MAURY USCG vessel records Sign in
← All vessels

INTREPID

INTREPID is a 1975 mobile offshore drilling unit. The Coast Guard has recorded 40 inspections since 1982, most recently in December 1991, along with 83 deficiencies.

Records from 1982 to 1991. Most recent: inspection, 12 December 1991.

Built
1975
Last inspected
12 December 1991
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-48480

Inspections, by type

…with no type recorded16
Years with a record 10 calendar years (1982–1991)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 35 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it11511 - Regulatory (Subpart C or D), Gross Ton
9652 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 40

12 December 1991 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 947311
8 November 1991 Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 942234
6 February 1991 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1216518
1 February 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929743
22 January 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904674
23 November 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1217792
25 October 1990 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1218996
11 October 1990 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 903056
1 May 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927421
29 March 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237267
23 March 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216425
14 February 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236479
4 January 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238208
9 November 1989 Drydock Extension · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212107
22 August 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1198534
13 June 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1207249
28 April 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1195269
26 April 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035454
30 March 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205498
14 February 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1345085
7 December 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036730
7 October 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890549
18 July 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1339325
31 May 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 895885
18 May 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1351273
8 February 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1020874
11 November 1987 Hull Examination · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1330366
9 September 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311213
10 August 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017396
5 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004846
11 February 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309250
30 December 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295004
12 August 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990721
31 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295773
8 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977049
10 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975131
20 January 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281004
9 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279283
4 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272478
24 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276609

Deficiency record · 83

Unknown
Issued 11 October 1990 Resolved
REMOVE ACCUMULATED OIL FROM BILGES OF PORT & STARBOARD PUMPROOMS & MAKE PUMPROOM BILGES & SEA SUCTION SPOOL PIECES AVAILABLE FOR COAST GUARD INSPECTION. TO BE COMPLETED PRIOR TO DEPARTING THE CAPTAIN OF THE PORT, PORT ARTHUR, TEXAS ZONE.
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Fire Fighting
Issued 9 November 1989 Resolved
REPAIR THE HELO FUEL AFFF SYSTEM. THE FULEING SYSTEM SHALL BE SECURED UNTILREPAIRS ARE COMPLETED AND NO FUELING SHALL BE CONDUCTED.
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Accommodation/Occupational Safety
Issued 9 November 1989 Resolved
REPAIR THE VENTALATION LOUVERS IN THE PASSAGEWAY OUTSIDE THE TOOL PUSHERS OFFICE SO THATIT WILL BE CLOSABLE FROM OUTSIDE THE A/C TANK.
Condition: Unknown
Due 9 November 1989
Resolved 9 November 1989
Electrical
Issued 7 December 1988 Resolved
PROVIDE PROPER VISUAL OPERATION OF MUD PIT TOTALIZER ON THE DRILL FLOOR. (PURGE SYSTEM).
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Electrical
Issued 7 December 1988 Resolved
ENSURE ALL EYS FITTINGS ARE PROPERLY INSTALLED AND POURED IN THE SHALE SHAKER ROOM.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Deck/Cargo
Issued 7 December 1988 Resolved
PROVIDE MATERIAL, CONSTRUCTION AND WELD DETAILS ALONG WITH CALCULATIONS PROVIDING 2X MADP WITH A 4X BURST PRESSURE OF THE FLUID SEPERATOR ABOVE THE P TANK AIR COMPRESSOR.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Electrical
Issued 7 December 1988 Resolved
PROVIDE INFORMATION PERTAINING TO THE PRODUCTION GAS WATER ANALIZER'S FITNESS FOR OPERATING IN A CLASS I DIV 2 AREA.
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Fire Fighting
Issued 31 May 1988 Resolved
REVISE THE FIREFIGHTING AND LIFESAVING PLANS TO ADDRESS THOSE COMMENTS MADEIN [name withheld] LETTER OF 13MAY88 AND RE-SUBMIT SAME FOR APPROVAL. (46 CFR 109.563)
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Electrical
Issued 31 May 1988 Resolved
MAKE ALL ELECTRICAL INSTALLATIONS IN THE CLASSIFIED HAZARDOUS AREAS ON THE PRODUCTION DECKS APPROPRIATE FOR THOSE HAZARDOUS AREAS AS REQUIRED BY 46 CFR 111.105 AND PRESENT SAME FOR EXAMINATION BY A USCG INSPECTOR PRIOR TO PLACING THE PRODUCTION EQUIPMENT INTO OPERATION.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Unknown
Issued 18 May 1988 Resolved
THE PRODUCTION SYSTEM GAS DETECTION SYSTEM MUST BE TESTED PRIOR TO THE PRODUCTION SYSTEM BEING PLACED INTO OPERATION & NLT 30MAY88
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Fire Fighting
Issued 11 November 1987 Resolved
PROVIDE PROPER BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS NLT 15DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Unknown
Issued 11 November 1987 Resolved
THE MSD MUST BE MADE TO COMPLY WITH THE APPROVED MANUFACTURER OPERATING MANUAL & DRAWINGS & OPERATIONALLY TEST NLT 15DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Electrical
Issued 11 November 1987 Resolved
EMERGENCY LIGHTING MUST BE PROVIDED FOR THE UPPER PRODUCTION DECK & FORWARDEMBARKATION LADDERS, PORT & STBD SIDES, NLT 15DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Unknown
Issued 11 November 1987 Resolved
THE POTABLE WATER SUPPLY LINE TO THE ROTARY COOLING BRAKE WATER TANK MUST BE PROVIDED WITH A 3" GAP IAW USCG MSC LETTER DTD 13JAN87 NLT 01FEB88.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Lifesaving
Issued 11 November 1987 Resolved
OPERATING INSTRUCTIONS FOR THE DAVIT LAUNCHED LIFERAFTS MUST BE CONSPICUOUSLY POSTED THROUGHOUT THE VESSEL IAW 46CFR108.655 NLT 15DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Unknown
Issued 11 November 1987 Resolved
THE PRODUCTION RISER SYSTEM AIR TUGGER FILTERS, IF INSTALLED, MUST BE ASME APPROVED IAW USCG MSC LETTER DTD 13JAN87 NLT 01FEB88.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Deck/Cargo
Issued 11 November 1987 Resolved
THE STARBOARD CRANE AUXILIARY LINE MUST BE PROPERLY WEIGHT LOAD TESTED PRIOR TO PLACING INTO OPERATION AND NLT 15DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Unknown
Issued 11 November 1987 Resolved
THE DIVER'S AIR SYSTEM MUST BE MADE AVAILABLE FOR INSPECTION NLT 01FEB88.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Unknown
Issued 11 November 1987 Resolved
THE PRODUCTION SYSTEM MUST BE MADE AVAILABLE FOR INSPECTION PRIOR TO PLACING INTO OPERATION & NLT 01FEB88.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Electrical
Issued 11 November 1987 Resolved
AN ADDITIONAL JP5 FUEL EMERGENCY SHUTDOWN SWITCH MUST BE PROVIDED FOR THE FORWARD HELO DECK ACCESS IAW 46CFR108.239(E) NLT 15DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Documentation
Issued 11 November 1987 Resolved
THE VESSEL'S TEMPORARY FIREFIGHTING & LIFESAVING PLANS MUST BE REPLACED WITH PERMANENT USCG APPROVED PLANS NLT 01JAN88.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Unknown
Issued 11 November 1987 Resolved
THE DRILLING SYSTEM MUST BE MADE AVAILABLE FOR INSPECTION PRIOR TO PLACING INTO OPERATION & NLT 01FEB88.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Construction/Loadline
Issued 11 November 1987 Resolved
THE MOORING SYSTEM MUST BE MADE AVAILABLE FOR OPERATIONAL INSPECTION NLT 15DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Unknown
Issued 11 November 1987 Resolved
THE PRODUCTION SYSTEM GAS DETECTION SYSTEM MUST BE TESTED PRIOR TO THE PRODUCTION SYSTEM BEING PLACED INTO OPERATION & NLT 01FEB88.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Unknown
Issued 11 November 1987 Resolved
GENERAL ALARM BELLS MUST BE INSTALLED AND TESTED FOR THE MESS ROOM, PASSAGEOUTSIDE SCR ROOM, & BALLAST CONTROL ROOM NLT 15DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Fire Fighting
Issued 11 November 1987 Resolved
REPAIR THE INOPERATIVE O2/EXPLOSIVE METER FOR FIREMAN'S OUTFIT (2 REQD.) NLT 01DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Construction/Loadline
Issued 11 November 1987 Resolved
THE THREE MUD PIT ROOM DOORS MUST BE MADE SELF CLOSING & GAS-TIGHT BY REPLACING GASKETS NLT 01FEB88.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Lifesaving
Issued 11 November 1987 Resolved
THE TEMPORARY BILGE PUMP IN #2, PORT LIFEBOAT MUST BE REPLACED WITH A USCG APPROVED TYPE NLT 15DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Unknown
Issued 11 November 1987 Resolved
PROVIDE NAMEPLATE FOR THE CLASS II AIR RECEIVER LOCATED BELOW THE DRILL FLOOR ADJACENT TO THE MOON POOL AREA NLT 01FEB88.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Unknown
Issued 11 November 1987 Resolved
THE PRODUCTION SYSTEM AIR COMPRESSOR DRIVE BELTS MUST BE REPLACED WITH STATIC FREE TYPE BELTS WHICH ARE APPROVED FOR HAZARDOUS LOCATIONS NLT 01FEB88.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Electrical
Issued 11 November 1987 Resolved
THE JUNCTION BOXES & CAMERA FOR THE PORT FORWARD MOORING SYSTEM MUST BE INSTALLED OUTSIDE THE HAZARDOUS LOCATION AROUND THE JP5 FUEL TANK NLT 15DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Construction/Loadline
Issued 11 November 1987 Resolved
THE PENETRATIONS IN THE SHALE SHAKER HOUSE OVERHEAD & AFT BULKHEAD MUST BE PROPERLY SEALED NLT 01FEB88.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Electrical
Issued 11 November 1987 Resolved
REMOTE FUEL SHUTDOWNS MUST BE PROVIDED AT THE PORT & STBD ELEVATOR STATIONS(STBD NEEDS MARKING ONLY ON CONTROLLER) FOR THE FUEL PUMPS AND FOR THE FUELOIL PURIFIER IAW 46CFR111.103-7&9, NLT 15DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Unknown
Issued 11 November 1987 Resolved
ALL REMOTE VENT SHUTDOWNS MUST BE MARKED IAW 46CFR 111.103-7 NLT 15DEC87.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Electrical
Issued 11 November 1987 Resolved
THE H.P. REFRIGATION DRYER CIRCUIT BREAKERS MUST BE REPLACED WITH 20 AMP SIZE IAW 46CFR111.70-1 AS REQD BY USCG MSC LETTER DTD 14OCT86, NLT01FEB88.
Condition: Unknown
Due 11 November 1987
Resolved 11 November 1987
Accommodation/Occupational Safety
Issued 12 August 1985 Resolved
DISCONNECT FIXED 125 PSI AIR SUPPLY PIPING FROM TWO EACH PORTABLE WATER TANKS (REF46CFR58.305(B).
Condition: Unknown
Due 12 August 1985
Resolved 12 August 1985
Electrical
Issued 12 August 1985 Resolved
MAKE OPERABLE THE AIR PURGE ALARM ON THE DRILLER'S CONSOLE 46CFR111.105
Condition: Unknown
Due 12 August 1985
Resolved 12 August 1985
Electrical
Issued 12 August 1985 Resolved
PROVIDE ELECTRICAL BLANKS OVER OPENINGS IN 480 V SWITCH PANAL IN GALLEY 46CFR111.30
Condition: Unknown
Due 12 August 1985
Resolved 12 August 1985
Electrical
Issued 12 August 1985 Resolved
MARK ALL UNMARKED MOTOR CONTROLLERS ON DRILL FLOOR 46CFR111.70
Condition: Unknown
Due 12 August 1985
Resolved 12 August 1985
Fire Fighting
Issued 12 August 1985 Resolved
REPLACE DAMAGED FIRE HOSE NOZZLE AT FIRE STATION #29 46CFR108.425.
Condition: Unknown
Due 12 August 1985
Resolved 12 August 1985
Electrical
Issued 12 August 1985 Resolved
REMOVE NON UL OR FM APPROVED SUB SEA SYSTEM VIDEO EQUIPMENT FROM CLASSIFIEDLOCATION ON DRILL FLOOR 46CFR111.105.
Condition: Unknown
Due 12 August 1985
Resolved 12 August 1985
Electrical
Issued 12 August 1985 Resolved
MAKE OPERABLE THE AIR PURGE ALARM ON THE HEET RITE RECORDER OR REMOVE SAME FROM DRILL FLOOR 46CFR111.105
Condition: Unknown
Due 12 August 1985
Resolved 12 August 1985
Lifesaving
Issued 12 August 1985 Resolved
REMOVE ALL OF LOT 101 DATED 9-83 DATREX EMERGENCY DRINKING WATER FROM THE PORT LIFEBOAT AND REPLACE WITH NEW WATER. USCG NVC 4-85 46CFR108.503
Condition: Unknown
Due 12 August 1985
Resolved 12 August 1985
Electrical
Issued 12 August 1985 Resolved
REMOVE NON UL OR FM APPROVED TELEPHONE SYSTEM FROM DOG HOUSE ON DRILL FLOOR46CFR111.105.
Condition: Unknown
Due 12 August 1985
Resolved 12 August 1985
Electrical
Issued 12 August 1985 Resolved
REPAIR TWO DAMAGED EYS FITTINGS AT ELECTRICAL FUNCTION BOXES STARBOARD SIDEOF DRILL FLOOR 46CFR111.105
Condition: Unknown
Due 12 August 1985
Resolved 12 August 1985
Construction/Loadline
Issued 31 January 1985 Resolved
RAPAIR THE DEMAGED AREA AT THE 70' LEVEL, STARBOARD CENTER COLUMN. 5 VERTICAL STIFFNERS ARE TRIPPED. REPAIRS ARE TO BE COMPLETED AT THE NEXT SCHEDULED DRYDOCKING.
Condition: Unknown
Due 31 January 1985
Resolved 31 January 1985
Unknown
Issued 10 August 1984 Resolved
PROVIDE PERSONNEL PROTECTION FROM MOVING DRUMS OF THE AIR OPERATED WENCHES 46CFR58.60.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984 Resolved
PROVIDE A BACKING ALARM AND FIRE EXTINGUISHER TO THE FORLIFT 46CFR 108.613.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984 Resolved
PROVIDE EVIDENCE THAT THE MARINE SANITATION DEVICE MEETS COAST GUARD APPRO-VAL 33CFR159. ALL REPAIRS ARE TO BE COMPLETED TO THE SATISFACTION OF THE OFFICER IN CHARGE NO LATER THAN 10SEPTEMBER, 1984.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN THE VESSEL PENROD 72 DN568024
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984 Resolved
PROVIDE ONBOARD AT LEAST ONE INTERNATIONAL SHORE CONNECTION, AS PER 46CFR 95.10-10(C.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984 Resolved
PROVIDE ALTERNATING YELLOW AND BLUE LIGHTS ON OUTSIDE PERIMETER OF HELICOP-TER DECK AS PER 46CFR 108.241(A)(2).
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984 Resolved
PROVIDE ONBOARD A RECORD OF FIRE FIGHTING EQUIPMENT INSPECTION, AS PER 46CFR 109.435.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984 Resolved
PROVIDE A PORTABLE CONTAINER OF FIVE GALLONS OR LESS THAT HAS A SELF CLOS- ING SPOUT, AS PER 46CFR(109.537(D).
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984 Resolved
PROVIDE ONBOARD A COAST GUARD APPROVED CONSTRUCTION PORTFOLIO, AS PER 46CFR107.305(HH)
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984 Resolved
PROVIDE A FUEL OIL DAY TANK SUCTION VALVE REMOTE CLOSURE THAT CAN BE USED IN ALL OPERATING CONDITIONS IN THE PIPE PACK AREA. 46CFR56.50.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION #5356 BULK CHEMICAL TANK 46CFR61.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984 Resolved
PROVIDE DOCUMENTATION OF OR CONDUCT OPERATIONAL TESTS OF THE HIGH PRESSURE TENSIDNER RELIEF VALVES 46CFR61.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984 Resolved
REPAIR THE INOPERATIVE BALLAST SUCTION VALVE #913 AS SOON AS POSSIBLE 46CFR107.231.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 4 August 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU PENROD 72, DN568024
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Navigation
Issued 4 August 1983 Resolved
REPAIR GENERAL ALARM BELLS OUT SIDE EMERGENCY GENERATOR ROOM AND INSIDE THESACK STORAGE ROOM.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Construction/Loadline
Issued 4 August 1983 Resolved
REPLACE BROKEN GLASS ON BNOTH MUD PIT DOORS.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Electrical
Issued 4 August 1983 Resolved
REMOVE ALL SILICONE FROM ALL EYS SEALS AND REPALCE WITH CHICO X.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Electrical
Issued 4 August 1983 Resolved
METAL STRAP ALL LOOSE CABLES THROUGHTOUT VESSEL AS NECESSARY.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Electrical
Issued 4 August 1983 Resolved
REPLACE SOUND POWERED PHONES IN BOTH ELEVATORS.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Lifesaving
Issued 4 August 1983 Resolved
RENEW EQUIPMENT MARKINGS AND INSTRUCTIONS AS PER 46 CFR SUBCHAPTER 6.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Accommodation/Occupational Safety
Issued 4 August 1983 Resolved
MAKE MARINE SANITATION DEVICE OPERABLE PRIOR TO ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Lifesaving
Issued 4 August 1983 Resolved
REPAIR BROKEN FLOODLIGHT AT CONTROL STATION FOR PORT LIFEBOAT.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Construction/Loadline
Issued 4 August 1983 Resolved
REPAIR QUICK-ACTING SCUTTLE OVERHEAD AT ELEVATOR LEVEL OF PORT PUMPROOM.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Lifesaving
Issued 4 August 1983 Resolved
REPLACE THE TWO (2) SMOKE SIGNALS FOR THE RING BOUYS.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Deck/Cargo
Issued 4 August 1983 Resolved
INSTALL ELEVATOR DOOR SWITCHES ON TOP DOORS OF BOTH ELEVATORS. (THE SAME ASON BOTTOM DOORS).
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Unknown
Issued 4 August 1983 Resolved
SUBMIT HAZARDOUS AREA AND FIRE CENTRAL PLANS FOR USCG APPROVAL.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Construction/Loadline
Issued 4 August 1983 Resolved
REARRANGE BUNKS IN ROOMS ON PORT SIDE TO COMPLY WITH ORIGINAL ACCOMMODA- TIONS/FIRE CONTROL PLAN.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Fire Fighting
Issued 4 August 1983 Resolved
REPAIR CLASS "C" CEILING IN ROOM NO. 1.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Deck/Cargo
Issued 4 August 1983 Resolved
PROVIDE OPERABLE ASME RELIEF VALVES WITH HAND RELIEVING GEAR ON THE SALT WATER PRESSURE TANKS, ON THE BULK TANKS AND ON THE MOTION COMPENSATION
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Deck/Cargo
Issued 4 August 1983 Resolved
(REQUIREMENT 5 CONTINUED) SYSTEMS AS NECESSARY.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Accommodation/Occupational Safety
Issued 4 August 1983 Resolved
REPLACE BOTH AIR TANKS ON THE DRILL STRING COMPENSATOR (TANKS HAVE BEEN HYDROED TO 308 PSI FOR TEMPORARY USE).
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Lifesaving
Issued 4 August 1983 Resolved
TOTAL PERSONS ALLOWED ONBOARD VESSEL IS LIMITED TO FORTY-ONE (41), UNTIL THE NUMBER OF ACCEPTABLE PERSONNAL FLOATATION DEVICES ONBOARD IS IN
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Lifesaving
Issued 4 August 1983 Resolved
(REQUIREMENT 1 CONTINUED) COMPLIANCE WITH THE CERTIFICATION OF INSPECTION AND UNTIL THE FOUR (4) INFLATABLE LIFE RAFTS ARE SUITABLY SERVICED
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Lifesaving
Issued 4 August 1983 Resolved
(REQUIREMENT 1 CONTINUED) (WITNESSED BY A USCG INSPECTOR.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Lifesaving
Issued 4 August 1983 Resolved
REPALCE ALL NON-APPROVED FOOD, WATER AND FLARES IN THE LIFEBOATS WITH USCG APPROVED ITEMS.
Condition: Unknown
Due 4 August 1983
Resolved 4 August 1983
Unknown
Issued 24 August 1982 Resolved
ULTRASONICALLY TEST REPAIRS OF FRACTURE IN FUEL TANK A 919 AT NEXT YARD A- VAILABLILITY IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 24 August 1982
Resolved 24 August 1982
Deck/Cargo
Issued 24 August 1982 Resolved
PROPERLY MARK PORT AND STARBOARD CRANE BOOMS WITH SAFE WORKING LOAD.
Condition: Unknown
Due 24 August 1982
Resolved 24 August 1982

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.