MAURY USCG vessel records Sign in
← All vessels

ROTHORN

ROTHORN is a 1996 freight ship. The Coast Guard has recorded 72 inspections since 1998, most recently in August 2018, along with 34 deficiencies — 3 with no resolution recorded — and 20 operational controls.

Records from 1998 to 2018. Most recent: operational control imposed, 9 November 2018.

Built
1996
Last inspected
9 August 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9126986 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
484776
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-484776

Inspections, by type

…with no type recorded22
…past their stated due date1
Years with a record 13 calendar years (1998–2018)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12029 - Convention (Subpart B), Gross Ton
20443 - Displacement, Metric Ton
14663 - Dead Weight, Metric Ton
6171 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 72

9 August 2018 Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6505052
8 August 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6505005
7 August 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6504477
26 July 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6491008
25 July 2018 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6490677
7 May 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6408149
5 March 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6365783
23 February 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6360090
30 October 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6297611
19 October 2017 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6290696
2 August 2017 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6228256
21 July 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6214683
28 April 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6134374
13 April 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6123757
21 March 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6108764
13 February 2017 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6087196
20 January 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6073838
16 December 2016 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6058832
21 November 2016 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6045203
20 November 2016 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6044695
20 August 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5977917
26 July 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5953455
9 July 2016 PII Safety Exam · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5934708
27 January 2016 COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5804515
12 November 2015 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5761118
26 July 2011 PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4094584
12 May 2009 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3472316
15 April 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3184324
27 March 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3172409
22 February 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3153625
12 March 2007 MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2885624
2 February 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2866009
19 October 2006 Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2803367
7 August 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2739302
3 August 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2735401
6 June 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2672266
15 February 2006 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2585621
3 January 2006 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2559986
13 December 2005 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2551733
22 November 2005 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2539479
26 September 2005 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2501341
30 August 2005 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2481610
17 July 2005 Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · NPV Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2428485
14 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2427389
27 June 2005 MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · NPV Safety Exam · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2402171
5 June 2005 ISPS III Exam · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2379440
3 April 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2325994
30 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2323438
12 January 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2274274
28 September 2004 Random ISPS/MTSA/PSC
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2207655
4 July 2004 NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2120692
30 May 2004 Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2082466
28 May 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2081021
3 May 2004 Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2058137
27 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2053615
1 April 2004 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2035238
18 March 2004 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2026613
5 March 2004 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2018756
9 February 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2002847
5 February 2004 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2001238
12 January 2004 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1981677
28 December 2003 Type not recorded
No type recorded · USCGC CAMPBELL (WMEC 909) · Activity 1971998
28 July 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1859207
26 June 2003 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1827363
20 March 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1759936
16 March 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1757982
6 March 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1753608
27 February 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1750382
31 January 2003 Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1737467
30 January 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1737549
16 October 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 729417
14 October 1998 PII Safety Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 421540

Deficiency record · 34

03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 November 2018 No resolution recorded
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material and such covers shall be weathertight. Identified holes that were temporarily repaired in the following locations: three (03) holes, port side #2 fwd hold; one (01) hole stbd side, #1 aft hold; one (01) hole port side, #1 aft hold; one (01) hole stbd side, #2 aft hold; two (02) holes stbd side, #3 aft hold; one (01) hole fwd stbd side, #1 fwd hold. Require permanent repairs to be made.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 November 2018 No resolution recorded
All hatch covers shall be fitted with gaskets and clamping devices. Approximately 60% of all gasket material was missing from hatch covers. Temporary repairs were made. Require permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 November 2018 Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material and such covers shall be weathertight. Identified holes in the following locations: One (01) hole forward starboard side on #1 forward cargo hold. One (01) hole forward port side #2 cargo hold. ICLL 16.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2018
Resolution: Temporary repairs were made. Issued updated CG-5437B requiring permanent repairs prior to next US port after sailing foreign.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2018 Resolved
The machinery shall be installed to and protected as to reduce to a minimum any danger to persons on board. Indicator cock for cylinder #7 on main engine was leaking exhaust. 74 SOLAS (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2018
Resolution: Valve was replaced. DNV-GL verified repairs.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 5 September 2018 Resolved
1530- Radar- All ships of 300 gross tonnage and upwards shall be fitted with a 9GHz radar. The vessel's 9 GHz radar is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2018
Resolution: Vessel provided technical report attesting to proper repairs of X-band radar.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 9 August 2018 Resolved
Objective evidence discovered during an expanded ISM exam revealed the following non-confformities. These discrepancies, included with the other material deficiencies, are evidence the ship/company is not implementing the requirements of the ISM Code through the approved SMS procedures. An external audit is recommended. - ISM Code 1.3 The safety management system should include procedures ensuring non-conformities, accidents and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. The SMS states the Master is responsible for reporting non-conformities to the Designated Person using Form-01.1. The crew could not produce evidence of non- conformity reports related to holes in the hatch covers, missing hatch cover gaskets, or excessive oil leaks from the main diesel engine. - ISM Code 9.1 The company should ensure that any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken; and records of these activities are maintained. The SMS states the Designated Person shall ensure appropriate measures are initialized in response to reports. There is no evidence any corrective actions were taken as it relates to holes in the hatch covers, missing hatch cover gaskets, or excessive oil leaks from main engine. - ISM Code 10.2 30ac
Condition: Invalid
Action required: 30 - Ship detained
Due 9 September 2018
Resolved 12 November 2018
Resolution: Class conducted multiple ISM audits & issued temporary ISM-SMC valid until 25Dec2018.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 August 2018 Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material, and such covers shall be weathertight. Identified holes in the following locations: Two (02) holes, port side #2 FWD Hold; One (01) hole STBD side, #1 AFT Hold; One (01) hole PORT side, #1 AFT Hold; One (01) hole, STBD side, #2 AFT Hold; Two (02) holes, STBD side #3 AFT Hold. Additional holes likely present throughout hatch covers, in inaccessible locations. - ICLL 16.1 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 September 2018
Resolved 12 November 2018
Resolution: Temporary repairs completed. Issued updated FG-5437B requiring permanent repairs prior to next US port after sailing foreign.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 August 2018 Resolved
All hatch covers shall be fitted with gaskets and clamping devices. Approximately 60% of all gasket material was missing from hatch covers. Individual hatch covers are missing up to 80% of gasket material. - ICLL 16.1 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 September 2018
Resolved 12 November 2018
Resolution: Temporary repairs were made. Issued updated CG-5437B requiring permanent repairs prior to next US port after sailing foreign.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 August 2018 Resolved
Arrangements for the distribution and utilization of lube oil shall be such to ensure the safety of the ship and persons on board. Observed active leaks from main diesel engine block coating entire main diesel engine and pooling at base of engine block, coating deck plates and creating slipping and fire hazards. 74SOLAS(97) II-2/15.3 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 September 2018
Resolved 12 November 2018
Resolution: Verified adequate repairs were made and all oil was removed.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 9 August 2018 No resolution recorded
The master, owner, operator in charge of any vessel must remove fouling organisms from the vessels hull. Excessive algae growth identified on hull. 33CFR151.2050(f) 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 September 2018 — due date passed with no resolution recorded
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 February 2018 Resolved
0720- 79 SOLAS(97)II-2/20.1- On Board verification found 3 empty EEBD. Provide class report, purchase order receipts, and pictures of replacement EEBD's
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2018
Resolved 23 February 2018
Resolution: Class report, Purchase Receipts, and Photos submitted.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 23 February 2018 Resolved
0111- 79 SOLAS(14) 1/10(a)(v) - Last dry dock not recorded on Cargo Ship Safety Construction Certificate
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 February 2018
Resolved 5 March 2018
Resolution: Received new issue Safety Construction Certificate.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, High Pressure (fuel injection)
Issued 21 July 2017 Resolved
1410 - Where necessary, oil fuel and lubricating oil pipelines shall be screened or otherwise suitably protected to avoid as far as practicable oil spray or oil leakage on to hot surfaces or into machinery air takes. Multiple Double - jacket lines improperly installed on vicinity of number three and number four cylinders. 74 SOLAS (97cons.) II-2/15.5.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2017
Resolved 21 July 2017
Resolution: Repaired / Rectified: The jacket protection of high pressure fuel oil pipes were secured properly and found in order. Per DNV GL Surveyor ID No: G90839/ Job ID: 1025273
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 July 2017 Resolved
0570 - All electrical aparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Multiple lights on deck in cargo area adjacent to dangerous cargo, are broken, missing covers and have exposed wires. 74 SOLAS (04cons.) II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2017
Resolved 21 July 2017
Resolution: Repaired / Rectified: lights were verified for repair and normal operation as per DNV GL Surveyor ID No:G90839. Job ID: 1025273. See attestation from Class under documents for further detail.
Engineering › Fuel Oil Service System › Piping
Issued 21 July 2017 Resolved
1420 - In a ship in which oil fuel is used the arrangements for the storage distribution and utilization of the oil fuel shall be as to ensure the safety of the ship and persons on board. Multiple leaks found throughout machinery space. 74 SOLAS(97Cons.) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2017
Resolved 21 July 2017
Resolution: Repaired / Rectified: fuel oil high pressure pipes connections coming out of fuel pumps were retightened and the accumulated fuel /diesel oil in bay of high pressure pipe, located above crankcase door (port) of main engine was cleaned and found in order.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 21 July 2017 Resolved
1230 - Satisfactory means for safe passage shall be provided for the crew used in essential operation of the ship. Fractured handrail was found on the port side near bay seventeen. ICLL 66/88 annex I(reg.25.4)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 August 2017
Resolved 27 July 2017
Resolution: Damaged handrail was repaired and found in sound condition per DNV-GL Surveyor ID NO: G90839/Job ID: 1027293-1
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 20 January 2017 Resolved
Each marine sanitation device must be of such design to prevent toxic substances/gases from escaping to the interior of the vessel. Multiple holes (04) identified on the exterior of the MSD tank. Holes have been temporarily repaired with epoxy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2017
Resolved 13 February 2017
Resolution: Vessel sent class report attesting to the repair of the MSD.
Navigation › Piloting/Steering › Gyro Compass
Issued 20 November 2016 Resolved
All ships of 500 gross tonnage and upwards shall have a gyro-compass, or others to determine and display their heading by shipborne non-magnetic means. The vessel does not have an operable gyro-compass. Vessel has flag dispensation to make repairs no later than 19DEC16. To satisfaction of class and Coast Guard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 16 December 2016
Resolution: Vessel submitted Technician Report to verify that the GYRO COMPASS is functional.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 13 July 2016 Resolved
Fire fighting appliances shall be kept in good working order. Fireman's outfit was found in poor condition. 75% heat reflective material was missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2016
Resolved 13 July 2016
Resolution: New Fireman's outfit was delivered onboard.
Fire Fighting › Fire Main › Valves
Issued 13 July 2016 Resolved
Fire fighting appliances shall be kept in good working order. Forward fire main isolation valve on starboard side found with broken handle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 18 August 2016
Resolution: Recieved class attestation for the repair of the forward fire main isolation valve on the starboard side. See attached class report in documents.
Documentation › Logs/Records › Oil Record Book
Issued 13 July 2016 Resolved
Oil record book shall be completed on each occasion for machinery installed regarding collection of oil residues. Aux boiler sludge tank (2.07) has no records in oil record book since crew discontinued use. Tank was sounded and found empty. Tank is still listed on IOPP Form A.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 26 July 2016
Resolution: Recieved documentation that the vessel is conducting weekly soundings on the AUX boiler tank #2.07
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 July 2011 Resolved
Guard rail on port side midships is missing a one foot section of the center course. ISCC ChII Reg 25(4)
Action required: 705 - Other - as specified
Due 9 August 2011
Resolved 26 October 2011
Engineering › Steering Gear System › Hand Pump
Issued 26 July 2011 Resolved
Vessel has a broken pressure guarge on the steering gear. SOLAS 97 ChI Reg 11(b)
Action required: 705 - Other - as specified
Due 9 August 2011
Resolved 26 October 2011
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 26 July 2011 Resolved
Fire doors in sauna area and galley area have hooks screwed into them. SOLAS 97 ChII/2 Reg 47.2
Action required: 705 - Other - as specified
Due 9 August 2011
Resolved 26 October 2011
Fire Fighting › Structural - A Class Divisions › Special Category Spaces
Issued 26 July 2011 Resolved
Vessel installed sauna after class survey. SOLAS 97 ChI Reg II(b)
Action required: 705 - Other - as specified
Due 9 August 2011
Resolved 26 October 2011
Navigation › Piloting/Steering › Gyro Compass
Issued 15 April 2008 Resolved
Gyro Compass in-op.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2008
Resolution: Rec''d tech report attesting to repair & proper operation of gyro compass.
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 February 2007 Resolved
The vessel's secondary radar is inoperable.The vessel is required to have the radar repaired prior to departure and submitt the technicians report verifying the operation of the radar to the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2007
Resolution: received class report.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 19 October 2006 Resolved
The vessel has not prepared or submitted a Non-Tank Vessel Response Plan to the United States Coast Guard in accordance with the United States Federal Water Pollution Control Act as amended by Section 701 and the Coast Guard Maritime Transportation Act of 2004.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 24 November 2006
Resolution: NPFC e-VRP website shows that the vessel has submitted a Non-Tank Vessel Response Plan for review.
Personnel › Certificates/Documents/Licenses
Issued 31 January 2003 Resolved
Flag state to provide a correct issue date for chief mate's (Pablo M. Regaspi endorsement # 023911) stcw endorsement. Current stcw states item issued in 2005.
Due 1 March 2003
Resolved 20 March 2003
Resolution: Verified Chief Mate has had his Flag Endorsement corrected
Construction/Loadline › Markings
Issued 31 January 2003 Resolved
Vessel to paint loadline in color that contrast the hull. LEGACY COMPONENT DESC: Load Line Mark
Due 1 March 2003
Resolved 10 February 2003
Resolution: Vsl. painted loadline
Fire Fighting › Structural Fire Protection - General
Issued 31 January 2003 Resolved
Vessel to remove hold-back from fire screen door located in pool/sauna area.
Due 1 March 2003
Resolved 10 February 2003
Resolution: vsl. remove hold-back
Construction/Loadline › Hull
Issued 31 January 2003 Resolved
Class society to view and provide a class report on large indentation stbd side forward of loadline (frame 93-95)
Due 13 March 2003
Resolved 16 March 2003
Resolution: VSL PROVIDED CLASS REPORT DAMAGE TO BE DELT WITH AT NEXT DRY DOCK
Navigation
Issued 14 October 1998 Resolved
VESSEL ARRIVED IN PORT WITH GYRO INOPERATIVE. CAUSING ARPA TO ALSO BE _x001C_ INOPERATIVE.
Condition: Unknown
Due 16 October 1998
Resolved 16 October 1998
Navigation
Issued 14 October 1998 Resolved
VESSEL WAS MISSING 3 CHARTS FOR THE COPT AREA OF PUERTO RICO._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 1998
Resolved 15 October 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.