LCPL ROY M WHEAT
Freight Ship · Ro-Ro Cargo Ship class · Built 1980s · USCG East District (CGD-E) · Other hulls named LCPL ROY M WHEAT
LCPL ROY M WHEAT is a 1987 freight ship. The Coast Guard has recorded 86 inspections since 1999, most recently in February 2025, along with 129 deficiencies, 10 operational controls and 6 casualty investigations between 2003 and 2018.
Records from 1999 to 2025. Most recent: inspection, 25 February 2025.
- Built
- 1987
- Last inspected
- 25 February 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 129 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 6 investigations · 2003–2018
Identity
1073560
8523137 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
NROY
484785
Flag
UNITED STATES
—
Maury page id
psix-484785
Inspections, by type
…with no type recorded14
Years with a record
22 calendar years (1999–2025)
The 86 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it44301 - Convention (Subpart B), Gross Ton
30366 - Dead Weight, Gross Ton
50277 - Displacement, Gross Ton
30748 - Regulatory (Subpart C or D), Gross Ton
15804 - Convention (Subpart B), Net Ton
27544 - Regulatory (Subpart C or D), Net Ton
30366 - Dead Weight, Gross Ton
50277 - Displacement, Gross Ton
30748 - Regulatory (Subpart C or D), Gross Ton
15804 - Convention (Subpart B), Net Ton
27544 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 86
25 February 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8084607
26 August 2022
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7540989
18 February 2020
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6915186
1 October 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6825713
25 September 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6825896
11 April 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6660702
1 April 2019
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6653926
28 February 2019
Deficiency Check · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6634031
31 January 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6618072
24 January 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6615204
16 November 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6582098
28 September 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6552238
25 September 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6548705
20 September 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6545132
12 September 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6538734
11 September 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6537924
11 September 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6537926
9 September 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6536132
6 September 2018
In-Service Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6534329
29 August 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6526765
28 August 2018
In-Service Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6526198
20 June 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6450238
18 June 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6449539
1 June 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6429440
21 May 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6420815
18 May 2018
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6417859
14 May 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6414680
2 May 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6404169
1 May 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6403100
12 April 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6405573
16 March 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6374466
22 February 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6359798
8 December 2017
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6326466
21 September 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6275230
11 September 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6262655
7 September 2017
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6262076
19 July 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6221633
6 July 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6212724
5 May 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6142798
2 November 2016
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6033838
1 November 2016
Annual Inspection · Administrative Inspection
Physical examination · Activities Europe · Activity 6029041
4 October 2016
Examination of Repairs · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6016329
3 October 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6014944
30 September 2016
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6013502
5 July 2016
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5929915
1 March 2016
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5829915
4 October 2015
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5773942
21 September 2015
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5724662
27 March 2014
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4824136
10 August 2011
Annual Inspection
Physical examination · Activities Europe · Activity 4111665
25 January 2011
Deficiency Check
Physical examination · Activities Europe · Activity 3928782
13 December 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3909609
10 December 2010
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4239793
15 November 2010
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3891822
26 October 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3877744
17 December 2009
Annual Inspection
Physical examination · Activities Europe · Activity 3654381
11 December 2008
Annual Inspection · In-Service Inspection
Physical examination · Activities Europe · Activity 3411530
19 May 2008
In-Service Inspection
Physical examination · Activities Europe · Activity 3239366
17 March 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3165888
15 January 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3130877
19 November 2007
Administrative Inspection · Examination of Repairs · In-Service Inspection · Internal Structural Exam · COI Inspection · MTSA/ISPS Verification · Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3106364
29 October 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3089178
24 April 2007
Annual Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 2897521
11 May 2006
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2647605
15 March 2006
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2603138
8 May 2005
MTSA/ISPS Verification · Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 2367449
22 March 2005
Deficiency Check · Administrative Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2316445
10 December 2004
Deficiency Check · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2259673
1 November 2004
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2232193
14 September 2004
Type not recorded
No type recorded · Activities Europe · Activity 2260340
24 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2109154
27 February 2004
Plan Review (Other than "T")
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2014281
23 February 2004
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2011537
18 February 2004
In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2008590
20 January 2004
Deficiency Check · Administrative Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1988872
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976247
26 December 2003
Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1970951
5 October 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1921418
10 September 2003
Reflagging & Initial Certification
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1702228
10 March 2003
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1755173
26 February 2003
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1749785
7 February 2003
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1741236
28 October 2002
In-Service Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1697591
30 August 2001
Reflagging & Initial Certification
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1047600
12 February 2000
Construction Oversight · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1449359
14 May 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 803426
Deficiency record · 129
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 3 October 2018
Resolved
The documents and reports required for a safety management system must include the written documents and reports itemized in 46 CFR table 96.250 (j) "Vessel maintenance procedures." The vessel's current SMS in not sufficient to adequately maintain the vessel in a seaworhty condition. Since Sep 2017 the vessel has been issued over 80 CG-835 requirements, over 25 of which have been prior to departure, prior to movement, or prior to conducting cargo operation deficiencies. Conduct an ISM audit to include a thorough review of vessel maintenance records and history by a recognized organization to the satisfaction of the attending Marine Inspector
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 September 2018
Resolved
Show proper operation of mechanical steering in the No.3 Lifeboat to satisfaction of attending U.S.C.G Marine Inspector. Total person onboard limited to 75 P.O.B.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 August 2018
Resolved
During testing of Low Pressure CO2 system, the ventilation for the engine room did not shut down when the system was activated. Repair and prove proper operation of ventilation shut down for engine room to the satisfaction of the CGMI.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 28 August 2018
Resolved
During testing of the Low Pressure CO2 system the following spaces did not have an audible alarm during testing, (01) Zone 4, Hold 5. (02) Zone 5, Hold 4. (03) Hold 10. Make repairs and prove proper operation to the satisfaction of the CGMI.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 May 2018
Resolved
The emergency fire pump space forward bulkhead and bilge suction rose box are corroded and wasted. Gauge the affected areas and provide gauging report to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Steering Gear System › Pump
Issued 12 April 2018
Resolved
Steering gear port auxiliary hydraulic pump seal failed during op test. Repair the port auxiliary hydraulic pump with in kind parts and prove the proper operation of the vessel'ssteering gear to the satisfaction of the attending USCG Marine Inspector prior to the vessel's movement.
Construction/Loadline › Structures › Door
Issued 22 March 2018
Resolved
Sliding WTD #2 has had a hydraulic pump fail. Make repairs and demonstrate proper operation to attending CG Marine inspector prior to getting underway.
Engineering › Generator (propulsion-electric) › Bus
Issued 16 March 2018
Resolved
Emergency generator cannot take load due to failure of the bus tie breaker. Repair bus tie breaker to the satisfaction of class and the U.S. Coast Guard. 74 SOLAS II-1/26(a)(ii)
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 16 March 2018
Resolved
Anchor windlasses are non operational resulting in an inability to drop the vessel's anchors. Repair windlasses to the satisfaction of class and the U.S. Coast Guard. 74 Solas 14 I/11
Engineering › Compressed Air System (start air) › Compressor
Issued 13 February 2018
Resolved
The #1 high pressure air compressor is working at 40% capacity. Repair the #1 high pressure compressor so that it operates as designed to the satisfaction of the attending marine inspector prior to departure from Hampton Roads, VA. 46 CFR 62.35-35 and 46 CFR 91.45.
Stability › Watertight Integrity › General
Issued 13 February 2018
Resolved
The watertight door position indicator panel on the bridge is not displaying the correct position of multiple watertight doors. Repair the watertight door position indicator panel and prove its proper operation to the satisfaction of the attending marine inspector prior to departure from Hampton Roads, VA. 46 CFR 170.248
Construction/Loadline › Structures › Scuttle
Issued 13 February 2018
Resolved
The starboard quarter chock quick acting watertight scuttle located at the freeboard deck has substantial corrosion, the gasket is deteriorated, and the closing mechanism is not operational. Repair the quick acting watertight scuttle to the satisfaction of the attending marine inspector prior to departure from Hampton Roads, VA. 46 CFR 171.122.
Engineering › Compressed Air System (control) › Compressor
Issued 13 February 2018
Resolved
The #1 and #2 mp air compressors are not operational. Repair the #1 and #2 mp air compressors and prove their proper operation to the satisfaction of the attending mairne inspecotr. 46 CFR 91.45
Fire Fighting › Fire Main › Condition
Issued 8 February 2018
Resolved
A LEAK HAS BEEN DISCOVERED IN THE VESSELS FIREMAIN ON THE STARBOARD QUARTER EXTERIOR DECK. PROVIDE A REPAIR PROPOSAL, REPAIR THE FIREMAIN, AND CONDUCT HYDROSTATIC TESTING OF THE REPAIRED SECTION OF FIREMAIN TO 150 PSI TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO DEPARTURE FROM HAMPTON ROADS, VA. 46 CFR 95.10
Fire Fighting › Fire Pumps › Power Source
Issued 8 February 2018
Resolved
THE #1 FIREPUMP IS NOT OPERATIONAL. REPAIR THE #1 FIREPUMP AND CONDUCT OPERATIONAL TESTING OF THE #1 FIREPUMP TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46CFR 91.45
Fire Fighting › Fire Pumps › Power Source
Issued 8 February 2018
Resolved
THE EMERGENCY FIRE PUMP CANNOT BE STARTED FROM REMOTE STARTING LOCATIONS, BUT CAN BE STARTED LOCALY. REPAIR THE EMERGENCY FIRE PUMP REMOTE STARTING CAPABILITIES AND PROVE THEIR OPERATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 91.45
Stability › Watertight Integrity › General
Issued 8 February 2018
Resolved
BOTH MACHINERY SPACE CLASS 3 WTD'S ARE NOT ABLE TO BE CLOSED VIA REMOTE ELECTRICAL ACTUATION. REPAIR BOTH MACHINERY SPACE CLASS 3 WTD'S REMOTE ELECTRICAL ACTUATION FUNCTIONS AND PROVE THIER PROPER OPERATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 170.270.
Construction/Loadline › Structures › Superstructure
Issued 8 February 2018
Resolved
THE PORT AND STARBOARD MACHINERY SPACE EXHAUST FIDDLY SPACES WERE OBSERVED TO HAVE SUBSTANTIAL CORROSION. PROVIDE A 6 INCH GRID UT REPORT OF ALL AREAS WITH CORROSION AND PROVIDE A REPAIR PROPOSAL TO THE SATISFCATION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 92.07-10 AND 46 CFR 91.45
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 29 September 2017
Resolved
Replace cargo holds 4, 10, and 13 low pressure co2 victaulic couplings with approved materials and conduct post installation testing and system certification prior to carrying cargo in cargo holds 4, 10, and 13 to the satisfaction of the attending Coast Guard Marine Inspector.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 15 September 2017
Resolved
The number 3 lifeboat primary steering is inoperable. Repair primary steering prior to departure to the stisfaction of the CGMI.
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 15 September 2017
Resolved
All lifeboats were provided with unapproved drinking water. Replace all lifeboat water with emergency drinking water approved IAW 46 CFR 160.026 prior to departure to CGMI.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 15 September 2017
Resolved
The proper operation of all survival craft muster and embarkation station lighting was not proven to be operable. Prove proper operation of all survival craft muster and embarkation station lighting prior to departure to the satisfaction of CGMI.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 15 September 2017
Resolved
Number 1 Fuel Oil transfer pump is inoperable. Demonstrate proper operation of the number 1 fuel oil transfer pump . Prior to departure to the satisfaction of CGMI.
Engineering › Bilge Water Management System › Pump
Issued 15 September 2017
Resolved
Bilge system was proven to be inoperable. Demonstrate proper operation of the bilge system using two independently power operated fixed pumps. Prior to departure to the satisfaction of CGMI.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 September 2017
Resolved
OWS is inoperable. Demonstrate proper operation of OWS, or offload all oily water and sludge tanks to a reception facility. prior to departure to the satisfaction of CGMI.
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 15 September 2017
Resolved
Htdraulic oil was discovered around the cargo deck number 1 and 2 hydraulic pumps. Clean the space, determine source of the leak and repair any leaks discovered. prior to departure to the satisfaction of CGMI
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 15 September 2017
Resolved
The cargo deck ventilation fans and fire dampeners were not proven to be fully operational on all decks (cargo) during the inspection. Prove proper operation of all ventilation fans and fire dampeners for cargo decks to the satisfaction of CGMI, prior to cargo operation.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 15 September 2017
Resolved
The 02 level cargo hold weathertight hatch was observed to be allowing excessive amounts of rain water to enter the cargo hold. Repair the cargo hold weathertight hatch so that it properly seals and is weathertight. To the satisfaction of the CGMI.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 September 2017
Resolved
The compass located at the main steering station on the bridge and the vessels gyrocompass have a 22 degree deviation. Correct the deviation and create a new deviation card, to the satisfaction of the CGMI.
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 15 September 2017
Resolved
VDR cables on the bridge are penetrating structural fire protection boundaries in the way of the bridge deck. Install a USCG approved cable penetration seal IAW manufactures installation instructions to the satisfaction of CGMI.
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 15 September 2017
Resolved
Aspirin and flashlight batteries in the rescue boat were found to be expired. Renew both with valid replacements to the satisfaction of the CGMI.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 15 September 2017
Resolved
The proper operation of the engine order telegraph and engine order telegraph alarms were unable to be verified. Prove proper operation of all engine order telegraphs and engine order telegraph alarms to the satisfaction of the CGMI.
Engineering › Bilge Water Management System › Valve
Issued 15 September 2017
Resolved
Dewatering remote operated valve number 72 is leaking hydraulic fluid excessivel. Valves 69 and 70 were not sealing correctly,(visible outside light was seen coming in from outside). Repair valves to the satisfaction of the CGMI.
Deck/Cargo › Holds/Tanks › Venitlation Fans
Issued 15 September 2017
Resolved
The proper operation of the cargo hold loss of ventilation alarm was unable to be verified. Prove the proper operation of the the cargo hold loss of ventilation alarm to the satisfaction of the CGMI.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 15 September 2017
Resolved
The shaft alley class 3 water tight door, indentified as water tight door #3, does not have an operational power operation hydraulic pump. Repair or replace in kind the shaft alley class 3 water tight door power operated hydraulic pump to the satisfaction of the CGMI.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 15 September 2017
Resolved
The vessels hospital toilet is not functional. Repair the hospital toilet to the satisfaction of the CGMI.
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 15 September 2017
Resolved
Cargo deck hydraulically operated WTD UKE-3 did not have an audible signal while the door was in motion and the visual signal was found to be activated before, during and after operation. WTD UKE-7 was observed to have a substantial hydraulic leak from a pressure gauge when pump is in operation. Repair and demonstrate proper operation of both doors to the satisfaction of the CGMI.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 15 September 2017
Resolved
A required embarkation ladder arrangement is not installed near the forward most life raft launching station. Install a USCG approved embarkation ladder at the forward most life raft launching station to the satisfaction of the CGMI.
Engineering › Steering Gear System › Hydraulic Hose
Issued 15 September 2017
Resolved
#2 Steering gear cooling water piping was replaced with suitable hose as a temporary temp repair. Permanently repair piping as original or install SAE J1942 hose assembly 30 inches or less overall legnth to the satisfaction of CGMI.
Engineering › Steering Gear System › Piping
Issued 15 September 2017
Resolved
#1 Steering gear piping is leaking at the flange. Repair piping as original to the satisfaction of CGMI.
Fire Fighting › Fire Pumps › Power Source
Issued 15 September 2017
Resolved
#1 Fire pump heater is connected with wire nuts. Properly install heater using approved pressure type connectors to the satisfaction of CGMI.
Construction/Loadline › Structures › Deck Plating
Issued 15 September 2017
Resolved
Deck in emergency fire pump and MSD spaces are severely pitted, wasted, and rusting. Gauge affected areas and provide gauging reports to the satisfaction of CGMI.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 15 September 2017
Resolved
#2 Sliding WTD (pipe tunnel) indicator lights electrical contact device was sticking. Prove proper operation of the device to the satisfaction of CGMI.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 15 September 2017
Resolved
6. #2 and #4 Sliding WTD’s will not close using the remote manual closing device. Prove proper operation of the remote manual closing devices to the satisfaction of CGMI.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 15 September 2017
Resolved
Found EOS console port shaft RPM gauge and bridge starboard shaft RPM gauge both giving erroneous shaft speed readings. Prove proper operation of both gauges to the satisfaction of CGMI.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 15 September 2017
Resolved
Found numerous self closing sounding tubes in engineering spaces are either pinned or tied in the open position. Remove make shift devices to the satisfaction of the CGMI.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 15 September 2017
Resolved
Found numerous Black Water piping leaks throughout the engineering and MDS spaces. Renew piping as original to the satisfaction of the CGMI.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 15 September 2017
Resolved
Found bilge high level alarm portside forward inoperable. Prove proper operation to the satisfaction of CGMI.
Communications › Alarms/Indicators › General Alarm
Issued 15 September 2017
Resolved
Gneral Alarm was found to be inoperative during drills, repair to the satisfaction to CGMI prior to departure.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 15 September 2017
Resolved
Disposable refridgeration bottles are being stored on the vessel. Remove all disposable refridgeration bottles from the vessel to the satisfaction of the attending CGMI. 46 CFR 147.60
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 15 September 2017
Resolved
Hydrostatic Release Units on 02 life rafts were found to be installed incorrectly, the painter line was not connected to the weak link. Re-install the HRU properly as per manufactures instructions to the satisfaction og CGMI.
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 15 September 2017
Resolved
Found low lube oil pressure false summary alarm for the #4 SSDG on the EOS panel. Prove proper operation of summary alarms to the satisfaction of CGMI.
Engineering › Compressed Air System (start air) › Valve
Issued 15 September 2017
Resolved
Found major leak of the #2 SSDG start air valve. Repair and prove proper operation to the satisfaction of CGMI.
Engineering › Generator (propulsion/auxiliary-electric) › Junction Box
Issued 15 September 2017
Resolved
Found conduit piping for the #3 SSDG wiring and hoses not secured and causing chafing. Secure conduit to the satisfaction of CGMI.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 15 September 2017
Resolved
Found “C” clamp holding exhaust flange for the #3 SSDG together. Properly secure exhaust flange to the satisfaction of CGMI.
Stability › Watertight Integrity › General
Issued 15 September 2017
Resolved
Found rain water is getting into the engine room in various locations and directly onto installed equipment i.e. SSDG sets, GTE reduction gear casings, various motor controllers, various lighting fixtures, various machinery systems piping, GTE exhaust lagging, etc. Determine source of openings and repair to the satisfaction of CGMI.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 15 September 2017
Resolved
Found EOS GTE temperature display doesn’t correspond with the proper temperature sensor. Repair and prove proper operation to the satisfaction of CGMI.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 September 2017
Resolved
Found over half of the emergency lighting above the EDG switchboard is not operational. Repair and prove proper operation to the satisfaction of CGMI.
Electrical › Electric Generation Source (emergency) › Conductor
Issued 15 September 2017
Resolved
Found welding cables installed in the EDG starting circuit. Install approved marine cables to the satisfaction of CGMI.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 September 2017
Resolved
Found lighting improperly installed using flexible extension cords. Remove flexible extension cord and light, or properly mount light using approved marine cables to the satisfaction of CGMI.
Engineering › Bilge Water Management System › Pump
Issued 15 September 2017
Resolved
Found cargo hold bilge pump is missing machinery guard, leaking on electrical connections and relief valve piping has been capped off. Install machinery guard, and repair to original to the satisfaction of CGMI
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 15 September 2017
Resolved
Found compress gas bottles near fixed CO2 system for GT module and Welding/Machine shop past due for hydro test. Remove from vessel to the satisfaction of CGMI. 46CFR147.60
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 September 2017
Resolved
Found numerous slip, trip, and fall hazards including overall poor housekeeping in the Welding/Machine shop. Remove hazards and properly stow equipment to the satisfaction of CGMI.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 15 September 2017
Resolved
Found expired EEBD in the MARPOL fuel oil storage space. Remove from vessel, replace with new EEBD, to the satisfaction of CGMI.
Engineering › Compressed Air System (start air) › Piping
Issued 15 September 2017
Resolved
Found raw water from sanitary piping system being temporarily used as cooling water for high pressure air compressor cooling source via 15 feet of non metallic flexible hose. Permanently repair compressor cooling piping as original to the satisfaction of CGMI.
Engineering › Bilge Water Management System › Pump
Issued 15 September 2017
Resolved
Found #2 power operated fixed bilge pump OOC. Renew in kind or obtain CG Marine Safety Center approval if replacement is not in kind. To the satisfaction of CGMI.
Engineering › Compressed Air System (control) › Valve
Issued 15 September 2017
Resolved
Found relief valve for the #1 medium pressure air receiver relieved outside of its allowable 5% readjustment range and could not be adjusted. Renew and test relief valve to the satisfaction of CGMI.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 15 September 2017
Resolved
Found Machinery Space supply fire damper #95 badly deteriorated beyond repair. Renew louvers and test to the satisfaction of CGMI.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 6 September 2017
Resolved
REPLACE THE CARGO HOLD LOW PRESSURE CO2 VITAULIC COUPLINGS WITH APPROVED MATERIALS AND CONDUCT POST INSTALLATION TESTING AND SYSTEM CERTIFICATION PRIOR TO CARRYING CARGO TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 23 August 2017
Resolved
A soft patch is installed on the anchor wash down piping. Provide documentation attesting to the stuctural integrity of the pipe in question or repair the pipe to the satisfaction of the attending Marine Inspector. 46 CFR 91.45
Fire Fighting › Fire Main › Condition
Issued 1 August 2017
Resolved
THE FIREMAIN WAS REPORTED TO BE DAMAGED AND LEAKING IN CARGO HOLD #2, PORTSIDE, FRAME 185. REPAIR THE FIREMAIN TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO THE VESSEL GETING UNDERWAY. 46 CFR 95.05-5.
Fire Fighting › Fire Main › Condition
Issued 19 July 2017
Resolved
The fire main was observed to be ruptured in the vicinity of the vessels fwd upper deck. Repair the fire main to the satisfaction fo the attending Marine Inspector prior to the vessel gettign underway. 46 CFR 95.05-5
Fire Fighting › Fire Pumps › Gland Sealing
Issued 5 May 2017
Resolved
One of the vessel's primary fire pumps is out of service for shore-side maintenance. Upon re-installation of pump, demonstrate proper operation to an attending CG [name withheld]: 46 CFR Part 95.10-5. DUE DATE: 02 June 2017.
Electrical › Electric Generation Source (service) › Generator
Issued 5 May 2017
Resolved
Vessel's #2 diesel generator has been taken out of service for maintenance. Upon completion of maintenance, demonstrate proper operation to an attending CG [name withheld]: 46 CFR Part 111.12-5. DUE DATE: 02 June 2017.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 1 November 2016
Resolved
Crew initially unable to start rescue boat engine
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 October 2016
Resolved
Permanent repairs completed with the following items pending: Two “pin hole” leaks where the lower 3” line is welded to the main 10” line and the upper 10” flange leak. Vsl authorized to depart for storm avoidance and complete repairs upon return. Repairs must be to the satisfaction of the attending marine inspector.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 October 2016
Resolved
Multiple temporary repairs identified on the S/W cooling to port R/G 10" elbow piping. One of which was recently repaired the second is a epoxy patch which was painted over. Crop to good pipe and renew prior to sail.
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 October 2016
Resolved
Temp repair to S/W piping on aux S/W to red gear cooler approved. Make permanent repairs at next port IAW repair proposal. Visually monitor temp repair while u/w by making additional rounds.
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 September 2016
Resolved
Make permanent repairs to the following salt water piping to remove soft water patch repairs. 1-aux s/w to red gear cooler, 2-#1 ssdg inlet s/w line, 3- #1 aux cooler/ssdg space, 4- #2 aux cooler/ssdg space
Fire Fighting › Fire Pumps › Arrangement
Issued 30 September 2016
Resolved
Both fire pumps have been recently overhauled. Prove proper operation of both pumps
Engineering › Gas Turbine (propulsion-reduction gear) › Piping
Issued 30 September 2016
Resolved
The following unauthorized/temp repairs must be repaired. S/W leak via a soft patch on the s/w to reduction gear cooler. 2. Soft patch found on the water inlet to the # 1 SSDG. 3. Soft patch found on the #1 auxiliary cooler (SSDG flat).4. Soft patch found on the #2 auxiliary cooler (SSDG flat).
Fire Fighting › Fire Pumps › Pressure
Issued 5 July 2016
Resolved
Both fire pumps in engine room have been overhauled without USCG or ABS knowledge. Prove proper operation of both pumps.
Engineering › Gas Turbine (propulsion-reduction gear) › Piping
Issued 5 July 2016
Resolved
Temporary repairs have been made to the stbd (10 inch) s/w line to the reduction gear as authorized by the OCMI in Jacksonville, FL. permanent repair shall be corrected before the vessel sails from the next loading port.
Lifesaving › Lifeboat › Propulsion Engine
Issued 1 March 2016
Resolved
The vessel’s #4 life boat engine is in operative and being repaired. Submit formal notice to [name withheld] requesting alternative compliance while vessel in OOC status.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 1 March 2016
Resolved
The fixed fire detection system alarm panel on bridge shows faults in Zone 3. Make repairs to restore fire panel as designed.
Construction/Loadline › Penetrations › Pipe Flange
Issued 1 March 2016
Resolved
There are several outside deck electrical kick pipe penetrations that are corroded and need maintenance, repair, or replacement.
Lifesaving › Lifebuoys › Serviceable
Issued 1 March 2016
Resolved
Life rings in various locations need new reflective tape.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 1 March 2016
Resolved
The steering gear room natural ventilation fire damper is broken (aft deck port side).
Deck/Cargo › Holds/Tanks › Hatch
Issued 1 March 2016
Resolved
The hatch gasket for hatch at 3-170-1 needs to replaced.
Construction/Loadline › Penetrations › Valve Flange
Issued 1 March 2016
Resolved
There are various weather/main deck fittings that have severely corroded flanges and/or fasteners. Make repairs to remove corroded components of all deck fittings.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 1 March 2016
Resolved
There are some deck lights with broken protective fittings and water inside glass cover. Make repairs to all deck lights in this condition.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 1 March 2016
Resolved
There are number of hydraulic leaks on cargo door and equipment. Make repairs to eliminate leaks/hazards
Lifesaving › Hand Flares › Storage
Issued 1 March 2016
Resolved
The distress signals/line throwing (pyro) lockers on the flying deck are wasted and markings are unreadable.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 1 March 2016
Resolved
There are fuel oil containment drains that have wood plugs instead of mechanical plugs. Replace plugs as necessary to eliminate potential for pollution.
Engineering › Freshwater Generation System › Piping
Issued 1 March 2016
Resolved
A few soft patches were noticed on exterior shipboard piping (upper deck drainage). Make permanent repairs to piping to restore back to original.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 September 2011
Resolved
Replace expired batteries for lifeboat portable radios.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 September 2011
Resolved
Remove portable heat lamp from low pressure CO2 tank level sensor line.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 September 2011
Resolved
Update Periodic Safety Test Procedures for generator over-speed function test to align with actual practice.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 30 November 2010
Resolved
Alarm and Monitoring System could be demonstrated with the submitted PSTP. Once the PSTP is approved, Alarm and Monitoring System must be verified to the satisfaction of the attending marine inspector.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 30 November 2010
Resolved
Re-submitt PSTP to MSC, w/ the corrections, for approval. Numerous discrepancies were noted during in service exam.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 November 2010
Resolved
Prove proper operation of the Stbd bilge sensor in the engineroom prior to getting U/W
Lifesaving › Launching Appliances › Winch Brake
Issued 18 January 2010
Resolved
Service technician found rescue boat winch brake measurements out of parameters. Measured .4mm, minimum reading is 1mm. Require replacement.
Lifesaving › Launching Appliances › Winch
Issued 18 January 2010
Resolved
Service technician found lifeboat davit winch brake readings nearing lower tolerances of 1mm. Readings were 1.7, 1.2, 0.9, and 1.5. Require replacement at next drydock scheduled for August 2010.
Fire Fighting › Fire Hoses › Condition
Issued 18 December 2009
Resolved
Complete pressure testing of remaining fire hoses to at least 100psi by 24 Dec 2009.
Lifesaving › Launching Appliances › Davit
Issued 18 December 2009
Resolved
Conduct annual servicing of lifeboats, launching appliances for both lifeboats and rescue boat, and on-load release gear by manufacturer or certified manufacturer's representative by 18Jan2010.
Lifesaving › Launching Appliances › Falls
Issued 18 December 2009
Resolved
Conduct 1.1 weight test of rescue boat wire rope by 18Jan2010. Provide test report, specifying test weight, to OCMI.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 18 December 2009
Resolved
Make pressure vessels avilable for internal inspection by 31AUG2010. If unable to inspect internally, conduct hydro inspection.
Electrical › Electric Generation Source (service) › Generator
Issued 19 November 2007
Resolved
#3 Diesel Generator damaged during rebuild of engine & power pack. Repair and test #3 Generator and #3 Switchboard iaw manufacture spec & CG approved automation test procedures.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 November 2007
Resolved
Dispose of and replace expired medicines located in ship's hospital space cabinets and refrigerator.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 15 March 2006
Resolved
Make repairs to the ground detector meters (440V, 120V and 120V emergency switchboard) to the satisfaction of the attending Marine Inspector. Extended df to allow time for design change and approved.
Construction/Loadline › Hull › Side Shell
Issued 1 February 2005
Resolved
Provide approval letter from the Marine Safety Center for the side door modification.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 February 2005
Resolved
Provide approval letter from the Marine Safety Center for the sliding watertight door modifications.
Engineering › Gas Turbine (propulsion-reduction gear) › Shaft
Issued 1 February 2005
Resolved
Provided for review and approval, corrected periodic safety test procedures to the [name withheld] as per 46 CFR Part 61.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 10 December 2004
Resolved
Prior to departing the Port of Mobile, prove operation of anchor and windlass.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 10 December 2004
Resolved
Install nozzles in way of hatch in Hold 2A to assure coverage of area intended.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 10 December 2004
Resolved
Properly pack wire penetrations in A class bulkheads in way of the galley, engine room, and anchor winch room.
Deck/Cargo › Mooring/Anchoring
Issued 20 January 2004
Resolved
Replace and prove proper operation of the port anchor and chain. LEGACY COMPONENT DESC: Anchor
Construction/Loadline › Hull
Issued 10 September 2003
Resolved
Conduct underwater hull survey in the presence of the USCG.
Construction/Loadline › Hull › Side Shell
Issued 10 September 2003
Resolved
Remove old loadline marks during next scheduled drydock availability. LEGACY COMPONENT DESC: Load Line Marks
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 September 2003
Resolved
Provide and post a USCG approved fire control plan.
Engineering
Issued 10 September 2003
Resolved
Provide and insert procedures for the "Periodic Testing" procedures for the following items: Gas Detection System; Fuel Oil Pressure to diesel generators; Fuel oil system & service tanks; and Vessels emergency communications. Item is to be cleared by MSO Hampton Roads Marine Inspector. LEGACY COMPONENT DESC: Automation Procedures
Engineering
Issued 10 September 2003
Resolved
Make all vital and non-vital alarms visually and audibly distinguishable throughout EOS and engine room. Item is to cleared by MSO Hampton Roads Marine Inspector. LEGACY COMPONENT DESC: Automation Alarms
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 10 September 2003
Resolved
Provide one (1) spare pre-programmed electronic control module for the emergency diesel generator and one (1) for the caterpillar ship's service generator. LEGACY COMPONENT DESC: Control Module
Engineering
Issued 10 September 2003
Resolved
Program all vital propulsion alarms to sound on the bridge and install a means for the operator to silence, but NOT acknowledge the alarms. Item is to be cleared by MSO Hampton Roads Marine Inspector. LEGACY COMPONENT DESC: Automation Alarms
Electrical › Electric Supply System (service)
Issued 10 September 2003
Resolved
Rewire or reduce stress being applied to the breakers inside the newly installed steering control boxes.
Fire Fighting › Structural - A Class Divisions
Issued 10 September 2003
Resolved
Properly seal penetration over door leading into the steering compartment. LEGACY COMPONENT DESC: Penetration
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 10 September 2003
Resolved
Replace all heat sensitive (copper) tubing leading through various fire stops in the following locations: Port Pipe Tunnel; Starboard Pipe Tunnel; and Steering Gear Room. Item is to be repaired during the next scheduled drydock availability.
Accommodation/Occupational Safety
Issued 10 September 2003
Resolved
Prove proper operation of the freon refrigeration detection system. LEGACY COMPONENT DESC: Freon Detection System
Accommodation/Occupational Safety
Issued 10 September 2003
Resolved
Make permanent repairs to the water leak and replace all ceiling smoke panels on the O3 level.
Casualty record · 6
26 February 2003Routine · role: Involved in a Marine Casualty · activity 1749785
24 October 2011Routine · role: Involved in a Marine Casualty · activity 4175381
1 September 2012Routine · role: Involved in a Marine Casualty · activity 4438250
12 April 2018Routine · role: Involved in a Marine Casualty · activity 6405573
20 June 2018Routine · role: Involved in a Marine Casualty · activity 6450238
12 September 2018Routine · role: Involved in a Marine Casualty · activity 6538734
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.