
Resolution: Battery replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 May 2024
Resolved
The fire pumps' gauge was inop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 14 May 2024
Resolution: Replaced gauge and tested. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2023
Resolved
An electric water heater is also acceptable if it is listed under UL174, UL1453 or other standard specified by the Commandant. On board Water heater is listed as UL 786H. Replace water heater with a compliant unit or provide evidence of historical acceptance by the Commandant.
Replaced. Proivded documentation that heater meets regulations prior to usage.
Action required: 705 - Other - as specified
Due 10 February 2023
Resolved 7 February 2023
Resolution: MI attended vessel and noted the installation of a satisfactory UL approved Hot water Heater
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2023
Resolved
When the exhaust cooling water system is separate from the engine cooling water system a suitable warning device, visible or audible must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system. Prior to departure from dry dock and repairs to the system, operationally test generator exhaust water cooling alarm to the satisfaction of an attending Marine Inspector.
Awaiting parts. Vessel authorized to make a one time transit to homeport in Montauk, NY. Vessel required to make continuous rounds of engine room during transit.
Action required: 705 - Other - as specified
Due 9 January 2023
Resolved 6 March 2023
Resolution: MI recieved video proof of satisfactory operation of alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2021
Resolved
Provide programed set points and parameters on the new engines...ie High jacket water temp alarm set points etc (and enabled safeties such as engine derate or shutdowns) to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2021
Resolved 25 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2021
Resolved
Conduct sea trials and testing of the new engines to the satisfaction of the attending USCG Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2021
Resolved 25 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2021
Resolved
Identified PFE;NFPA UL 40 B:C/ 4A for the passenger compartment with the gauge needle reading in the discharged zone. Company representative [name withheld] was able to provide a new and serviced PFE of the same rating.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 July 2021
Resolved
Identified PFE;NFPA UL 40 B:C/ 4A for the passenger compartment with the gauge needle reading in the discharged zone. Company representative [name withheld] was able to provide a new and serviced PFE of the same rating.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2021
Resolved
Identified dead end wiring for lighting on the PORT side by the pilot house cat walk. Issued requirement to remove of secure dead end wiring where risk of shock would exist if energized.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
Resolution: Dead end wiring removed and the port where the wiring came through was closed and secured using elec. cover
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2021
Resolved
Identified on the STBD side in the passenger cabin, at the forward entry way a plug hanging from wires where terminals were exposed posing risk of electrical shock.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
Resolution: Plug removed, Wires were capped off and a cover was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 July 2021
Resolved
Identified covers over all of the vessel's life floats provided IAW the COI. This cover would have either prevented or at a minimum hindered float free deployment. Issued requirement to remove covers to allow for float free deployment
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
Resolution: Covers were removed and life floats were set up in a float free condition when I departed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 July 2021
Resolved
EPIRB was kept in the vessel's pilot house and not set up for float free deployment. The vessel operator stated he kept the equipment there and in case of emergency he would take it. Additionally he stated stowed IAW regulations the EPIRB would blow off.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2021
Resolved 12 July 2021
Resolution: Installed the EPIRB in the case as required with the hydrostatic release and designed for float free operation.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 28 May 2021
Resolved
Remove temporary lighting above stbd mde.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2021
Resolved 28 May 2021
Resolution: Fixture was removed
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 May 2021
Resolved
Install capture device on steering hatch cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 28 May 2021
Resolution: Corrected on the spot
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2021
Resolved
Correctly label upperdeck capacity.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2021
Resolved 28 May 2021
Resolution: Corrected on the spot
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 May 2021
Resolved
An inspection for renewal of a COI is conducted to determine if the vessel is in satisfactory condition. COI is expired. Conduct renewal inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2021
Resolution: MI attended vessel and conducted a satisfacory COI
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 January 2020
Resolved
Repair or replace life floats on the 02 deck. Life floats grab lines and outer shells were identified as "dry rotted" due to excessive sun damage and exposure to the elements. The life floats in service dates was December 2004. Life Floats are not IAW Q specs 46 CFR 160.027-2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2020
Resolved 7 April 2020
Resolution: O/O replaced 07 life floats. 1 of the existing lifefloats remains servicable and 7 new were added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 January 2020
Resolved
6 adult life jackets were identified in unserviceable condition. All 06 were Kapok type I, where the closed cell was discovered compromised. Destroyed and removed the deficient PFDs. PFDs were carried in excess to regulation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 January 2020
Resolved 30 January 2020
Resolution: PFDs were carried in excess of regulation. PFDs were removed and destroyed.
//s// [name withheld], GS-12, USCG
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 30 January 2020
Resolved
Label paddles for the life floats with the vessel's name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed re-labeled paddles for life-floats.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 30 January 2020
Resolved
Identified EPIRB hydrostatic release expired in December 2018. Vessel representative stated he marked the install date on the hydro static release and thought he had 2 years after that date. This was a self marking system used on older hydrostatic releases. Vessel representative replaced the hydrostatic release on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 January 2020
Resolved 30 January 2020
Resolution: New hydro-static release purchased and installed.
//s// [name withheld], GS-12, USCG
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020
Resolved
Properly abandon or terminate all dead end wiring. 02 areas identified were where fishing lights have been removed and over the port generator in the machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 7 April 2020
Resolution: Properly abandoned or terminated all dead end wiring.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 30 January 2020
Resolved
Link the MMSI VHF-fm radio to a position source in accordance with 47 CFR 80.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Witnessed MMSI and position information installed on VHF radio.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020
Resolved
Non-conductive matting is required where switchboards are3 operated from. Place or install non conductive matting where the primary switchboard is operated from.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Witnessed newly installed electrical matting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020
Resolved
Secure power cables to the starboard VHF-fm radio using butt end type connectors. VHF-fm radio power wires were secured with screw type connectors.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed approved electrical connections installed in VHF wiring.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020
Resolved
All electrical outlets on weather decks must be watertight. Starboard side outlet is open and exposed to the elements.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed newly installed electrical outlet outside of wheelhouse.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020
Resolved
Re-wire public address speaker on the 2nd deck passenger area. Prove public address system can be operated from the primary operating station and heard in all areas of the vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Witnessed approved elecrtrical connections installed on PA speakers.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 January 2020
Resolved
Secure lighting fixture cover in the steering space where the cover is designed to protect the fluorescent tube bulbs (the fixture's diffuser).
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Witnessed light fixture properly secured in laz.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2020
Resolved
Mount the size 6A-120 B:C portable fire extinguisher for the machinery space with an approved bracket.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed fire extinguisher properly mounted in mach space.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 January 2020
Resolved
Install guards for exposed rotating hazards on both generators.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 11 February 2020
Resolution: Witnessed guards installed on both gen sets.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 November 2019
Resolved
Vessel undergoing dockside maintenance period where life saving, firefighting, main propulsion, electrical and vital systems were found not operational and undergoing maintenance. Make available for inspection all systems and equipment applicable and required prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 30 January 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019
Resolved
Crop and renew wasted bottom plate as marked in lazarette. Starting at aft bulkhead thru fwd bulkhead approximately 18" outboard either side of the keel in laz. Continuing forward into MSD space starting at the aft blkhd crop and renew bottom plate forward to first transverse frame and outboard from keel 3 frame spaces to port and 1 to starboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 22 May 2019
Resolution: Renewed wasted bottom plate as marked in lazarette.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 April 2019
Resolved
Repair cracked weld as marked in port quarter of laz transverse frame.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Repaired cracked weld as marked in port quarter of laz transverse frame.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 26 April 2019
Resolved
Crop and renew wasted metal as marked in MSD space in way of both the port and starboard outboard stern tubes where they penetrate the hull. Starting in the engine room coming thru the fwd bulkhead in aft 4 transverse frame bays on both P/S.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Renewed wasted metal as marked in MSD space in way of both the port and starboard outboard stern tubes.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019
Resolved
Crop and renew wasted metal in engine room as marked at aft bulkhead spanning approximately 1.5 frame bays at 18" by 18".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 22 May 2019
Resolution: Renewed wasted metal in engine room as marked at aft bulkhead spanning approximately 1.5 frame bays at 18" by 18".
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019
Resolved
In the pump room starting approximately 4" aft of the forward bulkhead crop and renew wasted metal as marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 22 May 2019
Resolution: Renewed wasted metal as marked.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019
Resolved
In pump room make clad weld repairs to the 3 pitts indicated forward of the bilge suction manifold and 1 pitt located below what appears to be a previous battery box storage foundation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Witnessed sat clad welds.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 April 2019
Resolved
In Bunk room re-weld cracked frame, 4th frame forward of the aft bulkhead port of keel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Winessed renewed section of frame.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 April 2019
Resolved
In the forward void repair cracked welds on overhead bracket starboard side as marked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 22 May 2019
Resolution: Witnessed weld repairs as marked.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 April 2019
Resolved
In fore-peak make clad repair starboard side as marked underneath hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2019
Resolved 23 May 2019
Resolution: Witnessed sat clad repair.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 20 November 2018
Resolved
46 CFR 182.465(L)- Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent.
Conditions found had security camera wires run through the damper exhaust area that whould have prevented the dampers from closing.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2018
Resolved 30 November 2018
Resolution: Wires were secured to a bulkhead away from the fire damper door allowing for free opening and closing of the fire dampers installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 20 November 2018
Resolved
46 CFR 161.010-2 -Floating electric water light shall meet requirements of ANSI/ UL 1196, where stated (1.4) the product must prevent electric shock or injury.
03 floating electric marker lights attached to the vessel's BAs were found not water tight due to casing hardware missing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 November 2018
Resolved 20 November 2018
Resolution: O/O had spares on hand and spliced the new floating electric marker lights to the BAs IAW 46 CFR 180.175(4).
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 November 2018
Resolved
46 CFR 185.700 - Operational Readiness - survival craft(s) must be in good working order and ready for immediate use.
01 BA on the vessel was found with about a 1x1 " tear in the polyurethane cover.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2018
Resolved 30 November 2018
Resolution: the tear in the BA was repaired using the manufacturer's product to effect such repairs to polyurathane BAs
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 November 2018
Resolved
46 CFR 184.710 - First aid kit found with contents missingand contents expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2018
Resolved 30 November 2018
Resolution: A new first aid kit was purchased and placed on the vessel. All contents were present and unexpired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2018
Resolved
46 CFR 182.530- (a) On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:...2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck.
Foundthe Engine room and forepeak high water alarms were inoperable; no visual or audible alarms for either space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2018
Resolved 30 November 2018
Resolution: High water alarm wiring for these spaces were checked and repaired. both space high water alarms operate IAW CFR with audio and visual
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018
Resolved
Vsl is broadcasting no IMO #, Vsl is broadcasting greater than expected vessel length, Vsl is broadcasting no static draft information and Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 27 June 2019
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Lifesaving › Lifefloat › Paddle
Issued 13 November 2017
Resolved
Provide 05 lifefloat paddles so that each lifefloat has 02 paddles. 46CFR180.175(d)
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 21 November 2017
Resolution: Provided
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 13 November 2017
Resolved
Repair/Replace fire detection panel in the bridge and prove operation to U.S.C.G. 46CFR181.400(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2017
Resolved 21 November 2017
Resolution: Provided
Engineering › Steering Gear System › Rudder
Issued 13 November 2017
Resolved
Repair/Replace nuts on port side steering platform and find permanent means to secure nuts to bolts. 46CFR176.814
Action required: 705 - Other - as specified
Due 16 November 2017
Resolved 21 November 2017
Resolution: Provided
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 November 2017
Resolved
Provide emergency escape light in forward passenger accommodation space. Prior to carrying overnight pax. 46CFR183.432(a)
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 21 November 2017
Resolution: Installed
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 November 2017
Resolved
Clean bilges in the engine room and properly dispose of oily debris. 46CFR176.830(b)
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 21 November 2017
Resolution: Removed
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 13 November 2017
Resolved
Provide instructions and labeling of fixed CO2 system. 46CFR485.612
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 21 November 2017
Resolution: Provided
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 November 2017
Resolved
Provide smoke detector in accommodation space (UL 217). Prior to carrying overnight pax. 46CFR181.450(a)
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 21 November 2017
Resolution: Installed
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 13 November 2017
Resolved
Replace port engine exhaust due to epoxy patch. 46CFR182.430(b)
Action required: 705 - Other - as specified
Due 27 November 2017
Resolved 21 November 2017
Resolution: Replaced
Operations/Management › Vessel Activity › Other
Issued 14 November 2016
Resolved
Credit drydock never completed. Vessel must complete credit drydock prior to any commercial operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2016
Resolved 22 February 2017
Resolution: MI attended vessel, cleared necessary requirements to credit Hull Exam.
Communications › Radio Communications › EPIRB
Issued 14 November 2016
Resolved
EPIRB registration expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement had been completed.
Communications › Radio Communications › EPIRB
Issued 14 November 2016
Resolved
EPIRB battery expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Lifesaving › Lifefloat › Retroreflective Material
Issued 14 November 2016
Resolved
Renew all retro tape on all lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2017
Resolution: Cleared [name withheld]
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 14 November 2016
Resolved
Starboard and Port FRP wet elbows water into the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 November 2016
Resolved
Starboard exhaust piping is leaking water. Vessel modified existing exhaust from dry into wet.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Construction/Loadline › Hull › Transverse Frame
Issued 14 November 2016
Resolved
Frame and stiffeners aft of port generator are cracked. Old repairs have failed. Grind and reweld all cracked areas.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 14 November 2016
Resolved
2015 MIS report missing.
Due 14 December 2016
Resolved 15 November 2016
Resolution: Received MIS report.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 June 2016
Resolved
Make temp repair to both MDE exhaust piping, and make avail for inspection w/vessel in the water.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: Temp repair had been made prior to MI attending vessel and permanent repairs were being carried out.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 June 2016
Resolved
Make permanent repairs to MDE exhaust piping. Crop/renew piping.
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Engineering › Fuel Oil Service System › Suction Strainer
Issued 7 June 2016
Resolved
Repair/renew wasted weld on port MDE Strainer.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: witnessed repair
Construction/Loadline › Hull › Weld
Issued 7 June 2016
Resolved
Repair cracked weld on fwd entrance way (stbd side).
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: Witnessed repair
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 June 2016
Resolved
Remove or repair outlet on stbd side of pilot house.
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Lifesaving › Lifefloat › Serviceable
Issued 7 June 2016
Resolved
Perform maintenance on all life floats. Clean
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Construction/Loadline › Hull › Weld
Issued 7 June 2016
Resolved
Clad weld plate port side just fwd of rudder post.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: This requirement had been completed at last dry docking. Found no need for "cladding" anything...
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 7 June 2016
Resolved
Replace both MDE spool/flanges with approved material and make available for inspection in the water. Prior to Credit Dry Dock
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 22 February 2017
Resolution: MI attended vessel and witnessed the correction of this requirement.
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 7 June 2016
Resolved
Replace both outboard MDE spool/flanges with approve material.
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 7 June 2016
Resolved
Replace hose portside on board MDE muffler. Prior to credit dry dock.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Construction/Loadline › Hull › Transverse Frame
Issued 27 May 2016
Resolved
Drill stop crack in #3 and #4 transverse frame just below the chine in compartment #3. Gouge out weld and reweld. Make avaialble for inspection PTCHE
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed.
Engineering › Bilge Water Management System › Valve
Issued 27 May 2016
Resolved
Repair or replace bilge suction valve in collison compartment.
Due 30 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed. Reach rod was reconnected and a satisfactory test was completed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 23 May 2016
Resolved
Remove metal exhaust section ends for inspection on #2 and #3 MDE wet exhaust. All the piping ends shows signes of wasteage (leaking water & sealent added to ends of hoses) PTCHE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 1 February 2017
Resolution: MI attended vessel and witnessed that the requirement was completed. New piping was being installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 23 May 2016
Resolved
#2 MDE sea suction valve shows signes of wastage. Remove sea vale and spool piece for inspection. PTCHE
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 1 February 2017
Resolution: Spool piece repaired.