Records from 2016 to 2018. Most recent: operational control imposed, 9 November 2018.
Inspection history · 24
9 August 2018
Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6505052
8 August 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6505005
7 August 2018
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6504477
26 July 2018
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6491008
25 July 2018
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6490677
7 May 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6408149
5 March 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6365783
23 February 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6360090
30 October 2017
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6297611
19 October 2017
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6290696
2 August 2017
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6228256
21 July 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6214683
28 April 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6134374
13 April 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6123757
21 March 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6108764
13 February 2017
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6087196
20 January 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6073838
16 December 2016
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6058832
21 November 2016
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6045203
20 November 2016
In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6044695
20 August 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5977917
26 July 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5953455
9 July 2016
PII Safety Exam · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5934708
27 January 2016
COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5804515
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 November 2018
No resolution recorded
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material and such covers shall be weathertight. Identified holes that were temporarily repaired in the following locations: three (03) holes, port side #2 fwd hold; one (01) hole stbd side, #1 aft hold; one (01) hole port side, #1 aft hold; one (01) hole stbd side, #2 aft hold; two (02) holes stbd side, #3 aft hold; one (01) hole fwd stbd side, #1 fwd hold. Require permanent repairs to be made.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 November 2018
No resolution recorded
All hatch covers shall be fitted with gaskets and clamping devices. Approximately 60% of all gasket material was missing from hatch covers. Temporary repairs were made. Require permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 November 2018
Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material and such covers shall be weathertight. Identified holes in the following locations: One (01) hole forward starboard side on #1 forward cargo hold. One (01) hole forward port side #2 cargo hold. ICLL 16.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2018
Resolution: Temporary repairs were made. Issued updated CG-5437B requiring permanent repairs prior to next US port after sailing foreign.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2018
Resolved
The machinery shall be installed to and protected as to reduce to a minimum any danger to persons on board. Indicator cock for cylinder #7 on main engine was leaking exhaust. 74 SOLAS (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2018
Resolution: Valve was replaced. DNV-GL verified repairs.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 5 September 2018
Resolved
1530- Radar- All ships of 300 gross tonnage and upwards shall be fitted with a 9GHz radar. The vessel's 9 GHz radar is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2018
Resolution: Vessel provided technical report attesting to proper repairs of X-band radar.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 9 August 2018
Resolved
Objective evidence discovered during an expanded ISM exam revealed the following non-confformities. These discrepancies, included with the other material deficiencies, are evidence the ship/company is not implementing the requirements of the ISM Code through the approved SMS procedures. An external audit is recommended. - ISM Code 1.3
The safety management system should include procedures ensuring non-conformities, accidents and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. The SMS states the Master is responsible for reporting non-conformities to the Designated Person using Form-01.1. The crew could not produce evidence of non- conformity reports related to holes in the hatch covers, missing hatch cover gaskets, or excessive oil leaks from the main diesel engine. - ISM Code 9.1
The company should ensure that any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken; and records of these activities are maintained. The SMS states the Designated Person shall ensure appropriate measures are initialized in response to reports. There is no evidence any corrective actions were taken as it relates to holes in the hatch covers, missing hatch cover gaskets, or excessive oil leaks from main engine. - ISM Code 10.2
30ac
Condition: Invalid
Action required: 30 - Ship detained
Due 9 September 2018
Resolved 12 November 2018
Resolution: Class conducted multiple ISM audits & issued temporary ISM-SMC valid until 25Dec2018.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 August 2018
Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material, and such covers shall be weathertight. Identified holes in the following locations: Two (02) holes, port side #2 FWD Hold; One (01) hole STBD side, #1 AFT Hold; One (01) hole PORT side, #1 AFT Hold; One (01) hole, STBD side, #2 AFT Hold; Two (02) holes, STBD side #3 AFT Hold. Additional holes likely present throughout hatch covers, in inaccessible locations. - ICLL 16.1
30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 September 2018
Resolved 12 November 2018
Resolution: Temporary repairs completed. Issued updated FG-5437B requiring permanent repairs prior to next US port after sailing foreign.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 August 2018
Resolved
All hatch covers shall be fitted with gaskets and clamping devices. Approximately 60% of all gasket material was missing from hatch covers. Individual hatch covers are missing up to 80% of gasket material. - ICLL 16.1
30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 September 2018
Resolved 12 November 2018
Resolution: Temporary repairs were made. Issued updated CG-5437B requiring permanent repairs prior to next US port after sailing foreign.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 August 2018
Resolved
Arrangements for the distribution and utilization of lube oil shall be such to ensure the safety of the ship and persons on board. Observed active leaks from main diesel engine block coating entire main diesel engine and pooling at base of engine block, coating deck plates and creating slipping and fire hazards. 74SOLAS(97) II-2/15.3
30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 9 September 2018
Resolved 12 November 2018
Resolution: Verified adequate repairs were made and all oil was removed.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 9 August 2018
No resolution recorded
The master, owner, operator in charge of any vessel must remove fouling organisms from the vessels hull. Excessive algae growth identified on hull. 33CFR151.2050(f)
40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 September 2018 — due date passed with no resolution recorded
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 February 2018
Resolved
0720- 79 SOLAS(97)II-2/20.1- On Board verification found 3 empty EEBD. Provide class report, purchase order receipts, and pictures of replacement EEBD's
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2018
Resolved 23 February 2018
Resolution: Class report, Purchase Receipts, and Photos submitted.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 23 February 2018
Resolved
0111- 79 SOLAS(14) 1/10(a)(v) - Last dry dock not recorded on Cargo Ship Safety Construction Certificate
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 February 2018
Resolved 5 March 2018
Resolution: Received new issue Safety Construction Certificate.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, High Pressure (fuel injection)
Issued 21 July 2017
Resolved
1410 - Where necessary, oil fuel and lubricating oil pipelines shall be screened or otherwise suitably protected to avoid as far as practicable oil spray or oil leakage on to hot surfaces or into machinery air takes. Multiple Double - jacket lines improperly installed on vicinity of number three and number four cylinders. 74 SOLAS (97cons.) II-2/15.5.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2017
Resolved 21 July 2017
Resolution: Repaired / Rectified: The jacket protection of high pressure fuel oil pipes were secured properly and found in order. Per DNV GL Surveyor ID No: G90839/ Job ID: 1025273
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 July 2017
Resolved
0570 - All electrical aparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Multiple lights on deck in cargo area adjacent to dangerous cargo, are broken, missing covers and have exposed wires. 74 SOLAS (04cons.) II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2017
Resolved 21 July 2017
Resolution: Repaired / Rectified: lights were verified for repair and normal operation as per DNV GL Surveyor ID No:G90839. Job ID: 1025273. See attestation from Class under documents for further detail.
Engineering › Fuel Oil Service System › Piping
Issued 21 July 2017
Resolved
1420 - In a ship in which oil fuel is used the arrangements for the storage distribution and utilization of the oil fuel shall be as to ensure the safety of the ship and persons on board. Multiple leaks found throughout machinery space. 74 SOLAS(97Cons.) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2017
Resolved 21 July 2017
Resolution: Repaired / Rectified: fuel oil high pressure pipes connections coming out of fuel pumps were
retightened and the accumulated fuel /diesel oil in bay of high pressure pipe, located above crankcase door (port) of main engine was cleaned and found in order.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 21 July 2017
Resolved
1230 - Satisfactory means for safe passage shall be provided for the crew used in essential operation of the ship. Fractured handrail was found on the port side near bay seventeen. ICLL 66/88 annex I(reg.25.4)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 August 2017
Resolved 27 July 2017
Resolution: Damaged handrail was repaired and found in sound condition per DNV-GL Surveyor ID NO: G90839/Job ID: 1027293-1
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 20 January 2017
Resolved
Each marine sanitation device must be of such design to prevent toxic substances/gases from escaping to the interior of the vessel. Multiple holes (04) identified on the exterior of the MSD tank. Holes have been temporarily repaired with epoxy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2017
Resolved 13 February 2017
Resolution: Vessel sent class report attesting to the repair of the MSD.
Navigation › Piloting/Steering › Gyro Compass
Issued 20 November 2016
Resolved
All ships of 500 gross tonnage and upwards shall have a gyro-compass, or others to determine and display their heading by shipborne non-magnetic means. The vessel does not have an operable gyro-compass. Vessel has flag dispensation to make repairs no later than 19DEC16. To satisfaction of class and Coast Guard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 16 December 2016
Resolution: Vessel submitted Technician Report to verify that the GYRO COMPASS is functional.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 13 July 2016
Resolved
Fire fighting appliances shall be kept in good working order. Fireman's outfit was found in poor condition. 75% heat reflective material was missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2016
Resolved 13 July 2016
Resolution: New Fireman's outfit was delivered onboard.
Fire Fighting › Fire Main › Valves
Issued 13 July 2016
Resolved
Fire fighting appliances shall be kept in good working order. Forward fire main isolation valve on starboard side found with broken handle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 18 August 2016
Resolution: Recieved class attestation for the repair of the forward fire main isolation valve on the starboard side. See attached class report in documents.
Documentation › Logs/Records › Oil Record Book
Issued 13 July 2016
Resolved
Oil record book shall be completed on each occasion for machinery installed regarding collection of oil residues. Aux boiler sludge tank (2.07) has no records in oil record book since crew discontinued use. Tank was sounded and found empty. Tank is still listed on IOPP Form A.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 26 July 2016
Resolution: Recieved documentation that the vessel is conducting weekly soundings on the AUX boiler tank #2.07